| Sl No | Description | Qty | Unit | GHOSH ENTERPRISE L10 | SIMPLEX DRILLING COMPANY L4 | SINHA ENTERPRISE L8 | JOY RAM ENTERPRISE L7 | MS HORIZEN L9 | M A ENTERPRISES L3 | M/S BISWANATH BHATTACHARJEE L1 | M/s OM HINDUSTAN CONSTRUCTION PVT. LTD. L2 | MS JYOTI INDUSTRIES L5 | JOY-EN-JOY L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & fix single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed. | 56 | Each | 118 ₹6,608 | 112 ₹6,272 | 127 ₹7,112 | 120 ₹6,720 | 123 ₹6,888 | 110 ₹6,160 Lowest | 300 ₹16,800 | 160 ₹8,960 | 115 ₹6,440 | 130 ₹7,280 |
| 2.00 | Supply & fix aluminium strip 25 mm x 3 mm Complete with saddles and fixing screws for Fitting the strip complete all as specified and directed. | 1,230 | RM | 75 ₹92,250 | 70 ₹86,100 | 70 ₹86,100 | 69 ₹84,870 | 73 ₹89,790 | 62 ₹76,260 | 60 ₹73,800 Lowest | 95 ₹1,16,850 | 71 ₹87,330 | 67 ₹82,410 |
| 3.00 | Test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, etc complete all as specified and directed. | 56 | Each | 1,600 ₹89,600 | 1,612 ₹90,272 | 1,620 ₹90,720 | 1,575 ₹88,200 | 1,598 ₹89,488 | 1,568 ₹87,808 | 600 ₹33,600 Lowest | 775 ₹43,400 | 1,595 ₹89,320 | 1,605 ₹89,880 |
| 4.00 | Supply & install GI strip 25 mm x 3 mm Complete with saddles and fixing screws for fitting the strip complete all as specified and directed. | 1,230 | RM | 119 ₹1,46,370 | 112 ₹1,37,760 | 127 ₹1,56,210 | 120 ₹1,47,600 | 123 ₹1,51,290 | 106 ₹1,30,380 | 60 ₹73,800 Lowest | 125 ₹1,53,750 | 115 ₹1,41,450 | 130 ₹1,59,900 |
| 5.00 | Supply and fixing earthing of Lightning strip using 25 x 3 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm as earth electrode complete all as specified and directed. | 14 | Set of 2 Pits | 10,900 ₹1,52,600 | 10,850 ₹1,51,900 | 10,915 ₹1,52,810 | 10,650 ₹1,49,100 | 10,810 ₹1,51,340 | 9,900 ₹1,38,600 | 4,000 ₹56,000 Lowest | 12,500 ₹1,75,000 | 10,750 ₹1,50,500 | 10,725 ₹1,50,150 |
| 6.00 | Supply & Installation and testing on commissioning of Advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper Coating 250 microns. Earthing system confirming to IS:3034. The ROD should 17.2 mm & 3 Meter length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be The highly Conductive Compound as per BSEN 50164-7with 25kg each bag & resistivity should be 0.05 ohm meter. The job includes digging the pit and refilling the same by fursecem Back Fill Compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having mixed with 3:1 cement , a conductive concrete is formed. The earth pit should provided with a light weight inspection pit cover PT -205 for protection and safe guard of terminals. In areas where soil condition is bad Good earth is to be arranged to fill the excavated pits by mixing fursecem a convenient and permanent solution by adding with 3:1 ratio chemical compound with the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or collecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions. Make : ABB FurseCEM as per RB 336. Each earth pit should contain:- 1.) 1 no. copper bonded high tensile low carbon steel, 17. 2 mm dia , 3 meter length. 2.) Rod to tape clamp (type A). 3.) 25kg chemical compound as per BSEN 50164-7 4.) Light weight inspection pit cover with 5000kg weight load capacity Complete all as specified and directed by Engr-in-charge. | 2 | Each | 22,990 ₹45,980 | 22,750 ₹45,500 | 22,600 ₹45,200 | 22,100 ₹44,200 | 28,100 ₹56,200 | 19,800 ₹39,600 Lowest | 25,000 ₹50,000 | 31,000 ₹62,000 | 22,230 ₹44,460 | 22,390 ₹44,780 |
| 7.00 | Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed. | 420 | Point | 48 ₹20,160 | 50 ₹21,000 | 48 ₹20,160 | 41 ₹17,220 | 46 ₹19,320 | 40 ₹16,800 | 20 ₹8,400 Lowest | 100 ₹42,000 | 41 ₹17,220 | 45 ₹18,900 |
| 8.00 | Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting modular type switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
(NOTES: -
(i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same.
(ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
(a) One light point or one fan point controlled by one switch | 112 | Point | 1,185 ₹1,32,720 | 1,160 ₹1,29,920 | 1,179 ₹1,32,048 | 1,163 ₹1,30,256 | 1,176 ₹1,31,712 | 1,150 ₹1,28,800 | 1,000 ₹1,12,000 Lowest | 1,100 ₹1,23,200 | 1,165 ₹1,30,480 | 1,161 ₹1,30,032 |
| 9.00 | All as per item No 8 above but using one 3/5 pin socket outlet, 5 Amp independent | 144 | Point | 1,185 ₹1,70,640 | 1,160 ₹1,67,040 | 1,179 ₹1,69,776 | 1,163 ₹1,67,472 | 1,176 ₹1,69,344 | 1,150 ₹1,65,600 | 1,000 ₹1,44,000 Lowest | 1,210 ₹1,74,240 | 1,165 ₹1,67,760 | 1,161 ₹1,67,184 |
| 10.00 | All as per item No 8 above but using one 3/5 pin socket outlet, 5 Amp on the same board with other switches | 72 | Point | 128 ₹9,216 | 140 ₹10,080 | 127 ₹9,144 | 125 ₹9,000 Lowest | 138 ₹9,936 | 130 ₹9,360 | 250 ₹18,000 | 325 ₹23,400 | 132 ₹9,504 | 135 ₹9,720 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
18 Jun 2026, 6:00 pmClosed
Garrison Engineer (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR/REPLACEMENT OF INTERNAL AND EXTERNAL ELECTRIFICATION OF BLDG NO O-11 AND O-14 INSIDE VIJAY DURG UNDER GE(VD) KOLKATA
2026_MES_759021_4
8562/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (FW) Kolkata
AS PER NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer (FW) Kolkata
₹74,000
18 Aug 2026
6 Jun 2026
19 Jun 2026
6 Jun 2026
18 Jun 2026
13 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & fix single pointed air termination Aluminium rod, 12 mm dia, 300 mm long complete all as specified and directed. | 56 | Each | - | - |
| 2 | Supply & fix aluminium strip 25 mm x 3 mm Complete with saddles and fixing screws for Fitting the strip complete all as specified and directed. | 1,230 | RM | - | - |
| 3 | Test point terminal box of size 200 x 100 x 100 mm made out of 2 mm thick hot dip galvanised sheet drilled and screwed including 6 Nos 15 mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosphorus Bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws, etc complete all as specified and directed. | 56 | Each | - | - |
| 4 | Supply & install GI strip 25 mm x 3 mm Complete with saddles and fixing screws for fitting the strip complete all as specified and directed. | 1,230 | RM | - | - |
| 5 | Supply and fixing earthing of Lightning strip using 25 x 3 mm galvanized MS strip and MS galvanized plate of size 600 x 600 x 6 mm as earth electrode complete all as specified and directed. | 14 | Set of 2 Pits | - | - |
| 6 | Supply & Installation and testing on commissioning of Advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper Coating 250 microns. Earthing system confirming to IS:3034. The ROD should 17.2 mm & 3 Meter length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be The highly Conductive Compound as per BSEN 50164-7with 25kg each bag & resistivity should be 0.05 ohm meter. The job includes digging the pit and refilling the same by fursecem Back Fill Compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having mixed with 3:1 cement , a conductive concrete is formed. The earth pit should provided with a light weight inspection pit cover PT -205 for protection and safe guard of terminals. In areas where soil condition is bad Good earth is to be arranged to fill the excavated pits by mixing fursecem a convenient and permanent solution by adding with 3:1 ratio chemical compound with the earth electrode is the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or collecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions. Make : ABB FurseCEM as per RB 336. Each earth pit should contain:- 1.) 1 no. copper bonded high tensile low carbon steel, 17. 2 mm dia , 3 meter length. 2.) Rod to tape clamp (type A). 3.) 25kg chemical compound as per BSEN 50164-7 4.) Light weight inspection pit cover with 5000kg weight load capacity Complete all as specified and directed by Engr-in-charge. | 2 | Each | - | - |
| 7 | Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants , regulators, sockets etc excluding light fitting for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and directed. | - | Point | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_862692.xls
BOQ • 2.74 MB
TENDERDOCUMENTS8562.pdf
Tender Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .