Tender Value
₹1.9 L
EMD Value
₹2,000
Closing Date
28 Apr 2020, 12:00 pmClosed
EE
132 KV S/S Bharua Sumerpur
WORK OF REPAIRE AND MAINTENANCE OF SPLIT AND WINDOW TYPE AIR CONDITIONER INSTALLED IN CONTROL ROOM AND KIOSK AT 220 KV AND 132 KV SUBSTATIONS UNDER ETD HAMIRPUR.
2020_UPTCL_461378_1
TS-05/ETDH/2020-21
Open Tender
Electrical Works
Lump-sum
90 days
132 KV Bharua Sumerpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹236
Yes
Executive Engineer
₹2,000
Yes
28 Apr 2020
22 Apr 2020
28 Apr 2020
22 Apr 2020
28 Apr 2020
22 Apr 2020
Amount
Details of Work.
Servicing of 02 ton split type air conditioner (Voltas and Hitachi make) 03 times in year including servicing of air conditioner by cleaning of filters and washing with air pressure and solvent etc. including all labour/T&P and material. The details of as under (1) 220 KV S/S Mahoba 07 AC (ii) 132 KV S/S Panwari.- 10 AC (iii) 132 KV S/S Sarila - 08 AC (iv) 132 KV S/S Kabrai - 04 AC (v) 132 KV S/S Hamirpur - 08 AC
Servicing of 1.50 ton window (Voltas make) type air conditioner 03 times in year including servicing of air conditioner by cleaning of filters and washing with air pressure and solvent etc. the details of as under (1) 220 KV S/S Mahoba 02 AC (ii) 132 KV S/S Mahoba.- 03 AC
Dection of leakge point in refrigerant pipe in bitween indoor and outdoor unit and attending the same by brazing and refilling ofrefrigerant gas as per requirement in 02 ton split A.C. . The details are as under. (i) 132 KV S/S Panwari - 02 Nos. (ii) 132 KV S/S Sarila - 02 Nos. (iii)132 KV S/S Hamirpur - 01 No. (iv) 220 KV S/S Mahoba - 01 No.
Repairing of PCB of A.C. including replecement of defective thermostat for auto control of temprecher. Details are as under. (i) 132 KV S/S Panwari - 03 Nos. (ii) 132 KV S/S Sarila - 02 Nos.
Repair/replacement of defective exhaust fan moter of 02 ton split A.C. outdoor unit.
Replacement of damaged compressor unit by new unit of A.C. compressor of same rating and make. The old scrap material (defective compresso unit will be retain by contractor. The details are as under. (i) 132 KV S/S Panwari - 01 Nos. (For 02 Ton Split type)
Replacement of defective capacitor of compressor unit by new one of rating - 50 Mfd, 220 Volt A.C.
Replacement of defective filter of cooling unit.
Reparing of voltage stablizer unit fieeding A.C. supply to air conditioner.The details are as under. (i) 132 KV S/S Sarila - 02 Nos. (ii) 132 KV S/S Panwari - 02 Nos.
Replacement of condenser coil for split/window A.C. The details as under (i) 132 KV S/S Sarila.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
P&H Engineering
M/S SATKAR TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .