| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | ₹26.4 L Quoted ₹27.0 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹27.0 LRejected-Finance | ₹27.0 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹28.7 LRejected-Finance | ₹28.7 L | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹29.5 LRejected-Finance | ₹29.5 L | L4 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | ESKIMO COOL WORLD L3 | BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS L1 | Maruti Abhiyantriki L2 | K K ENGINEERING SERVICES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | M & L for attending emergant complaints by experienced refregeration machanic i.e. partaining to Centre AC Plant / Packages Type AC plant/ VRF / Type AC plant of any Capacity including carry out minor repairs and identification of fault etc as required to system in order/functional complete all as specified and direted by Engr-in-Charge.
Note - Major Spare parts will measured and paid seperately under relavent item, complaints as supply and fixing should be attended within 24 Hrs. | 150 | Each Job | 1,500 ₹2.3 L | 1,000 ₹1.5 L | 1,200 ₹1.8 L | 1,800 ₹2.7 L |
| 2.00 | M&L for replacement of unserviceable fan blade of outdoor condenser unit of air cooled package/ central type AC plant (5 to 7.5TR) as per existing make, model and type complete all as specified and directed by Engr-in-charge. | 2 | Each Job | 2,100 ₹4,200 | 1,750 ₹3,500 | 650 ₹1,300 | 750 ₹1,500 |
| 3.00 | S&F for in replacement of existing unsv VLRP controller of chiller unit 15 to 36 TR cap testing, calibrating the functions with plant after replacement complete all as specified and directed by Engr-in-charge. | 4 | Each Job | 25,000 ₹1 L | 22,000 ₹88,000 | 36,500 ₹1.5 L | 34,600 ₹1.4 L |
| 4.00 | M&L for servicing of pan type humidifier floor mounted/ installed at duct of capacity 6 /12 kW including cleaning of tank, checking of all inlet & outlet connection, checking and repair of all electrical control connections and making the pan type humidifier functional including replacement of heating elements of existing make & model, replacment of minor parts complete all as specified and directed by Engr-in-charge. | 8 | Each | 2,000 ₹16,000 | 1,200 ₹9,600 | 1,950 ₹15,600 | 2,250 ₹18,000 |
| 5.00 | M&L for replacement of HP/LP cut out suitable for compressor (5 to 18 TR) of package/central type AC plant including cutting, brazing and leakage testing complete as required at site and testing after replacement complete all as specified and directed by Engr-in-charge | 6 | Each | 2,200 ₹13,200 | 1,200 ₹7,200 | 950 ₹5,700 | 950 ₹5,700 |
| 6.00 | Supply & fixing PVC fills of cooling tower 20 to 100 TR as per OEM standard fixing secquance including cutting & filling the gaps so that the water of cooling tower spread equally includng refixing motor, pipe, sprinkler complete all as specified and directed by Engr-in-charge. | 10 | Each Job | 18,000 ₹1.8 L | 14,000 ₹1.4 L | 8,500 ₹85,000 | 14,000 ₹1.4 L |
| 7.00 | M&L for replacement of defective temp sensor of chiller line as per existing make & model complete all as specified & directed by Engr - in- Charge. | 20 | Each | 1,200 ₹24,000 | 1,050 ₹21,000 | 450 ₹9,000 | 500 ₹10,000 |
| 8.00 | M&L for replacmnet of defective temperature controller with sensor including making proper wiring & connections complete all as specified suitable for existing & directed by Engr - in- Charge. | 4 | Each | 2,850 ₹11,400 | 1,750 ₹7,000 | 1,100 ₹4,400 | 1,100 ₹4,400 |
| 9.00 | M&L for replacmnet of defective humidity controller with sensor including making proper wiring & connections complete all as specified & directed by Engr in Cahrge. | 4 | Each | 3,500 ₹14,000 | 3,500 ₹14,000 | 4,250 ₹17,000 | 4,150 ₹16,600 |
| 10.00 | M&L for replacment of unsv flow switch of chiller & condensor line 63 to 200mm dia line , including making all control conections suitable for existing complete all as specified & directed by Engr in Charge. | 3 | Each | 1,500 ₹4,500 | 1,200 ₹3,600 | 3,400 ₹10,200 | 3,500 ₹10,500 |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
8 Oct 2025, 6:00 pmClosed
COL S P SINGH
CWE AF LOHEGAON, PUNE - 411032
MAINTENANCE, REPAIR AND REPLACEMENT OF UNSERVICEABLE ITEMS OF CENTRAL AC PLANTS, PACKAGE TYPE AC PLANTS, ELECTRICAL PANELS, DUCTING AND MISC ITEMS OF AC PLANTS UNDER GE (AF) LOHEGAON AT 2 WING AF STN PUNE
2025_MES_730588_1
81976/E8
Open Tender
Civil Works
270 days
GE AF LOHEGAON
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF LOHEGAON
₹60,000
Yes
24 Dec 2025
12 Sept 2025
15 Oct 2025
12 Sept 2025
8 Oct 2025
26 Sept 2025