Chief Officer Engineering
Administrative Building, IIM Indore
Renovation (Civil and Electrical) of Hostels SR-01 to SR-06 comprising 383 Rooms at IIM Indore (Re-tender)
2026_IIMID_896411_1
IIMI/Estate/04/2026/267 File no. 587
Open Tender
Civil Works
Item Rate
60 days
IIM Indore
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹4.7 L
IIM Indore
27 Feb 2026
31 Jan 2026
14 Feb 2026
31 Jan 2026
13 Feb 2026
31 Jan 2026
5 Feb 2026
(Civil works item sr.no. 1 to 10) Scrapping:- Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Putty: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. Note: -The putty surface must be perfectly smooth and even, without any undulation. Painting work will be allowed only after inspection and approval by the Engineer-in-Charge.
Primer:- Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Paint:- Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats (Make :- Royale Luxury Emulsion Shyne-Asian paint/Velvet Touch Diamond Glo-Dulux Paint) Note:- Masking tape shall be used before starting the painting work to protect aluminium/MS frames and Electrical Equipment.
Enamel paint:- Painting with synthetic enamel paint (at all height) of approved brand and manufacture of required colour to give an even shade : One or more coats on old work including removing of the old paint. Note:- * Making Texture shall be provided with a touch of wood, as directed by the Engineer-in-Charge. * Skirting shall be painted with enamel paint as per approved vinyl flooring shade i.e Grey
Vinyl Flooring:- Supply and laying of 2 mm thick fire-resistant, termite-proof, moisture-proof Poly Vinyl Flooring with PVC base and UV layer of approved quality over the existing Flooring & Skirting, including surface preparation, levelling of existing wooden base, application of suitable adhesive, and finishing; (Make: Wonderfloor /Merino/ Armstrong)- 2 mm Technical Specifications not less than:- Thickness- 2.00 mm Wear layer-0.25 mm (Heavy Duty) Type of flooring :- Resilient Flooring Total weight kg/Sqm:- 3.6+/- 5% Flammability:- should be passed as per IS 15061 Moisture Movement:- +/-< 0.40% Slip Resistance:- R9 Horizontal & Vertical Burning Test :- PASS (ARAI)
Resistance to Staining :- PASS Pattern:- Roll (as per approved brand and manufacturer & direction by Engineer-in-charge) Width of Roll:- 2 mtr. Length of Roll:- 15 mtr. Note:- * length & width may be varied as per manufacturer specification. * Pasting of vinyl flooring shall be carried out using approved adhesive Make :-SR-998, 3M, Dow on the floor surface complete as per manufacturer’s specifications and directions of the Engineer-in-Charge.
(Film on ventilation): Providing & fixing translucent film (3 M and Garware film) on glass of approved quality & make and as per the direction of Engineer-in-charge.
Supplying & Installation of Roller Blinds (Black out Venice) as per direction of the engineer in charge. Technical Specifications Pattern & Colour - as approved by Engineer-in-charge. Composition - 100% Polyester Coating:- Blackout 3 Pass Foam Coating Fabric Thickness +/- 5%:- 0.05mm Fabric Weight 400 gsm +/- 5% EPI/PPI:- 178/66 Care Instruction - Spongable (Fire Classification - NFPA 701-200+TN#1) Mechanism Specifications - Tube diameter not less than 43 mm diameter with stabilizer profiles inside. Manual control via pvc thread operated open/close system. Fixed to walls with bracket. Powder coated Aluminium bottom bar with caps on both ends. Load capacity - Minimum 2 Kg/linear meter (Make- Johnson Blinds, Vista (Black out Venice)
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts, Pelmet etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Exterior paint work at corridor of hostels (SR-01 to SR-06) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade Old work (one or more coats applied @ 0.83 ltr/10 sqm). (Make:- Asian-Apex Ultima /Dulux Paint- Weather Shield)
(Electrical works item sr.no. 11 to 28) Supplying and fixing 4 Module (125mm X 75mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. Make -Legrand, Model- Arteor/ABB-IVIE
Supplying and fixing of 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Supplying and fixing of 3 pin 15/16 A Modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Supplying and fixing of 4 Modular base & cover plate on existing modular metal boxes etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. wire make- Polycab/phinolex
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Supplying and fixing 1/2 Module (75mm X 75mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Supplying and fixing of 1/2 Modular base & cover plate on existing modular metal boxes etc. as required. Make Legrand, Model- Arteor/ABB-IVIE
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group-C (the contractor will provide the conduit and wire as per the site requirement & will be payable on account of contractor. wire make- polycab/phinolex
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required Make Legrand, Model- Arteor/ABB-IVIE
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 1 Run of cable. Make:- Finolex/Molex/Legrand
Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. Make Legrand, Model- Arteor
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm Size make- polycab/phinolex
Supply, Installation, Testing and commissioning of 32W Mirror Light | Photon 4ft LED Indoor Wall Light Make/Model:- Philips/919215850968
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required or LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Make- Philips/equivalent
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire make- Phinolex/polycab
Supply, Installation, Testing and commissioning of 1 Uno wall lamp Complete with all accessories. (3W, 3000K) Make: Philps, Model No. B22 /Havells
Supply, Installation, Testing and commissioning of Trim Cosmo LED Surface panel round Complete with all accessories. (18W, 4000K) Make/Model: Havells/RMSDL-18W or equivalent in Philips (For Corridor lights)
Supply, Installation, Testing and commissioning of 1 nos of 5 Watt table lamp CDL make/Model -Philips-581913 /Havells- Moderna
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.59 MB
BOQ_942205.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .