| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 CrAdmitted-Finance MILAN NAGAR DIBRUGARH ASSAM PIN 786003 | DIBRUGARH | ASSAM | 786003 | ₹17.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹19.4 CrAdmitted-Finance H NO 280 JYOTI NAGAR P O JALANNAGAR P S GHABHARUPATHAR DIST DIBRUGARH ASSAM PIN 786005 | 786005 | ₹19.4 Cr | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S B.N.Garodia Construction & Engineering Pvt.Ltd. L2 | KUSHAL KONWAR L1 |
|---|---|---|---|---|---|
| 1.00 | SUB-HEAD- EARTH WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil | 5,588.7 | cum | 225 ₹12.6 L | 180 ₹10.1 L |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 3,771 | cum | 225 ₹8.5 L | 220 ₹8.3 L |
| 3.00 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
All Kinds Of Soil | 1,260.93 | cum | 75 ₹94,569.75 | 75 ₹94,569.75 |
| 4.00 | Supplying and filling in plinth with Local sand under floors, including watering, ramming, consolidating and dressing complete. | 349.28 | cum | 1,500 ₹5.2 L | 1,800 ₹6.3 L |
| 5.00 | Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1%
concentration | 1,960.5 | sqm | 125 ₹2.5 L | 220 ₹4.3 L |
| 6.00 | Supplying and stacking at site.90 mm to 45 mm size stone aggregate | 103.41 | cum | 2,000 ₹2.1 L | 1,800 ₹1.9 L |
| 7.00 | Supplying and stacking at site.Good earth | 664.37 | cum | 500 ₹3.3 L | 450 ₹3.0 L |
| 8.00 | SUB-HEAD - CONCRETE WORKProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size
derived from natural sources) | 428.03 | cum | 6,500 ₹27.8 L | 5,600 ₹24.0 L |
| 9.00 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) | 10.3 | cum | 8,500 ₹87,550 | 7,500 ₹77,250 |
| 10.00 | Centering and shuttering including strutting, propping etc. and emoval of form work for :Foundations, footings, bases for columns | 189.07 | sqm | 325 ₹61,447.75 | 270 ₹51,048.90 |
Tender Value
₹19.6 Cr
EMD Value
₹39.1 L
Closing Date
5 Oct 2023, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003.
SOPD_23_24_16 Construction of proposed infrastructure at Khanikor Police Reserve Field, Dibrugarh (Assam) under PWRD, Dibrugarh Lahowal, Moran Tingkhong Territorial Road Division under SOPD-G for the year 2023-24
2023_PWD_32508_1
CE/DEV/TB/92/2023-24/04
Open Tender
Civil Works
720 days
Lahowal
Please refer Tender documents.
4 documents required · 4 mandatory
₹20,000
₹39.1 L
Yes
O/o the Chief Engineer Roads, PWRD, Assam,
8 Nov 2023
14 Sept 2023
6 Oct 2023
14 Sept 2023
5 Oct 2023
28 Sept 2023
14 Sept 2023 - 27 Sept 2023
27 Sept 2023
Amount
SUB-HEAD- EARTH WORKEarth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All Kinds Of Soil
Supplying and filling in plinth with Local sand under floors, including watering, ramming, consolidating and dressing complete.
Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Supplying and stacking at site.90 mm to 45 mm size stone aggregate
Supplying and stacking at site.Good earth
SUB-HEAD - CONCRETE WORKProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
Centering and shuttering including strutting, propping etc. and emoval of form work for :Foundations, footings, bases for columns
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
SUB-HEAD - REINFORCED CEMENT CONCRETEFORM WORKCentering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Centering and shuttering including strutting, propping etc. and removal of form for : Edges of slabs and breaks in floors and wallsUnder 20 cm wide
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges
Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
SUB-HEAD - BRICK WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
SUB HEAD- :-CLADDING WORKProviding and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shadeArea of Slab over 0.50sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
SUB-HEAD - WOOD & PVC WORKProviding wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:25mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws.
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). Decorative type door
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters Kiln seasoned and chemically treated hollock wood
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all completeFixed to steel windows by welding
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete40 mm
Providing and fixing 50 mm bright finished brass cup board or wardrobe knob of approved quality with necessary screws
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. Complete300x10 mm
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. Complete250x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :300x10 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x10 mm
Providing fixing aluminium bolt lock ISI makked anosied Ianodic coating not less than grade AC 10 as per IS 1868 TRANS PARENT OR DYED TO REQUIRED COLOUR AND SHADE with nessary screw bolts nut and washes etc. complete
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete (Best make of approved quality. Double strip (horizontal type).
Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturer's specification and direction of Engineer-in-charge.
Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge. Decorative finish (both side wood grained finish
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125.MM
SUB-HEAD - STEEL WORKSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tube
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile CFixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
SUB-HEAD - FLOORINGCement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 MM Thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slabs.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre .
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 500x500 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. completeSize of Tile 500x500 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood
SUB-HEAD ROOFINGMaking khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
SUB-HEAD FINISHING12 mm cement plaster of mix :1:6 (1 cement : 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
White washing with lime to give an even shade :New work (three or more coats)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Applying priming coat :With ready mixed pink or Grey of approved brand and manufacture on wooden work ( hard and soft wood
Applying priming coat :With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
SUB-HEAD - ALUMINIUM WORKProviding and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4 mm thickness (weight not less than 10.00 kg/ sqm)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 4 mm width
Providing and fixing double action hydraulic floor spring of approved brand and manufacture onforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-chargeWith stainless steel cover plate minimum 1.25 mm thickness
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment)
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 20 mm depth and 20 mm width
SUB-HEAD - WATER PROOFING.Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry
Providing and laying in situ seven course water proofing treatment with APP (Atactic poly-propylene) modified Polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 Kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to IS : 702, 3rd and 5th layers of roofing membrane APP modified Polymeric membrane 1.5 mm thick of 2.25 Kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron HMHDPE film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron HMHDPE film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately).
PLUMBING WORKProviding and fixing white vitreous china pedestal type water closet European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled evice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 gms
Providing and fixing PTMT urinal cock of approved quality and colour.15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing and fixing toilet paper holder :C.P. Brass
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing & fixing Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook of all plumbing connections, angle valve, and other accessories etc complete in all respects as per manufacturer's instructions.
Providing and Fixing single lever basin mixer with 450 mm braided connection pipe all required fittings of approved quality.
Providing and fixing Wall mixer with bend pipe for overhead shower with built-in non return valve having one faucet with all required fittings, flanges etc. of approved makes
Providing and fixing of Sink mixer (wall mounted) with 150 mm (6″) long swivel spout, connecting legs and wall flanges of approved make
Providing and fixing electric water heater of following capcities:25 Ltr
Providing and fixing electric water heater of following capcities:3 Ltr
Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws.
Providing & Fixing Urinal partitions of 10mm thk approved glass of finish chrome size 450mm x 900mm.
SUB HEAD - II - (SOIL, WASTE, RAIN WATER AND VENT PIPES)Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe40 mm dia
Providing and fixing soil, waste and vent pipes :100 mm dia.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
75 mm diameter :Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.40 mm dia nominal bore
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :100 mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : For 100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.100 mm dia.Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing plain bend of required degree.100 mm diaHubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
Providing and fixing single equal plain junction of required degree :100x100x100 mmHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :100 mm
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 75 mm outletHubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing & fixing floor/ ceiling clean out plug with suitable insert keys for opening in: brass cap, male threaded joint with threaded socket fixed to CI pipe joints as required complete in all respects.
SUB HEAD - III - (INTERNAL WATER SUPPLY)Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.32 mm nominal dia Pipes
Providing and fixing brass bib cock of approved quality :15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work65 mm nominal dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :20 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Each Tank Cap. 1 kl @ 4 no.
SUB HEAD - IV - (SEWERAGE AND DRAINAGE)Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soilPipes, cables etc. exceeding 80 mm dia. But not exceeding 300 mm dia
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :nside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes :Size 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :150 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
ELECTRICAL WORKSupplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)6 way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)8 way Double door
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.63 amps
SUB-HEAD - II : INTERNAL WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group – A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group – B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.Group – C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group – A
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group – B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group – C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 x 10 sq.mm + 2 x 6 sq.mm. earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 x 16 sq.mm + 2 x 6 sq.mm. earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton
Supplying and fixing of call bell / buzzer suitable for single phase,230 volt complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.Make: Clipsal NEO C-Metro,MK- Aspect,Legrand - Arteor,ABB - Concept BS
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.Make: Clipsal NEO C-Metro,MK- Aspect,Legrand - Arteor,ABB - Concept BS
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75 mmX75 mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.3 Module (100 mmX75 mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125 mmX75 mm)
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts "C" curve TP MCB complete with connections, testing and commissioning etc. as required. Make:Legrand / Hager / Siemens /Schneider
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make:Legrand / Hager / Siemens /Schneider
Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.Make:Legrand / Hager / Siemens /Schneider
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Supply & Installation of 9 Module Rotatable box having 2 Power 6/13A intel sockets controlled by 1no 16A Switch, 2 data in 1 Module with IO'S CAT6 port male /female to connect data cable, 1 HDMI 1 Passive USB port. Power supply to box with male/female GST connectors. The unit shall be rotated to 180 degree and turned closed while not in use in the meeting room table. Make - Ampere Link, Model - Amp Spin
Supply & Installation of 12 Module Dual Side accessible table top box having 3 Power 6/13A intel sockets, 1 Active USB with A+C Type Outlets, 2 dat CAT6, 1 HDMI 1 Passive USB port. Power supply to box with male/female GST connectors. The unit shall be flushed with table top and should have access from either side of the table. Make - Ampere Link, Model - Amp Dual
Amp Basic, factory assembled modular socket outlet box, housing and components made out of aluminum alloy standard, comprising of 1 switch, 2 Nos. universal socket,1 data/1 Voice with the option of Plug top for power supply. Make - Ampere Link, Model - Amp Basic
SUB-HEAD III - FANS & LIGHT FIXTURES:Supply, Installation, testing & comisioning of 20W linear batten ceilling/wall mounted, housing made of corrosion resistant extruded alumnium. diffused polycarbonate diffuser providing high light transmittance and more uniform light. Suitable for surface and suspended mounting. Beam angle : 120° Cable entries for through-wiring of mains supply cable. Integral constant current power supply, CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation, Led should be L70B10 50,000hrs with minimum luminous flux of 100 lm/W Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply, Operating Voltage : 100-277Vac Operating Temperature : -15°C~+50°C Power Supply : integral Power Factor : >0.95 THD : <10% Surge Protection : 3KV, Efficiency : >90%, luminare dimension should not be less than 1200X43X52 CE,BIS, Klite Model: KL-1589 or equivalent to Regent/LT/Trilux
SITC of IP-40 rated 10W LED ceiling square surface mounted back-lit Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrs High lumen output (Delivered) of at least 90lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <10% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C CE,BIS K Lite Model KL-7639 or equivalent to Regent/LT/Trilux
Supply, Installation, testing & comisioning of 24W linear batten wall mounted, housing made of corrosion resistant extruded alumnium. diffused polycarbonate diffuser providing high light transmittance and more uniform light. Suitable for surface and suspended mounting. Beam angle : 120° Cable entries for through-wiring of mains supply cable. Integral constant current power supply, CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation, Led should be L70B10 50,000hrs with minimum luminous flux of 100 lm/W Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply, Operating Voltage : 100-277Vac Operating Temperature : -15°C~+50°C Power Supply : integral Power Factor : >0.95 THD : <10% Surge Protection : 3KV, Efficiency : >90%, luminare dimension should not be less than 1200X43X52 CE,BIS, Klite Model: KL-1670 or equivalent to Regent/LT/Trilux
Supply, Installation, Testing and Commissioning of Recessed 2x2 LED luminaire with system power [40W ± 5%], Available in 3000K/4000K/6000K color temperature, made of CRCA housing with aluminium front frame, must be equipped with Prismatic Acrylic diffuser UGR<21 . Powder coated with white epoxy polyester with operational voltage range of 180-240V, power factor > 0.95, THD < 10%, Inbuilt surge protection of 2.5 KV, Luminaire has Ingress protection of IP44 The luminaire should have minimum lumen output of 4000 ± 10% lumens , CRI of >80 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from in house NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers Make: K-Lite Model KL-2288 or equivalent to Regent/LT/Trilux
SITC of IP-40 rated 16W LED ceiling square surface mounted back-lit Indoor luminaire with soft uniform Light distribution. Luminaire should be made of die-cast aluminium for better thermal management. High efficiency diffuser for glare free, uniform light distribution. CRI (Ra) : >80, SDCM≤ 3 to avoid color deviation , Led life should be atleast L70B10 50,000hrs High lumen output (Delivered) of at least 90lm/w.High PF constant current LED driver with surge and thermal protection with follwoing ratings Power Supply : Integrated Power Factor : >0.90 THD : <10% Surge Protection : 2.5KV Efficiency : >83%.Suitable for operation on 240V, 50Hz single phase ac supply, Operating Voltage : 90-265Vac Operating Temperature : -15°~+50°C CE,BIS. K Lite Model KL-7331 or equivalent to Regent/LT/Trilux
SITC of Wall Maounted Mirror LightLED fixture with system power [12W± 5%] should be available in 3000K/4000K/6000K color temperature, minimum dimesnion 226 x 94 x 108mm, should be made up Luminaire made of extruded aluminium with fabricated aluminium frame, Extruded aluminium housing profile designed to throw upward and downward lighting, UGR<19, operational voltage range of 90-265V, power factor > 0.9, THD < 10%, Inbuilt surge protection of 3 KV, Luminaire has Ingress protection of IP20. The luminaire should have minimum lumen output of 1000 lumens , CRI of >80 . The LEDs used have a life of 50000 burning hrs Lumen maintenance as per L70B10 with SDCM<=3 binning Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-03/05/06/07, Surge : IEC 61000-4-5, IES, LM 79, LM 80, & TTC certificates will be provided from NABL accredited lab. Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers. K-Lite Model KL-3778 or equivalent to Regent/LT/Trilux
Supply, Installation, Testing & Commissioning of 15W WALL BRACKET LIGHT, Housing Material Cast Aluminium with B22 Holder Tye, Diffuser Material PPR with TIN Coated Powder Coated Finish, Suitable of used with 15W LED Lamp
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as rSITC Fresh air fan 300 mm
SUB HEAD - IV : RACEWAY AND CABLE TRAYMetal Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:250 x 38 mm Raceway with 3 compartments.
Metal Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:200 x 38 mm Raceway with 1 compartments
Metal Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:100 x 38 mm Raceway with 1 compartments.
Metal Raceways : Floors Supply and fixing in position of following size of under floor GI raceways [consists of body & cover] for distributing cabling in screed floor installations. Raceway should be made up of Pre galvanized sheet conforming to IS 277 with thickness of 1.6mm consists of Body and Openable cover with 275 GSM coating. Raceway should be supplied with required accessories such as fixing brackets and coupling plates as required. Raceway should be confirmed with the standard EN 60-670 and EN 50085-2-2, IP 20 & IK08 in recess / on surface including chasing the wall/floor complete as required of following configurations:75 x 38 mm Raceway with 1 compartments
Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:Sizes:Box : 400 x 400 x 65-90mm [1mm base & 3mm lid]Cover Plate : 400 x 400mm
Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:Sizes:Box : 300 x 300 x 65-90mm [1mm base & 3mm lid]Cover Plate : 300 x 300mm
Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:Sizes:Box : 225 x 225 x 65-90mm [1mm base & 3mm lid]Cover Plate : 225 x 225mm
Metal Junction Box : Floors Supply and fixing in position height adjustable under floor crossover Junction box for Raceways for direct access to cables at the intersection of Raceways supplied completely with base and cover plate [lid]. Junction box should be made of Pre galvanized sheet consist of body and cover. Height of the junction box should be adjustable from minimum 65mm. Junction box should be supplied with the metal cover for protecting the junction box during constructions at site. It should be confirmed with the standard EN 50085-2-2 including all accessories complete as required of following sizes:Sizes:Box : 150 x 150 x 65-90mm [1mm base & 3mm lid]Cover Plate : 150 x 150mm
Cable TraySupplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays bends with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays reducers with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Tee's with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated pre-painted M.S cable trays Cross members with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts&nuts, painting suspenders etc as required.600 mm width X 50 mm depth X 2.0mm thickness
SUB HEAD -V SUBSTATION WORKHT Metering Panel (SEB's) Supplying / Receiving, Installation, Testing and Commissioning of Powder coated, 14 SWG CRCA sheet steel enclosed 11 KV H.T. Metering Panel complete with the following:1set of 11/ √3KV / 110/ √ 3 Volt, 100 VA burden & accuracy class 0.5, single phase construction, dry type cast resin PT. 3 Nos. of dual core 50/5A, 15 VA burden, accuracy class CL 0.5, 11 KV cast resin CTsOne Set of Phase Indicating Lamps.2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A).2 Nos. indoor cable end box suitable for 3C x 240 sq.mm. 11 KV(E), aluminium conductor XLPE Ar. cable (Incoming & Outgoing cable).1 No. SEB approved digital Trivector meter with MDI in KVA of accuracy class - 0.5.(Accuracy class shall be as per local board)Note: The contractor shall get the Trivector meter, CTs' & PT tested by SEB and the charges for liasioning for the same will be paid extra.Supply Rate for Metering Panel as described above ,
Installation & Commissioning Rate for Metering Panel as described above Note: The contractor shall ensure that the above panel meets the requirement as insisted by State/Local authorities(As per SEB) for satisfactory operation and as per the Drawings
SUPPLY OF 500KVA, 11KV/433 VOLT TRANSFORMER (OIL FILLED) WITH ON LOAD TAP CHANGER., Design, manufacture, testing at works, supply and delivery, including supervision during installation, testing and commissioning to be carried out of 250 KVA, 11KV/415V outdoor type Transformer (oil filled) with On Load Tap Changer as specified in the Technical specifications, complete with the following standard, mountings, fittings, accessories, etc as required.The Transformer must confirm to the IS 1180 & its latest amendment., This specification covers design, manufacturing, testing and delivery of the Mineral Oil Immersed Transformer. As per Standard IS 335 Mineral Oil for transformer.Cooling shall be via Mineral Oil Naturally circulated and Air Naturally circulated.The OLTC gear shall withstand through fault currents without injury, No load voltage Ratio : 11KV / 415 V, No. of Phases / Freq.: 3 Phase/50 Hz., Type : Core type, doublecopper wound, Cooling : ONAN, Vector Group : DYn11, Temperature rise : 40/45 Deg. (oil / winding) , ROUTINE TESTS as per IS 2026 – The manufacturer should have NABL accredited test lab. Manufacturer should have BIS certification for identical transformer., On load type tap changer , Taps on HV for HV variation : + 5% to -15% in steps of 1.25% each, Termination (HV) : Air Filled cable box suitable for 11KV 3C X 300 Sq.mm Al. Armoured XLPE Cable., Termination (LV) : Suitable flange for termination of 2 runs 3.5 x 300 Sq.mm Al. Armoured XLPE Cable., Impedance at 75 Degree celsius : As per IS 1180, Total Loss at Rated load, Voltage & frequency shall be: As per IS 1180 ( Energy efficiency Level 1 ) , The transformer shall be supplied with Standard fittings as per specifications including the following :, Unless otherwise stated, the tank together with radiators, conservator, bushings and other fittings shall be designed to withstand without permanent distortion the following conditions:, 1.Vacuum withstand shall be as per CBIP Guideline, 2.Internal gas pressure of 0.35 Kg/cm2 (5 lbs/sq.in) with oil at operating level, a. Conservator with drain valve., b. Magnetic oil level indicator., c. Silicagel breather with oil seal., d. First filling of oil as per IS 335 including make up during installation of transformer plus 10% extra oil. To be supplied - in a container., e. Thermometer pocket with plug, f. Air release plug, g. Inspection cover, h. Top filter brass gate valve - 1 no., i. Removable Lifting lugs and Jack lifting pad support, j. Earthing terminals - 2 nos.for body earth and neutral earthing bushing terminal on transformer top cover., k. Radiator with top and bottom shut off brass gate valves, l.Rating and Diagram plate., m.Bi-directional Plain/Flanged Rollers., n. Drain cum bottom filter valve - 1 no., o. Explosion vent with double diaphragm and sight glass., p. Buchholtz relay with shut off valve., q. 100 mm dial magnetic oil level gauge with max pointer and low level alarm contacts., r. 150 mm dial oil temperature indicator (OTI) with max pointer and 2 sets of Contact for Alarm & trip., s. 150 mm dial winding temperature indicator (WTI) with max pointer & 2 sets of contacts for alarm & trip., t. Magnetic oil level indicator with annunciation., u. Marshalling box with GLS lamp point and 15A switchsocket oulet point with watertight lockable cover lid., NOTE :- Item shall be suitable for termination of multicore (minimum 6 core 2.5 sq.mm. Copper ) conductor armoured cable connecting between respective equipment to terminal block in marshalling box to annunciation window panel and to main breaker as required. (The Transformer losses shall not be more than maximum allowable losses as per IS Code:1180 Energy efficiency Level 1 ), Transformer described as above(MAKE VOLTAMP,KIRLOSKAR,SCHNEIDER),
11 kV 2 POLE STRUCTURESupply, installation, testing & commissioning of two 11Mtr. pole structure, 11KV with cross arms, suitable clamps, insulators, disc insulators, 11KV lightning arrestors, complete stay with insulator & wire, foundations, gang operated air break switch with extended handle, 11KV drop out fuses. This shall have termination arrangement for outgoing through HT XLPE cable of suitable size and necessary 6 inches dia GI pipe shall be provided for cable support complete in every way.11 kV HT 'H' pole as per specification & as described above
APPROVAL / LIASIONING WORK WITH STATUTORY AUTHORITIES :(i) Charges for Liasioning with State Electricity Board for getting approvals, clearances for load sanction and obtaining connection etc. Complete for energising the installation with State Electricity Board power as required. The charges shall broadly include but not limited to following and as per SCC.(ii) Load application, load sanction, drawing / scheme approval by CEIG / any other statutory bodies, inspection and approval of installation by CEIG / any other statutory bodies, demand notice & estimate, service connection order, permanent connection and energization.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
SUB HEAD-IX : CABLE & END TERMINATIONSLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Laying of one number XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 25 sq. mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm)
Supply of MV cableSupply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 300 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 240 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 185 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 150 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 120 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.3 ½ C - 95 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.4C- 25 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.4C- 16 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.4C- 10 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade.2C- 10 sq mm Aluminium
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.200mm dia
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.250mm dia
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 160 mm dia (OD-160 mm & ID-135 mm nominal)
SUB HEAD-X : EXTERNAL LIGHTINGSupply of following sizes XLPE insulated (Heavy duty) Aluminium or Copper conductor armoured cables suitable for working voltage upto and including 1100 Volts complete as required and as per specifications.2 x 6 sq.mm
Supply of following sizes XLPE insulated (Heavy duty) Aluminium or Copper conductor armoured cables suitable for working voltage upto and including 1100 Volts complete as required and as per specifications.4 x 6 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Termination of the following sizes of XLPE insulated Aluminium/ Copper conductor cable including providing terminal lugs,double compression gland , crimping the joints ,providing insulation tape,effecting terminal connections to the equipment complete as required. 2 x 6 sq,mm, Al conductor cable
Supply, laying and termination of the following sizes of 650/1100 volts grade PVC insulated copper conductor wires in existing conduits including end terminations with copper lugs.3 x 2.5 sq.mm. Copper conductor ,PVC insulated PVC sheathed wires
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100mm dia
Supply,fixing and laying of Heavy duty PVC pipes complete buried in floor with joints and other accessories as required. 63 mm dia, 2mm thick
Supply, erection, testing and commissioning of 4 M high Tubular pole as per Technical specifications and with following components :-Including supply and installation of 6 ways-20A connector & 6A MCB mounted on 6mm thick painted M.S/GI plate, insulated, and fixed inside the pole suitable for termination of armoured aluminium cable as required and wiring to Luminaries from the 6A MCB, with 3x2.5 sq.mm. PVC insulated copper, stranded conductor (P+N+PE) double sheathed wire including terminations.4 meters high tubular pole with single arm of length 1 meter, smoothly curved making an angle of 10 deg to 15 deg with the horizontal plane complete as required.
Supply,Receiving and fixing in position, effecting proper connections, testing and commissioning of 40W Luminaire on existing 4 Mtr pole as per specifications,complete in all repects including nipple for fixing of Light fixture on pole.
Supply,Receiving and fixing in position, effecting proper connections, testing and commissioning of 35 W GATE LIGHT
Supply, Installation & Commissioning of Solar PV stand alone Street Lighting System comprising of two 37 Wp / one 74 Wp SPV module, one 12 V, 75 Ah Tubular Plate sealed maintenance free VRLA Gel Battery, one luminaries with inbuilt inverter, dusk to dawn circuit for automatic switching on & off at dusk & dawn and 24 W LED Light, pole, one charge-regulator, module mounting structure, Pole mounted Battery box, cables and other fittings along with 5 (five) years guarantee / warranty period (25 years for SPV Module).
Supply, installation Testing including civil foundation work & commissioning of fixed type high mast lighting tower (16 mtr.) with 8 Nos. 300 watt LED flood light fittings for outdoor lighting application.
SIDE DEVELOPMENT CIVIL WORKEARTH WORKEarth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 mOrdinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All Kinds Of Soil
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.All kinds of soil
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
SUB-HEAD - CONCRETE WORKProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and emoval of form work for :Foundations, footings, bases for columns
SUBHEAD-:-REINFORCED CEMENT CONCRETE WORKCentering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts
Columns, Pillars, Piers, Abutments, Posts and Struts Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level
SUB-HEAD - BRICK WORKBrick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
SUB-HEAD -FINISHING WORK12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm
SUB-HEAD -ROAD WORKPreparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and stacking at site.90 mm to 45 mm size stone aggregate.
Supplying and stacking at site.63 mm to 45 mm size stone aggregate
Supplying and stacking at site.53 mm to 22.4 mm size stone aggregate.
Supplying and stacking at site.Good earth
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density .
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Surface dressing on new surface with paving bitumen of grade VG - 10 of approved quality using 2.25 kg of bitumen per sqm with 1.65 cum of stone chippings 13.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete:
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints ( 10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineerin- charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.cement concrete prepared with batch mixing
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
EXTERNAL PLUMBING WORKExcavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All Kind of SoilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Pipes, cables etc. exceeding 300 mm
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (exceeding 3 m in depth, but not exceeding 4.5 m.).All kind of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (exceeding 3 m in depth, but not exceeding 4.5 m.).All kind of soilPipes, cables etc. exceeding 300 mm dia
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Ordinary rockPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :Ordinary rockPipes, cables etc. exceeding 300 mm dia
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).Ordinary rockPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).Ordinary rockPipes, cables etc. exceeding 300 mm dia
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.All Kind of Soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.Ordinary rock
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Carriage of earth by mechanical transport including loading, unloading and stacking upto 1km
Providing and fixing G.I. pipes complete with G.I. fittings including, trenching and refilling etc.external works100 mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :100 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade all-round the G.I. pipes in external work.100 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 32 mm nominal bore.
Providing and fixing butterfly valves, wafer end type class PN 1.6 as per I.S:13095 - 1991 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box) 100mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Constructing masonary chamber 90 cm X 90 cm X 100 cm inside with 75 class designation brick work in cement mortar 1: 4 ( 1 cement : 4 coarse sand ) for sluice valve with C. I. Surface Box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix(1 cement:2 coarse sand:4 graded stone aggregate 20mm nominal size) necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3(1 cement :3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design.With common burnt clay F.P.S.(non modular) bricks of class designation 7.5.
Providing and fixing CI sluice valve (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately)100 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :300 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :450 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :500 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :700 mm dia. R.C.C. pipe
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with SFRC cover and frame (heavy duty, HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22 m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 2.30 m deep with SFRC Cover and frame (heavy duty HD20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52 m internal dia (at bottom) beyond 2.30 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Domestic Water Pump Providing, fixing and testing of factory fitted packaged skid mounted pumping system.Vertical, inline multistage centrifugal pumping set with stainless steel SS-316L stage casing and SS-316L impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply.Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation.Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan.SS Suction and delivery header with Ball valves Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement.Complete set system to be mounted on a common base frame and shall follow following duty.Domestic Water PumpsFor Pumping StationDomestic Water Pumps(Set of 2 Pumps. One Working + One Standby)Capacity : app. 500 lpmHead : app. 50 m
Filter Feed Pump Providing, fixing and testing of skid mounted pumping system comprising of :-Horizontal, Single Stage centrifugal pumping set with stainless steel SS-316L stage casing and SS-316L impellers with stainless steel SS-316L shaft as per IEC standards and GJL250 cast iron suction & discharge casing, connected to TEFC ventilated induction motor of 2 pole, 2900rpm, suitable for 400/440 Volts, 3 phase, 50 Hz A.C. supply.Control Panel with programmable logic controller (PLC) for cyclic operation of pumps. Pump working sequence should change after every operation.Contractor overload relays and MCBs should confirm to IEC 898 – 1995/ specifications. Blinking indications for pumps start, trip, low level trip, health supply should be provided in the panel along with the ammeter & voltmeter. Control panel should also consist of cooling fan, controlloer for start and stop of pumps in case of high level and low level in treated water tank, cables, earth wire & control cables.SS Suction and delivery header with Ball valves Hot Pressed brass OT-58 with stainless steel ball and P.T.F.E seal and O-Ring. NRVs to be used should be with Springs and O-Ring arrangement.Complete set system to be mounted on a common base frame and shall follow following duty.For Pumping StationFilter/Softener Feed PumpNo. of Pumps: 2 (1 Working + 1 Stand by )Capacity : app.500 lpmHead : 25m
Pressure Filter (Domestic Water)Providing and fixing vertical pressure filter with dual media filter (comprising of 600mm bed depth of graded sand gravel and 600mm bed depth of Anthracite) fabricated from high performance M.S plate of minimum 8mm thick for shell & 10mm thick for dished ends with top and bottom flanged openings including top and bottom hub and lateral distribution and collection system complete with initial charge of filter media, face piping, valves, accessories, painting, testing and commissioning complete.(Tested to 6 Kg/m2)Discharge : 25000 lphFiltration Rate : 20000 lit./m2/h Suggested dia app. : 1300 mm
Activated carbon Filter (Domestic Water)Providing and fixing vertical activated carbon filter comprising of activated carbon filter media fabricated from high performance M.S plate of minimum 8mm thick for shell & 10mm thick for dished ends with top and bottom flanged openings including top and bottom hub and lateral distribution and collection system complete with initial charge of filter media, face piping, valves, accessories, painting, testing and commissioning complete.(Tested to 6 Kg/m2)Discharge : 25000 lphFiltration Rate : 20000 lit./m2/h Suggested dia app. : 1300 mm
Water SoftenerProviding and fixing water softener fabricated from minimum 8mm thick M.S. plate on shell and 10mm thick M.S. plate on dished ends complete with initial charge of filter media and ION exchange resins, face piping accessories, piping testing and commissioning complete with resins of approved quality and make and brine tank of required capacity. (Bidder must indicate type and quantity of resin used and quantity of salt required per regeneration).Minimum expected rate of flow: 2000 lph Total soft water to be produced between two regeneration: app. 100 Cu.m Expected raw water hardness : app. 500 ppmExpected treated water hardness: less than 100 ppmMax. working pressure : 4 Kg/cm2 Total soft water to be produced between two regeneration: app. 100 Cu.m
Providing and fixing M.S salt saturator, internally rubber lined as per requirement and externally painted with suitable anti-corrosive paint, with all required accessories for holding and supplying salt for softener complete in all respects, with electrically operated stirrer and of capacity 500 litres.
Providing and fixing motor pump controller cum water level indicating panel in powder coated sheet metal box in 16 gauges M.S including the following:Electronic water level controller working on magnetic type sensing probes with necessary length of armored cable up to control panel.Electronic minimum 4-level indicator with magnetic type sensing probes and necessary length of armored cable upto control panel.Arrangement of alternate switching mechanism for operational and standby pumps.For Water level indicators with following details:Underground tanksMinimum 4 level Multi level indicators with magnetic type sensor probes complete.
For water level controllers with electronic sensing probe complete in all respect for following functions.i) Domestic Water transfer Pumps To cut off at low level in domestic water U.G tanks.
Providing and fixing G.I. pipes (I.S. 1239 heavy duty class) complete with all necessary G.I. Fittings including all necessary fittings like bends, elbows, tees etc., either welded or screwed or flanged joints as per requirements, including all anchor blocks, anchor fasteners, couplings in all respects including enamel painting of required shade, cutting holes and chases in RCC wall and making good complete (The cost of flanges will be paid separately).100 mm dia
Providing and fixing C.I double flanges suction strainer bucket type/ “Y” type PN 1.0 including, nuts, bolts and 3mm thick rubber insertion complete.100mm dia
Providing and fixing rubber expansion joint (to provide relief from stresses at pipe flanges) as per specification of the manufacturers and direction of Engineer in chief PN-16 rating100mm dia nominal bore.
Providing and fixing butterfly valves, wafer end type class PN 1.6 as per I.S:13095 - 1991 or BS:5155, including necessary nuts, bolts, gaskets etc. complete (without gear box) 100mm dia nominal bore.
Providing and fixing Non return valves, wafer end type class PN 1.6 as per I.S:5312, including necessary nuts, bolts, gaskets etc. complete 100mm dia nominal bore.
Submersible pumpsSubmersible single stage single entry pumps with C.I.body and C.I. two vane enclosed type impeller connected to TEFC submersible motor for 415 volts, 3 phase, 50 cycles including MCC panel with level controllers, auto control, sequential change over facility with one proper working at low level & two proper working at high level with an audible alarm including all interconnectivity cables, with both pumps connected to common outlet header including valves, non return valves, lifting chains etc. complete in all respect(one working+One Standby)(Solid handiling capacity 12mm)Capacity- 225 lpm (Each)Head - 12 mHP (Approx) 1.0 HP
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.All types of soil300 mm nominal size dia
Rocky strata including BouldersSupplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mmmm x 1.6 mm complete, all as per direction of Engineer-in-charge.
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).200 mm dia
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore
Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm nominal bore
Supplying & installation of submersible pump set directly coupled with 5 HP motor nominal speed 2900 RPM suitable for operation on 3-phase, 50 cycles, 400 + 5% volts A.C. power supply to give yield of 5100 LPH at a head of 50 mtrs.Total head = 60 MtFlow rate = 5100 LPHH P =Minimum 2 HP (Or as per site condition)
M/S B.N.Garodia Construction & Engineering Pvt.Ltd.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
SBD_Khankior.pdf
Tender Documents • 4.41 MB
FOB.pdf
Additional Documents • 0.23 MB
BOQ_52186.xls
BOQ • 0.76 MB
Download all tender documents and submit your bid