Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.2 Cr+₹10.1 L (9.00%)Rejected-AOC | ₹1.2 Cr+₹10.1 L (9.00%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.4 Cr+₹31.7 L (28.3%)Rejected-AOC | ₹1.4 Cr+₹31.7 L (28.3%) | L3 | Rejected-AOC L3 |
Tender Value
₹1.3 Cr
EMD Value
₹2.7 L
Closing Date
25 Mar 2019, 2:00 pmClosed
Addl. CE, PWD (Bldg), PCC Project Complex, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Audio Visual Hub of Jyoti Chitraban under NEC. ( Civil works for Studio Building )
2019_PWBNH_12522_1
CS/T/BD/04/2019/7 Jyoti Chitraban
Open Tender
Civil Works - Building
Item Rate
270 days
Jyoti Chitraban
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,500
Assam State Road Board Maintenance (Road) Fund
₹2.7 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
10 Aug 2020
7 Mar 2019
25 Mar 2019
7 Mar 2019
25 Mar 2019
7 Mar 2019
12 Mar 2019
Amount
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing ground level. (b) In hard/ dense soil
(B) Extra over item no.1.1(A) above for each 1m depth or part thereof beyond the initial depth of 2m
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m
(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. b) 50mm thick
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. c) 100mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Plain cement concrete apron in prop 1:4:8 with 20mm down graded coarse agg. Over soling including neat cement finish using cement slurry 2.75Kg. of cement per sq.m. of floor (soling to be measured separately). (a) 35mm thick
Plain cement concrete apron in prop 1:4:8 with 20mm down graded coarse agg. Over soling including neat cement finish using cement slurry 2.75Kg. of cement per sq.m. of floor (soling to be measured separately). (b) 50mm thick
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) (I) Using Mixer Machine (A) In substructure up to plinth level Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. P) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required. b) M20 grade concrete or Prop. 1:1.5:3
(B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser b) M20 grade concrete or Prop. 1:1.5:3
Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (a) Using 38mm thick plank
Sides of tie beams, grade beams etc. at or below ground level. (a) Using 38mm thick plank
Columns, Pillars, Posts & Strut (a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face (i) Using 38mm thick plank
(b) Circular or curved in plan (Using 38mm thick plank)
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (a) For depth not exceeding 1.0M. (i) Using 38mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness. (ii) Using 25mm thick plank
(b) Floors etc. above 200mm in thickness (Using 38mm thick plank).
Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (b).Brick on edge soling
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement:4 sand)
200mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement morter of proportion 1: 5 including racking out joints and curing complete as directed in structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) (b) In Super structure above plinth level upto 1st floor level
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) (a) In Super structure above plinth level up to 1st floor level
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) (b) In Super structure above 1st floor level upto 2nd floor level
100mm thick wall using Cellular Light Weight concrete block of Size 500x200x100mm conforming to IS-2185 Pt-3 or pt-4 in cement mortar of proportion 1: 5 including racking out joints and curing complete as directed in super structure (protruding rod is to be provided at every 3 course interval and will be measured and paid separately) ( c) In Super structure above Terrace
Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make ii) Of size 600mmx600mm and above
b) Executive range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make i) Of size 800mmx800mm and above
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (1) 550mm x 550mm
Kota-stone slab flooring of 18 mm thick over 20mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (2) 600mm x 900mm and above
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (1) 550mm x 550mm
Kota stone slab of 18 mm thick in riser of steps, skirting, dado and pillars laid with 10mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs including rubbing and polishing complete. (2) 600mm x 900mm and above
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
Providing polished ceramic tiles of approved quality size, shape and thickness not leaa than 8mm on walls and skirting over cement mortar base 10 mm thick in prop 1:3 (1 cement: 3 coares sand) including cutting where necessary finished with flushed pointing with Fix A Tile(Choksey/Sika/Pidilite/Rouf, white cement slurry) mixed with approved pigment to match shadow of tiles complete at all levels as specified and directed.)cement, plastering to be measured and paid separatly) (color pigment should be in conformity with colour of tiles as approved and directed by the department) for both interior and exoerior walls.(c) Delux range Somany/ Orient/Nitco/Varmora Make ii) Of size 300mmx450mm and above
Providing polished ceramic tiles of approved quality size, shape and thickness not leaa than 8mm on walls and skirting over cement mortar base 10 mm thick in prop 1:3 (1 cement: 3 coares sand) including cutting where necessary finished with flushed pointing with Fix A Tile(Choksey/Sika/Pidilite/Rouf, white cement slurry) mixed with approved pigment to match shadow of tiles complete at all levels as specified and directed.)cement, plastering to be measured and paid separatly) (color pigment should be in conformity with colour of tiles as approved and directed by the department) for both interior and exoerior walls.(c) Delux range Somany/ Orient/Nitco/Varmora Make iv) Of size 300mmx600mm and above
Providing 18mm thick Granite slab on vertical face of pedestal laid over 10 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete as directed with approved quality of shade.
Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). (iii) Deluxe Quality (i) With Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed. a) On Single coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed. b) On two coat plaster
Extra over item no 6.2.1 to 6.2.3 for exterior plastering over wall for every addl floor or part thereof beyond 1st floor level(fron 1st floor to 2nd floor level) including curing complete as directed. b) On two coat plaster
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary). 12.5mm thick
Providing fitting and fixing of Mineral fibre Acoustic ceiling tiles of 600mm x 600 mm of 13/15 mm thickness to be placed in E - grid suspended ceiling grid 2430 system consisting of main runner 3600 mm long, cross Tee 1200 mm long/600mm long and wall angle. the wall angle shall be fixed on PVC dash fasteners on the perimeter of wall; by steel screws @ 300 mm c/c. Main runner shall be placed along the shorter dimension of the area to be covered. The distance between the 2 main runners to be maintained at 1200 mm. The cross Tee 1200 mm to be will be inserted in a pre cut slots of main runer at a regular interval of 600 mm to form a regular interval of 600 mm to form a modular grid of 1200mm x 600 mm. Additional cross Tees of 600 mm to be place perpendicular to the cross tee 1200 mm long to finally form a grid of 600mm x 600 mm. E - grid of modul;e size 600 mm x 600 mm shall be supported by 4/6 mm dia G.I wire from soffits mineral fibre acoustics ceiling tiles of Armstrong/US Boral/ Everest make to be placed in E- grid module to form a false ceiling including cuttings for light fittings as directed and specified using 13 mm thk perforated ceiling tiles.
Providing dressed wood work in post, walls,battens, post plate bressumers etc. includingsupplying and fixing with spikes, nails,bolt and nuts of 12mm dia(M.S) and required length etc.complete with kiricide oiling two coats to faces in contact with C.C or masonry (M.S flats, angle cleats and bolt and nuts required for flats,angle cleats wherever use shall be measured and paid separately) (a) With sal wood
Providing, fitting and fixing factory made Flush door shutters having core & cross bands fabricated from seasoned 1st class timber, 25mm core battens, 2.5mm to 3.5mm uniformly thick cross bands, styles & rails made from hardwood timber of width not less than 50mm, fixed to the door frames (chowkath) with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately.) THE FLUSH DOOR SHALL BE FINISHED WITH 1 MM LAMINATE ON BOTH SIDES AS PER APPROVED BRAND AND SHADE INCLUDING 400 X 400 CLEAR GLASS PANEL BY CUTTING THE FLUSH DOOR TO BE AOMPLETED AS PER DESIGN AND AS DIRECTED. (a) 30 mm thick
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws. (c) Fixed to Brickwork/P.C.C/R.C.C.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (i)6mm clear glass
(b) 3 Track sliding window (i)6mm clear glass
a) Providing, fitting and fixing anodised aluminium fixed windows and ventilators of standard sections of approved brand, joints mitred welded (manufactured to relevant I.S. specification) fitted with glass panes of required thickness and 12mm prelaminated boards and providing and fixing handles, angle cleat, rubber gusket,roller bolting device, screws as required complete as specified and directed for all levels. (a) In Normal anodised Aluminium section (i) With 6mm thick glass panes
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete etc complete as specified and directed by the department at all levels. (a) with 12 mm thick toughened glass
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) - Thickness = 1.5 mm thick
a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Extra for every subsequent coat of wall painting with acrylic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) - Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Applying one self-priming coat of acrylic emulsion coating of Unicem "Rakshak" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.
Finishing wall with two coats of acrylic emulsion exterior coatings of Unicem "Rakshak"/Asian Paints/ Berger paints brand of required shade by thinning 1ltr. of paint with 750ml of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.
Extra over item no.13.5.2 above for every subsequent coat of acrylic emulsion exterior coatings of Unicem 'Rakshak' brand of required shade.
Polishing with french sprit polishing on new wood and wood based surfaces to give an even surface including cleaning the surface of all dirt, dust sand papered smooth and including a coat of wood filter
Applying priming coat over new wood based surfaces up to 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt and other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white).
Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping. (ii).Surfaces up to 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Painting one coat (excluding priming coat) on old wood and wood based surfaces with enamel paint to give an even shade including cleaning the surface of all dirt, dust and other foreign matter sand papering and stopping. (ii).Surfaces up to 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Extra over item no13.6.5and 13.6..6 for every subsequent coat of paint. (ii).Surfaces up to 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. a). With ready mixed "red-lead/ red oxide" primer.
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (i).Surfaces over 100mm in width or girth. a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ). b) Tower bolts i) 300mm x 10mm
n) Mortice lockl vertical type ii) 75mm
v) Door stopper with rubber stopper
c) Door handles iii) 150mm
o) Mortice cylindrical type(Godrej make)-polished Brass
Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department. A) Godrej d) Sleek Door Closer( 215mm x 51mm x 45mm)
Providing,fitting and fixing Floor Spring of various weight & type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department A) Architectural Range b) Heavy duty Floor Spring D100 ( size 308mm x 108mm x40.5mm)
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars
Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.
Providing plinth protection with bricks laid on edge and grouted with cement mortar 1:4 and finishing with cement pointing in prop. 1:1 complete.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Supply fitting and fixing of Mac/Vista or equivalent make vertical blinds with necessary hardwares like runner channels etc with 100 mm width fabric blinds and as per choice and directed.
Supplying, providing, mixing and laying over waterproofing layers/ coatings with concrete screed of average 30mm thick or as per drawings/ requirements in proportion 1:2:4 (1cement : 2fine aggregate : 4coarse aggregate) (by volume) with 10mm and down well graded aggregates and admixed with a normal plasticizer like Master Plast PL-1 of Choksey Chemicals /Dr. Sealkit Normal Plast (Asian Chemicals)/Rheomac 707 of BASF @ 0.3% by weight of cement and thereafter scoring the top surface of the concrete screed @ 200mm c/c as specified and directed by the Department.
Providing modified clay cladding of approved quality, size, shape and thickness not less than 3 mm on external walls over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of stone, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Phomi make MCM Travertine 031Y of size 1200 x 600
Supplying, fabrication and fitting of stainless steel railing with 13.5 mm thick eva laminated glass as per approved design with SS 304 grade stainless steel post and top rail of 50 mm dia complete as directed.
Providing, supplying and fixing of Frameless Single leaf/double Swing Glass Door of Dorma/ Ozone or equivalent make in glazing using 12mm thick toughened glass of Saint Gobain / or approved equivalent with die cast patch fitting with stainless steel cover including fixing of patch fittings, floor springs, locks, handles etc. using the hardware items as detailed, complete in all respects as per detailed drawings, specifications and direction of Engineer in charge. Single Leaf Door with Dorma or Equivalent Hardware’s as specified:- Swing Glass Door which includes each of Top Pivot PT 24, Bottom Patch PT 10, Top Patch PT 20, Floor Lock US 10, Strike Plate , Floor Spring BTS 75v, with pair of TGDIH SS Pull Handle 25 mm dia x 450 mm long and other accessories for self closing feature as per detailed drawings. a) Double leaf door with (2.4m X 2.4M)
Providing fiting and fixing of Wood Plastic Composite (WPC) door frames of natural and brown colour of 100mm x 65 mm section and density not less than 900 kg/ cum, single rebated rectangular section including joining of top mullion and vertical members with mitred joint and fixing to the wall jamb with MS holdfasts/ Metal Screw and metal rawl plug.
Wiring for light/fan/bell point with 2 x 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring with 20 mm dia 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 6 Amps flush type switch/bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover as required complete, when placed elsewhere. Short point upto 3.0 m length
Wiring for light/fan/bell point with 2 x 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring with 20 mm dia 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 6 Amps flush type switch/bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover as required complete, when placed elsewhere. Medium point upto 6.0 m length
Wiring for light/fan/bell point with 2 x 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring with 20 mm dia 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 6 Amps flush type switch/bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover as required complete, when placed elsewhere. Long point upto 10.0 m length
Wiring to 5 pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Short point upto 3.0 m length
Wiring to 5 pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Medium point upto 6.0 m length
Wiring to 5 pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere. Long point upto 10.0 m length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Short point upto 3.0 m length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point upto 6.0 m length
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point upto 10.0 m length
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 3 x 4 sq mm + 2 x 2.5 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 6 sq mm + 2 x 4 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
With 4 x 10 sq mm + 2 x 6 sq mm earth connectivity in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof reversible Double door (IP-43) surface mounting horizontal TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (Schneider neo break, C&S, Havells, INDOASIAN, Standard, HPL or equivalent Make as approved by the Deptt.) 4 way TPN (8+12) double door
(Schneider neo break, C&S, Havells, INDOASIAN, Standard, HPL or equivalent Make as approved by the Deptt.) 6 way TPN (8+18) double door
(Schneider neo break, C&S, Havells, INDOASIAN, Standard, HPL or equivalent Make as approved by the Deptt.) 8 way TPN (8+24) double door
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted single door surface mounting vertical TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar up to 125A and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 8 way TPN (4+24) single door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
C Series (Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
3. D Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32
B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 40A
B Series (Schneider MG, legrand, Hager, Crabtree xpro make) 63A
C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 6 to 32
C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 40A
C Series (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 63A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 25A
100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 63A
25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian make) 80A
Supplying including and fixing of metal boxes in recessed system complete as per direction of department. Legrand/anchor/schneider or equivalent 1-2 module type metal
3 module flush type metal
4 module flush type metal
6 module flush type metal
8 module flush type metal
10 module flush type metal
12 module flush type metal
Supplying including fitting fixing of logic front plate of suitable colour as per direction of department. Legrand/anchor/schneider or equivalent 1 module type metal
2 module type metal
3 module flush type metal
4 module flush type metal
6 module flush type metal
8 module flush type metal
10 module flush type metal
12 module flush type metal
Supplying with fitting fixing 6 amp one way modular clip in switch in recessed system including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying with fitting fixing 16 amp one way modular clip in switch in recessed system with LED indicator including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation of socket outlet 6/16/13 Amps cInternational; socket with making necessary connection as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying with fitting fixing 10/16 amp one way modular clip in switch in LED in recessed system including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including fitting and fixing of rigid PVC. Conduit pipes including painting etc. complete in surface wiring system. 25 mm. Dia, 1.5 - 2.0 mm mm thick, rigid PVC. Conduit pipes
Supplying with fitting fixing blank plate single in modular switch recessed system with including making necessary connection complete as per direction of department. Legrand/anchor/schneider or equivalent
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1200 mm Sweep (ORIENT PSPO make) / Premium model 1050 / 1200 mm Sweep SS-390 Deco Havells make)
Supplying with fitting and fixing of electronic modular fan speed controller 2 - module type MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department. 100 watt electronic modular 4 step speed control 2 - module type
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Ventilator DX 250 mm sweep Louver type (ORIENT make), Brisk Air 250 mm sweep Louver type/ Trans Air 150 mm sweep (Crompton make), Ventil Air DX 150 mm sweep Louver type (Havells make)
Installation, testing and commissioning of ceiling fan including the regulator /down rod of standard size (Up to 300 mm ) length including connection as approved by the Deptt.)as required.
Supplying extra down rod of 10 cm long G.I. pipe 20 mm dia heavy gauge including painting etc. as required
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx6 mm heavy duty copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 Kg and Charcoal 96 Kg in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 25x5 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying, Fabrication, Erection , Testing commissioning of vermin and dust proof (IP-43 protection) totally enclosed cubical type compartmental floor mounting panel board of size 1200mm x 1600mm x 500mm made of 16 SWG1.66mthick C.R. sheet and 30mm x 30mmx5mm size angle having 4 nos legs at the bottom and C.R. sheet roofing on the top complete with 2 coats of Red Oxide metal primer and painting with powder coated paint. The panel board is to be erected in 1 :3:6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 125A 4 pole MCCB as Incomer and provision for 6 Nos. DP or 4 Nos. TPN out going as specified and directed by the deptt. comprising of the following electrical items : 0-125A (Digital) Ammeter 1 0- 500V (Digital) Voltage 1 Ammeter S/S in 3 positions 1 Voltmeter S/S in 3 positions 1 Indicators Lamps (R,Y, B) 3 Cut out 3 CT's 5/125 3 Control Wiring 1 Incoming and Outgoing MCCB/MCB will be paid extra.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 3 & 1/2 Core A2XFY 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
35.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
50.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Power/Control Copper cables, Solid Copper conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Unarmoured/Armour (Galvanised for cables up to 10 x 1.5 sq mm.8 x 2.5 sq mm.2 x 10 sq mm.3 x 10 sq mm.4 x 6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 Sheathed, 650/1100 V grade as per IS 7098 (Part 1) 1988, U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or equivalent) . 3 core A2XWY A2XFY 4.00 Sq.mm 3 Core armoured U.G. cable
3 core A2XWY A2XFY 6.00 Sq.mm 3 Core armoured U.G. cable
4 Core, 2XWY 2XFY 4.00 Sq. mm.4 Core U.G. armoured cable
4 Core, 2XWY 2XFY 6.00 Sq. mm.4 Core U.G. armoured cable
4 Core, 2XWY 2XFY 10.00 Sq. mm.4 Core U.G. armoured cable
Supply and laying 11/33 KV HT 3 core Stranded compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting compound, XLPE Insulated, Insulation Screening with truded Semi Conducting compound in combination with Copper Tape (0.3kA for 1 se , cores laid up, inner sheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed cable conforming to IS 7098 / (PART-I 1985 with latest amendment cable laid through medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) / partially in air as required for connection as directed, including excavation of trench, refilling reconstruction of damaged done to road, drain, wall et as specified by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 95mm 3 Core armoured 11 KV (H.T. U.G. cable laid through 100mm dia hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.) )
Supplying and fixing of Jaquar or equivalent recessed mounted LED downlighter with aluminium die cast housing fittings complete with Shade, back plate including connection cable, as approved by the Deptt.s etc. as required. LED 9W (CAT NO NERO Square LNRO01S009XC)
LED 12W (CAT NO NERO Square LNRO01S012XC)
LED 18W (CAT NO NERO Square LNRO01S018XC)
Providing fitting and fixing Vitreous china Dual Flush / Floor Mounted Coupled / Extended water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately) B) Hindware make a) White 1) Extended Type (vii) Studio (inclusive of seat cover and fittings) (Cat. No. 20058) (P Trap)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. (B) Hindware Make (a) White (ii) Dyna (Cat. No.60010)
Supplying fiting and fixing vitreous china division plate including fitting and fixing compete as directed and specified. (ii) Hindware Make (a) White (ii) New Division Plate (Cat. No.61005)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) Under Counter Basin (B) Hindware Make (a) White (i) Lara (Cat. No.10095)
Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately (A) Parryware Make (i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545)
Providing fitting and fixing Decorative Mirror complete as directed and specified. (A) Parryware Make (a) Size 800mm x 600mm
Providing, fitting and fixing CP soap tray / soap dish complete as directed and specified. (i) Jaquar Make (a) Continental (Cat.No.ACN-1331N)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (a) Jaquar make (i) Continental towel ring square (Cat.No. ACN-1121)
Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified. (a) Jaquar make (i) Continental (Cat.No. ACN-1191N)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (a) Jaquar Make (i) 32mm (HT/FT) (Cat.No.ALD-705 / 709)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (a) Jaquar make (i) Bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe (Cat.No. ALD-769)
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (i) 160mm dia. PVC cowel of ISI make
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (ii) 110mm dia. PVC cowel of ISI make
C.P. Grating (i) 160mm dia
C.P. Grating (ii) 110mm dia
Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Providing fitting and fixing (600x600)mm 90mm thick C.I. Man hole cover and frame of 25 Kg. weight complete as directed and specified
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia.
(ii) 110mm dia.
(iv) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm dia.
(ii) 110mm dia.
(iv) 75mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 160mm dia
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm
(ii) 75 mm x 75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110 mm dia
(iii) 75 mm dia
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm x 110 mm
(iv) 110 mm x 75mm
Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 160mm x 110 mm
(iii) 110 mm x 75mm
Providing fitting and fixing of Chlorinated Polyvinyl Chloride (CPVC) Pipes having thermal stability for hot and cold water supply with all necessary plain and brass threaded fittings and fixing the pipes with clamps at 1.0 m interval including jointing of pipe. (B) Concealed pipe with cutting chases & making good the walls b) 20 mm nominal outer dia pipe
c) 25 mm nominal outer dia pipe
d) 32 mm nominal outer dia pipe
f) 50 mm nominal outer dia pipe
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified. (G.I. & C.P pipes will be measured separately) (II) Jaquar make (a)Continental /Clarion (ii) Bibcock long thread
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand as directed and specified. (G.I. & C.P pipes will be measured separately) (iii)2-Way bib cock
Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) Jaquar (ii) 15mm dia( Angular stop cock with long thread )
Jaquar (iii) 15mm dia(Concealed stop cock reduced body )
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. (II)Jaquar make (a) pressmatic CAT no PRS-031
Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) (V)Jaquar brand a) Continental / Clarion i) Sink cock with swinging casted spout
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. a) 50mm dia
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. b) 40 mm dia.
Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid separately). 2000 Lt capacity water tank
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Mark and CO2 Cartridge will be confirming to IS: 4947 with ISI mark, (AFFF) will be confirming to IS: 4989 with ISI Mark.(9 LTRS) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
UTPAL JYOTI KALITA
Art E Mide Construction Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .