Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAdmitted-Finance | ₹48.9 L | L1 | Admitted-Finance |
| 2 | L2₹49.0 L+₹11,399.90 (0.23%)Admitted-Finance | ₹49.0 L+₹11,399.90 (0.23%) | L2 | Admitted-Finance |
| 3 | L3₹49.9 L+₹92,495 (1.89%)Admitted-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹49.9 L+₹92,495 (1.89%) | L3 | Admitted-Finance |
| 4 | L4₹50.4 L+₹1.5 L (3.09%)Admitted-Finance | ₹50.4 L+₹1.5 L (3.09%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Barraq Enterprises L2 | Tech Infra Pvt Ltd L4 | SATISH & CO L3 | M/S ALJAN ENGINEERS AND CO L1 |
|---|---|---|---|---|---|---|---|
| 1.0011 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION | |||||||
| 2.00 | Supply,Installation,Testing and commissioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation
Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (SCADA Compatible) (1+2, set of 3) | 1 | set | 16,80,265 ₹16,80,265 | 19,80,000 ₹19,80,000 | 17,50,725 ₹17,50,725 | 16,00,000 ₹16,00,000 Lowest |
| 3.00 | Provding, Laying,Testing,commissioning of 11 kV 630 mm² 1-Core XLPE Cable (with one spare length) armoured, FRLS through HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm including cost of HDPE pipe | 240 | mtr | 1,836 ₹4,40,640 | 2,300 ₹5,52,000 | 2,095 ₹5,02,800 | 900 ₹2,16,000 Lowest |
| 4.00 | Provding, Laying,Testing,commissioning of 11kV, 3 core 300 mm² Aluminium Flat strip Armoured XLPE CableFRLS through HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm including cost of HDPE pipe | 150 | mtrs | 3,124 ₹4,68,600 | 2,900 ₹4,35,000 | 2,800 ₹4,20,000 | 1,500 ₹2,25,000 Lowest |
| 5.00 | Supply,Installation,Testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits for incoming cable | 4 | No | 3,982 ₹15,928 Lowest | 6,000 ₹24,000 | 4,500 ₹18,000 | 15,000 ₹60,000 |
| 6.00 | Supply,Installation,Testing and commissioning of 11 kV Outdoor Heat Shrinkable Cable Termination Kits for incoming cable | 4 | No | 3,982 ₹15,928 Lowest | 6,000 ₹24,000 | 5,000 ₹20,000 | 15,000 ₹60,000 |
| 7.00 | Supply,Installation,Testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits for outgoing cable | 3 | Set | 3,982 ₹11,946 Lowest | 6,000 ₹18,000 | 5,000 ₹15,000 | 15,000 ₹45,000 |
| 8.00 | Supply,Installation,Testing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits for outgoing cable | 3 | set | 3,982 ₹11,946 Lowest | 6,000 ₹18,000 | 5,500 ₹16,500 | 15,000 ₹45,000 |
| 9.00 | Supply,Installation,Testing and commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type 1no per phase (Set of 3 Nos) | 6 | Set | 4,977 ₹29,862 Lowest | 6,000 ₹36,000 | 5,000 ₹30,000 | 15,000 ₹90,000 |
| 10.00 | Provding, Laying,Testing,commissioning of 120 mm² XLPE LT Cable Single Core | 15 | mtrs | 284 ₹4,260 Lowest | 950 ₹14,250 | 450 ₹6,750 | 1,500 ₹22,500 |
Tender Value
₹57.1 L
EMD Value
₹1.1 L
Closing Date
22 Jul 2026, 4:30 pmClosed
Executive Engineer, STD-II, Rajbagh,Srinagar
Office of the Executive Engineer, STD-II, Rajbagh
Augmentation of 33 11KV 1X10 MVA Receiving station JVC to 2x10 MVA Electrical part
2026_PDD_312871_2
eNIT No STD-II / 37 of 2026-27 Dated 18-06-2026
Open Tender
Electrical Works
Turn-key
Srinagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer, STD-II, Rajbagh,Srinagar
₹1.1 L
30 Jul 2026
15 Jul 2026
23 Jul 2026
15 Jul 2026
22 Jul 2026
15 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | 11 kV INDOOR SWITCHGEAR OF 33/11 kV SUBSTATION | - | - | - | - |
| 2 | Supply,Installation,Testing and commissioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation
Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (SCADA Compatible) (1+2, set of 3) | 1 | set | - | - |
| 3 | Provding, Laying,Testing,commissioning of 11 kV 630 mm² 1-Core XLPE Cable (with one spare length) armoured, FRLS through HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm including cost of HDPE pipe | 240 | mtr | - | - |
| 4 | Provding, Laying,Testing,commissioning of 11kV, 3 core 300 mm² Aluminium Flat strip Armoured XLPE CableFRLS through HDPE Pipe Outer Dia 160 mm Inner Dia 148 mm including cost of HDPE pipe | 150 | mtrs | - | - |
| 5 | Supply,Installation,Testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits for incoming cable | 4 | No | - | - |
| 6 | Supply,Installation,Testing and commissioning of 11 kV Outdoor Heat Shrinkable Cable Termination Kits for incoming cable | 4 | No | - | - |
| 7 | Supply,Installation,Testing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits for outgoing cable | 3 | Set | - | - |
| 8 | Supply,Installation,Testing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits for outgoing cable | 3 | set | - | - |
| 9 | Supply,Installation,Testing and commissioning of 11 kV Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type 1no per phase (Set of 3 Nos) | 6 | Set | - | - |
| 10 | Provding, Laying,Testing,commissioning of 120 mm² XLPE LT Cable Single Core | 15 | mtrs | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.48 MB
Tendernotice_2.pdf
PDF • 1.59 MB
BOQ_1029715.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .