Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAdmitted-Finance UDHAMPUR | L1 | Admitted-Finance | |
| 2 | L2₹42.0 L+₹5.5 L (15.2%)Admitted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | L2 | Admitted-Finance | |
| 3 | L3₹45.8 L+₹9.4 L (25.7%)Admitted-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | vijay builders L3 | M/S VAISHNO TRADERS L1 | M/S SURAJ PARTAP SINGH L2 |
|---|---|---|---|---|---|---|
| 1.00Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. Long ST poles, 30mm² ACSR Conductor at WSS Paryan (Southian & Stani) Stage Intake. | ||||||
| 1.01 | 9 mtr. Long ST Pole (ST-410 SP-33) | 24 | No. | 60,000 ₹4,68,000 | 60,000 ₹4,20,000 Lowest | 72,000 ₹4,92,000 |
| 1.02 | GI V Cross -arm with top Bracket including clamps | 350 | Kg | 7,000 ₹52,500 | 3,500 ₹42,000 Lowest | 3,500 ₹56,000 |
| 1.03 | GI Channel X-arm including clamps and Angle for braces | 210 | Kg | 4,200 ₹31,500 | 2,100 ₹25,200 Lowest | 2,100 ₹33,600 |
| 1.04 | 30mm² ACSR conductor | 3.8 | Km | 30,400 ₹1,71,000 | 11,400 ₹1,25,400 Lowest | 19,000 ₹1,71,000 |
| 1.05 | PG Clamps for 30mm² ACSR conductor | 14 | No. | 700 ₹5,600 | 140 ₹420 Lowest | 700 ₹4,200 |
| 1.06 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. | 66 | No. | 3,300 ₹19,800 | 660 ₹13,200 Lowest | 1,320 ₹19,800 |
| 1.07 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting | 15 | No. | 750 ₹6,000 | 150 ₹3,000 Lowest | 750 ₹8,235 |
| 1.08 | Galvanized Nuts and Bolts | 24 | Kg | 1,200 ₹4,800 | 240 ₹2,880 Lowest | 480 ₹3,840 |
| 1.09 | Danger Plates with Clamps | 24 | No. | 1,200 ₹3,600 | 480 ₹1,680 Lowest | 720 ₹4,320 |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
21 Jul 2023, 4:00 pmClosed
Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division UdhampurJPDCL
Creation of 250 KVA 400 KVA Sub station alongwith erection of 11 KV Line on 9 mtr. Long ST poles, 30mm Sq ACSR Weasel conductor LT line on 8 mtr. Long ST pole at WSS Paryan
2023_PDD_219286_1
ED/Udh/18 of 2023-24 dt. 01-07-2023
Open Tender
Electrical Works
Turn-key
120 days
In District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Electric Division UdhampurJPDCL
₹1.1 L
22 Jul 2023
1 Jul 2023
22 Jul 2023
2 Jul 2023
21 Jul 2023
2 Jul 2023
2 Jul 2023 - 15 Jul 2023
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. Long ST poles, 30mm² ACSR Conductor at WSS Paryan (Southian & Stani) Stage Intake.
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR conductor
PG Clamps for 30mm² ACSR conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 250 KVA Sub Station at WSS Paryan (Southian & Steni) Stage Intake.
11/0.433 KV, 3-phase distribution Transformer 250 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
300mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase HT Trivector meter with CT PT Unit
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. long with 1 coat of Red oxide & 2 coat of Al. paint
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT 50mm² line on 8 mtr. Long ST poles at WSS Paryan (Southian & Stani) Stage Intake.
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
50mm² ACSR Rabbit Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
Painting of 8 mtr ST poles with one coat of Red oxide Paint
Painting of 8 mtr ST poles with two coat of Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. Long ST poles, 30mm² ACSR Conductor at WSS Paryan (Southian & Steni) Stage-Ist.
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR conductor
PG Clamps for 30mm² ACSR conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for installation of 400 KVA Sub Station at WSS Paryan (Southian & Steni) Stage-Ist.
11/0.433 KV, 3-phase distribution Transformer 400 KVA with Bimetallic Terminal Connectors Energy Level-2 Copper Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
400mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
09 mtr. Long ST pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
Transformer pad/G.I Channel bedding
11 KV Polymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 400 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase HT Trivector meter with CT PT Unit
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. long with 1 coat of Red oxide & 2 coat of Al. paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT 100mm² line on 8 mtr. Long ST poles at WSS Paryan (Southian & Steni) Stage-Ist
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
100mm² ACSR Dog Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
Painting of 8 mtr ST poles with one coat of Red oxide Paint
Painting of 8 mtr ST poles with two coat of Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
M/S SURAJ PARTAP SINGH
vijay builders
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .