Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.9 LAccepted-AOC 2ND 6 KEDIA HOUSE MA ROAD BYELANE 1 REHABARI GUWAHATI ASSAM 781008 | KAMRUP METRO | ASSAM | 781008 | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹51.6 L+₹3.1 L (6.50%)Rejected-Finance 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹53.3 L+₹4.9 L (10.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹98,400
Closing Date
29 Jun 2022, 6:55 pmClosed
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
PROVN OF SPECTATOR GALLERY AT VOLLEY BALL GROUND AND CERTAIN OTHER WORKS AT NEW CANTT ALLAHABAD AND CHHEOKI
2022_MES_518765_3
8544/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹98,400
Yes
23 Sept 2022
16 Jun 2022
1 Jul 2022
16 Jun 2022
29 Jun 2022
17 Jun 2022
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete in any type of soil all as specified and directed
Excavating in trenches, n exc 1.5 m deep and 1.5m wide in any type of soil and getting out in any type of soil
Excavating in trenches, n exc 1.5 m deep and 1.5m wide in soft / loose soil and getting out in for laying cables
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in soft loose soil complete all as specified and directed
Removing surplus excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5M above the starting point, complete all as specified and directed.
M & L PCC 1:4:8 type D-2 (40mm graded stone off) in foundation filling and mass concrete complete all as specified and directed
M & L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M & L mild steel TMT bars 08 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for stirrups, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M & L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for stirrups, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
Use & weste of form work to sides of concrete fdns, footings, bases of columns, raft and raft beams, sides and softits (if any) of fdn and plinth beams and similar work vertical or to bater
Use & waste of form work to sides of pillars, posts, struts, piers, columns and stanchions.
Use & waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, ressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. to fair finished surfaces complete all as specified and directed
Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) to fair finished surfaces complete all as specified and directed
Use & waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide to fair finished surfaces complete all as specified and directed
M&L for RCC M-25 Controlled concrete (design mix) as in foundations, including rafts, footings foundation beams; plinth beams; bases for columns etc basement slabs under reamed piles and mass concrete
M & L for RCC M-25 Controlled concrete (design mix) in columns, pillars, piers posts and struts
M & L for RCC M-25 Controlled concrete (design mix) as in beams and columns in floors, roofs landings, balconies, canopies deck slabs and in shalves and the like
M & L for RCC M-25 Controlled concrete (design mix) as in beams, cantilevers, bressummers, lintels over 1.5m span
M & L for brickwork with kiln burnt bricks built in CM (1:6) using subclass ‘B’ bricks straight or curved on plan exc 6m mean radius with old size bricks all shown on drg and as specified and directed
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cm 1:4 complete all as specified and directed
M & L for rendering 10mm thick in cm 1:3 on fair faces of brick work or concrete surfaces for fixing of dado tiles complete all as specified and directed
M&L for rendering 5mm thick on fair face of brick work or concrete surfaces in CM 1:3 finishing the surface even and smooth on soffits of slab
M&L for rendering 10mm thick on fair face of brick work or concrete surfaces in CM 1:3 finishing the surface even and smooth on roof of slab with WPC
M&L for providing hard core of broken sand stone/boulders n.exc 63mm gauge, deposited spread and levelled in layers n.exc 15cm thick watered and rammed to true surface.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone agg) as in plinth protection
M&L Sand filling under floors or in foundations including watering and consolidation
M&L for 100 mm thick cement concrete type D-2, 1:4:8 (using 40mm graded stone agg) as in sub base.
M & L for first or premium quality coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in CM 1:6
M & L for first or premium quality glazed ceramic coloured tiles in vertical surfaces 300x200x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed
Use and waste of Form work to chullah hoods, chajjas, troughs and similar items including edges surface finished even and fair.
M&L for M-25 Reinforced cement concrete (design mix) as in chajjas
S&F factory made solid panel PVC door shutter 30mm thick consisting of frame made out of MS frame shall be covered with heat moulded plain cover PVC C channel having a PVC sheet strip of 20mm with struck in side with solvant cement for styles and plain colour PVC sheet for top rail lock rail and bottom rail and either side as gap inserted for top rail and bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading sheet and jointed to gether with solvent cement in frame at site as per specification.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet re-inforced with MS sqare tube in opening as per specification and shown in drg in SSR.
S&F, ISI marked aluminium tower bolt of extruded section and fixed 150mm long size complete.
S & F Aluminium handles cast type anodised of 125mm complete
S&F 100 but hinges exruded aluminium alloy with alloy with galvanised mild stteel hinges complete
S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete
S & F 3mm thick Figured glass, pin head type and glazing with oil putty in squares n.exc 0.5sqm in each pane
M&L for mild steel work as in guard bars conforming to Fe-290 gde E 165
M & L for tubes 15mm bore medium grade galvanised with all fittings, fixed to walls and ceilings or laid in floors complete
M&L for 20 mm dia steel tube medium grade, galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete
M & L for 500 ltrs polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed
S & F ball valve assembling for 20mm dia PTMT high pressure, with epoxy coated aluminium rod and high density plastic ball secured for iron pipe and fixed (Min wt 20mm - 210 gms) complete.
S&F gun-metal, globe or gate valves 20mm size , with iron wheel head, screwed both ends for iron pipe and fixed
S&F 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed
S & F Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms/20mm-92gms)
S&F Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts, screwed for iron pipe and fixed.
S&F PVC connection 15 mm size with P.T.M.T nuts of length 450mm complete.
S&F 15 mm dia fancy type bin taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S & F stop valves, cast copper alloy, screwed both end, high pressure, with crutch or butterfly handle of 15mm bore iron pipe or for unions and fixed
S&F in replacement stop valves, cast iron, screwed down, high pressure, with crutch or butterfly handle, screwed both ends, for iron pipe or for unions of following sizes, complete all as specified and directed for:-
(a) 20mm bore
(b) 25mm bore
S & F in replacement Gun Metal Globe or gate valve of 40 mm bore with iron wheel head , screwed both ends for iron pipe or for unions of following sizes, complete all as specified and directed.
S&F in repair shower rose swivel of PTMT any colour for fixing with 15mm pipe (min weight 40 gms each)
S & F 32mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F Brass chromium plated Tubular towel rail 20mm dia D type, 60cm long between flanges
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement
S&F for vitreous China squatting pan, Orissa pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe) fixed
S & F Vitreous china bowl urinal flat back, size of 665x355x265mm white with grating and union for discharge pipe complete
Supply and fixing low level PVC flushing cistern 10 Ltrs capacity valve less, symphonic action type white with inlet ball valve, float and handle including bracket complete with PVC long bend.
S & F Vitreous china WHB white flat back, size 550x400mm excluding taps , waste, chain and plug and procelean stopper but including bracket, including cutting for and pinning in ends of brackets or errecting stands but exclusive of fixing of supply and waste pipe
S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors as specified.
S&F 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors as specified.
S&F 110mm dia PVC (SWR) junction single (single T) equal or unequal
S&F 15mm dia Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimun weight 60gms)
S&F 32/40mm dia PVC waste for WHB and Urinal
Supply only water proofing compound
M&L for preparation surfaces, plastred or unplastred on ceiling and applying three coat of white wash.
M&L for 150mm dia concrete bed to pipes in PCC (1:4:8) type D2 using 40mm graded stone aggregate, including packing under and hunching against the sides of pipes after they are laid on stope and tested for sewer pipe line complete all as specified
Supplying and laying salt glazed stoneware pipe conforming to IS 651-1972 grade 'A' in trenches and jointed in cement mortar (1:1) for 150mm internal diameter of pipes complete all as specified
M&L cement concrete type B1 1:2:4 (using 20mm crushed stone agg) as in lintels upto 1.5m clear span, eills, steps; eismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in item 4028, water troughts and the like including weathering, slightly rounded or chamfered angles and throating as directed
M&L precast cement concrete type B-1 set in CM 1:2:4 using 20mm graded crushed stone agg) as in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in CM 1:6
M&L for PCC 1:2:4 type B1 (Using 20mm crushed stone agg) as in filling of concrete in manholes.
M&L for exttra for forming fair finished drain or channel 40cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/stopped ends etc
Dismantling fencing wire mesh any type any description complete
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed.
Dismantling of floor hearth or wall tling including cement mortar bedding (but not backing), removing servicesable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkhats or frames with shutters (without talking off shutters from the frame) area exc 1.50 and n.exc 4 Sqm each and removing from site complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position complete all as specified and directed.
M&L for brickwork with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed
M & L for two coats of synthetic enamel paint over a coat of red oxide primer with paint sprayer including preparation of surfaces with scrapping machine tools/electric hand grinder with brush on new steel surface, complete all as specified and directed.
S&F 3 Track UPVC Window fabricated any size of wall thickness 1.2 mm +0.25 mm made out of extruded section plain UPVC Sections. The window Frame made out of Rigid UPVC Sections meter cut at 4 Corners & joint with plastic fusion welding with internal reinforce required. The shutter section made out of extruded Rigid UPVC with internal reinforced with provision of 5mm Glass/wiremesh as per requirement . The window shall be fixed to wall using 65 x 100 MM long MS fasterners at suitable place provided for each vertical and horizontal member etc. complete as per manufacturer's specification and direction of Engineer - In- Charge.
S&F 2 Track UPVC Window fabricated any size of wall thickness 1.2 mm +0.25 mm made out of extruded section plain UPVC Sections. The window Frame made out of Rigid UPVC Sections meter cut at 4 Corners & joint with plastic fusion welding with internal reinforce required. The shutter section made out of extruded Rigid UPVC with internal reinforced with provision of 5mm Glass/wiremesh as per requirement . The window shall be fixed to wall using 65 x 100 MM long MS fasterners at suitable place provided for each vertical and horizontal member etc. complete as per manufacturer's specification and direction of Engineer - In- Charge.
S&F Pressed steel frames size 125 x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.
M&L for 32 mm thick flush shutter,solid core construction with block board core and plywood face panels,commercial type on both sides with leaping 5mm thick teak wood beading complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 150mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
M & L for two coats of synthetic enamel paint over a coat of pink primer with paint sprayer including preparation of surfaces with scrapping machine tools/electric hand grinder with brush on new wooden surface, complete all as specified and directed.
M & L for first or premium quality non skid coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for first orpremium quality glazed ceramic coloured wall tiles in vertical surface 450X300X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified.
M & L for first or premium quality non skid joint free coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) as in skirting area of each tile exc 0.18 sqm but n exc 0.38 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 10mm thick screed bed or bedding layer in CM (1:4) complete all as specified and directed.
M&L for vitrified pavement outdoor tiles of 300mm X 300mm X 9-10mm thick coloured for floor /pavement etc and jointed in solvent and pointed in coloured cement to match the tiles including 15mm thick screed bed or bedding layer ie. cement mortar (1:6) complete all as specified and as directed.
Taking up or down 15 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
Taking up or down 20 mm bore GI steel tubing and connections on (walls, ceiling, floors, etc.) including cleaning complete all as specified and as directed
S&F 15 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F 20 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F 25 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F 40 mm bore GI steel tubing "medium grade" with all fittings and fixed to wall, floor and ceiling etc complete all as specified.
S&F in repair fancy type Pillar tap 15mm bore, cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair Brass CP grating round 100mm size including pvc waste pipe holes complete all as specified and directed.
S&F in repairs CP brass towel ring 20mm dia, fixed with screws (dia of ring 150 mm)complete all as specified and directed.
S&F in repairs CP brass tubular towel rack with lower hanger, fancy type, superior quality, fixed with screws complete all as specified and directed.
S&F in repair sheet acrlyic shelf assembly 450 mm complete all as specified and directed.
S&F in repair 5 mm thick glass corner shelf 250 mm all as specified and directed
S&F in repair CP soap dish as per sample approved complete all as specified and directed.
S&F in repair toilet paper holder as per sample kept in GE office complete all as specified and directed.
S&F in repair 15mm bore chromium plated concealed stop cock with wall flange including all accessories, fancy type, complete all as specified and directed.
S&F in repair bib taps with wall flange 15mm bore, fancy type, half turn cast copper alloy chromium plated, long body with capstan head/lever and cup, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed.
S & F in repairs vitreous China white wash down water closet pan (pedestal pattern) including fixing bolts,plastic water closet white. seat cover clossed pattern with flat bottom (white colour) and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repair plastic water closet seat white/coloured, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F for in repair vitreous china wash and basin, white, flat back, size 550 mm x 400 mm fixed on MS bracket including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, waste fitting,pipe and union complete all as specified and directed.
S&F in repair PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set all as specified and directed.
S&F in repair PVC connection 15mm bore 60cm long with brass nut at each side complete all as specified and directed.
S&F in repairs suitable for 15mm dia health faucet abs body with 08 mm dia, 01 mtr long flexible tube & wall hook complete all as specified and directed.
M&L complete removal of existing treatment of wall with scrapping machine tools/electric hand grinder with brushes and applying two coats of thinnable oil distemper white or tinted over wall care putty on wall complete all as specified and directed.
M&F for preparation of old plastered, unplastered or untreated decorated surfaces of ceiling including cornices etc and applying one coat of white wash on ceiling complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed
M & L preparation of new plaster wall surface with scrapping machine tools/electric hand grinder with brushes and applying two coats of thinnable oil distemper white or tinted over wall care putty on wall complete all as specified and directed.
M&L preparation of old decorated surface of wall and applying one coat of cement base paint complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repairs 75 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trences complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S&F in repair 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified.
S&F in repair 32 mm bore low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm white in colour fixed in repairs to walls or laid in floors including all fittings such as bend, elbow, tee etc.
S&F for rolled sections Fe-290 (Gde E- 165) as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc complete all as specified and directed.
M & L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed
M&L for 15 mm thick rendering on fair faces of brick/stone masonary or concrete surfaces in CM(1:6) finished even and fair without usnig extra cement complete all as specified and directed.
M & L for preparation of newly plastered or previously untreated surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for Rendering 15 mm thick in CM(1:4) on fair faces of brick work or concrete surfaces to be finished even and smooth without using extra cementt complete as all spfd and directed by Eic
M&L for preparing of new plastered surface of walls and applying two coats of cement base paint, over chalk whitening complete all as specified and directed.
M&L preparation of old decorated surface of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing old decorated surfaces of wall and applying two coats of white wash complete all as specified and directed.
S&F MS framed work as in doors frame,doors or gates of angle iron,door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc. to prepared for hanging or sliding with including either hooks and hinges, also fastening and fixing and similar work confirming to Fe 290 Gde-E-165 complete all as specified.
M & L for 35 mm thick IInd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed.
M&L for plain cement concrete type B2 1:2:4 (40 mm graded aggregate) in foundations, filling and mass concreteas in levelling course complete all as specified and directed.
M & L for first and premium quality non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for first or premium quality Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for 18-20mm thick Machine cut kota stone slab flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for 18-20 mm thick Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
S&F 4mm thick non asbestos fiber cement bldg board of 595mm x 595mm in size decorative finish with and including powder coated GI false ceiling grid (of ceiling suspension system) of 600mm x 600mm size and galvanized main Tee and cross Tee including wall angle grid hanging with including 4mm dia GI wire roof/ceiling fasteners or butterfly clips etc complete all as specified & as directed.
Dismantling posts or struts(wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground including removing from site complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B-2 using 40mm graded stone aggregate in foundations, filling and mass concrete all as specified & directed.
S &F Mild steel work conforming to Fe 410-0 or Fe 310-0 in posts & struts in fencing including cutting top to shape as directed, drilling holes, notching for wire, etc; flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting etc complete.
All as per item No 154 above but fabrication only
S & F joist, channel, angle, or tee sections, Fe-410-W (Gde-E-250) quality-B, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated)
Supply only chain link mild steel galvanized fencing, any type or size complete.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete.
S&F in exterior finish designer pavement tiles, coloured, superior quality, 300x300x10mm thick as in floors/ pavement etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical / horizontal plane
(d) One point for socket outlet 5 amp same board
Same as above but for One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
Same as above but for One 3 pin 15 Amp socket outlet point controlled by one switch using 4.0sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
S&F switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 amp flush type complete all as specified & directed.
S&F switch piano flush type 16 amps, 230V AC single pole one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type complete all as specified & directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified & directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified & directed.
S&F sheet metal enclosure for MCB's 240 volt 12 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 40/63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified & directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
(a) 2x4.0 sq. mm + 1x2.5 sq. mm earth wire
(b ) 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
(c) 2x10.0 sq. mm + 1x6.0 sq. mm earth wire
M&L cutting & Chasing required on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
M&L cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
(i)100mm x 100mm
(ii) 175mm x 100mm
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.as specified or directed by Engr-in- Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers as specified and directed by Engr-in-Charge.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in replacement of existing worn out ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40/42 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat pt No: PLUTONEO2X2PLR42WLED857S of make Havells 'or' RC380B LED36S-4000 G4 L60 W60 PSD OD WH OC of make Philips 'or' LCTTLRP-36-FO-CDL of make Crompton or its equivalent as approved.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L cutting & Chasing required on on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
M&L cutting & chasing required not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
Supply & fixing Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & fixing MCB with high rating MCB Triple pole, 100 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing MCB with high rating MCB Triple pole & Neutral, 63 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply, fixing, connecting & testing FTL fitting with high lumen LED batten tube light of 18 Watt having 2100 lumen output with integral/in built driver along with fixture complete all as specified and directed. Make: Philips/Havells/CG or as approved
Supply, fixing, connecting & testing sketch /bulk head light fitting of any type by energy efficient LED tube light of 10 Watt with integral/in built driver along with fixture complete all as specified and directed. Make: Philips/Havells/CG or as approved
Supply and fixing 1100 volts grade heavy duty cable PVC insulated copper conductor for submain wiring alongwith earth wire with 2x4sqmm+2.5 sqmm earth wire sizes of FRLS is pvc insulated copper conductor , single core cable insurface /recessed as required complete all as specified and directed. Note : 02 Run of wire 4 Sqmm & 01 run of 2.5 Sqmm cable shall be considered as one unit.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated copper conductor for submain wiring alongwith earth wire with 2x10sqmm+6 sqmm earth wire sizes of FRLS is pvc insulated copper conductor , single core cable insurface /recessed as required complete all as specified and directed. Note : 02 Run of 10 Sqmm and 01 Run of 6 Sqmm cable shall be considered as one unit.
Supply & fixing DB with single phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. Cat Part no - DHDPSHODPW04 of make - Havells or its equivalent model in Standard/Schneider Electric/L&T/ HPL/ Indo asian/Hager
S&F for 9.0 m long steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, conforming to IS: 2713 ( Part – I, III )-1980, including applying two coats of black bitumenous paint over the embeded portion of pole, erecting in truly vertical positon as specified and directed by engineer- in- charge. NOTES : [i] Earth work, PCC foundation and copping shall be measured and paid in separate items.
Supply and laying sub class 'B' bricks laid flat across the length of cable for protection of cable complete all as specified and directed.
M&L for sand cushioning with ganga sand underground cable (8 cm thick befor laying and 15 cm thick after laying the cable complete.
Material & labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation of size 600x600x1500 mm (planting depth) of street light poles complete all as specified and directed by Engineer-in-Charge.
Material & labour for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundation of street light poles complete all as specified and directed by Engineer-in-Charge.
S&F pole boxes three phase of size 15"x10"x5, MS Box made with 3.10 mm sheet outdoor type fix to pole with suitable MS clamps made of MS flat MS 40X6 mmthick and comprising of aluminium busbars 32 Amps 04 Nos fixed on apoxy insulator support and one MCB SP Amps C series, C series, 10 KA, 240 volts incl cable gland connection complete.
S&F for connectiong and testing LED floodlight fitting of 100 Watt, high pressure die cast aluminium housing, with minimum 105 lumen/watt system efficacy, heat resistant toughened glass, with frame IP-66 protection, better optics for uniform distribution roadway luminaires complete andconnecting the fitting electrically. Make Havells cat No- JETAIRISFLS/100W/LED 757 APWBLTG equivalent Wipro/Crompton etc.
M&L for wiring drawn inside steel pole andconnection with PVC insulated PVC sheathed flexible copper strandedcable of size 2.5 sqmm 2 core and1.5 sqmm 1 core for connection to light fitting fitted at pole form pole box drawn inside steel pole making necessary hole complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
M & L for first orpremium quality non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.18 sqm but n exc 0.38 sqm,in floor ,wall etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
MOHAMMAD RIZWAN CONTRACTOR
SAP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .