Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Jul 2026, 6:00 pm
Similar tender results from the same govt authority in the past 3 years.
GE AF PANAGARH
GE AF PANAGARH MES AF STATION PANAGARH PO AF STATION WEST BENGAL 713155
REPAIR/ REPLACEMENT/ MAINTENANCE OF STREET/ PERIMETER /SOLAR LIGHTS AND POLES AND CONNECTED WORKS AT AFS ARJAN SINGH UNDER GE (AF) PANAGARH
2026_MES_773549_1
C/8905/E8
Open Tender
Electrical and Maintenance Works
270 days
AF STATION PANAGARH
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF PANAGARH
₹40,000
19 Jun 2026
19 Jun 2026
11 Jul 2026
19 Jun 2026
9 Jul 2026
3 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F for post top lantern LED light fitting 10 watts (Bollard) with cast aluminium spigot lid cover and clear acrylic cover with IP65 protection complete with all accessories including fixing arrangement on top surface of boundary wall or on pillar by providing GI pipe of suitable size and length as per site requirement and making good the distrubed portion to match with existing surface complete as in repair all as specified and directed.
(Make:- Havells, Cat Part No. CONEBLS8WLED830PSYMTOPC with warm light /Crompton greaves, Cat No LBLSR-10-CDL with warm light or equivalent in Philips)
(Note:- (a) LM-79 and LM-80 certificate from NABL accredited Lab shall be submitted for LED light fittings to the Engineer-In-Charge.
(b) Warranty certificate shall be submitted for LED light fitting as per standered format for minimum 50000 Hrs to the Engineer-In-Charge.
(c) LED light fitting and drivers shall be of same make.
(d) Material required for safety harness, ladder and T&P etc will be provided by the contractor without any extra cost. (e) Original purchas voucher & TC having GST No of LED light fitting complete with 1x 10 watts shall be submitted by the contractor to Engineer-in-Charge before taking any payment.) | 17 | Each Job | - | - |
| 2 | M&L for MCB, FP capacity 32 Amps to 63 Amps, 240 volts with rupturing capacity 10 KA, 'C' series including providing thimble for out going cables complete all as specified and directed. | 5 | Each | - | - |
M&L for 40mm dia street light bracket made out of galvanized iron tubing (medium grade) of 1.5mtr long with complete all fittings such as nuts & bolts, washers as required, welding and flanges etc, fixed on steel tubular pole/PCC poles including taking down of old unserviceable bracket complete all as specified and directed. | 20 | Each Job | - | - | |
M&L for 25mm dia street light bracket made out of galvanized iron tubing (medium grade) of 1.5mtr long with complete all fittings such as nuts & bolts, washers as required, welding and flanges etc, fixed on steel tubular pole/PCC poles including taking down of old unserviceable bracket complete all as specified and directed. | 5 | Each Job | - | - | |
M&L for cable junction box with IP 66 protection (halogen free and weather proof) for outdoor installations of size 260 x 210 x 116 mm with terminals including SP, MCB of 6 Amp gland for cable, FI clamp of size 20x3 mm, nuts, bolts, washers, provision of connectors for connection of cables etc complete or all including taking down as specified or directed. | 25 | Each | - | - | |
S&F for PVC insulated and PVC round sheathed, copper conductor (flexible) industrial cable 2.5 sqmm, three core 2 Run and 1.5 sqmm earthing cable in and including through GI tube of light grade of 15mm bore dia for connection of street light on pole / wall from over head conductor / junction box / DB including termination clip etc all as specified including taking down as directed by Engr-in-Charge. (Note :-Original purchase voucher of the item shall be submitted by the contractor before taking any payment duly verified and defeced by the Engr-in-Charge ) | 400 | RM | - | - | |
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 4 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete after taking down old unserviceable cable including bricks etc. all as specified and directed.
(Note :-(a) Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE. (b) Original purchase voucher of the item shall be submitted by the contractor before taking any payment duly verified and defeced by the Engr-in-Charge ) . | 300 | RM | - | - | |
S&F for flexible trailing XLPE insulated heavy duty eletric power cable with multi stranded copper conductor 1100 volts grade of size 2.5 sqmm 5 core trails alongside equipment like high mast , light cranes etc. after taking down old unserviceable cable complete. all as specified and directed. (Note :-Original purchase voucher of the item shall be submitted by the contractor before taking any payment duly verified and defeced by the Engr-in-Charge ) | 60 | RM | - | - | |
Supply,laying, jointing and testing, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 4 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete after taking down old unserviceable cable including bricks etc. all as specified and directed.
(Note :-(a) Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE. (b) Original purchase voucher of the item shall be submitted by the contractor before taking any payment duly verified and defeced by the Engr-in-Charge ) | 250 | RM | - | - | |
| 10 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in any type of soil complete all as specified and directed. | 133.7 | Cum | - | - |