DGQA MEG CENTRE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO JOINERY PLUMBING, FLOORING AND REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES IN MD OTM ACCN BLDGS AT DGQA AREA UNDER GE NORTH BANGALORE
2021_MES_493035_1
8268
Open Tender
Civil Works
Item Rate
120 days
DGQA AREA
Class E category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹20,000
Yes
4 Jan 2022
7 Dec 2021
29 Dec 2021
7 Dec 2021
27 Dec 2021
15 Dec 2021
7 Dec 2021 - 14 Dec 2021
Amount
PART I (B/R WORKS)
Taking down chowkat or frames with shutters (without taking off shutter from the frame) area not exc 1.5 sqm each all as specified and as directed.
All as per Sl Item No. 1.001 above but area exc. 1.5 sqm and n. exc. 4 sqm each.
Taking down shutters of any description area n.exc. 1 sqm each all as specified and as directed.
Taking down shutters of any description area exc. 1 sqm but not exc. 2 sqm each all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chambered, put together with glue pinned at joints complete all as specified and directed.
PVC solid door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening as per specification & drawing.
Factory made solid PVC moulded door shutters, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specification & drawing.
35mm thick plain framed panelled factory made shutters with II class hardwood rail and style with lock rail and panel of 9mm BWP commercial ply with commercial vaneer on both faces. The size of rail and stile as per IS : 1003 (Part-I)1991 kiln seasoned and chemically pressure treated wood fixed to chowkats complete all as specified and as directed.
35 mm thick factory made 2nd class hard wood glazed and skeleton door shutters, open rebated and prepared to receive glass, gauge etc divided into squares with plain chamfered, mitred and rebated sash bars any numbers fitted with cut and mitred beads for securing glass etc complete all as specified and as directed.
Factory made flush door shutters 35mm thick,as per IS:2202 (Part-I 1999) solid core construction, with block board core and plywood face panels, commercial type on both sides including providing teak wood beading as per drawing and painted to match the door, fixed to chowkhats all as speified and directed.
Steel windows of box type, with frame of 80 x 60mm and1.25mm profile sheet with box type shutters consisting of inside glazed shutter and out side gauged shutter with steel handle, telephonic peg stay complete with glazing bars of 08 Nos with 10 x 10mm mild steel square guard bars in equal spacing, devotailed or welded all as per TD Drg No. 539 sheet 1/3 to 3/3 including filling frame with PCC (1:3:6) type C0 using 12.5 mm graded stone aggregate, 4mm thick sheet glass and 0.36mm stainless steel wire cloth complete all as specifeid and as directed. NOTE:- (i) Any brick work or concrete surface damaged during the process or work shall be repaired by contractor. (ii) The unit rate quoted shall deemed to be include the cost of scaffolding/staging etc., PCC in frame, glass pane and wire mesh as reqd.including one coat of red oxide primer all as specified and directed.
All as per Sl Item No. 1.012 here in before but steel ventilators with top hung double shutters all as specified and as directed.
Mild Steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as directed.
Rolled mild steel framed work (Fe 410 -W (Gde E- 250) quality A as in doors or gates of angle or other sections with gusset plates, rails braces, etc complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including preparation of surface and painted with one shop coat of zinc chrom primer at contractor's workshop / factory before fabrication complete all as specied and as directed.
Plain Cement Concrete, (1:2:4), type B0, using 12.5mm graded stone aggregate as in copings including necessary form work complete all as specified and directed.
Butt hinges, medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed.
Butt hinges, medium weight, cold rolled mild steel 75mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed.
Aluminium anodized barrel tower bolt of extruded section of size 200mm long complete all as specified and as directed.
Aluminium anodized barrel tower bolt of extruded section of size 150mm long complete all as specified and as directed.
Aluminium anodized barrel tower bolt of extruded section of size 100mm long complete all as specified and as directed.
Aluminium alloy anodised, length of bolt 300 mm sliding door bolt with hasp, staple(bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium and fixed all as specified and directed.
Extruded Aluminum handles 150mm size, fabricated type, anodised all as specified and as directed.
Extruded Aluminum handles 100mm size, fabricated type, anodised all as specified and as directed.
Mortice lock with four lever brass body 100mm size suitable for 25 to 60mm thick doors including screwing and fixed in repairs all as specified and as directed.
150 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed.
Magnet door catcher made out of stainless steel complete all as specified and directed.
Rubber door buffer of 125mm size fixed with brass screws complete all as specified and directed.
Eye doors viewer(Magic eye) made out of stainless steel complete all as specified and directed.
Mild steel sliding door bolt 300 mm long, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
Mild Steel pressed handles oval type, stove enameled black, 150mm size complete fixed all as specified and as directed.
Door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (Die cast body) fixed in repairs complete all as specified and as directed.
Mild steel 300mm long, ordinary rat tail rod pattern springs,including roller and roller plate complete all as specified and as directed.
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified.
PTMT door handle, 150 mm long and fixed with steel screws complete all as specified and as directed.
Galvanized mild steel wire cloth 0.56mm nominal dia and average width of aperture 1.18mm and fixed with tinned tack or galvanized wire staple all as specified and as directed.
All as per Sl Item No. 1.036 above but fixed in repairs.
Hacking out old broken glass of any thickness, size, quality or description from metal / wooden frame works or stone / concrete/ brick surrounds including punching or drilling out old glazing pins / spring clips or fixed with wooden beading etc complete all as specified and as directed.
4.0 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 sqm in each pane all as directed.
4.00mm thick figured glass, pin headed type and glazing with oil putty in squares n exc 0.5 sqm in each pane all as specified and as directed.
19 mm thick (7 Nos of ply) plywood grade BWP, type BB with decorative laminate type 1 of surface finish, having 0.9 mm thick , colour and pattern as approved, fixed with approved adhesive as per manufactures instructions, fixed with screws to timber frame work,alround 6mm thick teak fillets fixed in kitchen cabinet or cupboards complete all as specified and as directed.
100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws,fixed in repairs complete all as specified and as directed.
Continuous (piano) hinges, 40mm width of flaps (when open), mild steel bright finish or electro galvanised fixed to wooden or angle iron frame complete all as specified and as directed.
40mm dia, cupboard knobs fixed with nut, screw and washers of mild steel, bright finished including taking down old knobs complete all as specified and as directed.
Drapery rods, 25 mm dia, having corrugated PVC extrusion on electric resistance welded MS pipe with fancy type 02 nos knob and 02 nos brackets for each door/windows etc complete all as specified directed.
Taking down cement plaster on brick / stone / concrete surface including wall tiling or terrazo finish and hacking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
Renewing tiles in patches area n.exc 5.00 Sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new ceramic tiles to match the existing floor including 20mm thick screed bed of cement mortar (1:4) complete all as specified and as directed.
Forming jambs etc., to openings including toothing and properly bonding into old brick work also facing jointing and pointing to match existing work in CM(1:6) complete all as specified and as directed.
Making good under cills or over arches, lintels and bressummers including all pinning when necessary in CM (1:4) complete all as directed.
15mm thick rendering on brick or concrete surface in cement mortar (1:6) and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and as directed. NOTE:- WPC will be measured and paid separately under reelvent items.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper over a coat of alkali reistant primer on wall complete all as specified and directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer all as specified and as directed.
Preparation of new or previously untreated wooden surfaces of any description not other wise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the the premises complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick(square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including backing coat 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Taking up or down 15 mm dia existing steel tubing and connections all as specified and as directed.
Taking up or down 20 mm dia existing steel tubing and connections all as specified and as directed.
20mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
25mm dia CPVC pipes SDR 11 and plain CPVC SDR 11 fittings, fixed to wall, ceiling or laid in floors including all fittings and specials complete all as specified and as directed.
Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover, and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, fixed as in repairs, complete all as specified and as directed.
Vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including PVC(SWR) 'P' or 'S' trap connecting to flush pipe and to anti syphonage pipe, etc. complete including making good to floor fixed in repairs complete all as specified and directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
Vitreous china wash basin, white, flat back of size 630 X 450 mm excluding taps,chain and plug and porcelain stopper but including CI bracket. etc complete fixed in repairs complete all as specified and as directed.
PVC connections 15mm dia with PTMT nuts of length of 450 mm long complete all as specfied and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) fixed in repairs complete all as specified and as directed.
15mm bore Bib taps, cast copper chromium plated, fancy type, screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs complete all as specified and as directed.
15mm bore two way bib cock with angle valve combination, brass chromium plated, fixed in repairs complete all as specified and as directed.
Bib taps 15mm dia, chromium plated long body with CP flange fixed in repairs complete all as specified and as directed.
15 mm dia cast copper alloy chromium plated Pillar tap fancy type screwed for iron pipe and fixed in repairs complete all as specified and as directed.
PTMT waste coupling (half or full threaded) (Minimum weight 32mm-45gms) 32mm dia of discharge pipe complete fixed in repairs all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position on roofs including fittings and dismantling existing water storage tank complete all as specified in SSR part I capacity of tank 500 ltrs complete fixed in repairs all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position on roofs including fittings and dismantling existing water storage tank complete all as specified in SSR part I capacity of tank 1000 ltrs complete fixed in repairs all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position on roofs including fittings and dismantling existing water storage tank complete all as specified in SSR part I capacity of tank 2000 ltrs complete fixed in repairs all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) fixed in repairs all as specified and as directed.
Brass CP wall mixer 15mm dia for mixing hot and cold water screwed down for iron pipe and fixed in repairs complete all as specified and directed.
Angle cock,15mm dia CP cast copper alloy screwed down high pressure with capstan head handle screwed both ends or for unions etc., complete fixed in repairs all as specfied and as directed.
Stop valves, 15mm dia, cast copper alloy, chromium plated, screwed down high pressure with crutch or butter fly handle screwed both ends or for unions etc., fixed in repairs complete all as specfied and as directed.
Brass chromium plated overhead shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union, fixed in repairs complete all as specified and as directed.
15mm dia bib taps, PTMT, fancy type any colour screwed for iron pipe, fixed in repairs complete all as specfied and as directed.
15mm dia concussive push button taps of cast copper alloy, chromium plated, screwed down, screwed for iron pipe suitable for urinals fixed in repairs complete all as specified and as directed.
32mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
40 mm dia waste fittings, brass, chromium plated for sinks, basins, etc with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 40mm dia, 800mm long fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 32mm dia, 800mm long fixed in repairs complete all as specified and as directed.
Health faucet, brass body, chromium plated with 1mtr SS braided rubber hose pipe & wall hook fixed in repairs complete all as specified and as directed.
Taking down existing bib taps, Pillar taps, stop cock or angle valve of any size and re fixing in old or new position including replacing one nylon washer complete all as specified and as directed.
All as per Sl Item No. 1.091 here-in-before but replacing brass spindle.
75mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints fixed to walls with PVC clamps including necessary fittings fixed in repairs all as specified and as directed.
110mm bore PVC (SWR) pipe, type 'B' , single socketed in any length with rubber ring joints fixed to walls with PVC clamps including necessary fittings fixed in repairs all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
75 mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
110 mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
Providing and laying water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions. Contd.. 1.100
Contd.. 1.099 (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using 40mm graded stone aggregate. NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered. (v) mode of measurement : plan/floor area will be measured.
PART II (E/M WORKS)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., complete and making good the disturbed surface of walls, ceiling etc., including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete concealed with 1.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked including accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.for one light point controlled by one switch.
All as per Sl Item No. 2.002 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.002 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.002 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.002 here in before but for one 3 pin socket out let 5 Amps on same board.
Point wiring complete concealed for modular type switch & sockets with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring includign GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one light point controlled by one switch.
All as per Sl Item No. 2.008 here in before but for one fan point controlled by one switch/regulator
All as per Sl Item No. 2.008 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.008 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.008 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring complete surface type with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed one light point controlled by one switch.
All as per Sl Item No. 2.014 here in before but for one fan point controlled by one switch/regulator.
All as per Sl Item No. 2.014 here in before but for one light point controlled by 2 way switch.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 2.014 here in before but for one bell/buzzer point controlled by bell push.
All as per Sl Item No. 2.014 here in before but for one 3 pin socket out let 5 A on same board.
Point wiring concealed complete with 2.5 sq.mm single core PVC insulated unsheathed 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet, concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring (modular) complete concealed with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Point wiring complete surface type with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and incl non-metalicPVC casing caping ISI marked with accessories concealed wiring incl GI/ MS branded sunken boxes of suitable moodule concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR Sl ITEM NO. 2.002 to 2.022 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten suitable for indoor applications 18/20 Watts,4 feet with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830192 18W CDL/ Havells Cat No: LHEXAPP7IN1W020 / C&S Cat no: LTTB4F20W LED EW BATTEN complete all as specified and as directed.
LED batten suitable for indoor applications 10 Watts, 2 feet with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories including taking out old fittings all as per Bajaj, Cat No.830206 10W CDL/ Havells Cat No: LHEXACP5IN1W010 of Havells / C&S Cat No:LTTB2F 10WLEDW BATEN all as specified and as directed.
Bulk head fittings of 10 watt, IP -65 type luminaries complete with all accessories including taking out old fittings all as per Bajaj Cat No: BIPWP 10 W LED of BAJAJ or or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Modular switch 1 way, 6 Amps, one module complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module complete all as specified and as directed.
Modular switch 2 way, 6 Amps, one module complete all as specified and as directed.
Modular bell push, 1 way, 6 Amps, one module complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module complete all as specified and as directed.
Switch piano flush button single pole two way 5 Amps with ISI marked complete all as specified and as directed.
Angle holder PVC/polycarbonate type all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Bell push flush type, one way 5 Amps all as specified and as directed.
MCB single pole and neutral 240 Volts, 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 6 to 32 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 32 to 63 Amps including taking down the existing complete as specified and as directed.
MCB DB SPN 8 way 240 volts, double door, with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated busbar for housing MCBs including taking down the existing complete as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
Stepped type electronic fan regulator flush switch type including taking down the existing complete as specified and as directed.
Ding dong bell AC 230 volts single pole including taking down the existing complete as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable 2 single core of size 4 sq.mm, earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC conduit of suitable size, medium grade concealed in walls/roof/floors including taking down the existing wiring complete all as directed. NOTE:- Two wires of 4 sq.mm and one wire of 4 sq.mm and one run of PVC conduit shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
30 Watt LED building security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings all asper Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or techno commercially equivalent makes specified in PS complete all as specified and as directed. .
Brackets made out of GI tubing medium grade 25 mm bore, approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and as directed.
PRANAVI CONSTRUCTION
SP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .