Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.7 LAccepted-AOC MIG 303 B 13 THAARINE NIVAS TNHB PHASE II NOLAMBUR CHENNAI 600 037 | THIRUVALLUR | TAMIL NADU | 600037 | L1 | Accepted-AOC The single and negotiated tenderer |
Tender Value
Refer Docs
EMD Value
₹39,600
Closing Date
30 Nov 2022, 6:00 pmClosed
SUPERINTENDING ENGINEER, NORTH CIRCLE, TNPHC LTD.,
The Superintending Engineer/North Circle No.1 and 7, Inspector quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Construction of New office building to the Tiruppur Agricultural producers co-operative marketing society at Tiruppur in Tiruppur District.
2022_TNPHC_266616_1
SE/NC/DB/4112/2022
Open Tender
Civil Works
Lump-sum
240 days
Tiruppur in Tiruppur District
Refer Tender Documents
7 documents required · 7 mandatory
₹0
₹39,600
6 Jan 2023
22 Nov 2022
2 Dec 2022
22 Nov 2022
30 Nov 2022
22 Nov 2022
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.3 : Earth work excavation in soft disintegrated (including refilling) a. 0 to 2 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
1.8 : Earth work excavation for Open Foundation in soft disintegrated rock, laterite Kankar or soft rock not requiring blasting (Excluding Refilling). b. 2 to 3 mt.
2.6: Supply and Filling of 40mm HBSJ
2.7: Supply and Filling of 20mm HBSJ
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
25 : M.S.Holdfast
31 : Weathering course
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
61.2 : Stoneware pipe dry condition a. 100mm dia
62.2 : Stoneware Tee a. 100mm dia
Electrical arrangements 69 : 15 Amp. Power plug
72 : Supply and Fixing of Box type Fibre Fan hook
73.1 : Supply and Fixing of 6 way - D.B
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
77.3 : S&F of TV/Telephone line Socket
77.4 : S&F of 20mm dia PVC pipe for TV/Telephone line
78 : Earthing Station IS3043 (Type I)
86 : Anti termite treatment
ANNEXURE 2.1.1 : Supplying and filling Gravel
2.1.3 : Supplying and Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) using Fly ash bricks of size 230x11x70mm (using crushed stone sand) with admixture
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Ground Floor
c) In First Floor.
9.2.1.1 : Brick work in C.M. 1:6 using Fly ash bricks of size 230x11x70mm (using crushed stone sand) with admixture a. In Ground Floor
b. In First Floor
10.2.1.1 : Brick partition work in C.M. 1:4 using Fly ash bricks of size 230x11x70mm (using crushed stone sand) 110 mm tk (B.P.) with admixture b. In Ground Floor
c. In First Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & basement
18.1 : Formwork using M.S.Sheet a.For Column footings,plinth beam,Grade beam,Raftbeam,Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.Vertical wall
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.5.5.1 : Supply and fixing of solid core flush door shutter os thickness 35mm b. 1000 x 2100mm
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles (antiskid) using Grout (Tile Joint Filler) (using crushed stone sand)
31.2.1 : Finshing the top of Terrace floor with one course of solar reflective Ceramic tiles with base concrete
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) with plasticizer
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
38.7 : Plastic Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1 : Rain water harvesting using defunct borewell and providing perforated cover slab (M 20) a). Providing pit
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
52.4 : 20mm dia PVC water supply ASTM pipe (fully consealed in walls)
53.5.2 : Wash Hand Basin of size 550 x 400 mm (without pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.2: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
57.1.1 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
58.5 : PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.2.1 : S & F of 20 amps DP plug & Socket in sheet enclosure with 32 A DP MCB in flush wall with earth connection(For AC Plug) superior variety
77.6 : Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.2.1 : Supplying and fixing of 3 Nos of 32Amps - Fuse unit
85.1 Supply of G.I pipe 40mm dia 'B' Class
98.3.2 : TW panelled door shutter (with brass fittings) a. 1800 x 2100mm. (Double leaf ornamental door)
112.1 Supplying and fixing Exhaust Fan 225mm dia
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.Supply and laying concrete tiles 20mm tk superior variety (using crushed stone sand)
361.5.1: Vitrified Tiles flooring (ivory) (using crushed stone sand)
367 : Providing wooden (melamine) polish for new wood
448.2: Supply and fixing 32mm dia PVC Tee with end cap
799 : Two coat of OBD over one coat white cement for inner walls
ANNEXURE II A1) Supply and erection of Rotational Moulded Polyethylene water storage tanks (HDPE Cylinderical vertical type) for outdoor use having capacity of 1000 litres
A2) Supplying and fixing of 4' long 18 Watts LED tube light with fittings
A3) Supplying and fixing of Bulk head fittings suitable for 12W bulb.
A4) Supplying and fixing of following LED Bulbs a)9 Watts LED bulbs
b) 12 Watts LED bulbs
A5) Supplying and fixing of 25" LED street light with fittings
A6) Supplying and fixing of 0.60X0.60M SFRC Manhole cover slab
A7) Supplying and applying of Full wall patty one coat with approved make wall patty for smooth finishing
A8) Supplying and fixing UPVC (Un-Plasticized PolyvinylChloride) Windows of casement type (open)
A9) Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators
A10) Manufacturing, Supplying and Fixing of Stainless Steel Handrails for staircase using 50mm dia 304L Grade Stainless Steelpipe of 1.60mm thick at required locations to a height of900mm from finished floor level
A11) Run off 4 Wires of 6 sqmm PVC insulated single core /1.1KV cable (For Three phase EB Service connection)
A12)Design, supply, testing and commissioning of floor Mounting Cubical Multi Meter Panel Board to be dust and Vermin Proof 3 phase switch board
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_316102.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .