| 1 | L1₹48.5 LAccepted-AOC SRIKONA POTAPOLA CHHAKA CHANDIPUR ROAD BALASORE ODISHA 756025 | BALASORE | BALASORE | ODISHA | 756025 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹51.3 L+₹2.8 L (5.80%)Rejected-Finance GUDUPAHI CHANDIPUR BALASORE ODISHA 756025 | CHANDIPUR | BALASORE | ODISHA | 756025 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹51.4 L+₹2.9 L (5.93%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹55.0 L+₹6.5 L (13.4%)Rejected-Finance AT SRIKONA PS CHANDIPUR DIST BALASORE ODISHA 756 025 | CHANDIPUR | BALASORE | ODISHA | 756025 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹55.9 L+₹7.4 L (15.3%)Rejected-Finance PASCHIM BHAGABANPORE DARUA CONTAI PURBA MEDINIPUR 721401 | PURBA MEDINIPUR | PURBA MEDINIPUR | WEST BENGAL | 721401 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE I R AND D CHANDIPUR Post Chandipur PIN 756025
PROVISION OF ADDITIONAL ROOM WITH ALLIED FACILITY AT BLDG NO P-35 BALASORE
2023_MES_582445_1
8805/CDP
Open Tender
Civil Works
Item Rate
180 days
Balasore
As per Tender documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹93,000
Yes
31 Mar 2023
23 Feb 2023
16 Mar 2023
23 Feb 2023
14 Mar 2023
9 Mar 2023
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. SCHEDULE 'A' PART-I (B/R PORTION)
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil.
Excavation in trenches, n exc 1.5 m wide and exc 1.5 m and n exc 3.0m in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil.
Boring for Bored cast in situ piles 375mm dia,10 metres length from cut off level in soil and getting out and disposal of soil to a distance 50 metres using DMC method (Direct mud circulation) all as specified and directed by Engr-in-Charge.
Testing of Piles (both test pile and working pile) as per latest IS provision including boring, reinforcement and concreteing of 01 test pile (375mm dia and 10m depth from cut off level) all as specified and directed by Engr-in-Charge. (Cost of boring, reinforcement and concreteing shall included in one test pile)
M&L for PCC (1:4:8) type D-2 using 40 mm graded aggregate in foundation, filling and mass concrete
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions. square, rectangle or polygon (Superstructure)
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Formwork to chullah hoods, chajjas, troughs and similar items including edges
Formwork to sides and soffits of floor or roof beams, beam haunch?ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for piles 375 mm dia RCC M-30 (Design mix) as in bored pile 10 m length from cut off level all as specified and directed by Engr-in-Charge.
M&L for RCC, M-30 (Design mix) as in foundation, pile cap, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slab, under mass concrete all as specified and directed.
M&L for RCC, M-30 (Design mix) as in column, pillars, piers, posts and struts. (Substructure & Superstructure) all as specified and directed.
M&L for RCC, M-30 (Design mix) as in slabs supported on walls, beams and column in floors, roof, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M&L for RCC, M-30 (Design mix) as in chajjas all as specified and directed.
M&L for RCC, M-30 (Design mix) as in beams, cantilevers, bressumers, lintel over 1.5 mt span all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25cm Soft soil/loose soil
M&L for sand filling under floors or in foundations including watering and consolidation
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M&L for mild steel TMT bars (Fe 500D) 10 mm dia and over, cut to length, bent to shape requied, including cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips
M&L for mild steel TMT bars (Fe 500D) 6 to 8 mm dia, cut to length, bent to shape requied, including cracking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9 mm dia or securong with clips
M&L for mild steel TMT Bars (Fe 500D) 6 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in old size bricks in cement mortar 1:6
M&L for Brickwork with flyash bricks, straight or curved on plan at any radius in half brick thick walls, built in 1:6 cement mortar
M&L for 10 mm thk cement plaster in C:M (1:6) finished above dado/ skirting as specified. Internal Plaster
M&L for 2mm thick wall care putty on wall above skirting all as specified.
M&L for 15 mm thk cement plaster in two layers of (10+5)mm in CM (1:4) and outer layer of 5 mm thick with water proofing compound on external surface.
M&L for integral Water Proofing Compound all as directed by EIC Note : WPC shall be measured and paid separately.
M&L for (Ceiling Plaster) 5 mm thick cement plaster in CM 1:3 on soffit of RCC slab, beams , lintel and projection as specified
M&L for Chequered tiles 300 mm x 300 mm x 25 mm thick over 15 mm thick screed bed in CM (1:4) all as specified and directed.
M&L for Vitrified tiles 600 mm x 600 mm x 10 mm thick, over 20mm bedding layer in CM (1:6) over 75mm thick PCC (1:3:6) type C-2 over 75mm thick sand cushioning over 150 micron polythene film over rammed earth all as specified and directed.
M&L for Vitrified tiles 600 mm x 600 mm x 10 mm thick over 20mm bedding layer in CM (1:4) over 25 mm thick PCC (1:2:4) type B-0 over RCC roof slab as specified for first floor.
M&L for Non-skid Ceramic tiles 7-8mm thick area of each tile exc 0.11 Sqm but n exc 0.18 Sqm over 20mm bedding layer in CM (1:6) over 25 mm thick PCC (1:2:4) type B-0 over RCC roof slab as specified
M&L for Non-Skid Ceramic tiles 7-8mm thick of size 300 mm x 300mm over 20mm bedding layer in Cm (1:4) over 75mm thick PCC (1:3:6) type C-2 over 75mm thick sand coushiing over 150 micron polyyhene film over rammed earth as specified.
M&L for Non-Skid Ceramic tiles 7-8mm thick of size 300x300mm over 20mm bedding layer in CM (1:4) over 25mm thick PCC (1:2:4) type B-0 over RCC roof slab as specified.
M&L for 75 mm thick PCC (1:4:8) type D-2, using 40mm graded aggregate all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0, using 12.5mm graded aggregate all as specified and directed.
M&L for Hardcore of guage n exc 63mm broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for Vitrified tiles as in skirting over 10 mm thick screed bed in CM (1:4) to match the floor finish/border as specified
M&L for Non Skid Ceramic tiles as in skirting over 10mm thick screed bed in CM (1:4) to match the floor finish/border as specified
M&L for Glazed ceramic tiles (glossy finished) 7-8 mm thick of size 450mm x 300mm over 10mm thick screed in CM (1:4) all as specified.
M&L for two coats of plastic emulsion paint over a coat of interior primer as specified. - Interior paint
M&L for two coats of antifungal weather coat paint over a coat of antifungal primer on external surface as specified and directed.
M&L for two coats of oil bound distemper over a coat of interior primer on ceiling surface all as specified.
M&L for two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces all as specified.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, suppling & fixing in opening complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame complete all as specified and as directed.
S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified .
S&F Aluminium handles cast type, anodised, 125mm size complete, all as specified .
S&F 100mm size stainless steel hinge all as specified.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 250 mm long.
S&F for powder coating minimum thickness 50 micron Anodised aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified
S&F for powder coating minimum thickness 50 micron Anodised aluminium door shutters sliding type, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified.
S&F for powder coating minimum thickness 50 micron Anodised aluminium window and ventilator shutters sliding type without sash bars, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified.
S&F sheet glass 5.0 mm thick, ordinary quality and glazing as in aluminium door / windows all as specified.
M&L for 12mm thick prelaminated particle board interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw as in palmet boxes.
S&F Solar control film 25 micron sicked to glass panes all as directed by Enr-in-Charge.
S&F in Harrison rails, mild steel chromium plated with fixing brackets stops, rollers etc
S&F mild steel chromium plated fancy type brackets all as directed
S&F for Aluminium extruded section Door closer hydraulically regulated, designation no 3 universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg and fixed.
S&F 140mm long Floor door stopper of aluminium alloy body and tounge, anodised, with hard drawn steel spring fixed in floor.
S&F in APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified.
M&L for (padding) rendering 20mm thick CM(1:4) with WPC on concrete surfaces complete all as specified. Note : WPC shall be measured and paid separately.
S&F for rain water PVC (SWR) pipes, single socketed, in any length , with rubber rings 110mm dia
S&F 10mm dia TMT bar for rebaring to old RCC work with with new RCC work including bonding agent (old & new concrete surfaces) all as directed by Engr-in-charge. (Length of bar and dismantling of old concrete as directed by EIC)
S&F 12 mm dia TMT bar for rebaring old RCC work with with new RCC work including bonding agent (old & new concrete surfaces) all as directed by Engr-in-charge. (Length of bar and dismantling of old concrete as directed by EIC)
S&F 16 mm dia TMT bar for rebaring old RCC work with with new RCC work including bonding agent (old & new concrete surfaces) all as directed by Engr-in-charge. (Length of bar and dismantling of old concrete as directed by EIC)
S&F in Vitreous china, bowl urinal flat back, size 465 mm x 355 mm x 265 mm white(minium) complete incl providing and fixing of plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and incl 60mm long screw, grating and union for discharge pipe all as directed.
S&F Vitreous China wash down water closet pan EWC, white(excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
S&F Plastic seat cover white for EWC, closed pattern with flat bottom and cover with CP hinging device complete all as directed.
S & F PVC valve less symphonic action type (dual flush) flushing cistern 10 liters capacity low level white with inlet ball valve, float flush pipe and handle including bracket complete all as specified and directed.
S&F PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement all as specified and directed.
S & F Vitreous china ware wash hand basin, white, flat back of size 550 mm x 400 mm including 32mm brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, etc complete all as specified and as directed.
S & F Two way Bib Taps, cast copper alloy, 15 mm dia, Chromium Plated, Fancy Type screwed down for iron pipe and fixed etc complete
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed
S & F CP Health faucet with 8mm dia, 1.2 Meter long flexible tube & wall hook all as specified & directed by Engineer-In-Charge.
S&F 32 mm bore PVC pipes as in floor / wall complete all as specified and as directed.
S&F PVC (SWR) pipes, single socketed, in any length , with rubber rings 110mm dia all as directed.
S&F 110 mm PVC (SWR) vent cowl all as specified and directed.
Supplying and Laying CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with outer dia 16 mm including taking down complete all as specified.
Supplying and Laying CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors with outer dia 20 mm including taking down complete all as specified.
S&F 75 mm dia PVC (SWR) pipe single socketed in any length with rubber ring joints, laid in trenches or fixed to wall complete as spd and directed.
S&F 75 mm dia PVC (SWR) bends any radius complete as specified and directed.
S&F 110 mm PVC(SWR) bend any radius complete all as specified and directed
S&F Stop valves 15 mm chromium plated fancy type caste copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed , as spd and directed.
S&F 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixe as spd and directed.
S&F Rotational moulded water tank 500 liter polye-thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as spd and directed by Engr in charge.
S&F PVC grating doom 100 mm dia complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm as spd and directed.
S&F Sheet glass shelf assembly consisting of 5.0mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long
S&F 15mm bore Brass CP angular stopcock fancy type complete all as specified and directed.
Demolition of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work cement concrete is reinforced (reinforcement cut as required to facilitate demolition)
S&F Framed work such as grills, gratings, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Cutting chases in concrete block walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing etc., and making good, cutting not ecx 10 cm girth
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win?dow-cills, cooking plat?forms and like in cement mortar (1:4) including point?ing in white cement (1:2) us?ing marble dust with admixture of pigment to match with shade of granite
M&L 75 mm thk PCC, type C-2, 1:3:6 (using 40 mm graded crushed stone aggregate) as in plinth protection
M&L for ATT for top surface of filled earth under floor @ of 5 litres of emulsion per square metre of surface all as directed.
M&L ATT for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area all as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and re-forming benching as required complete all as specified and as directed.
SCHEDULE 'A' PART-II (E/M PORTION) Note : Earth work required for this section shall be measured at Schedule 'A' Part-I aobe.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light point controlled by one 5/6 amps, two way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one bell point controlled by one 5/6 amps, one way bell push including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board controlled with one, oneway switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way modular switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps modular socket outlet on same board controlled with other switch complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 4 Sqmm (phase & neutral) and one run of 4 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (heavy duty) of size not less than 20 mm dia and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 15/16 amps modular socket outlet on independent board controlled with one, 15/16 amps one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
S & F modular type 6 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete all as specified and directed.
S & F modular type 6 A two-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete all as specified and directed.
S & F modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal complete all as specified and directed.
S & F modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal complete all as specified and directed.
S & F modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005 complete as specified and directed.
S & F modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293-2005 complete as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate for LED fitting
S & F modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984 complete as specified and directed.
S & F 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5 mm complete all as specified and directed.
M & L for GI strip of size 32 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed
Supply and fixing white modular cover plate with frame 1 Module complete all as specified and directed.
Supply and fixing white modular cover plate with frame 2 Module complete all as specified and directed.
Supply and fixing white modular cover plate with frame 3 Module complete all as specified and directed.
Supply and fixing white modular cover plate with frame 4 Module complete all as specified and directed.
Supply and fixing white modular cover plate with frame 6 Module complete all as specified and directed.
Supply and fixing white modular cover plate with frame 8 Module complete all as specified and directed.
Supply and fixing modular metal flush box 1/2 Module complete all as specified and directed.
Supply and fixing modular metal flush box 3 Module complete all as specified and directed.
Supply and fixing modular metal flush box 4 Module complete all as specified and directed.
Supply and fixing modular metal flush box 6 Module complete all as specified and directed.
Supply and fixing of MCB DB double door made of sheet steel phosphates powder painted with bus bar, neutral link,earth bar and din rail double door type SPN 12 way 240 V (Blank slots covered by Blanking plate)
Supply and fixing of MCB DB double door made of sheet steel phosphates powder painted with bus bar, neutral link,earth bar and din rail double door type TPN 12 way 415 V (Blank slots covered by Blanking plate)
Supply and fix circuit/sub-main wiring with PVC insulated & unsheathed two run of 6 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through in pvc concealed conduit 20 mm bore medium grade complete all as specified and as directed by the Engr-in-Charge.. Note : (i) Two runs of 6 Sqmm and one run of 4 Sqmm cable shall measured as one length.
S & F MCB SP 06 to 32 Amps `C` series, breaking capacity 10 kA complete all as specified and as directed.
S & F MCB SPN 40 Amps `C` series, breaking capacity 10 kA complete all as specified and as directed.
S & F MCB TPN 63 Amps `C` series, breaking capacity 10 kA complete all as specified and as directed.
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6.0 mm buried directly in ground (earth pit not less than 2.25 Mtr below normal ground level ) connected to galvanized earth lead strip of size 32 mm x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including 40 mm dia medium grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm dia, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type C1, 50 mm thick precast RCC (1:2:4) type B1 pit cover reinforced with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including galvanised strip of size 32 mm x 6 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a disance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No. 3 of SSR Pt-I including taking down old one , and all as directed and specified
S&F 20W (1'x4') wall/roof mounted LED batten, extruded aluminium housing provided for efficient heat dissipation, with necessary wiring, including all required accessories for light fitting with fixing arrangement.
S&F LED lamp 15 W 3 star rated with minimum 500 lumen output, B22 holder complete all as specified and as directed
M&L for non metallic rigid PVC conduit and conduit accessories 25mm dia, medium grade concealed in wall/ceiling for TV/Telephone cable all as directed.
M&L for Telephone socket RJ11 with shutter 1 moodule complete all as directed by Engineer-in-Charge.
M&L for TV coaxial socket outlet 1 module complete all as directed by Engineer-in-Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete including necessary pvc insulated flexible wire 3 core of suitable size for connecting from ceiling rose to connector etc ,all as specified and as directed
Supply, install & testing exhaust fan Metal Body 300 mm sweep heavy duty 1370 RPM complete fixed to wall with suitable size bolts, grouted to wall and connecting up including provision of cable from connector to fan with three core flexible cable of size 24/0.2mm with copper conductor from ceiling rose to exhaust fan.
S&F in repair LED Bldg security light fitting 30 Watt with all accessories, (with extra driver) attractively styled high pressure die cast housing acting as a heat sink housing epoxy powder coated in dark graphite grey colour suitable for mounting bracket of 40mm bore GI pipe light grade complete with all accessories complete all as specified and as directed.
Supply & Fixing of GI pipe bracket of 40 mm dia grade pipe bend to shape of approx length 1.5 mtr including 2 no MS clamp of flat iron size 40×6 mmcomplete with nut bolt washer all as specified and directed (Make: Jindal,Tata,Prakash)
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade, of size 4 core 25 Sqmm.
Supply and laying well burnt old size sub class 'B' bricks of size 230mm x 115mm x 75mm bricks in trenches for cable protection of U/G cables above sand cushioning complete all as specified and directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed
Supply and laying GI pipe light grade (ISI Marked) of size 40 mm for cable protection to be fixed on wall /pole /road crossing with necessary clamps complete all as directed and specified by Engr-in-Charge.Make: TATA/Jindal/Prakash Note :- Unit rate quoted is deemed to be inclusive of MS clamps along with nuts/bolts/washers etc. if required to be fixed on pole /wall.
M/s MANIK SETHI
ELECTRO COMMERCIAL CO
M/s Manas Ranjan Bera
RANA ENTERPRISES
vaishnaveedevienterprises
DS ENTERPRISES
MS VIDYANJALI
Bidder Name
RANA ENTERPRISES
DS ENTERPRISES
MS VIDYANJALI
ELECTRO COMMERCIAL CO
vaishnaveedevienterprises
bholanath bera
M/s Manas Ranjan Bera
M/s MANIK SETHI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .