GEMC-511687729293926
Awarded to FORYOUR RESQUE PRIVATE LIMITED
₹24.8 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Dewatering Pump for Flood and Sewage | Spechtenhauser Chiemsee a | - | 3 NOS | ₹8.3 L | 2,475,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹24.8 LQualified Make: Spechtenhauser
Model: Spechtenhauser Chiemsee a 002 GROUNDF FLOOR PANCHSHEEL APARTMENTS 8 1 DIAMOND HARBOUR ROAD SANTIVIHAR COLONEY | Make: Spechtenhauser
Model: Spechtenhauser Chiemsee a | ₹24.8 L | L1 | Qualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
8 Aug 2018, 10:00 amClosed
dewatering pumps Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 5 Year (s) Dewatering Pumps ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Dewatering Pump set DEWATERING PUMPS Or ENGINE MONOSET PUMPS generally incompliance to IS 11501 : 1986 (REAFFIRMED 2016) Complete unit including pump & engine duly coupled along with auto prime system
fuel tank etc shall be mounted on a two wheeled trolley for easy transportability
The trolley shall be equipped with Leaf Springs for Suspension
Support for Rear end and Towing Bar
Parking Breaks etc and The trolley must have minimum ground clearance of 300 mm
below leaf spring - 1/6 Type of pump Back Pull Out - Model Number of Pump Chiemsee A - Service/Duty Continuous - Location Outdoor - Fuel supply Fuel Pump by Gravity Feed through Tank - Starting Both Hand Start
Battery Start
Both CONSTRUCTIONAL Make of Pump Spechtenhauser - Casing Granded Cast Iron - Impeller Stainless Steel of Grade 20 Cr13 of Is 6603 Cast Iron of Grade FG200 of IS210
Stainless Steel of Grade 04 Cr13 of Is 6603
Stainless Steel of Grade 12 Cr13 of Is 6603
Stainless Steel of Grade 20 Cr13 of Is 6603 Casing and Impeller Wearing Ring If provided otherwise put NA Brass Cast Iron of Grade FG200 of IS210
Bronze of Grade LT82 of Is 318
Brass
NA Shaft Type Stainless Steel Chrome Steel
Stainless Steel Gland Packing Type Non Asbestors - Blade Material Aluminium Aluminium
Stainless Steel Sleeve Brass Brass
Bronze
Stainless steel Bracket Stainless steel Granded Cast Iron
Stainless steel
Others Suction Flange Stainless steel Granded Cast Iron
Others Net Positive Suction Head (NPSH) 5 - Volute Casing Granded Cast Iron - Gland Packing set Threaded Graphite Cotton - One number suitable size suction strainer and Non Return Value to be supplied with each pump Yes - Number of Stages 1 Dimension of Pump Set ( L x B x H )(mm) 500x395x435 - 2/6 Weight of Pump Set 53 - Minimum Submerge 0.1 - Delivery Flange Mild Steel - Material of Trolley MS fabricated - Suction and Delivery Pipe Dimensions ( mm x mm) (mm x mm) 100x100 - The engine shall be Vertical
inline
diesel engine capable of continuous operation and must be equipped with 12 volt starter and alternator
control panel
wiring harness for panel fuel pipes and suitable battery Yes - 12 V starting system complete with starter motor
charging alternator and Cutout Yes - Engine Make Spechtenhauser - Number of Cylinder 1 1
2
3
4 Engine Capacity 3.2 Power input to pump at Duty Point (Kilowatt) 3.2 - Diesel engine be closed coupled and mounted on a base plate robust Yes - Material of Base Plate on which Engine is Mounted Mild Steel - Make of Engine Control panel Others - Engine Control Panel with Following Items i Engine START switch ii Engine oil Pressure meter iii Engine Temperature meter iv Ampere Meter v Emergency Engine Stop Switch Engine oil Pressure meter Vi Engine Hour Meter Vii Fuel Indication meter Viii RPM Meter Yes - Safety controls to shutdown the engine in Yes - 3/6 the event of low lub oil pressure or high cylinder head temperature in case of air cooled engines Exhaust silencer of Residential type application Yes - Rotation: clock wise while facing the flywheel end Yes - Fuel Tank Capacity for min 24 hours continous running at full load 10 - Temperature Rise 30 - Standard set of tools consisting of set of 3 spanners
one screw driver
one standard plier and one nose plier of appropriate engine size shall be provided to the consignee along with
free of cost for each of Pump Set yes - Supply of Auto prime
horizontal
end suction
centrifugal type pumping unit capable handling floating material/soft solids like wooden pieces
muddy water
etc yes - PERFORMANCE Capacity (Rate of Flow) ( m³/hr) 150 50
100
150
200
250
300
600
900 Total Head (min) Corrsponding to Capacity and Speed (metres) 14 - Speed in RPM (rpm) 1400 - Pump Efficiency at Duty point Corrsponding to Capacity and Speed ( water delivered/Pump Input ) (%) 75 - Lub Oil Consumption (g/k Wh) : (g/k Wh) 10 - All rotating parts be dynamically balanced for longer bearing life yes - 4/6 and vibration free smooth and silent operation The pump shall be capable of developing required head at rated capacity for continuous outdoor operation External conditions like Rain
Snow and humidity should not affect pumping operation yes - The shut off head of the pump shall not less than 12% of head at rated capacity for 3 cusec and 5 cusec pumps having 10 mtrs As duly point head yes - The pump should be capable of starting without external priming and should be capable of operation with least human intervention yes - The pump must have non-overloading characteristics and the prime mover ie engine shall not get overloaded in the entire range of operation yes - CERTIFICATION ISI marked false true
false CM/L No and date - - Availability of Type Test Report for conformity IS as per IS:10
001latest/IS 1117 0latest/IS:7347latest forEngines
to IS:11501 latest and IS:9137 latest for pumps and other parameters to specification from any ILAC/NABL accredited/Central Govt LAB yes - Test cetificate No and Date - - 5/6 Name and address of the Lab - - Test report and certifications to be furnished to the buyer on demand yes - Warranty (Years) 1 1
4
5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shaileshkumar Ishwarbhai Dhodi 396215
Plot No. 51
GIDC
Fire Force Headquarters
Ringanwada
Nani Daman 3 15
419759
GEM/2018/B/59366
GeM Contract
dewatering pumps
GeM Contract
15 days
The Dadra And Nagar Haveli And Daman And Diu; Daman
PRODUCT
Awarded to FORYOUR RESQUE PRIVATE LIMITED
₹24.8 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Dewatering Pump for Flood and Sewage | Spechtenhauser Chiemsee a | - | 3 NOS | ₹8.3 L | 2,475,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| dewatering pumps Average Turn Over of Last 3 Years 25 Lakh (s) Experience with Gov. Required 5 Year (s) Dewatering Pumps ( 3 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Dewatering Pump set DEWATERING PUMPS Or ENGINE MONOSET PUMPS generally incompliance to IS 11501 : 1986 (REAFFIRMED 2016) Complete unit including pump & engine duly coupled along with auto prime system | - | - | - |
| fuel tank etc shall be mounted on a two wheeled trolley for easy transportability | - | - | - |
| The trolley shall be equipped with Leaf Springs for Suspension | - | - | - |
| Support for Rear end and Towing Bar | - | - | - |
| Parking Breaks etc and The trolley must have minimum ground clearance of 300 mm | - | - | - |
| below leaf spring - 1/6 Type of pump Back Pull Out - Model Number of Pump Chiemsee A - Service/Duty Continuous - Location Outdoor - Fuel supply Fuel Pump by Gravity Feed through Tank - Starting Both Hand Start | - | - | - |
| Battery Start | - | - | - |
| Both CONSTRUCTIONAL Make of Pump Spechtenhauser - Casing Granded Cast Iron - Impeller Stainless Steel of Grade 20 Cr13 of Is 6603 Cast Iron of Grade FG200 of IS210 | - | - | - |
| Stainless Steel of Grade 04 Cr13 of Is 6603 | - | - | - |
| Stainless Steel of Grade 12 Cr13 of Is 6603 | - | - | - |
| Stainless Steel of Grade 20 Cr13 of Is 6603 Casing and Impeller Wearing Ring If provided otherwise put NA Brass Cast Iron of Grade FG200 of IS210 | - | - | - |
| Bronze of Grade LT82 of Is 318 | - | - | - |
| Brass | - | - | - |
| NA Shaft Type Stainless Steel Chrome Steel | - | - | - |
| Stainless Steel Gland Packing Type Non Asbestors - Blade Material Aluminium Aluminium | - | - | - |
| Stainless Steel Sleeve Brass Brass | - | - | - |
| Bronze | - | - | - |
| Stainless steel Bracket Stainless steel Granded Cast Iron | - | - | - |
| Stainless steel | - | - | - |
| Others Suction Flange Stainless steel Granded Cast Iron | - | - | - |
| Others Net Positive Suction Head (NPSH) 5 - Volute Casing Granded Cast Iron - Gland Packing set Threaded Graphite Cotton - One number suitable size suction strainer and Non Return Value to be supplied with each pump Yes - Number of Stages 1 Dimension of Pump Set ( L x B x H )(mm) 500x395x435 - 2/6 Weight of Pump Set 53 - Minimum Submerge 0.1 - Delivery Flange Mild Steel - Material of Trolley MS fabricated - Suction and Delivery Pipe Dimensions ( mm x mm) (mm x mm) 100x100 - The engine shall be Vertical | - | - | - |
| inline | - | - | - |
| diesel engine capable of continuous operation and must be equipped with 12 volt starter and alternator | - | - | - |
| control panel | - | - | - |
| wiring harness for panel fuel pipes and suitable battery Yes - 12 V starting system complete with starter motor | - | - | - |
| charging alternator and Cutout Yes - Engine Make Spechtenhauser - Number of Cylinder 1 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 Engine Capacity 3.2 Power input to pump at Duty Point (Kilowatt) 3.2 - Diesel engine be closed coupled and mounted on a base plate robust Yes - Material of Base Plate on which Engine is Mounted Mild Steel - Make of Engine Control panel Others - Engine Control Panel with Following Items i Engine START switch ii Engine oil Pressure meter iii Engine Temperature meter iv Ampere Meter v Emergency Engine Stop Switch Engine oil Pressure meter Vi Engine Hour Meter Vii Fuel Indication meter Viii RPM Meter Yes - Safety controls to shutdown the engine in Yes - 3/6 the event of low lub oil pressure or high cylinder head temperature in case of air cooled engines Exhaust silencer of Residential type application Yes - Rotation: clock wise while facing the flywheel end Yes - Fuel Tank Capacity for min 24 hours continous running at full load 10 - Temperature Rise 30 - Standard set of tools consisting of set of 3 spanners | - | - | - |
| one screw driver | - | - | - |
| one standard plier and one nose plier of appropriate engine size shall be provided to the consignee along with | - | - | - |
| free of cost for each of Pump Set yes - Supply of Auto prime | - | - | - |
| horizontal | - | - | - |
| end suction | - | - | - |
| centrifugal type pumping unit capable handling floating material/soft solids like wooden pieces | - | - | - |
| muddy water | - | - | - |
| etc yes - PERFORMANCE Capacity (Rate of Flow) ( m³/hr) 150 50 | - | - | - |
| 100 | - | - | - |
| 150 | - | - | - |
| 200 | - | - | - |
| 250 | - | - | - |
| 300 | - | - | - |
| 600 | - | - | - |
| 900 Total Head (min) Corrsponding to Capacity and Speed (metres) 14 - Speed in RPM (rpm) 1400 - Pump Efficiency at Duty point Corrsponding to Capacity and Speed ( water delivered/Pump Input ) (%) 75 - Lub Oil Consumption (g/k Wh) : (g/k Wh) 10 - All rotating parts be dynamically balanced for longer bearing life yes - 4/6 and vibration free smooth and silent operation The pump shall be capable of developing required head at rated capacity for continuous outdoor operation External conditions like Rain | - | - | - |
| Snow and humidity should not affect pumping operation yes - The shut off head of the pump shall not less than 12% of head at rated capacity for 3 cusec and 5 cusec pumps having 10 mtrs As duly point head yes - The pump should be capable of starting without external priming and should be capable of operation with least human intervention yes - The pump must have non-overloading characteristics and the prime mover ie engine shall not get overloaded in the entire range of operation yes - CERTIFICATION ISI marked false true | - | - | - |
| false CM/L No and date - - Availability of Type Test Report for conformity IS as per IS:10 | - | - | - |
| 001latest/IS 1117 0latest/IS:7347latest forEngines | - | - | - |
| to IS:11501 latest and IS:9137 latest for pumps and other parameters to specification from any ILAC/NABL accredited/Central Govt LAB yes - Test cetificate No and Date - - 5/6 Name and address of the Lab - - Test report and certifications to be furnished to the buyer on demand yes - Warranty (Years) 1 1 | - | - | - |
| 4 | - | - | - |
| 5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Shaileshkumar Ishwarbhai Dhodi 396215 | - | - | - |
| Plot No. 51 | - | - | - |
| GIDC | - | - | - |
| Fire Force Headquarters | - | - | - |
| Ringanwada | - | - | - |
| Nani Daman 3 15 | - | - | - |
Exempted
4 Sept 2018
2 Aug 2018
contract_GEMC-511687729293926.pdf
GEM_CONTRACT • 0.03 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_419759.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .