| Sl No | Description | Qty | Unit | narayan construction L1 | Maqsood Ahmed L2 |
|---|---|---|---|---|---|
| 1.00 | M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed by Engineer-in-Charge. | 10 | Each | 500 ₹5,000 Lowest | 800 ₹8,000 |
| 2.00 | All as per ser item No. 01.00 here-in-before but for split type AC/Inverter type AC 1.5/2.0/3.0/4.1 Ton | 10 | Each | 500 ₹5,000 | 400 ₹4,000 Lowest |
| 3.00 | S & F in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and as directed. Make : AUE/FRAGMETER | 2 | Each | 500 ₹1,000 Lowest | 1,400 ₹2,800 |
| 4.00 | All as per Item No. 3 here–in–before, but AC (Window/Split Type). 2.0 TR Capacity | 2 | Each | 500 ₹1,000 Lowest | 1,400 ₹2,800 |
| 5.00 | M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and as directed. | 2 | Each | 500 ₹1,000 Lowest | 1,100 ₹2,200 |
| 6.00 | M&L in replacement Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and as directed. | 2 | Each | 500 ₹1,000 Lowest | 1,800 ₹3,600 |
| 7.00 | M&L in replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed. | 2 | Each | 500 ₹1,000 | 280 ₹560 Lowest |
| 8.00 | M&L in replacement Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed. | 2 | Set of two | 500 ₹1,000 | 400 ₹800 Lowest |
| 9.00 | M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed. | 5 | Each | 500 ₹2,500 | 250 ₹1,250 Lowest |
| 10.00 | M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed. | 5 | Each | 500 ₹2,500 | 350 ₹1,750 Lowest |
Tender Value
₹7.6 L
EMD Value
₹15,160
Closing Date
21 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) CIF(R)
AGE(I) CIF(R) C/O 56 APO
REPAIR/ MAINTENANCE OF INTERNAL ELETRIFICATION AND CONNECTED ITEMS FOR AOR OF HQ 6 SECT AND SUMMER/COOLING APPLIANCES AND HOT APPLIANCES OF HQ CIF (R) AND SIGNAL REGT UNDER AGE (I) CIF (R) 2nd CALL
2025_MES_706900_2
AGE(I)/R-17/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
AGE(I) CIF(R) PALMA
Class E and above and category b(i)
8 documents required · 8 mandatory
₹500
AGE(I) CIF(R)
₹15,160
Yes
26 Aug 2025
21 Jun 2025
28 Jul 2025
21 Jun 2025
21 Jul 2025
30 Jun 2025
Amount
M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed by Engineer-in-Charge.
All as per ser item No. 01.00 here-in-before but for split type AC/Inverter type AC 1.5/2.0/3.0/4.1 Ton
S & F in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and as directed. Make : AUE/FRAGMETER
All as per Item No. 3 here–in–before, but AC (Window/Split Type). 2.0 TR Capacity
M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and as directed.
M&L in replacement Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and as directed.
M&L in replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed.
M&L in replacement Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed.
M&L in replacement Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed.
M&L in replacement Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and as directed.
M&L in replacement Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and as directed.
M&L in replacement Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and as directed.
M&L Fan Motor in replacement Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0/3.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and as directed.
M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and as directed.
M&L in replacement Starting Relay of AC (Window/Split Type) 1.5 TR/2.0TR Capacity including taking out unser-viceable Starting Relay from AC complete all as specified and as directed.
M&L in replacement Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity (including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and as directed.
M&L in replacement Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and as directed.
S&F in replacement cooling coil suitable for window type room AC 1.5/2 ton including taking out unserviceable cooling coil of capacity 1.5/2 ton.as per sample.
S&F in replacement Condensing coil suitable for window type AC 1.5/2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton
S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity upto 2 ton.
S & F in replacement cooling coil suitable for split type AC including taking out unserviceable cooling coil up to capacity 2 ton.
S&F in replacement Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F in replacement outdoor unit suitable for 1.5 TR split type AC without compressor including taking out unserviceable outdoor unit complete all as specified and directed.
Suuply & Fix in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton.
All same as per ser item No. 24 here-in-before but for split/ window type AC capacity 2.0 Ton.
Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410/R32 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed. MAKE : KIRLOSKAR/EMERSION
M&L in replacement PCB with remote and sensor for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L in replacement PCB with remote including sensor for Split type AC upto 2.0 ton capacity including taking out unserviceable PCB complete all as specified and directed .
S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit all as specified and directed.
S&F in replacement gas charging pin valve complete including taking out unserviceable pin valve all as specified and directed.
Taking out window type AC complete unit from any height/ any floor and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per ser item No. 33 here-in-before but R- 410/32 for split type AC up to 2 TR capacity complete.
S&F in replacement Hermatically Sealed compressor for 300Ltrs capacity Deep freezer including bracing the sunction and discharge lines complete all specified and dircted.
S&F in replacement of casing of window type AC including company fitted condensing & cooling coil suitable for 1.5 TR capacity complete including PCB except compressor complete.
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per ser item No. 37 here-in-before but 1/2"complete all as specified and directed.
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S & F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
All as per ser item No. 41 here-in-before but size 1/2"complete all as specified and directed.
All as per ser item No. 41 here-in-before but size 3/8"complete all as specified and directed.
All as per ser item No. 41 here-in-before but size 5/8"complete all as specified and directed.
S&F in replacement High density poly ethylene pipes 20 mm dia (HDPE) of pressure rating 6 kgf/cm2 laid in wall/ceiling including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs complete all as specified and directed.
S&F in replacement of synthetic rubber foam for insulation for refrigerant copper piping of existin size 1/4" to 5/8" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
S&F in replacement metal plug top Single pole & Neutral and earth, 25 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed.
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and as directed by Engr-in-charge.
All as per item No. 54 here–in–before, but capcity 120/150 Ltrs
M&L for servicing of water cooler of any capacity (40 Ltr to 150 Ltrs) including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed. Make : Renutrol
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed. Make : ReNUTROL
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler of upto capacity 150 Ltrs by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, replacing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
M&L for painting of desert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep including metal fan blades SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing.
S&F in replacement motor capacitor 2.5/3.15/4 mfd.
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed
M&L for replacement of switch piano, flush type single pole, one way, 5 Amp 230 V AC ISI Marked complete all as specifed and directed
M&L for replacement of aluminium aloy multi wing Fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specifed and directed
Taking down Ceiling fans/exhaust fans/Wall fans, sealing cable end, dismantling blades and removing fan and blades to store and refixing the same at site after necessary repair work and painting all as specified and directed.
Note : Repair work and painting shall be carried out under relevent items.
M & L for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M & L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as directed.
Description all as per item No 77 here-in-before but for exhaust fans of size 300 mm sweep to 380 mm sweep
Description all as per item No 77 here-in-before but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
Description all as per item No 77 here-in-before but for table fan/wall mounted of 450 mm sweep
S & F in replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size (Bearing make/size SKF-6201/6202/ or equivalent make)
Description all as per item No. 81 above but for exhaust fan any of size/make-SKF 6203/6204 or equivelent make
M & L for replacement of rubber real of suitable size for ceiling fan complete all as specified and directed
M & L for replacement of gun metal bush suitable for any type/model/size of fans complete all as directed. Make: As per sample
M & L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface complete incl marking all as specified & directed.
Description all as per item No 85 above but exhaust fan/wall fans/Pedestral fans of size 300 mm to 450 mm sweep complete.
Supply and fix in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase all as specified and as directed. Make:- V-Guard.
Supply and fix in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase all as specified and as directed. Make:- V-Guard
Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position.
All as per ser item No. 89 here-in-before but capacity 50 ltrs complete all as specified and directed.
S&F in replacement of geyser assembly 6/9 holes suitable for 25/50 Ltrs geysers complete all as specified and directed. .
S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
All as per ser item No. 92 here-in-before but capacity 2KW complete all as specified and directed.
S&F in replacement of thermostate as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
Supply and fix in replacement of indicator light (Red & Green) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
S&F in replacement of water connection CP for inlet & outlet (Hot & Cold) 600 mm long as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/Fan socket or power) with complete fittings such as switch, sockets Ceiling rose pendent holders regulators etc. Removing old/UNSV material from site and making good the old disturbed surface.
Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable, 1100 Volts grade drawn through and including rigid non metallic PVC concealed conduit (medium grade) of suitable dia along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and in including modular pressed steel sunken boxes of required size with modular cover plate with frame for mounting modular switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to disturbed surface and pointing in using cement mortar 1:3 all as specified and as directed for the following.
One light/fan point controlled by one way switch by one way switch 5 Amp 240 Volt
One 3 pin 5 Amp socket out let on the same board.
One three pin socket outlet 5 Amps independent board complete
All as per item No 100 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
Material and labour for point wiring for one light/fan/exhaust fan controlled by one way switch with 1.5 Sqmm PVC insulated unsheathed two single core multi-stranded copper conductor (FRLS) cable, 1100 Volts grade drawn through and including PVC casing and capping of size 30/32 mm fixed to wall ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover or cover plate of modular complete for mounting of switches, sockets etc incl 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductor connected to common earth dolly all as directed and specified for the followings.
One light /fan point controled by one 5/6 Amp piano type switch
One 3 pin socket outlet 5 Amps on same board.
One 3 pin socket outlet 5 Amps on indpendent board
All as per item No 102 here in before but point wiring with 2.5 sqmm FR multi stranded copper conductor cable for main circuit and 2.5 sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board, complete all as specified and directed.
S&F in replacement of switch socket combination 2 in one, 3 pin , 5/6 Amps, 240 Volts flush type,complete all as specified and directed.
S&F in replacement of switch socket combination 2 in one , 3 pin, 5/6/16 Amps flush type complete all as specified and directed.
S&F in replacement of socket out let 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F in replacement of modular switch single pole one way 6 Amps 1 module complete all as specified and directed.
S&F in replacement of modular socket 6 A-2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed.
S&F in replacement of modular socket 6 A/16 amp -2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement of ceiling rose polycarbonate type three terminals complete all as specified and directed.
S&F in replacement of step type electronic fan regulator 120 watt single pole 240 Volts complete all as specified
S&F in replacement of modular fan regulator, electronic step type heavy duty modular 2 module 230 volts, 120 watt complete all as specified and as directed.
Supply and fix in replacement Lamp holder PVC case body of Bakelite with back plate suitable for batten fittings,complete all as specified and as directed.
S&F LED lamp,6500K,900lm in white colour of 9/10 Wattbase cap B-22 with poly carbonate difusser and aluminium heat sink ,complete all as specified & directed.
S&F in replecement of Ultra slim LED light to new 36W, 6500 K LED recess mounted bakelite panel 2' x 2' luminaire suitable for surface/grid ceiling for low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector including taking down old unserviceable luminaire, complete all as specified and as directed. Havells Cat part No.LHEBAEP7IW1W036 or equivalent cat part of make as specified in list of make here-in-after.
S&F in replecement of LED tube light fitting 1x20Watt batten type fitting 4 feet long aluminium extruded housing IP-20 rated rated voltage 230 volts(operating range 140 volt to 270 volts) , 50Hz system wattage 20 Watt +/-10% ,system current not less than 102 mA ,power factor more than 0.95, system lumen efficacy 100 lm /watt ,CCT 6500K CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75 sqmm 3 core all as specidfierd and directed. Make Havells Cat part No. LHEXARP7SN1W020 or equivalent cat part of make as specified in list of make here-in-after.
S & F in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size
S&F in replecement of plug top, AC 230 Volts, 5/6 Amps complete all as specified and directed.
S&F in replecement of plug top, AC 230 Volts, 16 Amps complete all as specified and directed.
S&F in replecement of PVC conduit medium grade with fittings, ISI marked, 25 mm size complete all as specified and directed.
S&F in replecement of PVC casing & capping with fittings, ISI marked, 25X16 mm size complete all as specified and directed.
S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 4 (Inches) complete all as specified and as directed.
S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 4 X 7 (Inches) complete all as specified and as directed.
S&F in replecement of PVC switch boards, closed recessed suitable for surfaces, sizes 8 X 6 (Inches) complete all as specified and as directed.
S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 6 Sq mm and one run of 6 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 6 sqmm cable and one run of 6.00 sqmm earth wire with PVC casing and caping shall be measured as one unit.
S&F in replecement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sq mm and one run of 4 Sq mm PVC insulated FRLSH copper conductor cable as earth continuity conductor drawn in and including PVC casing and caping/PVC rigid conduit 20mm dia with necessary accessories complete all as directed. Note : 2 Runs of 4 sqmm cable and one run of 4.00 sqmm earth wire with PVC rigid conduit shall be measured as one unit.
S&F in replecement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed.
S&F in replecement of Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 4 ways, complete all as specified.
All as per item no 129 above but SPN 8 ways 240 volts complete all as specified and directed.
All as per item no 129 above but SPN 12 ways 240 volts complete all as specified and directed.
S&F in replecement of MCB SP 6 to 32 Amp, 240 volts complete all as specified.
S&F in replecement of MCB SPN 32-40 Amp, 240 volts 50Hz AC supply, complete all specified.
S&F in replecement of MCCB 63 Amp,4 pole, 16KA 415 volts 50Hz, AC supply, complete all specified.
S&F in replecement of sheet metal enclosure for multi phase out going suitable for mounting 63 Amps FP MCCBs. Vertical distribution board 4 ways mounting as incommer with 200 Amp rared bus bar,IP- 42 Protection ,double door conceled/ wall mounting suitable for mounting MCBs/Isolators.all as specified and as directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 38,169.00 during AOC Note:- Tenderers shall not quote for this Schedule
Maqsood Ahmed (BID ID -3351635)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .