Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹19.2 L+₹10,830 (0.57%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance NOT BEING L1 BIDDER | |
| 3 | L3₹21.2 L+₹2.1 L (10.9%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-Finance NOT BEING L1 BIDDER | |
| 4 | L4₹22.1 L+₹3.0 L (15.9%)Rejected-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L4 | Rejected-Finance NOT BEING L1 BIDDER | |
| 5 | L5₹23.0 L+₹4.0 L (20.8%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 BIDDER |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
21 Jul 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
CA NO GES U 35 2023 24 REWIRING OF OTM MD ACCN, REPAIR MAINT OF BLDG EARTHING AT GOLF VIEW, SAPPER ENCLAVE AND CERTAIN MD AND OTM ACCN UNDER AGE EM, GE SOUTH UDHAMPUR
2023_MES_606767_1
GE/S(U)-35/2023-24
Open Tender
Civil Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹58,000
17 Oct 2023
30 Jun 2023
22 Jul 2023
30 Jun 2023
21 Jul 2023
14 Jul 2023
Amount
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCCB/MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in and including PVC concealed conduit as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with Modular sunken boxes & PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly as complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 4 above but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 4 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 4 but for One light point controlled by two 2-way switches,with cables 1.5 sq. mm size complete all as specified and as directed.
All as per Srl item No 4 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F for modular switch 6 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular switch 16 Amps single pole one way 230 V, 50 Hz, AC , with outer strip complete all as specified and as directed.
S&F for modular socket 3 Pin 6 Amps flush type 230 V, 50 Hz, AC , with outer/inner cover complete all as specified and as directed.
S&F for modular socket combined 2-in-1, 6 Pin 6 & 16 Amps 230 V, 50 Hz, AC , flush type with outer/inner cover complete all as specified and as directed.
S & F Modular Bell push flush type 5 amp 230 V, 50 Hz, AC, complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & caping as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with sunken boxes & PVC back plate for mounting all type switches, sockets & regulators etc with front plate including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 14 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly.
All as per srl item No 14 above but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed..
All as per srl item No 14 but for One light point controlled by two 2-way switches, with cables 1.5 sq. Mm size complete all as specified and as directed.
All as per Srl item No 14 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
S&F piano switch 5 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and as directed.
S&F piano switch 15 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and as directed.
S&F for Socket outlet 2 in 1, 3 pin, 15A, 230 V, 50 Hz, AC, complete all as specified and as directed.
S&F Switch socket combination 2-in-3 pin 5 Amps flush type complete all as specified and as directed.
M&L for Switch socket combination 2-in-1, 3 pin 5 & 15 Amps flush type complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
S & F calling Bell ding dong 230 volts single pole 50Hz complete all as specified and as directed.
S&F electronic step type fan regulator 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead all as specified. Including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in PVC concealed conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in PVC concealed conduit/casing capping 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in PVC concealed conduit/casing capping 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead including taking down old sub main wire complete all as specified and as directed.
S&F Sheet metal enclosure double door type for MCCB TPN DB upto 125 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link including MCCB 125 Amps 25 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F Sheet metal enclosure double door type for MCB TPN DB upto 6 way vertical type 415 volts with 400 Amps rated busbar and neutral link including MCB upto TPN 100 Amps 10 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F Sheet metal enclosure double door type for MCB TPN DB upto 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 8 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F Sheet metal enclosure double door type for DBs (when MCB to be used) Single pole & neutral 4 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S & F in replacement MCCB Three Pole & Neutral capacity of 125 amps 415 volts rupturing capacity 16 KA complete all as specified and as directed.
S & F in replacement MCB Single pole and neutral 240 volt any rating from 40 amps"C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB single pole and neutral 240 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 40 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 63 Amps "C" series, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement MCB TPN 415 volt any rating from 100 Amps "C" series, with rupturing capacity 10 KA, inculding providing thimble for out going cable complete all as specified and as directed.
S & F in replacement Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps including taking down of old complete all as specified and as directed.
S & F in repairs LED lights fitting 1x 5W, 230V, white/ warm white AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED lights fitting 1x 10W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED lights fitting 1x 20W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S & F in repairs LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitablesize complete all as specified and as directed.
S & F in repairs LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp,clamps,suitable bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and as directed.
S & F in repairs LED wall mounting mirror type white/ warm white pitcture light fitting with high out put diffuser 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED decorative down light fitting/recess mounted round type white/ warm white with high out put diffuser 12 watt 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED decorative surface mounted light fitting round/square type white/ warm white with high out put diffuser 18 watt 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED panel decorative down light fitting/recess mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified.
S & F in repairs LED panel decorative surface mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED wall mounting Decorative wall light fixture CITY 3 made up of Polycarbonate, suitable for 9 W retrofit LeD Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S & F in repairs LED Decorative, STYLO wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LED lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as specified and as directed.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
Supply & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 10 Sqmm x 2 core size including taking down old cable complete all as specified and as directed. Note : Earth work and other connected work shall be measured & paid sperately.
Supply & Laying in trenches or passing through pipe, 1100 volts grade heavy duty cable with "XLPE" insulated aluminium conductor standard served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of 16 Sqmm x 4 core size including taking down old cable complete all as specified and as directed. Note : Earth work and other connected work shall be measured & paid sperately.
Excavation in trenches and exceeding 1.5m wide and not exc 1.5m in depth in hard/ dense soil and getting out complete all as specified and as directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L Dry sand for sand cushioning to under ground cable 8 cms thick before laying the cable before and 15 cms thick after laying & streching the cable in trenches, including hand punning and consolidating complete all as specified and as directed. Note : for payment purpose punned thickness shall be measured
Bricks sub class 'B' brick laid dry, flat with width equal to length of brick as cover laid over the cabel to give mechanical protection to underground cabels complete all as specified and as directed.
M/S Chib Engineers
SINGH CONST CO
m/s shanti trading company
M/S BHARAT LIGHT ELECRIC.CO
PREM NATH KHAJURIA AND SONS
DEV RAJ MAGOTRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .