Loading…
Loading…
Tender Value
₹5.8 Cr
EMD Value
₹5.8 L
Closing Date
21 Mar 2026, 3:00 pmClosed
HOP(Works) NMDC Works Kirandul
NMDC Limited, Behind BIOP School, Bailadila Iron Ore Mine (BIOM), Kirandul Complex Dist- Dantewada 494 556
Miscellaneous Civil Works in CSD Premises at Kirandul Complex
2026_NMDC_830058_1
Works-Kirandul/ Misc Civil Works at CSD/1546/2025/
Open Tender
Civil Works
547 days
KIRANDUL
As per NIT Tender Document
3 documents required · 3 mandatory
₹0
₹5.8 L
21 Feb 2026
21 Feb 2026
21 Mar 2026
21 Feb 2026
21 Mar 2026
21 Feb 2026
21 Feb 2026 - 21 Mar 2026
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION / PRICE QUOTED FOR AMOUNT
1 Total Quoted Amount Schedule - A i/c GST
2 Total Quoted Amount Schedule - B i/c GST
3 Total Quoted Amount Schedule - C i/c GST
4 Total Quoted Amount Schedule - D i/c GST
5 Total Quoted Amount Schedule - E i/c GST
6 Total Quoted Amount Schedule - F i/c GST
7 Total Quoted Amount Schedule - G i/c GST
8 Total Quoted Amount Schedule - H i/c GST
9 TOTAL QUOTED AMOUNT INCLUDING GST
1. Free Issue Material: NIL
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - A CIVIL WORKS Construction of Open Shed
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum. 155
2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum. 16
3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum. 9
4 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum. 32
5 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Sqm. 345
6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Cold twisted bars Kg. 3200
7 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Cum. 124
8 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg. 16667
9 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. Sqm. 501
10 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm. 756
11 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. Kg. 222
12 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) Sqm. 194
13 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Sqm. 194
14 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Sqm. 166
SCHEDULE - A ELECTRICAL WORKS
15 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required.2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire.(For Lighting Circuit ) M 50
16 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required. 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire.(For Lighting Circuit ) M 30
17 Supplying of 3x1.5 sq. mm, XLPE, PVC insulated round steel armoured copper conductor power cable of 1.1 kV grade on surface/ existing cable tray/steel structure with 1mm thick GI/MS saddle as required. M 480
18 Supplying following 4Cx10 Sq. mm of Aluminium conductor XLPE insulated, PVC inner sheathed, Steel Round Wire Armoured, and PVC sheathed, 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required and conforming to relevant IS code and as per specification. (for Main DB to sub distribution board) M 100
19 Supplying and fixing of 25 mm size of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. M 180
20 Supplying and fixing of 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. M 60
21 Supplying and fixing a rectangular junction box of suitable size, made of sheet steel enclosure with a minimum thickness of 1 mm, 3-way type, suitable for indoor/outdoor use, IP55-rated, with screw-type lock for the front plate, matt surface finish, complete as required. EA 15
22 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, coupler plate, painting suspenders etc as required. M 150
23 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, painting suspenders etc as required. EA 15
24 Supplying, installing, testing and commissioning of 63A capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. complete as required EA 1
25 Supplying and fixing 63 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 1
26 Supplying and fixing 40 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 2
27 Supplying and fixing 40 A rating, DP, (Single phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 5
28 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole and neutral, miniature circuit breaker suitable for inductive load of single poles with neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 5
29 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole , miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 10
30 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. EA 10
31 Supplying and fixing 12 way, Double door, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) EA 4
32 Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick, including 25 mm Wide, 5 mm thick GI strip in the ground to top of the watering pipe, with all accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long, 2.5 Inches Dia with watering Funnel etc. and with charcoal/ coke and salt as required. EA 2
33 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. M 80
34 Supplying and laying 25mmx5mm GI strip at 0.5m below grund as strip earth electrode, including connection/ terminating with GI nut, bolt, spring washer etc.as required.(Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm). M 60
35 Providing and laying earth connection from earth electrode with 6 SWG Dia G.I. Wire in 15 mm Dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as require M 20
36 Supply of LED based High bay light fitting 200W Pressure die cast aluminium housing LED based high bay fitting with integrated high pressure die cast aluminium housing with aluminium reflector, corrosion proof. Outdoor Application, IP 65/66 Class Protection. Luminaire To be Provided with Mounting Bracket Suitable for wall/Tower/ Pole Mounting. The Luminaire Shall Be Suitable for Working On 230 V, AC, 50 HZ, complete driver IP 65/66 class protection, Input Voltage : 170 V to 250V AC, with all accessories. Aluminium Die-cast Corrosion Proof housing. The inbuilt driver shall have internal (3 KA) and External (7 KA) surge Protection, and over current and over load protection with Secondary lenses beam angle of 90 Degrees, Minimum 120 lux per Watt. LED COLOUR : 5700K to 6500K, LED CONFORMING TO LM 80 AND LUMEN OUTPUT TO LM 79. Warranty: Minimum 2 Years. Type Test Report Should Be Produced. Valid Bis Certificate Should Be Produced. Make: Bajaj / Philips / GE / Cramton / Havells / Surya / Wipro / Syska / Osram / Halonix EA 15
37 Installation, Testing, Commissioning of wall bracket/Celling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fittings, Complete with all accessories including connections etc as required. EA 15
38 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required EA 1
39 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. EA 1
A Total from Sl. No. (1 to 39)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - A)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt.21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - B CIVIL WORKS Renovation of Existing Cement Godown
1 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats Kg. 288
2 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet Sqm. 7000
3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum. 41
4 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum. 41
5 Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge: In cement mortar Cum. 36
6 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. Cum. 5
7 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg. 8568
8 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. Sqm. 380
9 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm. 378
10 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) Sqm. 655
11 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Sqm. 655
12 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Sqm. 345
13 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats Sqm. 310
14 Providing Laying & Fixing of Sal / Bija Wood on Floor for making Panel of 600X600 each of size 100X75 mm on existing floor finsihed with Plank of 25 mm thickness for makin tough wooden finished floor as directed by Engineer In Charge Cum 9
SCHEDULE - B ELECTRICAL WORKS
15 Wiring for light point / fan point/ exhaust fan point / call bell point with 1.5sq.mm. FRLS insulated copper conductor single core cable in Surface/ Recessed (concealed) steel conduit, with modular switch, modular plate, suitable GI box, and earthing the point with 1.5 sq.mm. FRLS insulated copper conductor single core cable etc as required. Extra Points for future use shall be terminated on suitable Ceiling Rose. Rates shall be same for short, medium and long points. P 16
16 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required.2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire.(For Lighting Circuit ) M 70
17 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required.2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire.(For Lighting Circuit ) M 50
18 Supplying of 3x 1.5 sq. mm, XLPE, PVC insulated round steel armoured copper conductor power cable of 1.1 kV grade on surface/ existing cable tray with 1mm thick GI saddle as required. M 220
19 Supplying and fixing of 25 mm size of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. M 30
20 Supplying and fixing of 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. M 80
21 Supplying and fixing a rectangular junction box of suitable size, made of sheet steel enclosure with a minimum thickness of 1 mm, 3-way type, suitable for indoor/outdoor use, IP55-rated, with screw-type lock for the front plate, matt surface finish, complete as required. EA 8
22 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, coupler plate, painting suspenders etc as required. M 110
23 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, painting suspenders etc as required. EA 10
24 Supplying and fixing 40 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 1
25 Supplying and fixing 40 A rating, DP, (Single phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 1
26 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole and neutral, miniature circuit breaker suitable for inductive load of single poles with neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 2
27 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 8
28 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. EA 15
29 Supplying and fixing 8 way (4+24) , Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) EA 1
30 Supply and fixing cable end box(Loose wire box) suitable for 8way double door TPN MCB distribution board, 415V on surface/recess, complete with testing and commissioning etc. as required. EA 1
31 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. M 30
32 Supply of Flood light 90W flood light LED Luminaire/Fitting, Outdoor application, IP 66 Protection. Luminaire to be provided with mounting bracket suitable for any structural arrangement/Tower/ pole mounting. The luminaire shall be capable of producing 120Lux for each watt. Secondary lence should be provide on the LED. The Luminaire shall be suitable for working on 230V, AC, 50HZ & Complete with driver. The inbuilt driver shall have surge and overcurrent/overload protection. LED colour white/warm white/yellow colour LED conforming to LM 80 and Lumen output to LM 79 and should also produce the certificate. Type test report shall be produced. Valid BIS certificate should be produced. Make: Bajaj,/Philips/GE/Crompton/Havells/Wipro/Halonix EA 5
33 Well glass Luminair fitting of 40-50W, Outdoor application IP 66 Luminair to be provided with mounting bracket suitable for Tower/ Pole mounting. The luminair capable for producing 120 lux for each watt. The luminair should be suitable for working on 50Hz 230V A.C complete with driver. The Inbuilt driver has inbuilt sugre and overcurrent/ overload protection.LED colour: white/warm white/yellow colour LED conforming to LM 80 and Lumen output to LM 79 and should also produce the certificate. Type test report shall be produced. Valid BIS certificate should be produced. Make: Bajaj,/Philips/GE/Crompton/Havells/Wipro/Halonix EA 12
34 Installation, Testing, Commissioning of wall bracket/Celling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fittings, Complete with all accessories including connections etc as required. EA 16
35 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required EA 2
36 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. EA 1
37 Supply of approved model exhaust fan 300 mm sweep , epoxy powder coated, double ball bearing, metal blade, louvers, brackets, rubber cushions etc, as required. Rating : 230 V, 50 Hz, Energy efficient With ISI Mark. Complete with all necessary accessories. EA 4
A Total from Sl. No. (1 to 37)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - B)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt.21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - C CIVIL WORKS Construction of New RCC Rooms
1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil Cum 90
2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum 92
3 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock Cum 7
4 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) Cum 2
5 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. Cum 9
6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Cum 17
7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Cum
8 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum
9 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 35.8575
10 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 5546
11 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Sqm 71.28
12 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts Sqm
13 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform Sqm
14 Centering and shuttering including strutting, propping etc. and removal of form for Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards Sqm 11.82
15 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 74.645
16 Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum 5
17 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ).The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. Cum 52
18 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) Cum
19 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) Sqm 60
20 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) Sqm
21 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) Sqm 231.35
22 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood Cum
23 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. Bija Wood 35 mm thick shutters sqm
24 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows. Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Bija wood Sqm
25 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm Each 6
26 Providing and fixing bright finished brass door latch with necessary screws etc. complete :300x16x5 mm Each 6
27 Providing and fixing bright finished brass handles with screws etc. complete: 125 mm Each 6
28 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm 561.22
29 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre Sqm
30 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) Sqm 231.35
SCHEDULE - C ELECTRICAL WORKS
31 Wiring for light point / fan point/phone point/ exhaust fan point / call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in Surface/ Recessed (concealed) medium class PVC conduit/ casing caping, with modular switch, modular plate, suitable GI box, and earthing the point with with 1.5 sq.mm. FRLS insulated copper conductor single core cable etc as required. Extra Points for future use shall be terminated on suitable Ceiling Rose. Rates shall be same for short, medium and long points. P 19
32 Same board wiring in Surface/ Recessed raw Supply, for 3/5 pin 5/ 6 amps Modular socket and switch outlet point mounted on modular switch, modular plate, on existing GI box with 1.5 sq. mm. FRLS / FR PVC copper multistrand conductor as required as per specification on same board along with 1.5 sq. mm. FRLS PVC cu. wire for earthing. Rate shall be same for short, medium and long points length and including of as required accessories as per approved make. EA 2
33 Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium class PVC conduit/ casing caping as reqired. 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire.(For Lighting Circuit ) M 50
34 Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium class PVC conduit/ casing caping as reqired.2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire.(For Lighting Circuit ) M 30
35 Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium class PVC conduit/ casing caping as reqired.2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire.( For Main DB Single phase Distribution) M 15
36 Supply of 3.5Cx25 Sq mm, Aluminium conductor XLPE insulated, PVC inner sheathed, Steel Round Wire Armored, and PVC sheathed, 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification. M 120
37 Laying of upto 35sqmm one number PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade of following size direct in ground including excavation, sand cushioning, Protective Covering and refiling the trench etc as required. M 50
38 Laying of upto 35sqmm one number PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade of mentioned size in the existing RCC/HUME/METAL pipe as required M 30
39 Laying and fixing of upto 35sqmm one number PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade of mentioned size on cable tray as required M 40
40 Supplying and making end termination with brass compression gland and aluminium lugs for 3.5x25 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required EA 2
41 Supplying and laying of 63mm dia (OD-63mm & ID-51mm nominal size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part II complete with fitting and cutting, jointing etc in the existing trench including clamping with suitable size, complete as reuired M 20
42 Supplying and fixing of 25 mm size of medium class PVC cable conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. For Power , telephone and ethernet cable. M 110
43 Supply and fixing of 3 Module(100mmx75mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. EA 4
44 Supply and fixing of 12 Module(200mmx150mm) modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. EA 2
45 Supplying and fixing 3pin, 5A celing rose on the existing junction box including connections etc.as required. EA 17
46 Supplying and fixing PVC batten/angel holder including connections etc.as required. EA 2
47 Supplying, installing, testing and commissioning of 63 A capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. complete as required EA 1
48 Supplying and fixing 63 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 1
49 Supplying and fixing 40 A rating, DP, (Single phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 3
50 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole , miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 4
51 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. EA 5
52 Supplying and fixing 8 way, Double door , horizontal type three poie and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) EA 2
53 Supplying and fixing 12 way, Double door, horizontal type three poie and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) EA 1
54 Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick, including 25 mm Wide, 5 mm thick GI strip in the ground to top of the watering pipe, with all accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long, 2.5 Inches Dia with watering Funnel etc. and with charcoal/ coke and salt as required. EA 2
55 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. M 20
56 Supplying and laying 25mmx5mm GI strip at 0.5m below grund as strip earth electrode, including connection/ terminating with GI nut, bolt, spring washer etc.as required.(Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm). M 40
57 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as require M 20
58 Supply of well glass luminaire fitting of 40-50W, outdoor application, IP 66 class, luminaire to be provided with mounting bracket suitable for tower / pole mounting. the luminaire shall be capable of producing 120 lux for each watt. secondary lence should be provided on the LED. the luminaire shall be suitable for working on 230 V, AC 50HZ & complete with driver. the inbuilt driver shall have surge and overcurrent / overload protection. LED colour : warm white/day light white colour LED conforming to lm 80 and lumen output to lm 79 and should also produce the certificate. type test report should be produced. valid bis certificate should be produced. make: Bajaj / Philips / GE / Crompton / Havells / Surya / Wipro / Syska / Osram / Halonix EA 12
59 Supply & installation of approved make LED tube batten 4 feet length with ISI mark, 18W/20W power with emergency inverter batten LED Tube Light, Voltage rating : 170 V to 250 V, 50 Hz., IP 22.Model/Type shall be confirmed by the Engineering In-charge. . EA 2
60 Supply and fixing of approved model exhaust fan 300 mm sweep, epoxy powder coated, double ball bearing, metal blade complete with frame bracket but without regulator. The work includes supply and fixing of louvers shutters complete in all respect with frame. EA 3
A Total from Sl. No. (1 to 60)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - C)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt.21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - D CIVIL WORKS Extention of Boundary Wall
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum. 212
2 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Cum. 170
3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum. 43
4 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum. 62
5 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum. 14
6 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Sqm. 204
7 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. Sqm. 180
8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level. Cold twisted bars Kg. 6840
9 Providing and fixing precast masonry block walling using 300 X 200 X 150mm & 300 X 100 X 150mm size made of 50% cement concrete 1:5:8 ( 1 cement: 5 coarse sand : 8 graded stone aggregate 10mm and down gauge) and 50% graded stone aggregate of 100mm and down size by volume of each block. Placing of blocks shall be done with CM 1:6 ( 1 cement : 6 coarse sand). All work upto floor five level. Cum. 96
10 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm. 820
11 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Sqm. 820
12 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg. 671
13 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. Sqm. 57
14 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m) having 50 no rounds per 6 metre length, upto 3m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) /Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) metre 128
15 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar Cum. 116
16 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. Cum. 34
17 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats Kg. 1219
A Total from Sl. No. (1 to 17)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - D)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - E CIVIL WORKS New Godown in Open Space
1 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil Cum 306
2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum 343
3 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Ordinary rock Cum 3.5
4 Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. Hard rock (blasting prohibited) Cum 3.5
5 Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.All kinds of soil Cum 210
6 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. Cum 266.8
7 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Cum
8 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ).The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. Cum 66.48
9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum
10 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 41.535
11 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg
12 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Sqm 206.8
13 Centering and shuttering including strutting, propping etc. Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 82.8
14 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers Sqm 446.64
15 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) Cum
16 Carriage of Material-Earth Cum 656
17 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 9.34
18 Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting Kg 216
19 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work Sqm
20 12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) Sqm 350.8
21 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) Sqm 350.8
22 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Sqm 485.16
23 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg
24 Providing and fixing mild steel round holding down bolts with nuts and washer plates complete Kg
25 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm 1738
26 Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) Metre 36
27 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.. (Glazing, paneling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 245
28 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.. (Glazing, paneling and dash fasteners to be paid for separately) .For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) Kg 216
29 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) sqm 12
30 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.(Area to be considered for the payment will be clear visible area of the shutter) Kg 55
SCHEDULE - E ELECTRICAL WORKS
31 Wiring for light point / fan point/ exhaust fan point / call bell point with 1.5sq.mm. FRLS insulated copper conductor single core cable in Surface/ Recessed (concealed) steel conduit, with modular switch, modular plate, suitable GI box, and earthing the point with 1.5 sq.mm. FRLS insulated copper conductor single core cable etc as required. Extra Points for future use shall be terminated on suitable Ceiling Rose. Rates shall be same for short, medium and long points. P 12
32 Same board wiring in Surface/ Recessed raw Supply, for 3/5 pin 5/ 6 amps modular socket and switch outlet point mounted on modular switch, modular plate, on existing GI box with 1.5 sq. mm. FRLS / FR PVC copper multistrand conductor as required as per specification on same board along with 1.5 sq. mm. FRLS PVC cu. wire for earthing. Rate shall be same for short, medium and long points length and including of as required accessories as per approved make. EA 1
33 Separate board Point wiring for 3/5 pin 5/6 Amps piano socket outlet point with 2X2.5 sq. mm. FRLS/FR PVC insulated multistrand copper conductor single core cable in Surface/ Recessed (concealed) medium class PVC conduit/ casing caping,with bends, coupler, with modular type switch/ socket, modular plate, suitable GI box and earthing the point with 2.5 sq.mm . FRLS/FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. The number of modules for the modular GI box shall be confirmed by the Engineering In-charge. EA 1
34 Point wiring for raw supply for 5/6 pin 15/16 Amps modular switch- socket outlet. point wiring with 2 x 4 sq. mm. FRLS multistrand copper conductor single core cable in Surface/ Recessed (concealed) medium class PVC conduit/ casing caping, with modular plate, suitable GI box and earthing the point with 4 sq.mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. EA 1
35 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required.2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire.(For Lighting Circuit ) M 150
36 Wiring for circuit /submain wiring along with earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium steel conduit/ casing caping as required.2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire.(For Lighting Circuit ) M 120
37 Supplying of 3x 1.5 sq. mm, XLPE, PVC insulated round steel armoured copper conductor power cable of 1.1 kV grade on surface/ existing cable tray with 1mm thick GI saddle as required. M 600
38 Supplying following 4Cx10 Sq. mm of Aluminium conductor XLPE insulated, PVC inner sheathed, Steel Round Wire Armoured, and PVC sheathed, 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as required and conforming to relevant IS code and as per specification. (for Main DB to sub distribution board) M 280
39 Supply of 3.5Cx95 sq.mm 1.1 KV grade Aluminium conductor XLPE insulated PVC inner sheathed, steel round wire armour and PVC outer sheathed power distribution cable conforming to relevant IS code & as per specification (for main incoming supply) M 350
40 Laying of one number PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade, above 35 sq.mm and up to 95 sq.mm size direct in ground including excavation, sand cushioning, Protective Covering and refiling the trench etc as required. M 300
41 Laying and fixing of above 35 sq.mm and up to 95 sq. mm (Clamped with 25x3mm MS flat clamp) PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade cable tray as required. M 100
42 Supplying and making end termination with brass compression gland and aluminium lugs for 3.5x95 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required EA 2
43 Supply of 3.5Cx35 Sq mm, Aluminium conductor XLPE insulated, PVC inner sheathed, Steel Round Wire Armoured, and PVC sheathed, 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification. (for main incoming supply) M 300
44 Laying of one number PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade of size up to 35 sq.mm size direct in ground including excavation, sand cushioning, Protective Covering and refiling the trench etc as required. M 100
45 Laying and fixing of up to 35 sq.mm PVC Insulated and PVC sheathed / XLPE Power cable of 1.1 KV Grade cable tray as required, clamped with suitable size of cable.(Clamped with 1mm thick saddle) M 200
46 Supplying and making end termination with brass compression gland and aluminium lugs for 3.5Cx35sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1KV grade as required EA 2
47 Supplying and fixing of 25 mm size of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. M 200
48 Supplying and fixing of 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. M 150
49 Supplying and fixing a rectangular junction box of suitable size, made of sheet steel enclosure with a minimum thickness of 1 mm, 3-way type, suitable for indoor/outdoor use, IP55-rated, with screw-type lock for the front plate, matt surface finish, complete as required. EA 50
50 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, coupler plate, painting suspenders etc as required. M 400
51 Supplying and installing of 100 mm width x 50 mm depth x 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts & nuts, painting suspenders etc as required. EA 15
52 Supplying, installing, testing and commissioning of 100 A capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. complete as required EA 1
53 Supplying and fixing 63 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 1
54 Supplying and fixing 40 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 4
55 Supplying and fixing 40 A rating, DP, (Single phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 4
56 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole and neutral, miniature circuit breaker suitable for inductive load of single poles with neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 4
57 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 16
58 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. EA 25
59 Supplying and fixing 8 way (4+24) , Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) EA 1
60 Supplying and fixing 12 way, Double door, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) EA 3
61 Supply and fixing cable end box(Loose wire box) suitable for 8way double door TPN MCB distribution board, 415V on surface/recess, complete with testing and commissioning etc. as required. EA 1
62 Earthing with GI earth plate 600 mm X 600 mm X 6 mm thick, including 25 mm Wide, 5 mm thick GI strip in the ground to top of the watering pipe, with all accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long, 2.5 Inches Dia with watering Funnel etc. and with charcoal/ coke and salt as required. EA 4
63 Supplying and laying 25mmx5mm GI strip at 0.5m below ground as strip earth electrode, including connection/ terminating with GI nut, bolt, spring washer etc.as required.(Jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50mm). M 200
64 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. M 80
65 Providing and laying earth connection from earth electrode with 6 SWG Dia G.I. Wire in 15 mm Dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as require. M 80
66 Supplying and fixing of A,B&C type fire extinguisher of 6 kgs capacity with wall mounting bracket as required conformation to IS 2878/1976 ( Push type) EA 13
67 Supplying and fixing of CO2 type fire extinguisher of 4.5 kgs capacity with wall mounting bracket as required conformation to IS 2878/1976 ( Push type) EA 8
68 Supplying installation, Testing and commissioning of astronomical timer switch of three out put(1output per phase) and suitable for 3 phase power configuration to be mounted in suitable Junction box/DB for automatic switching On & Off of street lights at sun set & rise on override facility with 12/24 hours display format with suitable battery and indication for relay status I/C programming at site complete as required. Aux. Contact rating 230 V, 5 A , 50 Hz AC. The Power rating should be of rating 32 A 3 pole power contactor, AC 3, rated voltage 415 V, 50 Hz. With 2 No. and 2 Nc Aux contacts of 5 A rating. Complete with all necessary connections, in all respects. EA 2
69 Supply of Flood light 90W flood light LED Luminaire/Fitting, Outdoor application, IP 66 Protection. Luminaire to be provided with mounting bracket suitable for any structural arrangement/Tower/ pole mounting. The luminaire shall be capable of producing 120Lux for each watt. Secondary lence should be provide on the LED. The Luminaire shall be suitable for working on 230V, AC, 50HZ & Complete with driver. The inbuilt driver shall have surge and overcurrent/overload protection. LED colour white/warm white/yellow colour LED conforming to LM 80 and Lumen output to LM 79 and should also produce the certificate. Type test report shall be produced. Valid BIS certificate should be produced. Make: Bajaj,/Philips/GE/Crompton/Havells/Wipro/Halonix EA 12
70 Well glass Luminair fitting of 40-50W, Outdoor application IP 66 Luminair to be provided with mounting bracket suitable for Tower/ Pole mounting. The luminair capable for producing 120 lux for each watt. The luminair should be suitable for working on 50Hz 230V A.C complete with driver. The Inbuilt driver has inbuilt sugre and overcurrent/ overload protection.LED colour: white/warm white/yellow colour LED conforming to LM 80 and Lumen output to LM 79 and should also produce the certificate. Type test report shall be produced. Valid BIS certificate should be produced. Make: Bajaj,/Philips/GE/Crompton/Havells/Wipro/Halonix EA 6
71 Supply of LED based High bay light fitting 200W Pressure die cast aluminium housing LED based high bay fitting with integrated high pressure die cast aluminium housing with aluminium reflector, corrosion proof. Outdoor Application, IP 65/66 Class Protection. Luminaire To be Provided with Mounting Bracket Suitable for wall/Tower/ Pole Mounting. The Luminaire Shall Be Suitable for Working On 230 V, AC, 50 HZ, complete driver IP 65/66 class protection, Input Voltage : 170 V to 250V AC, with all accessories. Aluminium Die-cast Corrosion Proof housing. The inbuilt driver shall have internal (3 KA) and External (7 KA) surge Protection, and over current and over load protection with Secondary lenses beam angle of 90 Degrees, Minimum 120 lux per Watt. LED COLOUR : 5700K to 6500K, LED CONFORMING TO LM 80 AND LUMEN OUTPUT TO LM 79. Warranty: Minimum 2 Years. Type Test Report Should Be Produced. Valid Bis Certificate Should Be Produced. Make: Bajaj / Philips / GE / Cramton / Havells / Surya / Wipro / Syska / Osram / Halonix EA 15
72 Installation, Testing, Commissioning of wall bracket/Celling fittings of all sizes and shapes containing up to two GLS/CFL/LED lamps per fittings, Complete with all accessories including connections etc as required. EA 54
73 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required EA 4
74 Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. EA 4
75 Supply and fixing of approved model exhaust fan 300 mm sweep, epoxy powder coated, double ball bearing, metal blade complete with frame bracket but without regulator. The work includes supply and fixing of louvers shutters complete in all respect with frame. EA 2
A Total from Sl. No. (1 to 75)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - E)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - F CIVIL WORKS Facelifting of CSD Office
1 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum. 27
2 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. Cum 5
3 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. Cum 10
4 Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete,including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand) Sqm 52
5 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) Cum. 27
6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) Cum. 10
7 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Sqm. 168
8 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Sqm. 356
9 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. Sqm 135
10 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below Each 9
11 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead: Of area 3 sq. metres and below Each 14
12 Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367: Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Note: Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for: (i) Sites with basic wind speed 45 m/sec as per IS 875 - Part 3. (ii) Sites with structure height more than 20m for all wind speeds. Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). Sqm 21
13 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood Cum. 0.75
14 Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of Engineer-in-charge and panelling with panels of: 12 mm thick pre-laminated particle board (decorative lamination on both sides) grade - 1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT - I, conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823 Grade 1, Type - II marked: Sqm. 23
15 Providing and fixing cup board shutters 25mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked exterior grade (Grade l Type ll) having one side decorative lamination and other side balancing lamination including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge Sqm. 28
16 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Sqm. 581
17 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats. Sqm. 295
18 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Sqm. 334
19 Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S.. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick Sqm. 100
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board.
20 Extra for any sunk or raised moldings in the plaster of Paris (Gypsum anhydrous) ceiling Sqm. 85
21 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 25 mm dia (heavy type) metre 21
22 Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm Each 20
23 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : 250x10 mm Each 20
24 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm Each 40
25 Providing and fixing bright finished brass double acting spring hinges with necessary brass screws etc. complete : 150 mm Each 80
26 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete : 150 mm Each 10
27 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. Each 1
28 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. Each 1
29 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. Each 2
30 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe, 32 mm dia Each 6
31 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Oval shape 450x350 mm (outer dimensions) Each 4
32 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore. Each 16
33 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore Each 12
34 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet, Sand cast iron S&S as per IS: 3989. Each 6
35 Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. Each 6
36 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm) with necessary accessories and screws etc. complete. Each 6
37 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. Kg. 303
38 Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. Kg. 1827
39 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm. 157
40 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: 15 mm dia. nominal bore metre 20
41 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work 25 mm dia. nominal bore metre 50
42 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 15 mm nominal bore Each 10
43 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 25 mm nominal bore Each 5
44 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Per Ltr 1000
45 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats Kg. 841
46 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet Sqm. 77
47 Providing and fixing on wall face unplasticised Rigid PVC / SWR rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. 110 mm diameter metre 3
48 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. Each 3
49 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes. Weighing not less than 60 gms. Each 3
50 Providing and fixing PTMT urinal cock of approved quality and colour. 15 mm nominal bore, 80 mm long. 42 mm high and 30 mm wide with BSP female threads weighing not less than 48 gms. Each 3
SCHEDULE - B ELECTRICAL WORKS
51 Wiring for light point / fan point/phone point/ exhaust fan point / call bell point with 1.5 sq.mm. FRLS / FR PVC insulated copper conductor single core cable in Surface/ Recessed (concealed) medium class PVC conduit/ casing caping, with modular switch, modular plate, suitable GI box, and earthing the point with with 1.5 sq.mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Extra Points for future use shall be terminated on suitable Ceiling Rose. Rates shall be same for short, medium and long points. Nos 69
52 Separate board Point wiring for Raw supply for 3 pin 5/ 6 Amps piano socket outlet point with 2X2.5 sq. mm. FRLS / FR PVC insulated multistrand copper conductor single core cable in in Surface/ Recessed (consealed) medium class PVC conduit/ casing caping, with with modular switch, modular plate, suitable GI box and earthing the point with 2.5 sq .mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. Nos 8
53 Same board wiring in Surface/ Recessed Raw Supply, for 5 pin 5/ 6 amps piano socket and Switch outlet point mounted on modular switch, modular plate, on existing GI box with 1.5 sq. mm. FRLS / FR PVC copper multistrand conductor as required as per specification on same board along with 1.5 sq. mm. FRLS PVC cu. wire for earthing. Nos 14
54 Separate Board Point wiring for raw supply for 6 pin 15/ 16 Amps modular piano combo/ switch- socket outlet. point wiring with 2 x 4 sq. mm. FRLS / FR PVC insulated multistrand copper conductor single core cable in Surface/ Recessed (consealed) medium class PVC conduit/ casing caping, with modular plate, suitable GI box and earthing the point with 4 sq.mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. Nos 6
55 Separate board Point wiring for UPS supply for 3 pin 5/ 6 Amps piano socket outlet point with 2X2.5 sq. mm. FRLS / FR PVC insulated multistrand copper conductor single core cable in in Surface/ Recessed (consealed) medium class PVC conduit/ casing caping, with with modular switch, modular plate, suitable GI box and earthing the point with 2.5 sq .mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. Nos 12
56 Air Conditioner Point wiring for 6 pin 20 Amps modular socket outlet point, with supply and fixing of 25 / 32A DP MCB, With DP MCB sheet steel enclosure, point wiring with 2 x 4 sq. mm. FRLS / FR PVC insulated multistrand copper conductor single core cable in Surface/ Recessed (consealed) medium class PVC conduit/ casing caping, with modular plate, suitable GI box and earthing the point with 4 sq.mm. FRLS / FR PVC insulated copper conductor single core cable etc as required. Rate shall be same for short, medium and long points. Nos 4
57 Wiring for circuit /submain wiring alongwith earth wire with the following sizes of FRLS / FR PVC insulated copper conductor, single core cable in Surface/ Recessed medium class PVC conduit/ casing caping as reqired.
57.1 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire.(For Lighting Circuit) Mtr 300
57.2 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire.(For Separate Board Circuit) Mtr 210
57.3 2 x 4 Sq.mm + 1 x 4 Sq.mm earth wire. (For Power Circuit) Mtr 80
57.4 2 x 6 Sq.mm + 1 x 6 Sq.mm earth wire.( For Main DB Single phase Distribution) Mtr 60
57.5 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For Mains, 3 phase distribution) Mtr 30
58 Supplying and fixing of following sizes/modules, GI box along with modular base & cover plate for modular switches in recess etc, as required.
58.1 6 Module(200x75mm) EA 9
58.2 12 Module(200x150mm) EA 5
59 Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections including modular plate etc. as required. Model/Type/quantity shall be confirmed by the Engineering In-charge.
59.1 5/6 A switch EA 34
59.2 15/16 A switch EA 5
59.3 3 pin 5/6 A socket outlet EA 34
59.4 6 pin 15/16 A socket outlet EA 9
60 Installation testing and commissioning of ceiling fan, including wiring the downrod of standard length (Up to 30 cm) with 1.5 Sq. mm. FRLS PVC insulated, copper conductor, single core cable etc as required with fixing of anchor fastener. Nos. 5
61 Supplying and fixing modular Stepped Type Fan Regulator 240 V, 50 Hz, on the existing modular plate, and GI box, complete with connections, testing and commissioning etc. as required. Nos. 3
62 Supplying and fixing 40 A rating, DP, (Single phase and neutral), 230 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Nos 4
63 Supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load Double pole, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 12
64 Supplying and fixing 10 A rating, 240/415 V, 10 kA, "C" curve, Suitable for inductive load single pole and neutral, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Nos 17
65 Supplying, installing, testing and commissioning of 63A capacity TPN tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with TPN disconnector FSU and HRC fuses, connections, earthing etc. complete as required EA 2
66 Supplying and fixing 63 A rating, four pole Three phase neutral, 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. EA 2
67 Supplying and fixing 8 way, Double Door, single pole and neutral sheet steel MCB distribution board, 240 V, on surface / recess complete with tinned copper bus bar, neutral bus nar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) Nos 3
68 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. Mtrs. 50
69 Supplying and fixing Telephone Socket RJ-11 on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Nos. 4
70 Supplying and drawing Two pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. Mtrs. 100
71 Supplying and drawing of single run of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. Mtrs. 100
72 Supplying and fixing of 25 mm size of medium class PVC cable conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. For Power , telephone and ethernet cable. Mtrs. 300
73 Supply of surface/recess mounted LED light fitting type squire / rectangular LED downlighter (300x300mm, i.e..1' x 1') 15 - 24 wattage. 200 - 250 V, AC, 50 HZ, the luminaire shall be capable of producing 120 LUX for each watt. secondary lence should be provided on the LED colour : white colour led conforming to lm 80 and lumen output to lm 79 and should also produce the certificate. type test report should be produced. valid BIS certificate should be produced. make: Bajaj / Philips / GE / Crompton / Havells / Surya / Wipro / Syska / Osram / Halonix Nos. 23
74 Supply and fixing of good quality wooden board of size 20" X 12" 1" Complete as required for fixing of ELCB / MCB DB & energy meter as required No. 3
75 Supply and fixing of Internet Point RJ - 45, Box and cover connector etc complete in all respect. Nos 20
76 Supply and fixing of wall/ cabin fan of 400 mm sweep, Copper winding, industrial type, aluminium/ metal impellers & casing, 220 V, 50 HZ, AC, with regulator, suitable Mounting Clamp for any structural arrangement, and including connection and all required accessories etc. as required. MAKE :- Bajaj / Crompton/ Almonared / Orient/ Khaitan/ Usha /Anchor EA 6
A Total from Sl. No. (1 to 76)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - F)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levies but Excluding GST AMOUNT
SCHEDULE - G CIVIL WORKS Drainage System
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum. 230
2 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of rock (blasting prohibited) cum 345
3 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum. 10
4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). Cum. 39
5 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size) Cum. 110
6 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Sqm. 58
7 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Sqm. 1224
8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Cold twisted bars Kg. 9900
9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Cum. 173
10 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Kg. 7101
A Total from Sl. No. (1 to 10)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - G)
(A Government of India Enterprise)
NMDC WORKS - KIRANDUL
BIOM Kirandul Complex
Name of Work : Miscellaneous Civil Works in CSD Premises at Kirandul Complex
Tender Enquiry No.: Works - Kirandul /Misc Civil Works CSD/1546/2025/39, Dt. 21.02.2025
MSTC Ref. No.: NMDC/Kirandul/Works/13/25-26/ET/710
Name of the Bidder
Sl. NO DESCRIPTION OF ITEM UNIT QUANTITY RATE (Rs) Inclusive of all taxes and duties, levise but Excluding GST AMOUNT
SCHEDULE - H CIVIL WORKS Platform for Used Oil Storage
1 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum. 20
2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum. 20
3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. Cum. 16
4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) Cum. 21
5 Providing and fixing precast masonry block walling using 300 X 200 X 150mm & 300 X 100 X 150mm size made of 50% cement concrete 1:5:8 ( 1 cement: 5 coarse sand : 8 graded stone aggregate 10mm and down gauge) and 50% graded stone aggregate of 100mm and down size by volume of each block. Placing of blocks shall be done with CM 1:6 ( 1 cement : 6 coarse sand). All work upto floor five level. Cum. 26
6 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) Sqm. 181
7 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). Sqm. 181
8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cum. 19
9 Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete. Cum. 32
10 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. Sqm. 14
11 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Cold twisted bars Kg. 1710
A Total from Sl. No. (1 to 11)
B Add GST @ 18%
C Total Quoted Amount including GST (Schedule - H)