| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest. | |
| 2 | L2₹45.0 L+₹2.2 L (5.19%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-AOC Being other than lowest. | |
| 3 | L3₹47.9 L+₹5.1 L (12.0%)Rejected-AOC 1ST FLOOR PRABHA SHOPPING COMPLEX OLD PAHARGAON DOLLYGUNJ PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 UDYAM AN 01 0000143 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-AOC Being other than lowest. | |
| 4 | L4₹48.1 L+₹5.3 L (12.4%)Rejected-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L4 | Rejected-AOC Being other than lowest. | |
| 5 | L5₹48.8 L+₹6.0 L (14.1%)Rejected-AOC | L5 | Rejected-AOC Being other than lowest. |
| Sl No | Description | Qty | Unit | Tropical Refrigeration L4 | Ravi Enterprises L6 | SKY GROUP L5 | Kakolil Trade Agencies L7 | Prasur Electricals & Engineering Co. L2 | Shova Electricals L8 | OPS Associates L1 | Island Agency L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for manufacturing, installation testing and commissioning of synchronization / AMF panel suitable for synchronising 4 Nos DG sets 1010KVA-01 No, 600KVA-01 No, 500KVA-01No & 400KVA-01 No panel, indoor type, double door, cubical type, padestal mounted, of suitable size, CPRI approved having, IP 65, independent compartment for bus bar, incoming feeder and each out going feeders, totally dust and vermin proof with front and rear openings & lockable, factory made, fabricated out of of 3.15 mm thick CRCA Sheet confirming to IS 8623 & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements suitable for 3 Phase 415 volts 50 Hz, AC supply 415/440, 3 phase, 4 wire AC 50Hz having copper bus bar capacity required to carry current 110% load with three phase and half neutral colour coded, prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following accessories:- | 1 | Each Job | 46,25,000 ₹46,25,000 | 47,45,000 ₹47,45,000 | 47,00,000 ₹47,00,000 | 47,95,550 ₹47,95,550 | 42,77,750 ₹42,77,750 | 48,25,000 ₹48,25,000 | 40,45,000 ₹40,45,000 Lowest | 45,99,900 ₹45,99,900 |
| 1.10Incomer DG set 1010KVA: 1. 1600A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 1600/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4 | |||||||||||
| 1.20Incomer DG set 600KVA: 1. 1000A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 1000/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4 | |||||||||||
| 1.30DG INCOMER DG - 500KVA: 1. 800A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 800/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4 | |||||||||||
| 1.40DG INCOMER - 400KVA: 1. 800A, 4pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 800/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4 | |||||||||||
| 1.50Bus Coupler - 2000 A 4 pole ACB: 1. 2000A 4pole EDO ACB 50KA MP based with O/C, S/C & E/F Protection - 1.0 2. Breaker control switch with TNC Salzer 1.0 3. UV release Coil 240V AC L&T 1.0 4. Indicating lamp ON/OFF/TRIP Esbee 1.0 5. 6A SP Control MCB 10KA C-Curve L&T 1.0 6. Terminal Block Elmex 1.0 | |||||||||||
| 1.60INCOMER INTERLOCKING - 1 No 1. Electrical Interocking between Mains incomer, DG Incomer & Bus coupler ITE 1.0 PLC BASED Synchronising & AUOYO LOAD SHARING 1. Aom Ap Synchronising controller CAmAp InteliVision Color display InteliField Bus Gateway 2. PLC for Interlocking Delta 1.0 3. SMPS 24V, 4 Amp GIC 1.0 4. VMR GIC 1.0 5. Aux Contactors 2 No 2 NC 230V AC L&T 5.0 6. Add on Block 2 No 2 NC 230V AC L&T 2.0 7. 16A DP MCB L&T 3.0 8. 12/24V, 10 Amp DC Battery Charger PCS 3.0 9. UPS 650 KVA Microtech 1.0 10. Cooling Fan 6" Rexnord 4.0 11. Space Heater with Thermostat Reputed 4.0 12. DG start/Stop Push Button Esbee 6.0 13. Auto/Manual Operated Salzer 3.0 14. Terminal Block - Lot | |||||||||||
| 1.70OUTGOING 2000A 4 Pole ACB - 1 Nos 1. 2000A 4 Pole EDO ACB 50KA MP based with O/C, S/C & E/F Protection L&T 2.0 2. Indicating lamp ON/OFF/TRIP Esbee 3.0 3. 6A SP Control MCB 10KA C-Curve L&T 3.0 | |||||||||||
| 1.80GENERAL ITEMS: Steel Fabricated Body made out of 2/1.6 mm Thick CRCA Sheet Steel duly Powder Coated ITE 1.0 2. Alu. Bus bar 2000A with Support duly Heat shrinkable PVC sleeved, Hindalco Lot 3. Hardware & Accessories Reputed Lot 4. PVC wiring RR Cabel Lot 5. Programming ITE | |||||||||||
| 2.00 | Supply & fixing Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead, by means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified & directed .
Notes:Quoted rates shall be deemed to be included the following
(a) Excavation ,RFR earth work in any type of soil.
(b) PCC pit in cement concrete 1:3:6 type C-1, pre cast RCC cover 40 mm thick in PCC 1:2:4 type B-1, reinforced with 8mm dia TMT bars @ 100mm centre to centre both ways with suitable handle made of 10mm dia round bar.
(c) funnel with wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed.
(d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified & directed.
(e) Requisite quantity of common salt and charcoal in alternative layers as specified. | 2 | Each Job | 30,000 ₹60,000 | 25,000 ₹50,000 | 33,500 ₹67,000 | 20,000 ₹40,000 Lowest | 26,777 ₹53,554 | 22,500 ₹45,000 | 25,000 ₹50,000 | 35,000 ₹70,000 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
2 Dec 2025, 6:00 pmClosed
GE (I) 866 EWS CARNICOBAR
GE(I)866 EWS CARNICOBAR PIN-913866 C/O 99APO
SPECIAL REPAIR /REPLACEMENT OF DG SET SYNCHRONIZATION PANEL IN CAPTIVE POWER HOUSE AT AF STATION CARNICOBAR
2025_MES_738397_1
8756/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) 866 EWS CARNICOBAR AIR FORCE STATION
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) 866 EWS
₹84,000
Yes
16 Mar 2026
4 Nov 2025
9 Dec 2025
4 Nov 2025
2 Dec 2025
25 Nov 2025
4 Nov 2025 - 11 Nov 2025
Amount
Material and labour for manufacturing, installation testing and commissioning of synchronization / AMF panel suitable for synchronising 4 Nos DG sets 1010KVA-01 No, 600KVA-01 No, 500KVA-01No & 400KVA-01 No panel, indoor type, double door, cubical type, padestal mounted, of suitable size, CPRI approved having, IP 65, independent compartment for bus bar, incoming feeder and each out going feeders, totally dust and vermin proof with front and rear openings & lockable, factory made, fabricated out of of 3.15 mm thick CRCA Sheet confirming to IS 8623 & MS angle iron section of 50X50X6 mm frame, front operated with locking arrangements suitable for 3 Phase 415 volts 50 Hz, AC supply 415/440, 3 phase, 4 wire AC 50Hz having copper bus bar capacity required to carry current 110% load with three phase and half neutral colour coded, prewired with copper cable of suitable size all as standard practice of manufacturer specifications with the following accessories:-
Incomer DG set 1010KVA: 1. 1600A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 1600/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4
Incomer DG set 600KVA: 1. 1000A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 1000/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4
DG INCOMER DG - 500KVA: 1. 800A, 4 pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 800/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4
DG INCOMER - 400KVA: 1. 800A, 4pole EDO ACB 50KA MP based with O/C & E/F protection - 1 2. UV Release Coil 240V AC - 1 3. TNC - Breaker Control switch - 1 4. Digital MFM with RS-485 EM6400NG - 1 5. CT - 800/5A, 15VA - 3 6. CT shorting link - 8 7. Phase Indicationg lamp R-Y-B -1 8. Indicating lamp ON/OFF/TRIP - 3 9. 6A SP control MCB 10KA C Curve - 5 10. Terminal block - 4
Bus Coupler - 2000 A 4 pole ACB: 1. 2000A 4pole EDO ACB 50KA MP based with O/C, S/C & E/F Protection - 1.0 2. Breaker control switch with TNC Salzer 1.0 3. UV release Coil 240V AC L&T 1.0 4. Indicating lamp ON/OFF/TRIP Esbee 1.0 5. 6A SP Control MCB 10KA C-Curve L&T 1.0 6. Terminal Block Elmex 1.0
INCOMER INTERLOCKING - 1 No 1. Electrical Interocking between Mains incomer, DG Incomer & Bus coupler ITE 1.0 PLC BASED Synchronising & AUOYO LOAD SHARING 1. Aom Ap Synchronising controller CAmAp InteliVision Color display InteliField Bus Gateway 2. PLC for Interlocking Delta 1.0 3. SMPS 24V, 4 Amp GIC 1.0 4. VMR GIC 1.0 5. Aux Contactors 2 No 2 NC 230V AC L&T 5.0 6. Add on Block 2 No 2 NC 230V AC L&T 2.0 7. 16A DP MCB L&T 3.0 8. 12/24V, 10 Amp DC Battery Charger PCS 3.0 9. UPS 650 KVA Microtech 1.0 10. Cooling Fan 6" Rexnord 4.0 11. Space Heater with Thermostat Reputed 4.0 12. DG start/Stop Push Button Esbee 6.0 13. Auto/Manual Operated Salzer 3.0 14. Terminal Block - Lot
OUTGOING 2000A 4 Pole ACB - 1 Nos 1. 2000A 4 Pole EDO ACB 50KA MP based with O/C, S/C & E/F Protection L&T 2.0 2. Indicating lamp ON/OFF/TRIP Esbee 3.0 3. 6A SP Control MCB 10KA C-Curve L&T 3.0
GENERAL ITEMS: Steel Fabricated Body made out of 2/1.6 mm Thick CRCA Sheet Steel duly Powder Coated ITE 1.0 2. Alu. Bus bar 2000A with Support duly Heat shrinkable PVC sleeved, Hindalco Lot 3. Hardware & Accessories Reputed Lot 4. PVC wiring RR Cabel Lot 5. Programming ITE
Supply & fixing Earthing complete with copper earth plate electrode 60cm×60cm× 3.15mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead, by means of bolts, nuts, check nuts and washers of brass or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified & directed . Notes:Quoted rates shall be deemed to be included the following (a) Excavation ,RFR earth work in any type of soil. (b) PCC pit in cement concrete 1:3:6 type C-1, pre cast RCC cover 40 mm thick in PCC 1:2:4 type B-1, reinforced with 8mm dia TMT bars @ 100mm centre to centre both ways with suitable handle made of 10mm dia round bar. (c) funnel with wire mesh , watering pipe of GI 20 mm nominal bore light grade and lugs etc. complete all as specified & directed. (d) 32 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified & directed. (e) Requisite quantity of common salt and charcoal in alternative layers as specified.
M&L earth continuity condcutor or main earthing lead fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc 20 x 3mm copper strip complete all as specified and directed.
Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel strip or wire armoured electric power cable conforming to IS:7098 (Pt-I)-1988, heavy duty with stranded aluminium conductor 1100 Volts grade of size 300 Sqmm 3.5 core with necessary fixing arrangements such as lungs, glands and terminal etc including connecting/testing after taking out unserviceable LT UG cable from trenches/ pole complete all as specified and directed. NOTE: Excavation, earth work shall be measured and paid for separately.
Schedule of Credit (Minus) Rs.16500.00 NOTE: Bidder shall insert credit amount of Rs. 16500.00 as rate in Green field under Col-13.
Prasur Electricals & Engineering Co. (BID ID -3487955)
Island Agency (BID ID -3487826)
Tropical Refrigeration (BID ID -3487518)
SKY GROUP (BID ID -3487676)
Ravi Enterprises (BID ID -3487597)
Kakolil Trade Agencies (BID ID -3487744)
Shova Electricals (BID ID -3487719)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8756.pdf
Tender Documents • 0.91 MB
BOQ_826794.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .