Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC | L1 | Accepted-AOC Accepted as L1 and work awarded | |
| 2 | L2₹16.1 L+₹1.5 L (10.5%)Accepted-AOC 0 MATADIN KAKRAHI KAKRAHI BHARTHANA ETAWA ETAWAH UTTAR PRADESH 206242 | ETAWAH | UTTAR PRADESH | 206242 | L2 | Accepted-AOC Accepted as L2 | |
| 3 | L3₹16.1 L+₹1.5 L (10.6%)Accepted-AOC HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | L3 | Accepted-AOC Accepted as L3 | |
| 4 | L4₹17.7 L+₹3.2 L (21.9%)Accepted-AOC | L4 | Accepted-AOC Accepted as L4 | |
| 5 | L5₹19.7 L+₹5.1 L (35.2%)Accepted-AOC | L5 | Accepted-AOC Accepted as L5 |
Tender Value
₹18 L
EMD Value
₹34,500
Closing Date
7 Sept 2020, 11:00 amClosed
EE JSV Division Barsar
EE JSV Division Barsar
Improvement of distribution system of LWSS Daswin Tihari and Galore Budhwin in Tehsil Nadaun Distt. Hamirpur SH- Supply and Erection of centrifugal Pumping machinery with allied accessories complete at main stage
2020_HPIPH_40183_1
EE-JSVD-BSR-TA-E-T-2020-21- 7433-83
Open Tender
Civil Works
Item Rate
180 days
JSV Sub Division Galore
Please refer Tender documents.
9 documents required · 9 mandatory
₹400
Yes
EE JSV Division Barsar
₹34,500
Yes
20 Nov 2020
29 Aug 2020
7 Sept 2020
29 Aug 2020
7 Sept 2020
29 Aug 2020
29 Aug 2020 - 7 Sept 2020
Amount
Ist stage
Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/ KSB/ Kirloskar /Hindostan as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting raw water for under mentioned characteristics with Bronze impellers /priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squrrel cage induction motor of standard make such as Kirloskar/Crompton/ NGEF/KSB ABB/ HEL /GEC /Seimens/Jyoti and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It shold include the cost of bearing nuts, bolts and painting etc and should meet the following requirement.requirement .
(a)Pumps: Specifications
(i) Make
(ii) Model
(iii) No's of Stages
(iv) Material (manufacures certificate to be appended )
Performances
(i) Head (H) in
(ii) Discharge (Q) in
(iii) BHP absorbed
(iv) Efficiency (n)
(v) NPSH (K)
(b) Motors: (Specification)
(i) Make.
ii) Model
(iii) Motor rating (KW)
(iv) Speed
(v) Insulation :
(c) Coupling:
(d) Base plate.
Discahrge (Q) : -For each pump 9.49 lps or 34.16 Cum/ hours
Total dynamic head :190.35 metres.
(a) LWL in sump well (h) : 500.00 mtr
(b) Shaft level : 500.00 mtr
(c ) Level at discahrge point : 639.00 mtr
(d) Suction lift :
(e) Residual head : 3.00 mtr
(f) Static head : 339.00 mtrs
(i) Rising Main :
(a) Length 1470 mtrs
(b) Dia. :100 mm
(iv) Pumping Hours : 8 hours
(v) Altitude of installation above MSL :400
(vi) Characteristics of water : clear water
(a) Temperature :
(b) Ambient temperature
(c ) Turbidity < than up to 50 ppm NTU
(d) Alkalinity Mg/Ca Co3
(e) Size of the solids mm
(f) Other
Providing ICTP Main Switch with HRC fuses/Side handled operated L & T/ Crompton/ Standard/ Havells make Operational rating as per IS: 4064 ( Part-II) -1978 with up to date amendments. i) Make ii) Model ii) Capacity Suitable Amps
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
Panel/Switch Board:
(i) Drawing
. (ii) Layout plan.
M.C.B. /OCB Havells/MDS/starnded make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516(Part-II) -1985 with up to date amendments with suitable /erange.
(i) Make
(ii) Type
(iii) Range: suitable Capacity
ELR/ELCB of Havell/ Indetec /MDS make as per IS: 2516(Part-II)-1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
(i) Make
(ii) Type
(iii) Range: suitable rating
The voltage monitor relay of L & T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 3842 ( Latest edition of suitable capacity).
(i) Make
(ii) Type
(iii) Range: 380-440 voilts
(i) Make
(ii) Type
(iii) Range: 0-500 V.
Power factor meter of AE/ L& T make square type as per relevant IS codes with up to date amendments of suitable rating. Rate inclusibe in item No. 2 (A) above
(i) Make
(ii) Type
Frequency meter of AE/ L& T make square type as per relevant IS: Codes with up to date amendments of suitable rating. Rate inclusibe in item No. 2 (A) above
(i) Make
(ii) Type
(iii) Range: suitable rating
Bus bar chamber with three copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
ICTP switches with HRC fuses of L & T/ Standard/ Havells make of suitable capacity as per IS: 4064-1978 with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
(i) Make
(ii) Type
(iii) Range: suitable rating
Capacitor of L & T/ Bajaj/ Assian/ Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of suitable capacity to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .
(i) Make
(ii) Type
(iii) Range: suitable rating
Providing star delta starter /L&T/Havels of MEI/ Kilburn make as per IS: 8544-1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release initial oil filling with single phase preventor as per IS 8544 ( Part-II) -1987 with up to date amendments. .
Starter
i) Type starter rooter
ii) Make :
Singal Phase Prevantor
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition) 0-9999 hours .
Hour Run meter
i) Type
ii) Make
iii) Range
Providing double flanged Cast iron sluice valve of Kirloskar/ Leader make of 100 mm dia for the suction pipe and capable of with standing the normal seat pressure and as per 780-1984 ( Part-I) Class PN 1.0 with upto date ammendments ..
i) Make
(ii) Class P.N.I
(iii) Seat pressure : 10.20 Kg Cm2
iv) Material C.I.
Providing double flanged Cast steel sluice valve of Kirloskar/ Leader make one dia higher than pump for the delivery line of the pump and capable of with standing the normal seat pressure and as per relevant IS 1414 API 600 Class ASA -150 with upto date ammendments ..
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing double flanged Cast steel reflux valve of Leader/Kirloskar make and one dia. higher than pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per 1868 API 600 (Class ASA-150) with up to date amendments
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing double flanged Cast steel non return valve of Leader/ Kirloskar make and 100 mm dia.having bye pass arrangement for rising main and capable of with standing normal seat pressure as per 1868 API 600 (Class ASA-150) with up to date amendments
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing 100 mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range suitable range
(i) Make
(ii) Range :0-21Kg/cm2
Installation of all the items appearing at Serial No.01 to 08
Providing and fixing double flanged G.M.S. piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 100 mm dia Min. length = 15 mtr.
(ii) Delivery pipe 80 mm dia -do- = 5 mtr.
(iii) Common Header 100 mm dia -do- = 10 mtr.
(i) Suction pipe GI pipe 100 mm dia (medium class) flanged with MS flanges of table -5
(ii) Delivery pipe GI pipe 80 mm dia (Medium class) flanged with MS flanges of table -28
And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. (iii) Common Header GI pipe 100 mm dia (Medium class) flanged with MS flanges of table 28
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Motor side: 16 mm 2 Min length = 20 mtrs.
Supply side: 25 mm 2 Min length = 10 mtrs.
Providing and fixing double loop earthing and G.I. plate /copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
LWSS Panyali Sareri
Providing horizontal spindle horizontal split casing/end suctions (back pull out arrangement) single/double multistage centrifugal pump or combination of pump in series of recommended make such as Mather and Platt/ KSB/ Kirloskar /Hindostan as per BIS-1520-1980 with up to date amendments, read with IS: 9137-1978 or latest edition suitable for lifting Clear water for under mentioned characteristics with Bronze impellers/priming funnels, casing ring and shaft sleeves of bronze, shaft of steel grade EN-8 with cast iron casing coupled directly through a flexible coupling on a MS/Cast steel base plate ( base plate to be from the manufacturers of the pumping unit only) to Squrrel cage induction motor of standard make such as Kirloskar/Crompton/ NGEF/KSB ABB/ HEL /GEC /Seimens/Jyoti and suitable for operation on 400 (+)/-) 10% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be at least 10% in excess of the maximum power required by the pump in the operation range of (+) 10% and (-) 15% of the duty point head. The motor should be as per IS: 325-1978 with up to date amendments read with IS: 900-1972. It shold include the cost of bearing nuts, bolts and painting etc and should meet the following requirement. (a) pumps: Specifications (i) Make (ii) Model (iii) No's of Stages (iv) Material (manufacures certificate to be appended ) Performances (i) Head (H) in meter (ii) Discharge (Q)in lps/m3/hr (iii) BHP absorbed (iv) Efficiency (n) (v) NPSH (K)
(b) Motors: (Specification)
Discahrge (Q) : - For each pump 11.37 LPS (i) Make
Or 40.93 Cum/Hour
Total dynamic head : 176.42 Mtr (ii) Modal
(a) LWL in sump well (h) : 96.00 Mtr (iii) Motor rating(KW)
(b) Shaft level : 96.00 Mtr (iv) Speed
(c ) Level at discahrge point : 235.00 Mtr (v) insulation
(d) Suction lift : 0.00 Mtrs
(e) Residual head : 3.00 Mtr
(f) Static head : 139.00 Mtr
(i) Rising Main :
(a) Length 1975 Mtr ( C ) Coupling
(b) Dia. : 125 mm (d) Base plate
(iv) Pumping Hours : 8 Hours
(v) Altitude of installation above MSL : 400.00
(vi) Characteristics of water : Clear Water
(a) Temperature : 00.00 o C
(b) Ambient temperature 00.00 o C
(c ) Turbidity Upto 50ppm NTU
(d) Alkalinity mg/Ca Co3
(e) Size of the solids mm
(f) Other
Providing change over Iron clad tripple pole) Main Switch with HRC fuses/Side handled operated L & T/ Crompton/ Standard/ Havells make Operational rating as per IS: 4064 ( Part-II) -1978 with up to date amendments. Change over Switches :- (i) Make (ii) Model (iii) Capacity : suitable Amps
Providing M.S. sheet, steel fabricated floor mounted closed ( Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm, duly painted, with steel sheet of 16 gauge comprising, capable of mounting the following accessories with all internal connections:-
Panel/Switch Board:
(i) Drawing
. (ii) Layout plan.
M.C.B. /OCB Havells/ MDS/starnded make of suitable capacity on incoming feeder with or without initial oil filling as the case may be with neutral linked under voltage releases as per IS: 2516(Part-II) -1985 with up to date amendments withof suitable
(i) Make
(ii) Type
(iii) Range:
ELR/ELCB of Havell/ Indites /MDS make as per IS: 2516(Part-II)-1985 with upto date amendment which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be lifted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end.
(i) Make
(ii) Type
(iii) Range: suitable
The voltage monitor relay of L & T/AE make three phase with all protection and usual indicator and electric siren against single phasing low voltage, high voltage, reverse phasing, over loading and phase voltage difference as per IS: 3842 ( Latest edition).
(i) Make
(ii) Type
(iii) Range: suitable
(i) Make
(ii) Type
(iii) Range: 0-500 V.
Power factor meter of AE/ L& T make square type as per relevant IS codes with up to date amendments of suitable rating. Rate Inclusive in item No. 2 (A) above
(i) Make
(ii) Type
Frequency meter of AE/ L& T make square type as per relevant IS: Codes with up to date amendments of suitable rating. Rate Inclusive in item No. 2 (A) above
(i) Make
(ii) Type
(iii) Range: suitable rating
Bus bar chamber with three copper strips having three bars of suitable rating for full length equal to the width of the board for three live phases and suitable for induced current, one copper bar of half the rating of full length for neutral phase as per IS: 8084-1976 and IS: 11353-1985 read with BIS 5578-1985 with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
ICTP switches with HRC fuses of L & T/ Crompton/ Standard/ Havells make of suitable capacity as per IS: 4064-1978 with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
Three phase indicator lamps complete with toggle switches for individual motors as per IS: 3452 ( P-I&II) with up to date amendments.
(i) Make
(ii) Type
(iii) Range: suitable rating
(i) Make
(ii) Type
(iii) Range: suitable rating
Capacitor of L & T/ Bajaj/ Assian / Crompton make as per IS:2834-1986 with up to date amendments to raise the power factor at site to 0.95 for direct connections to induction motor individually of suitable capacity to HP offered including cables as per relevant ISI code ( of Siemens/Glocter/IEC make) from bus bar chamber to capacitor and also including ICTP switches of appropriate range as per IS: 4064-1978 with upto date amendments .
(i) Make
(ii) Type
(iii) Range: suitable rating
Providing star delta starter of L&T and Havells make as per IS: 8544-1979 with up to date amendments for Squirrel Cage motor mounted on panel board with magnetic type overload release and dashpot time lag, under voltage release initial oil filling with single phase preventor as per IS 8544 ( Part-II) -1987 with up to date amendments. .
Starter
i) Type starter rooter
ii) Make :
Single Phase Prevantor
Providing Hour run meter of recommended make of suitable capacity as per IS: 722 (Latest edition) 0-9999 hours .
Hour Run meter
i) Type
ii) Make
iii) Range
Providing double flanged Cast iron sluice valve of Kirloskar/ Leader make of 125 mm dia for the suction pipe and capable of with standing the normal seat pressure and as per 780-1984 ( Part-I) Class PN 1.0 with upto date ammendments ..
i) Make
(ii) Class P.N.I
(iii) Seat pressure : 10.20 Kg Cm2
iv) Material C.I.
Providing double flanged Cast stee sluice valve of Kirloskar/ Leader make one dia higher than pump for the delivery line of the pump and capable of with standing the normal seat pressure and as per relevant IS 1414 API 600 Class (ASA-150) with upto date ammendments ..
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing double flanged Cast steel reflux valve of Leader/Kirloskar make and one dia. higher than pump having bye pass arrangement on the delivery line of pump and capable of with standing normal seat pressure as per 1868 API 600 Class ASA -150 with up to date amendments
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing double flanged Cast iron non return valve of Leader/ Kirloskar make and 125 mm dia.having bye pass arrangement for rising main and capable of with standing normal seat pressure as per 1868 API 600 Class ASA -150 with up to date amendments
i) Make
(ii) Class ASA-150
(iii) Seat pressure : 21.00Kg Cm2
iv) Material :C.S..
Providing 100mm dia. circular dial pressure gauge of Fiebig make complete with all accessories such as stop cock, copper tubing etc. as per IS: 3624-1987 with up to date amendments range suitable range
(i) Make
(ii) Range :0-52 Kg/cm2
Installation of all the items appearing at Serial No. 13 to 20 as per the systematic drawing attached with the tender documents
Providing and fixing double flanged G.M.S. piping work layout to be approved by the Engineer-in-Charge for suction and delivery pipes suitable to pump(s) offered and common header as per the rising main respectively complete with all specials such as bends ,tees reducers/ increasers with companion flanges matching with the relevant specifications of the accessories as indicated in the drawing No.2 including rubber/asbestos gasket of minimum 3mm thickness as per IS 2712-1979 and required number of nuts and volts as per IS: 1364-1983. The pipes shall be as per relevant IS Code and to withstand 1.5 times total head stipulated under item No.1.
The size of the various components to be as under:-
(i) Suction pipe 125 mm dia Min. length = 15 mtr.
(ii) Delivery pipe 100 mm dia -do- = 5 mtr.
(iii) Common Header 125 mm dia -do- = 10 mtr.
(i) Suction pipe GI pipe 100 mm dia (medium class) flanged with MS flanges of table -5
(ii) Delivery pipe GI pipe 100 mm dia (Medium class) flanged with MS flanges of table -28
And will extend up to 5 meters from the outer wall of the pump house in the direction to be jointed. (iii) Common Header GI pipe 125 mm dia (Medium class) flanged with MS flanges of table -28
Providing and laying copper PVC insulated armoured power cable ( one cable carrying all the three phases) of suitable size and capacity to and all other electrical equipments as per IS: 1554 (P-I)1988 or latest with upto date amendments of Siemens/ IEC/ICC/GICO/Grandly/National make including all other accessories such as thimbles, flexible, pipes solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor.
Motor side: 16 mm2 Min length = 20 mtrs.
Supply side: 25 mm2 Min length = 10 mtrs.
Providing and fixing double loop earthing and G.I. plate /copper plate 600mmx600mmx3mm thick electrode complete with material such as thimbles, nuts and bolts, charcoal and common salt, 25mmx6mm G.I. strips & G.I. wire as per IS: 3043-1987 with up to date amendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
SANJEEV KUMAR
SS ENGINEERING WORKS
competent associates
Raman Thakur Govt. Cont.
M/S ASHWANI ELECTRICAL WAORKS
MNBN Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .