| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹35.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹35.7 L+₹2,907 (0.08%)Rejected-Finance 02 RUDIA BIT MESRA ROAD NEORI VIKAS RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | ₹35.7 L+₹2,907 (0.08%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹41.8 L+₹6.1 L (17.2%)Rejected-Finance | ₹41.8 L+₹6.1 L (17.2%) | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Raj Construction L1 | THE SUVASH AND SONS L2 | M/S SAPPHIRE BLU INFRA L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply,laying,jointing,testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 185 sqmm 3.5 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
Note:- Excavation and earth work will be measured and paid separately. | 736 | RM | 1,468 ₹10,80,448 Lowest | 1,500 ₹11,04,000 | 1,760 ₹12,95,360 |
| 2.00 | Description all as per Ser item No 1 above here-in-before but of size 70 sqmm x 3.5 core | 460 | RM | 645 ₹2,96,700 | 630 ₹2,89,800 | 621 ₹2,85,660 Lowest |
| 3.00 | Description all as per Ser item No 1 above here-in-before but of size 50 sqmm x 3.5 core | 550 | RM | 439 ₹2,41,450 Lowest | 450 ₹2,47,500 | 475 ₹2,61,250 |
| 4.00 | Description all as per Ser item No 1 above here-in-before but of size 25 sqmm x 4 core | 700 | RM | 290 ₹2,03,000 | 250 ₹1,75,000 Lowest | 280 ₹1,96,000 |
| 5.00 | Description all as per Ser item No 1 above here-in-before but of size 16 sqmm x 4 core | 650 | RM | 250 ₹1,62,500 | 220 ₹1,43,000 | 185 ₹1,20,250 Lowest |
| 6.00 | Supply and fix LT overhead lines XLPE insulated aerial bunched (AB) cable 3 core x 95 sqmm (insulated phase conductors) + 1 core x 70 sqmm (bare neutral messanger conductor) as per IS 14255 (1995) for working voltage upto 1100 volts on existing 09 mtr LT steel tubular poles complete all as specified.
Note :- Necessary Hook clamp & dead end clamp ect. for cable hanging deemed to be included in quoted rates. | 40 | RM | 1,000 ₹40,000 | 900 ₹36,000 Lowest | 1,470 ₹58,800 |
| 7.00 | M & L for Erection in vertical position steel tubular sewage pole (ISI market) with cast iron base plate, final taper plug, bolts, nuts & screws etc, type 410-SP-31 (09 Mtr long) confirming to IS 2713 part 1 to 3) 1980 including two coats of black bituminous paint throughout internally and externally upto planting depth and two coats of synthetic enamel paint of alternate black and red strips, 30 cm high over one coat of red oxide primer upto 1.5m height from ground level/coping. The remaining portion shall be painted with two coats of aluminium paint over coat of red oxide primer complete all as specified and directed. Note : Necessary earthwork, PCC shall be measured and paid for separately.. | 2 | Each | 15,000 ₹30,000 Lowest | 15,500 ₹31,000 | 19,700 ₹39,400 |
| 8.00 | Supply and fix anchoring clamp suitable for cable size 95 sqmm with Al. alloy bracket, stainless steel strap, buckles, eye hook incl nuts bolts and washers complete all as specified. | 4 | Each | 500 ₹2,000 Lowest | 2,500 ₹10,000 | 1,680 ₹6,720 |
| 9.00 | Supply and fix fire retartdant engineering thermoplastic (PC) 3 phase distribution box of size not less than 275x310x210mm IP65 rated, with spring loaded or aluminium strip bus bar connection of incoming cable LT XLPE cable with AB cable including bracket/clamps, buckles, eye hook, nut-bolts and washers complete all as specified. | 2 | Each | 1,500 ₹3,000 | 1,500 ₹3,000 | 780 ₹1,560 Lowest |
| 10.00 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed. | 451 | Cum | 150 ₹67,650 Lowest | 160 ₹72,160 | 225 ₹1,01,475 |
Tender Value
₹38.9 L
EMD Value
₹78,000
Closing Date
13 Aug 2026, 6:00 pmClosed
Shri Manjul Kumar Tripathi, GE
Garrison Engineer Ranchi Military engineer Services 7th club road Ranchi
AUGMENTATION OF ACSR LT OVERHEAD LINE CONVERSION UG CABLE ALONG WITH CONTROL PANELS AT ENGINEER LINE AND KURUKSHETRA LINE AND OTHER POCKET AT LPH AREA UNDER GE RANCHI
2026_MES_778995_1
8400/1306/E8
Open Tender
Civil Works
Item Rate
180 days
GE Ranchi
Class D Cat b (i)
7 documents required · 7 mandatory
₹500
GE Ranchi
₹78,000
Yes
16 Sept 2026
16 Jul 2026
20 Aug 2026
16 Jul 2026
13 Aug 2026
30 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply,laying,jointing,testing and commissioning XLPE insulated, armoured, heavy duty, LT UG cable with aluminium conductor,1100 volts grade cross sectional area 185 sqmm 3.5 core connected with aluminium lugs connected by cramping tools all as specified and directed at site.
Note:- Excavation and earth work will be measured and paid separately. | 736 | RM | - | - |
| 2 | Description all as per Ser item No 1 above here-in-before but of size 70 sqmm x 3.5 core | 460 | RM | - | - |
| 3 | Description all as per Ser item No 1 above here-in-before but of size 50 sqmm x 3.5 core | 550 | RM | - | - |
| 4 | Description all as per Ser item No 1 above here-in-before but of size 25 sqmm x 4 core | 700 | RM | - | - |
| 5 | Description all as per Ser item No 1 above here-in-before but of size 16 sqmm x 4 core | 650 | RM | - | - |
| 6 | Supply and fix LT overhead lines XLPE insulated aerial bunched (AB) cable 3 core x 95 sqmm (insulated phase conductors) + 1 core x 70 sqmm (bare neutral messanger conductor) as per IS 14255 (1995) for working voltage upto 1100 volts on existing 09 mtr LT steel tubular poles complete all as specified.
Note :- Necessary Hook clamp & dead end clamp ect. for cable hanging deemed to be included in quoted rates. | 40 | RM | - | - |
| 7 | M & L for Erection in vertical position steel tubular sewage pole (ISI market) with cast iron base plate, final taper plug, bolts, nuts & screws etc, type 410-SP-31 (09 Mtr long) confirming to IS 2713 part 1 to 3) 1980 including two coats of black bituminous paint throughout internally and externally upto planting depth and two coats of synthetic enamel paint of alternate black and red strips, 30 cm high over one coat of red oxide primer upto 1.5m height from ground level/coping. The remaining portion shall be painted with two coats of aluminium paint over coat of red oxide primer complete all as specified and directed. Note : Necessary earthwork, PCC shall be measured and paid for separately.. | 2 | Each | - | - |
| 8 | Supply and fix anchoring clamp suitable for cable size 95 sqmm with Al. alloy bracket, stainless steel strap, buckles, eye hook incl nuts bolts and washers complete all as specified. | 4 | Each | - | - |
| 9 | Supply and fix fire retartdant engineering thermoplastic (PC) 3 phase distribution box of size not less than 275x310x210mm IP65 rated, with spring loaded or aluminium strip bus bar connection of incoming cable LT XLPE cable with AB cable including bracket/clamps, buckles, eye hook, nut-bolts and washers complete all as specified. | 2 | Each | - | - |
| 10 | Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed. | 451 | Cum | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Tender1306.pdf
Tender Documents • 0.49 MB
BOQ_872516.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .