Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | Admitted-Finance |
| 2 | Admitted-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
11 Jan 2022, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA
ELECTRICAL RENOVATION/UPGRADATION OF COMPUTER LAB AND INTERNAL WIRING OF SCHOOL BUILDING OF KV NO 01 AT AF STN SIRSA
2021_MES_494649_1
GE/SRA/T-58 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
93 days
GE (AF) SIRSA
As per Tender and NIT
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹10,000
Yes
14 Jan 2022
14 Dec 2021
13 Jan 2022
14 Dec 2021
11 Jan 2022
28 Dec 2021
14 Dec 2021 - 23 Dec 2021
Amount
Taking down Copper/Aluminium Point Wiring any type including PVC casing caping /PVC Conduit (Light, Fan, Socket or Power) excluding Fixture and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description and Making Good Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Taking down/out unserviceable Wires only from the existing Sub-main Wiring of any type and any description, without disturbing Existing Conduit, complete all as specified and as directed.
M&L for Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT/ BELL POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed.
M&L for Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT CONTROLLED BY ONE 2-WAY SWITCH 6 AMP, complete all as specified and as directed.
M&L for Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, providing PVC Gang Box (minimum 2.0mm thick)/Sunk Mild Steel Pressed Terminal Box (1.6mm thick) of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover (as per Site requirement) for mounting Switches, Sockets, Fan Regulators, etc. Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in CONDUIT complete all as specified and as directed.
M&L for Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in CONDUIT complete all as specified and as directed.
M&L for Sub-main Wiring with 4-Runs of 16.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 16 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in CONDUIT complete all as specified and as directed.
M&L for Sub-main Wiring with 4-Runs of 10.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 10 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in CONDUIT complete all as specified and as directed.
S&F in repairs Switch Piano 6 Amp, Flush type, Single Pole, 1-way and , complete all as specified and as directed.
S&F in repairs Switch Piano 16 Amp, Flush type, Single Pole, 1-way , complete all as specified and as directed.
S&F in repairs Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin , complete all as specified and as directed.
S&F in repairs Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 6 Pin, complete all as specified and as directed.
S&F in repairs Bell Push Button 6 Amp, Flush type suitable for Call Bell, complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body and Fixing-in-repairs, complete all as specified and as directed.
S&F in repairs PVC rectangular block with sunk mild steel pressed terminal boxes with 1.6 mm thick junction box for mounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 200 x 150 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs PVC rectangular block with sunk mild steel pressed terminal boxes with 1.6 mm thick junction boxmounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 250 x 200 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs PVC rectangular block with sunk mild steel pressed terminal boxes with 1.6 mm thick junction box for mounting switches,sockets,fanregulator etc with 3 mm thick plastic laminated sheet cover of size up to 350 x 300 x 50 mm including cutting for mounting of switches and sockets, complete all as specified and as directed by Engineer-in-charge.
S&F in repairs Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F MCB Single Pole, 6 to 32 Amp (as directed), 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up , complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up , complete all as specified and as directed.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 63 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded/Concealed upto Wall surfaces including Connecting up with Existing Cable Incoming and Outgoing with Cable lugs as per the Site requirement and and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to Match with the Existing Finishes , complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole with a 2-Pin and Earth Plug and Socket with and including 1 No. MCB Single Pole, 32 Amp, 240 Volt and Connecting up including , complete all as specified and as directed.
S&F MCCB 4 Pole, 415 Volt, Adjustable type, 100 Amps with breaking capacity 25 kA including Connecting up , complete all as specified and as directed.
S&F Load Line DB 4-way Enclosure Double Door with MCCB 100 Amp rating, 16 kA, 4 Pole and suitable for 415 Volt 50 Hz AC Supply including Connecting up and Fixing-in-repairs, complete all as per specified and directed.
S&F MCB TP 63 Amp, 440 Volt, AC, 'C' Series for fixing on MCB DB’s, including Connecting up, complete all as specified and as directed.
S&F MCB 4P 63 Amp, 10 KA 440 Volt, AC, for fixing on MCB DB’s, including Connecting up, complete all as specified and as directed.
S&F TPN MCB DB -4 way including Connecting up, complete all as specified and as directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying of Cable and getting out soil including forming bottom surface to required level and gradient in Soft/ Loose Soil and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 m and depositing where directed at a level not exc. 1.50 Metre above the starting point, complete all as specified and as directed.
Supply & laying in trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
M&L for Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
M&L for XLPE insulated screened PVC bedded,gakvanised steel strip or wire armoured electric power cable earthed(heavy duty) Conductor Multi Stranded, 1100 Volt grade, with stranded aluminium conductor 3.5 core 50 sq, marked IS : 7096 laisd in trenches,duct,through pipe,in floor .on pole/wall including jointing and Testing, complete all as specified and as directed.
BHATIA ENTERPRISES
NISHTHA BUILDERS
M/s Shree Bala Ji Construction Company
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .