| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹12.0 L+₹40,917 (3.52%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹12.2 L+₹61,730 (5.31%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹12.3 L+₹64,664 (5.56%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹12.9 L+₹1.3 L (11.0%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
11 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR/REPLACEMENT OF SECURITY LIGHTS, FLOOD LIGHTS WITH OTHER CONNECTED ITEMS AT NAGROTA STATION UNDER GE NAGROTA.
2021_MES_420418_1
GEN-75/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NAGROTA
Class E and above and category b (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹40,000
Yes
18 Mar 2021
9 Feb 2021
13 Mar 2021
9 Feb 2021
11 Mar 2021
24 Feb 2021
60 days
Amount
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable, including taking down old unserviceable street light timer,complete all as specified and directed.
Supply and fixing in replacement of 60 W LED Street Light luminaire confirming including all necessary arrangement for fixing on Pole made up of Epoxy coated pressure Die Cast aluminum housing confirming IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Street Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .Built in surge protection of 4 kv and External surge protection of 10 kv provided for additional safety.side entry mounted for 40 mm and above OD pipe bracket. The LED shall be tested with LM80-08 standard .The LEDs used in Street Light shall have CCT of ≥ 5700 K with CRI of ≥70. The LED Street Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have luminous of ≥ 90/watt and power factor more than 0.9 with THD less than 10% , including taking down old unserviceable street light timer,complete all as specified and directed.Cat Part No.ENDURAPEARLNEOSL60WLED757PASYTOPC of Havells or Equivalent of Make given in list of CA.
Supply and fixing in replacement of 45 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up of Epoxy coated pressure Die Cast aluminum housing confirming IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Street Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .Built in surge protection of 4 kv and External surge protection of 10 kv provided for additional safety.side entry mounted for 40 mm and above OD pipe bracket. The LED shall be tested with LM80-08 standard .The LEDs used in Street Light shall have CCT of ≥ 5700 K with CRI of ≥70. The LED Street Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have luminous of ≥ 90/watt and power factor more than 0.9 with THD less than 10%, including taking down old unserviceable street light timer,complete all as specified and directed.Cat Part No.ENDURAPEARLNEOSL45WLED757PASYTOPC of Havells or Equivalent of Make given in list of CA.
Supply and fixing in replacement of 120W LED Flood Light luminaire made up of Epoxy coated pressure Die Cast aluminum housing. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment. The Optical compartment shall be covered with heat resistant toughened glass for safety. LED Flood Light should be provided with non -yellowing modular secondary lens optics .The driver used is specially designed to have built-in-surge voltage,open/short ckt protections .External surge protection provided for additional safety. The LED shall be tested with LM80-08 standard .The LEDs used in Flood Light shall have CCT of 6500 K with CRI of ≥ 70. The LED Flood Light shall be of Integral type. The Input voltage range shall be 140V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Driver shall have minimum 04 KV and External surge protection of 10 kv for additional safety. The LED Flood Light shall have power factor more than 0.9 with THD less than 10%. having luminous ≥ 105/watt ,with advanced opticle system in order to provide improved lightining complete including complete electrical connection with fixing arrangenment on pole or wall, including taking down old unserviceable street light timer,complete all as specified and directed.Cat Part No.ENDURAPEARLMAGSL120WLED757PASYTGASTHO of Havells or Equivalent of Make given in list of CA.
Supply and fixing in replacement of old broken post top Lantern of capacity 15 W luminare made up of Epoxy coated pressure die cast aluminium housing . The luminare shall be complete IP66 for optical compartment suitable gor working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including complete electrical connection with fixing arrangement, complete all as specified and directed by Eng in Charge. Cat Part No.CORALMINIPT15WLED757PSYMTOPC of Havells or Equivalent of Make given in list of CA.
Dismantling and taking down carefully flood light, street light /perimeter lighting luminaries from its position of any size/wattage from over head line poles or from elevated sentry post for carrying out repair/replacement of burnt/worn out accessories and removing unserviceable items from site and depositing to MES store yard at Nagrota, including material and labour for replacement of worn out wiring in the control gear box and accessories with PVC insulated copper conductor single core cable 1.5 sqmm size, connector block, screws etc. Refixing the fitting after repair to its position compllete all as directed by Engr-in-Charge.(Note- Accessories/components required for replacement shall be measured and paid separately under relative item of Sch 'A' )
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 150 watts, complete all as specified and as directed.
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 250 watts, complete all as specified and as directed.
Supply & fixing in replacement Heavy duty copper wound ballast(choke) for HPSV/MH street light/flood light fitting of 400 watts, complete all as specified and as directed.
Supply & fixing in replacement Ignitor 220-240 volts AC suitable for 150/250/400 watts HPSV street light luminaries, complete all as specified and as directed.
Supply & fixing in replacement Capacitor 220-240 volts AC suitable for 150/250/400 watts HPSV street light luminaries, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV lamps suitable for 150 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV lamps suitable for 250 watts, complete all as specified and as directed.
Supply & fixing in replacement Lamp electric srew type HPSV lamps suitable for 400 watts, complete all as specified and as directed.
Supply & fixing in replacement Electronic ballast(choke) suitable for 2x24 Watt T-5, 230V, complete all as specified and as directed.
Supply & fixing in replacement Fluorescents tube lamps 24 W T-5 230V, complete all as specified and as directed.
Supply & fixing in replacement Lamp LED 30 W GLO watt 230 volts, complete all as specified and as directed.
Supply & fixing in replacement Lamp holders suitable for pin type, complete all as specified and as directed.
Supply & fixing in replacement Lamp holders suitable for 2x24 watts Lamps, complete all as specified and as directed.
S&F Mounting arm for installation of LED light made from 40mm bore GI pipe, Medium grade, of total length 2.5 m (to be fabricated as per approved design), to be supplied alongwith mounting clamps-02 Nos,fabricated from (65mm x 5mm) MS sheet, complete all as specifed and as directed.
Supply and fixing in replacement Junction box SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A capacity RVB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator and MCB SP 6 A 10 KA 240 V-01 Nos with fixing arangement fixed properly to pole/fixed on wall with MS clamps 25 x 5 mm and nut and bolts , complete all as specified and directed by the Engineer-In-Charge.
M&L in repairs for three run single core zero halogen flame retardant insulated cable 2.5 Sqmm with unilay copper conductor and drawn through pole from junction box to street light throuh conduit pipe properly fixed with pole through clamps ,nut bolts etc , complete all as specified and directed by Engr-in-Charge.
Cleaning, preparing and painting with one coat of aluminium paint to steel tubular pole 9m/11m long complete with cross arms, MS channels, angle iron, frame work, etc including numbering of pole with black enameled paint from stencil, complete all as specified and directed.
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 25 to 60W capacity, complete all as specified and directed by Eng in Charge.
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 72 to 100 W capacity, complete all as specified and directed by Eng in Charge.
Supply and Fixing in replacement of old burnt constant current driver suitable security light/flood light fitting of 120 to 180 W capacity, complete all as specified and directed by Eng in Charge.
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity, complete all as specified and directed by Eng in Charge.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5 core including taking down old cable, complete all as specified and directed by Engineer-in-Charge.
All as per ser No 28 but 25 Sqmm 4 core.
All as per ser No 28 but 16 Sqmm 4 core.
All as per ser No 28 but 10 Sqmm 4 core.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc n exc 10 sq m on plan and n exc 1.5 m in depth for shafts, wells, cesspits, manholes, pier holes, etc. and getting out any type of soil, complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5m wide and exceeding 1.5m but n. exceeding 3m in depth for foundation etc or for shaft, wells, cesspits, manhole, pair house etc not exceeding 10 Sqm on plan and exceeding 1.5 m but not exceeding 3m in depth and getting out in any kind/type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in any type of soil, complete all as specified and directed.
Removing surplus spoil to a distance not exceeding 50m and deposited where directed at a level not exceeding 1.50m from the starting point., all as specified.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete as per specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping, band, bed plates and similar items including weathering slightly rounded or chamferred angles and throughting, complete all as specified and directed.
Sand dry clean as cushioning to underground electric cable provided all as specified in clause 19.75 of of SSR Part-I 2009 complete all as specified.
Brick proection using sub class 'B' well burnt clay bricks of size 230 mm x 115 mm x 75 mm as a machnical protection to the power electric cable laid dry flat in the cable rench across the length of the cable complete all as specified and directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting, taking out and dismantling old damage PCC pole/struts any size and removing the same form site out side of MoD land, complete all as specified and directed by Engr-in-Charge.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as specified and directed by Engr-in-Charge.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 66160.00 during AOC Note:- Tenderers shall not quote for this Schedule
Kalsi Engineers and contractors
MAMTA ENTERPRISES
ASHOKA ENGINEERS AND BUILDERS
gurchan singh & sons.
R K BUILDERS
J S ENGINEERS
proach associates
M/S BALI AGENCIES
GURU KRIPA ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .