Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.7 LAccepted-Finance 137 GREATER AKASH COLONY IZZATNAGAR BAREILLY UTTAR PRADESH 243122 | BAREILLY | UTTAR PRADESH | 243122 | 1 | Accepted-Finance Found in order |
Tender Value
₹7.6 L
Closing Date
31 May 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer(Elect)/DC
Ftr HQ BSF Jammu
Repair and maintenance of service connection cable of various building under FTR HQ BSF Jammu
2021_BSF_630726_1
10/EE(E)/FTR-JMU/2020-21
Open Tender
Electrical Works
Works
60 days
Ftr HQ BSF Jammu
Please refer tender documents
3 documents required · 3 mandatory
₹500
IG Ftr HQ BSF Jammu
Exempted
14 Jul 2021
22 May 2021
1 Jun 2021
22 May 2021
31 May 2021
22 May 2021
22 May 2021 - 31 May 2021
90 days
Amount
Laying of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required(detecting the existing faulty cable,removing the cable from trench and re-laying the repaired cable in the trench), but excluding sand cushioning and protective covering.
Upto 35 sq. mm
Above 95 sq. mm and upto 185 sq.mm
Above 185 Sq.mm and Upto 400 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in the existing RCC/HUME/METAL/G.I pipe as required.
Above 95 Sq.mm and Upto 185 Sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct/ in air as required.
Above 95 Sq.mm and Upto 185 Sq.mm
Laying and Fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall /surface as required.
Above 95 Sq.mm and Upto 185 Sq.mm(clamped with 25/40 x 3 mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as reqd.
3.5 x 50 Sq.mm (35 mm)
3.5 x 120 Sq.mm (45 mm)
3.5 x 300 Sq.mm (70mm)
Supplying and Making Straight through joint with Heat shrinkable Kit including Ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
3.5 x 35 Sq.mm
3.5 x 300 Sq.mm
Supplying and Fixing of light class G.I pipe of 50 mm dia (nominal) 3 mtr length along the pole for protection of underground cable as required
Supplying and laying of 3.5 x 50 sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in the existing RCC/HUME/METAL/G.I pipe as required.
Supplying and laying of 3.5 x 50 sq.mm PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct/ in air as required.
Supplying and fixing of 3.5 x 50 sq.mm PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size on wall /surface as required.
Providing, laying and fixing of 50 mm dia. G.I. pipe (Medium class) in wall/Road/floor for protection of UG cable including cutting the wall / floor/Road and making good the same as required.
Providing, laying and fixing of 80 mm dia. G.I. pipe (Medium class) in wall/Road/floor for protection of UG cable including cutting the wall / floor/Road and making good the same as required.
Providing & laying of 3½ X 50 sq. mm PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. (Make- Havells/ Gloster/ Finolex/Grandlay)
Supplying and laying of 3½ X 50 sq. mm additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.(Make- Havells/ Gloster/ Finolex/Grandlay)
Supply & Fixing of Electronic type single phase energy meter suitable for 10-60 amp,240v,50hz,AC supply,Electronic Digital type(Make -Havells,HPL)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .