Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC 0 3 SHASTRI STREET FEROZEPUR CITY PB PIN 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹79.0 L+₹5.6 L (7.66%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹81.5 L+₹8.1 L (11.0%)Rejected-Finance | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹81.7 L+₹8.3 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Higher Bidder |
| Sl No | Description | Qty | Unit | Vee Vee Enterprises L2 | M/S Pee Kay Builders L3 | M/S CHAWLA CONSTRUCTION COMPANY L4 | Marwaha Builders L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed. | 1 | Cum | 800 ₹800 Lowest | 825 ₹825 | 860 ₹860 | 800 ₹800 Lowest |
| 2.00 | Demolition of cement concrete of Sunken portion of any description and in any position not otherwise specially provided for complete all as specified and directed. | 1 | Cum | 1,000 ₹1,000 Lowest | 1,217 ₹1,217 | 1,240 ₹1,240 | 1,200 ₹1,200 |
| 3.00 | Demolition of concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed. | 4.88 | Cum | 800 ₹3,904 Lowest | 1,066 ₹5,202.08 | 1,003 ₹4,894.64 | 800 ₹3,904 Lowest |
| 4.00 | Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) (in Man holes) of any description and in any position not otherwise specifically provided for complete all as specified and directed. | 0.5 | Cum | 1,500 ₹750 Lowest | 1,533 ₹766.5 | 1,582 ₹791 | 1,500 ₹750 Lowest |
| 5.00 | Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed. | 1,756 | Sqm | 50 ₹87,800 | 58 ₹1,01,848 | 59 ₹1,03,604 | 35 ₹61,460 Lowest |
| 6.00 | Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. | 42.65 | Cum | 500 ₹21,325 | 930 ₹39,664.5 | 884 ₹37,702.6 | 400 ₹17,060 Lowest |
| 7.00 | Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed. | 10 | Ten Sqm | 500 ₹5,000 Lowest | 514 ₹5,140 | 531 ₹5,310 | 500 ₹5,000 Lowest |
| 8.00 | Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. | 320 | RM | 20 ₹6,400 | 21 ₹6,720 | 20 ₹6,400 | 15 ₹4,800 Lowest |
| 9.00 | Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed. | 140 | RM | 20 ₹2,800 Lowest | 20 ₹2,800 Lowest | 21 ₹2,940 | 20 ₹2,800 Lowest |
| 10.00 | Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed. | 1 | Quintal | 250 ₹250 Lowest | 254 ₹254 | 258 ₹258 | 250 ₹250 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
3 Sept 2025, 6:00 pmClosed
CWE FEROZEPUR CANTT
HQ CWE FEROZEPUR CANTT PIN 152001
SPECIAL REPAIR TO BLDG NO P 90 AT MADRAS REGT AND NP 53 (01 TO 06) AT FWC UNDER GE (WEST) FEROZEPUR CANTT
2025_MES_722491_1
CWE/FZR-24/2025-26
Open Tender
Civil Works
Item Rate
180 days
FEROZEPUR CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (WEST) FEROZEPUR CANTT
₹1.4 L
Yes
8 Oct 2025
25 Jul 2025
10 Sept 2025
25 Jul 2025
3 Sept 2025
15 Aug 2025
Amount
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
Demolition of cement concrete of Sunken portion of any description and in any position not otherwise specially provided for complete all as specified and directed.
Demolition of concrete in ground floors and pavings not exceeding 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) (in Man holes) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall/stone tiling including cement mortar bedding (but not backing), removing broken tiles and rubbish off the premises from site complete all as specified and directed.
Demolition of brick work built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed.
Taking up or down existing 15mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed.
Taking up or down existing 20mm bore steel water tubing and connections,including clreaning for refixing or removal, fixed/laid in any situation, complete all as specified and directed.
Dismantling structural steel work in cluding doors, gates but excluding framed truss etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition and breaking of drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia 150 mm taking out of trenches and taking down from walls, if required complete all as specified and directed.
Dismantling brick tiles or terracing tiles, single layer on roofs jointed and pointed in cement mortar including removal of grass vegitation including roots near out let of RWP and OHT staging area or specifically ordered in writing complete all as specified and directed.
Demolition of mud phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part hereof ) complete all as specified. Note :- Demolition of Mud puska to be cut in average thickness from top surface of roof for creating the slope as directed
Dismantling asbestos cement/fibre (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed. Hacking out old broken glass (any size, thickness, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.
Taking down cement plaster of any description on brick walls or concrete or stone and ceilings including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size not exceeding 1.5 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) of size exceeding 1.5 Sqm but not exceeding 4 Sqm each including cutting holes in brick walls of appropriate size for insertion of cement concrete blocks for hold fasts, and removing from site complete all as specified and directed.
Taking down dhutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each and removing from site complete all as specified and directed.
Resecuring or easinfg and adjusting without taking down dhutters of any description exceeding 1.00Sqm but not exceeding 2.00Sqm each complete all as specified and directed.
Cutting into existing manhole for connecting new drain, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in PCC (1:2:4) type B-1, smooth finished and reforming benching as required for internal pipe of dia 150 mm complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil, each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
Excavating in trenches, in soft/loose soil, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cables and pipes etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out complete aii as specified and as direcetd.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceding 25cm in soft/loose soil complete all as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Surface excavation in soft/ loose soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed.
M&L for Lean Cement Concrete (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for Lean Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for Lean Cement Concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete and filling in Sunken portion complete all as specified and directed.
M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in foundations, filling and mass concrete and filling back sides of pressed steel frames complete all as specified and directed.
M&L for Lean Cement Concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.as in manhole pipe line portion only complete all as specified and directed.
M&L for brick work built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for brick work (EXCEPT BRICKS) built in cement mortar (1:6) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after demolition of brock work.
M&L for brick work in half brick thick wall built in cement mortar (1:4) with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius complete all as specified and directed.
M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate in Cover fillet minimum radius of 75mm as in roof and parapet wall junction, roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, sloping on roof including form work complete all as specified and directed.
M&L for Cast-in-Situ Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in bed blocks for hold fasts roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including form work complete all as specified and directed.
S&F factory made pressed steel frames made out of 1.25mm CRCA sheet frame of profile 125mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock plate, etc., including one shop coat of priming and 10mm dia round mild steel bar in threshold complete all as specified and directed.
S&F factory made pressed steel frames made out of 1.25mm CRCA sheet frame of profile 105mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock plate, etc., including one shop coat of priming and 10mm dia round mild steel bar in threshold complete all as specified and directed.
S&F factory made pressed steel frames made out of 1.25mm CRCA sheet frame of profile 75mm x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock plate, etc., including one shop coat of priming and 10mm dia round mild steel bar in threshold complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood (Hollock), plain framed, paneled shutters, any number of panels, panels shall be of 12mm thick BWR glade veneered particle board medium density, wood particle board with commercial face veneers, size of members as specified in clause 8.24 (a) of MES Schedule Part-I section-8 complete all as specified and directed.
S&F 35 mm thick factory made 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified and directed.
S&F in replacement Factory Made Box Type Steel Windows with glazing bars made of ERW tube hollow "P" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung skelton & glazed shutters, frame of ERW tube "P" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Glass panes and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
S&F in replacement Factory Made Box Type Steel Windows without glazing bars made of ERW tube hollow "P" section of size 60mmX25mm double rebated outer frame comprising double shutters side hung i.e. guaged shutters, frame of ERW tube "P" section size 50mmX20mm with two openable leaf for each shutter consisting two Nos sash bar of T-section 20mmX3mm welded to frame with one vertical mullion of ERW box type T-section of size 60mmX25mm and mild steel flat iron 2mm thick welded/ screwed to frame for fixing of wire gauge to frame/ shutters as given below and all as shown on Drawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed :- (i) Hold fast,150mm long of flat iron 12mmX3mm- 04Nos per window (ii) Handle of Z section 20mmX25mm,100mm long-01Nos per leaf (iii) MS Tower bolt 150mm long-02 Nos per leaf (iv) Z section 20mmX25mm,100mm long stopper -01 Nos per leaf (v) Cleat 55mm long of hollow square 15mmX12mm -02 Nos per leaf (vi) MS pintol hinges size 75mmx12mm- 2 Nos. per leaf (vii) Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). (viii) Preparation of steel surfaces of windows and grills and guard bars and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. Note: Wire cloth and grills & guard bars shall be measured and paid for separately .Area shall be measured flat for one side only for the purpose of measurement and payment .
S&F in replacement Factory Made Box Type Steel Ventilators side / top hung with glazing bars or dovetailed or welded made of ERW tube "P"-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and mild steel flat iron 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as Stopper, Cleat, Pintal hinges, holdfast etc all as shown onDrawing No. CEJZ/TD-1019/08 and CEJZ/TD-1020/08 Sheet No. 1/3 to 3/3 including taking down of old existing window complete all as specified and directed:- Note : 1. Grills and guard bars, Sheet glass and wiremesh shall be measured and paid separately. 2. Making good dismantled portion in PCC 1:2:4 type B-1 for hold fasts (four Nos for each window). 3. Preparation of steel surfaces of ventlators and applying one one shop coat of zinc chromate primer and two coats of synthetic enamel paint after installtion at site. 4. Area shall be measured flat for one side only for the purpose of measurement and payment .
S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F 50mmx47mm size solid PVC door frame made out of 5mm plain colour PVC sheet reinforced with MS square tube, complete all as specified shown on drawing and specified and directed.
S&F factory made 30mm thick (style) solid panel PVC door shutter consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified shown on drawing and specified and directed.
S&F in repairs 18-20mm thick Medium density fibre board interior grade solid construction type, fixed in repairs in Kitchen cabinets/ CBs doors shutters/ shelves ( horizontal or vertical of any type) on timber frame work /GI Flats orners with screws /nails complete all as specified and directed.
S&F 0.90mm thick Decorative laminate type -1, both sides of boards surface finish, (colour and pattern as approved) fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
S&F 125mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed.
S&F 100mm size mild steel butt hinges medium weight rolled cold complete all as specified and directed.
S&F 75mm size butt hinges of extruded aluminium alloy with galvanised steel hing pins, anodised and type C-21 complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed.
S&F 200mm long aluminium anodised barrel tower bolts of extruded section and fixed with steel screws complete all as specified and directed.
S&F 200mm long mild steel barrel tower bolts, stove enameled black, with bright bolt fixed with steel screws complete all as specified and directed.
S&F 150mm size aluminium door handle, cast type, anodised complete all as specified and directed.
S&F 75mm size aluminium door handle, cast type, anodised complete all as specified and directed.
S&F 150mm size mild steel pressed handle, oval type, stove enameled black complete all as specified and directed.
S&F stainless steel continous (piano) hinges of mild steel bright finish or electro galvanised with flap (when open) 30mm, fixed with steel screw complete all as specified and directed.
S&F 300mm long mild steel sliding door bolt, plate type, stove enameled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, with 150mm overall length of cover plate fixed in floor complete all as specified and directed,
S&F 300mm size mild steel helical door spring ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and directed,
S&F 100mm size hasp and staple aluminium anodised including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F in repairs 20mm dia mild steel curtain rods, mild steel, epoxy powder cpated with and including finials, bulvs and brackets etc. complete all as specified and directed
S&F Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S&F 3.0mm thick, plain sheet glass, ordinary quality and glazing, with oil putty or with wooden beads (supplied alongwith shutters), in squares n.exc 0.50 Sqm in each pane complete all as specified and directed.
S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete and similar work complete all as specified and directed.
S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.tes complete all as specified and directed.
S&F 10mm dia and over mild steel TMT bars , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1, using 20 mm graded crushed stone aggregate as in manhole slabs, and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work etc complete all as specified and directed. (Note : Reinforcement shall be measured and paid for separately )
M&L for 50mm thick Plain Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and expansion joints filled with bitumen mixed with sand in ratio (1:1) complete all as specified and directed.
M&L for Plain Cement Concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in filling in sunken portion complete all as specified and directed.
M&L for 75mm thick Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring,surface finished rough to receive floor topping, surface finished even and fair complete all as specified and directed.
Supply only 3mm thick and 38mm wide glass dividing strips as in floors complete all as specified. (fixing included in item of floor topping) complete all as specified and directed.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete over and including 10mm thick cement plaster in back coat in cement mortar (1:4) complete all as specified and directed.
M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Tiles coloured, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, premium quality, area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm, in vertical surfaces such as skirtings, dados, risers and steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 10mm thick rendering cement plaster in cement mortar (1:4) complete all as specified and directed.
M&L for 7 to 8 mm thick (square/ rectangular) Non-skid Ceramic Coloured Tiles, premium quality, area of each tile exceeding 0.18Sqm but not exceeding 0.36Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) complete all as specified and directed.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paverblocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete complete all as specified and directed.
M&L for 10mm thick rendering cement plaster in cement mortar (1:6) on fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering cement plaster in cement mortar (1:4) on other than fair faces of brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer on fair furfaces of brick or concrete work on roof terrace for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for 10mm thick rendering cement plaster in cement mortar (1:4) in screed bed or bedding layer for laying Water Proofing Memeberane surfaces, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for 10mm thick rendering cement plaster in cement mortar (1:3) in screed bed or bedding layer or cement plater to the sunken portion, mixed with water proofing complound as per manufacturer's instructionsfinished even and fair without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
M&L for 5mm thick rendering cement plaster in cement mortar (1:3) on ceiling surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M&L for applying bond coat of epoxy bonding agent & cement mortor in 1:1 ratio for bonding old and new concrete on damaged surfaces applying ready mix polymer modified mortar upto 60mm thickness (Chajjas fins, border,slab, beams etc) :- (i) Including application of rust remover on exposed reinforcement and subsequent application of anticorrosive coating. Also, pressure grouting with epoxy injection after application of polymer modified mortar. (ii) Use of electrical mixer to get the homogeneous dough on bond coat surfaces. (iii) To achieve required thickness repeat this step after 24 hrs as required. (iv) Keep the surfaces moist using water forg for 5 to 7 days etc complete all as specified and as directed. (v) Rate shall be inclusive of all necessary scaffolding for building height up to 24 meters complete all as directed by Engineer-in-Charge. Make of Chemicals : - Epoxy bonding agent, Rust remover, Anti corrosive coating, Polymer modified mortar, Epoxy grout shall be of Berger Krishna/Dr Fixit/MC Bauchemie & M/s Cemistik/Sika or Equivalent as approved by GE. Notes : (i) Complete treatment to be executed by approved applicator (Applicator to be approved by GE). (ii) The Contractor and manufacture of polymer modified mortar shall give the warranty before commencement and also for the strengths achieved in the post completion of work. (iii) The chemicals to be used in the work shall be certified by the manufacturer with whom the MOU been entered into. (iv) Hard drawn steel wire fabric will be measured and paid seperately. complete all as specified and directed.
M&L for Water proofing treatment to sunken floors of kitchen, toilets, laboratories, bath and WC's etc shall be as under :- (i) Application of Two component Acrylic modified Cementitious coating (aa) The surfaces to be applied shall be completely dry and free from containments such as dirt, dust, oil, surface treatments and old coatings. Concrete substrates must be mechanically prepared using abrasive blast cleaning or milling to remove cement laitance, existing coatings and achieve a gripping profile that is clean, dry and free from litance and any other form of surface contamination. The installation instructions in manufacturer's published literature should be strictly complied with including but not limited to the following:- (bb) Chipping out any visible cracks in "V-Groove" pattern as applicable. Special attention on this part Cleaning of cracks & then filling those cracks with SIKA latex SBR 100 putty/ Dr Fixit 302 SBR late Perma latex SBR / FOSROC Nitabond SBR latex / Asian Paints latex as required. Final cleaning surface with power grinder, wire brush, hair brush & vacuum pressure if required. (cc) Dampen all surfaces immediately ahead of application of Acrylic modified Cementitious coating Sika Top Seal - 107/ Brush Bond FOSROC/ Dr Fixit/ STP/CICO. (dd) Whilst the surface is still damp from saturation (S.S.D), apply one coat of Acrylic mo Cementitious coating of Sika Top Seal - 107 / Brush Bond FOSROC/ Dr Fixit/ STP/CICO of vis as per manufacturer's instructions. (ee) Apply Glass Fabric Sheet of Sika Fab 1/FOSROC/ Dr Fixit/ STP whilst the first coat is wet (ff) Once touch dry, apply second coat of Acrylic modified Cementitious coating of Sika Top Sea /Brush Bond FOSROC/ Dr Fixit/ STP/CICO of viscosity as per manufacturer's instructions entire area. (gg) Second coat shall be applied after 6-8 Hrs of application of previous coat and in the direct angle to the previous coat. (hh) The waterproofing coating should be taken to a height minimum 300 mm above the floor finish level on the vertical surface. (jj) It is essential to cure Acrylic modified Cementitious coating immediately after application 3-8 Hrs drying) for a minimum of 3 to 5 days to ensure full cement hydration and to minimize leakage/seepage. (kk) A protection plaster (12-15mm thick) in CM 1:3 admixed with appropriate Integral water proofing Compound has to be applied on the walls Admixture :- Sika plastocrete plus/FOSROC/Dr Fixit/STP/CICO confirming to IS 2645 Providing and applying a protection screed of 50 mm thick 1:4 cement sand mortar admixed with Sika plastocrtete over applied water proffing coating on horizontal surface. Admixture :- Sika plastocrete plus/FOSROC/Dr Fixit/STP/CICO confirming to IS 2645 (ii) All the corners and joints should be pretreated with elastic waterproffing sealing tape with a woven bonding on each surface an elastic expansions zone in the centre of make sika Tape S/FOROC/Dr Fixit/STP (mm) The membrane has to be protected in accrodance with the manufacture's recommendance until placemnent of concrete. The membrane to be inspected for damage just prior to concrete placement and make repairs in accrodance with manufacturer's recommendations. (nn) Waterproffing treatement has to carried out through applicators authorisrd. (ii) All the joints of pipesand traps within sunken portion shall be sealed properly by Epoxy sealant. (iii) All CI traps in sunken slab to be enclased with PCC 1:1:5:3 ( Min 15 cm) all - round. (iv) the sunken portion shall be filled with PCC 1:5:10 type E-2 (using 40 mm stone aggregate) complete all as specified. (v) Providing drainage spout pipe GI 40 mm dia bore light grade upto outside of outer wall (approx 450 mm to 600 mm long) including cutting to existing wall and making good the distrubed surface complete all as specified and directed. (vi) Providing 25 mm thick cement concrete 1:2:4 type B-0 using 12.5 mm grade stone aggregate as in flooring for laying fllor finish all as specified. Note ;- Item No 116 (aa) to (nn) shall be measured and paid in this item only, no extra item be taken for these items.
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.20 kg per sqm over a coat of bitumen primer @ 0.30 litre per Sqm including preparation of roof surfaces and all surfaces of sunken portion complete all as specified and directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and directed.
M&L for preparation of surfaces of platered, brick, concrete, polymeric etc, of any description, over10cm in width or girth,not otherwise describedone and applying two coats of Solar Reflective Bituminous Aluminium paint @0.1 Kg/ Sqm over APP Membrane complete all as specified and directed.
M&L for 40mm thick brick tiles laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed.
M&L for 40mm thick brick tiles (EXCEPT TILES) laid on mud mortar or mud phuska and joints grouted flush and pointed flush as the work proceeds in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed. Note:- Old seviceable tiles shall be re-used retrieved after dismantling brick tiles on roofs/terrace.
S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed.
S&F 0.50mm thick Pre- painted galvalume aluminum zinc coating GI based plain steel sheetof an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed.
M&L for preparing new plastered surfaces of walls and distempering with two coats of distemper oil emulsion white or tinted over 01mm thick plaster of paris putty to prepare surface even and smooth complete all as directed.
M&L for preparing new plastered surfaces of walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed.
M&L for complete removal of existing treatment on walls and distempering with two coats of cement base paint over one coat of alkali resistant cement primer complete all as specified and directed.
M&L for complete removal of existing treatment on walls and distempering with two coats of distemper oil emulsion white or tinted over 1mm thick plaster of paris putty to prepare surface even and smooth complete all as directed.
M&L for preparing new plastered surfaces of walls and applying three coats of lime white wash complete all as specified and directed.
M&L for preparing new plastered surfaces of ceiling and applying three coats of lime white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of walls and applying one coat of cement base paint complete all as specified and directed.
M&L for preparing old surfaces decorated plastered or unplastered surfaces of walls and applying one coat of lime white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of ceiling and applying one coat of lime white wash complete all as specified and directed.
M&L for preparation of new wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer zinc chromate complete all as specified and directed.
M&L for preparation of old wood or wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of old steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed. Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
S&F 110mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.Note:- Only Pipe along the centre line shall be measured and paid except fittings and accessories which shall be measured and paid for separately under respective items.)
S&F 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F Stack clamps for 100mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F Stack clamps for 75mm dia pipe made out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F 15mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed.
S&F 20mm bore Galvanised Medium Grade Steel Water Tubing with all fittings and connections fixed complete to walls and celling or laid in floor, complete all as specified and directed.
Fixing only old retrieved serviceable 15mm bore Galvanised Medium Grade Steel Water Tubing and fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed.
Fixing only old retrieved serviceable 20mm bore Galvanised Medium Grade Steel Water Tubing and fixed to walls,and ceilings or laying in floors in new or old position with and including new fittings and connections complete all as specified and directed.
S&F in repairs 15mm bore Bib Taps, fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F 15mm bore Bib Taps, long body fancy type, chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F 15mm bore concussive push button taps 15mm bore dia of cost copper alloy, suitable for urinals screwed for iron pipe complete all as specified and directed.
S&F in repairs 15mm bore fancy type, chromium plated, Stop valves, cast copper alloy, with long shank and cup concealed type, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and directed.
S&F 15mm bore Pillar Taps, fancy type, chromium plated, cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F 32mm bore PVC waste pipe of suitable length to waste coupling pipe attached with rubber ring joints/ PVC threaded cup, fixed to waste coupling of sinks / WHBs complete all as specified and directed.
S&F 32mm bore Waste fittings of chromium plated brass p for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed.
S&F 15mm PVC connections 450mm long heavy duty with brass nuts adaptors and washers and rubber gaskets at both ends complete all as specified and directed.
S&F 15mm bore Angle Valves, fancy type, chromium plated, cast copper alloy, with flange, one way turn, screwed down high pressure, with crutch or butterfly handle, screwed for iron pipe complete all as specified and directed.
S&F in replacement 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule histed and fixed including dismentling and taking down old unserviceable water tank capacity 500 litres complete as specified in SSR Part-I. complete all as specified and directed.
S&F in replacement 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), three layered, ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. including 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule histed and fixed including dismentling and taking down old unserviceable water tank capacity 1000 litres complete as specified in SSR Part-I. complete all as specified and directed.
S&F in repairs Wash Hand Basins, Vitreous China (flat back) white of size 550mm X 400mm including cutting for and pinning in ends of brackets or erecting stand including waste fittings, 32 mm bore PVC flush pipe with long screwed shucks and fly nuts and including PVC discharge pipe complete all as specified and directed.
S&F in repairs Vitreous China Squatting Pan, "Orissa pattern", size 580x440mm white/ coloured with integral foot rests (excluding flushing cistern, flush pipe and waste pipe), including trap and connection to trap, and to flushing pipe, anti-syphonage pipe, etc.complete including all joints and making good to floors complete all as specified and directed.
S&F in repairs Vitreous China Wash Down Water Closet Pan (pedestal pattern) complete, white/ coloured including seat and cover, trap, including connection to drain (or outgoing pipe), and to flushing pipe, anti-syphonage pipe, etc. etc.complete including all joints and making good to floors complete all as specified and directed.
S&F in repairs Vitreous China urinals, half stall (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete including all joints and making good to floors complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet galss shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and directed.
S&F Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms)complete all as specified and directed.
S&F 32mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm 45gms/40mm-60 gms) complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mmcomplete all as specified and directed.
S&F in repair Stainless steel plate rack of standard pattern & of size 900 x 750 x 250 mm.The thickness of stainless steel sheet shall be 1.00 mm & grade of sheet shall be 304 AISI including fixing to wall with 4 Nos 50mm screws & PVC rawl plugs complete all as specified and directed.
S&F in repairs 10 litres capacity low level PVC valveless syphonic action type flushing cistern with inlet ball valve, float and handle including brackets complete all as specified and directed.
S&F in repairs grating doom 125mm dia of PTMT with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
S&F in repairs grating doom 100mm dia of PTMT with waste hole of PTMT. (Minimum weight 40gms) complete all as specified and directed.
S&F in repairs 125mm dia Chromium plated brass shower rose with swivel joints, any colour including shower arm 15mm dia, 195mm long with bend of 45 degree with flange of chromium plated brass including fixing complete to steel pipe or union complete all as specified and directed.
S&F in repairs Towel Rail 20mm dia brass chromium plated 600mm long between flanges type "D", with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms)complete all as specified and as directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs chromium plated steel soap dish not less than 1mm thickness fixed with chromium plated steel screws and PVC gutties complete all as specified and directed.
S&F in repairs PVC Bathroom cabinet with mirror of size 450x 600 mmfixed to wall with chromium plated steel screws and PVC gutties complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in concrete bed for 150 mm bore reinforced cement concrete pipes including packing under haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
S&F 150 mm bore Reinforced concrete pipes, class NP-2, laid and jointed complete with collars laid in trenches and jointed complete all as specified and directed. Note:- Excavation, Earth work and Concrete bed shall be measured and paid separately)
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and sinking boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully.
ditto all as per item No 160 above but for one socket outlet on the same board controlled by one single pole one way switch
ditto all as per item No 160 above but for one 5 amps socket outlet independent controlled by one single pole 5 Amp switch.
M&L for point wiring with PVC insulated but unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) one three pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sinking boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully.
S&F 5/6 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed.
S&F 15/16 Amp Switch piano flush type single pole one way ISI Marked complete all as specified and directed.
S&F 5/6 Amp Socket outlet 2 in1, 3 pin flush type ISI marked complete all as specified and directed.
S&F 15/16 Amp Socket outlet 2 in 1, 3 pin flush type ISI marked complete all as specified and directed.
S&F 5/6 Amp bell push flush type ISI marked complete all as specified and directed.
S&F Ceiling Roses Ceiling rose, 3 phase/PVC/polycarbonate, isolated body omplete all as specified and directed.
S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed.
S&F bell, Ding Dong AC. 230 Volts, single pole complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
S&F 300mm sweep Exhaust Fan, steel body AC single Phase. 230V with blades and frame and louvers with Copper winding including cutting holes/ opening, grouting bolts, fixing with nuts and washers and making good in cement mortar (1:4) and finshing surfcae to match with existing surfaces complete all as specified and directed.
S&F LED tube light fitting 1 X 18 W decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Cat Part No. LHEXBLP7UN1W018 of Make - Havells or equivalent as specified in Appendix "B" of Particular Specfications, complete all as specified and directed..
S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired TPN DBs, 415 Volts 200Amps rated bus bar,Neutral link,Earth bar and Din rail, 4 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
S&F sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified.
S&F Moulded Case Circuit Breaker (MCCB) Four Poles (FP) current carrying capacity 100Amp, 415 Volts, breaking capacity 16 KA with adjustable thermal and magnetic settings, complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 40Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 40 to 63Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
S&F Single Pole two Pin and Earth Plug and Socket including one single pole MCB 20 Amp fixed in sheet Metal enclosures complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 4.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 4.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 4.0Sqmm and one run of 4.0Sqmm PVC insulated copper conductor single core (2x4.0Sqmm+1x4.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
M&L for submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run)
Supply, lay, test, joint and commission LT XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric powercable heavy duty with aluminium conductor of size cross sectional area 25Sqmm x 4 core, 1100 Volts grade (1.1 KV earthed system); laid in trenches/under floor/through ducts, on Hill / fixed on pole complete all as specified and directed. Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe shall be measured and paid separately under respective items of BoQ.
Supply and lay 40mm bore galvanised pipe light grade of ISI marked for passing of cable fixed to poles/walls/laid under floor/ laid in trenches as cable protection complete with and including fittings as required compete all as specified and directed.Note:- Excavation & Earth work, sand cushioning, cable protection cover, pipe and joint shall be measured and paid separately under respective items of BoQ.
M&L for Sand cushioning using sand suitable for plaster works to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep punned to 10cm after laying and stretching the cable complete all as specified and directed. Note : 18 cm punned thickness shall be measured and paid.
Supply and lay cable protection cover with Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75, (size 23cmx11.5cmx7.5cm) putting accross the cable with width of protection cover equal to length of brick, abutting to each other for cable protection complete all as specified and directed.
M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed. Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate. (iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Vee Vee Enterprises (BID ID -3399061)
M/S Pee Kay Builders (BID ID -3402849)
M/S CHAWLA CONSTRUCTION COMPANY (BID ID -3403179)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .