Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹43.6 LAccepted-AOC P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L-1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L-2₹44.9 L+₹1.3 L (2.97%)Rejected-AOC 29 KESHULI AKOUR MADHUBANI MADHUBANI BIHAR 847230 UDYAM BR 20 0037592 | MADHUBANI | BIHAR | 847230 | L-2 | Rejected-AOC BEING L2 BIDDER | |
| 3 | L-3₹45.9 L+₹2.3 L (5.30%)Rejected-AOC THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L-3 | Rejected-AOC BEING L3 BIDDER | |
| 4 | L-4₹46.0 L+₹2.4 L (5.59%)Rejected-AOC C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L-4 | Rejected-AOC BEING L4 BIDDER | |
| 5 | L-5₹48.8 L+₹5.2 L (12.0%)Rejected-AOC RANGIYA STATION ROAD WARD NO 2 PO RANGIYA DIST KAMRUP ASSAM PIN 781365 | BAKSA | ASSAM | 781365 | L-5 | Rejected-AOC BEING L5 BIDDER |
Tender Value
₹49.1 L
EMD Value
₹98,140
Closing Date
10 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP TO BLDG No. ET-184, ET-173 AND CERTAIN OTHER SANCTIONED WORKS AT RANGIA MIL STN UNDER GE RANGIA
2023_MES_608945_1
8687/E8
Open Tender
Civil Works
Item Rate
180 days
RANGIA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Rangia
₹98,140
Yes
15 Sept 2023
13 Jul 2023
12 Aug 2023
13 Jul 2023
10 Aug 2023
28 Jul 2023
13 Jul 2023 - 21 Jul 2023
Amount
M&L for Dismantling posts or struts (wood, steel or R.C.C.) of any section, embedded in concrete including taking out embedded portion and making good disturbed ground, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforced Cement concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-charge.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified and as directed by Engineer-in-charge.
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber scantlings 40 sq. cm and over in section, in any position and in unframed work, complete all as specified and as directed by Engineer-in-charge.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section and in unframed work, complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and as directed by Engineer-in-charge.
M&L for Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil, complete all as per specified and as directed by Engineer-in-charge.
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
M&L for providing Pre-cast Reinforced Cement Concrete (nominal mix) 1:2:4 (20mm graded stone aggregate) type B-1, in fencing posts with sectional area exceeding 100 Sqcm but not exceeding 250 Sqcm including use and waste of Formwork as required/ordered at Site(s), complete all as specified and as directed. NOTE : Reinforcement will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-15 (Nominal Mix) 1:2:4 (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-15 (Nominal Mix) 1:2:4 (20mm graded stone aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span, chajjas, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Reinforced Cement Concrete, M-15 (Nominal Mix) 1:2:4 (20mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, chajjas, etc. also splays between floors and beams, etc., rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
S&F of Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular/ hollow/ flat sections) including distance pieces, cleats etc. of Fe 410-W(Gde- E- 250) quality-A, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 29 here-in-above, but erection only, complete all as per specified and as directed by Engineer-in-charge.
M&L for 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
M&L for 50mm thick second class hard wood boarding in any situation and in any position, planed both sides fixed with nails, complete all as specified and as directed by Engineer-in-charge.
M&L for second class hard wood plain fillets in square, rectangular or triangular in section, clean sawn, secured with nails or brads of sectional area exc. 6sqcm but not exc.13sqcm, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on fair faces of brick work or concrete surfaces/ one side of lathing, finished even and smooth (without using extra cement), complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 in two layers on other than fair faces Brick Walls/Concrete Surfaces/ other side of lathing, 5mm thick top layer mixed with WPC as per Manufactures instruction, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge. NOTE: WPC shall be Measured and Paid as ‘Supply only’ under relevant Item.
Supply only Integral waterproofing compound, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing glossy finished Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth without using extra cement, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., laid over 20mm thick cement screed 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as per specified and as directed by Engineer-in-charge.
All as per Item No. 43 here-in-above, but area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in vertical surface (like skirting, dado, etc.), over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing Glazed ceramic coloured tiles in vertical surface (like skirting, dado, etc.) 300x 450x 7 mm thick, over 10mm thick cement screed 1:3 set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as per specified and as directed by Engineer-in-charge.
M&L for 20mm thick Granite work (of any type, table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as per specified and as directed by Engineer-in-charge.
M&L for Forming Construction (Dummy) joints 30mm deep x 10mm wide filled with sealing compound Grade 'A', complete all as specified and as directed by Engineer-in-charge.
M&L for providing 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of 12mm thick frosted type toughened glass door, each shutter mounted on Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty with and including 200mm long Stainless steel handles 2 Nos in each door, 1 No stainless steel 6-lever Mortice lock, vertical type, size 100 mm, anodised aluminum snap beading screws etc., complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Anodised aluminium door using 96.6x44.8x1.5mm thick Anodised aluminium section as in chowkhat, 84.0x44.7x1.5mm thick section as in vertical styles and 101.6x44.88x1.5mm thick section as in rails with and including necessary joining cleats, glazing clips, ruber neoprene packing, 5.5mm thick reflective type sheet glass, 200mm long aluminium handles 2 Nos in each door, 100mm long medium grade stainless steel butt hinges of 4 Nos, 1 No aluminium (extruded section) body Door closer hydraulically regulated suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg, 1 No Mild steel 4-lever Mortice lock, vertical type, size 100 mm, anodised aluminum snap beading screws etc., complete all as specified and as directed by Engineer-in-charge.
S&F in-reapir of Anodised aluminium sliding window and ventilator using 62x29.5x1.5mm thick Anodised aluminium section as in chowkhat, 38.0x20.0x1.5mm thick section as in shutter with and including necessary joining cleats, glazing clips, ruber neoprene packing, 4mm thick reflective type sheet glass, 100mm long aluminium handles 2 Nos, 1 No aluminium tower bolt in each shutter, anodised aluminum snap beading screws etc., complete all as specified and as directed by Engineer-in-charge.
S&F of 3mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
M&L for providing GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
M&L for providing in patches not exc. 0.50Sqm GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 20 mm dia mild steel, chromium plated curtain rail with fixing brackets, stops, rollers etc., complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 6mm thick asbestos cement, corrugated or semi-corrugated sheets with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc., complete all as specified and as directed by Engineer-in-charge.
Labour only for fixing of 6mm thick asbestos cement, corrugated or semi-corrugated sheets with two corrugations side lap fixed with L-type or J-type or cranked hook bolts in roof, wall etc., complete all as specified and as directed by Engineer-in-charge.
S&F of 6mm thick Asbestos cement serrated ridge for corrugated or semi-corrugated sheets fixed with L-type or J-type or cranked hook bolts in roof, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for applying two coats of Acrylic Smooth exterior paint of required shade on new surface over and including priming coat of exterior primer over a coat of avg 1.0mm thick wall care putty (Exterior grade) including rubbing down the putty surfaces to obtained smooth finished surface, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of cement base paint of any shade over a coat of alkali-resistant priming paint, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated wooden Surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of Creosote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for Complete removal of existing treatment of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for Complete removal of existing treatment of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 1.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment of wall and applying two coats of Acrylic Smooth exterior paint of required shade over and including priming coat of exterior primer over a coat of avg 1.0mm thick wall care putty (Exterior grade) including rubbing down the putty surfaces to obtained smooth finished surface, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of old painted steel/ iron surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of Synthetic enamel paint (1st quality) of any tint, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 15mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 20mm dia galvanised steel tubes, 'medium grade', with all fitting; fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Wash down couple water closet (Cistern mounted) pan and S/P trap of 680x370x750mm with and including Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or anodised aluminium hinging device including connection to drain (or outgoing pipe) and antisyphonage pipe, etc., complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Vitreous China wash basin wall hung type, white, size 200x550x400mm including fixed to wall with CP brass screws, fixing of 15mm dia 450mm long PVC connection pipe and 32mm dia 900mm long PVC Flexible waste pipe with and including 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.; complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.0 metre long flexible tube and ABS wall hook including making connections and fixed in position, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 15 mm dia fancy type chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 15 mm dia fancy type chromium plated Bib taps 2-in-1 (2-way), cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 15 mm dia fancy type Brass CP basin mixer without pop up waste for mixing hot & cold water, screwed for iron pipe, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 15 mm dia fancy type, chromium plated Stop valves/ Angle valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 32mm dia High density poly ethylene pipes (HDPE) of pressure rating 6 kg/ cm2 fixed to walls and ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 110mm dia PVC (SWR) bends any radius, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 110mm dia PVC (SWR) vent cowl, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of PVC connection pipe 15mm dia with PTMT nuts of length 450mm, complete all as specified and as directed by Engineer-in-charge.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and excluding tube light fittings etc, removing materials from site and making good distrubed surface of wall, floors, etc. complete all as specified and as directed by Engineer-in-charge.
Taking down Old Air conditioner, both indoor and outdoor unit, kept in safe custody for re-installing in original position with and including cleaning, servicing, gas charging and testing, complete all as specified and as directed by Engineer-in-charge.
M&L for disconnecting and taking down ceiling fan/ exhaust fan of any sweep, sealing cable end, dismantling blades and keep fan and blades in safe custody and re-fixing the same into existing position, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 96 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 96 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 96 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Socket outlet 3 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 5/6 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5Pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Modular Bell push 6Amp, 1 module, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Bell Buzzer/ Ding Dong, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of of Sheet Metal Enclosure MCB DB TPN, vertical type, 4 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 415 volt, with 200 amps rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F of Sheet Metal Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amp for AC point, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Triple Pole & Neutral (TPN), 'C' Curve, 40-100 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 40-63 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting 1x 20W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of slim square panel LED luminaire with frame 600 mm x 600 mm, white powder coated with CRCA housing, 35/36 watt, 220-240 V, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED light fitting mirror type 1x 10W, (2 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED lamp connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of energy saving ultra modern environmental friendly sleek LED Bulk head fitting 10 watt, IP65 protection with driver, holders & LED lamp including connecting up with three core flexible copper conductor cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of 7 watt capacity, B-22 base LED Bulb/ lamp, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, sturdy engineering plastic body, AC single Phase, 230V of size 250m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F of exhaust fan, heavy duty, steel body, AC single Phase, 230V of size 380m sweep with, blades, frame and louvers including connecting up with three core flexible copper cables of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply & laying of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 25 Sqmm 4 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor including Testing and taking down the existing old damaged cable, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sub-main Wiring with 2-Runs of Single Core 6.0 Sq mm PVC insulated FRLSH multi-stranded 1100 Volts grade with Copper Conductor drawn through and including Non-metalic Rigid PVC Casing capping ISI marked and its Accessories including 1-Run of Single Core 6.0 Sq mm PVC insulated FRLSH unsheated multi-stranded 1100 Volts grade with Copper Conductor Cable as Earth Continuty Conductor along with the Wiring and connected from DB to DB/Main Board and taking down the existing old unserviceable wiring, complete all as specified and as directed. NOTE :- (a) Cost of PVC Casing capping with all Fittings/Accessories will deem to be included in the quoted UNIT RATE. (b) Cables as mentioned in SCHEDULE ‘A’ Items and 1-Run of PVC Casing capping with all Fittings/Accessories will be measured and paid as ONE UNIT. (c) Sub-main Wiring will be measured PVC Casing capping only. Wire required for looping, etc as ordered will deem to be included in the quoted UNIT RATE.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down the existing old unserviceable one, complete all as specified & testing on completion. NOTE:- (i) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire.
A K C PROJECT
M/S Rajkamal Enterprise
M/S S.S. Construction
M/s SHARMA BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .