Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹52.5 L+₹2.5 L (5.00%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹54.0 L+₹4.0 L (7.97%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Ashok Kumar Upadhya L2 | GAUTAM ENTERPRISES L3 | Aien Meren Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00TRANSFORMER REPAIR AND LT LINE WORK | ||||||
| 1.01 | Taking out the sample of transformer oil from each transformer at various locations for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc after the dehydration including de-hydration (Filtration) of transformer oil through mobile filtration plant to be used to respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed for transformer . The item inclusive of Transportation of mobile filtration upto work site and testing will be carried out after dehydration and exclusive of oil topping. Oil topping of required quantity will be paid spearately on measurements as per schedule this work. | 3,200 | Ltrs | 162.75 ₹5,20,800 | 167 ₹5,34,400 | 155 ₹4,96,000 Lowest |
| 1.02 | Replacement of bushing insulator (male and female with gasket ) complete set as per sample for 200/250 KVA transformer | 4 | Nos | 1,575 ₹6,300 | 1,620 ₹6,480 | 1,500 ₹6,000 Lowest |
| 1.03 | Replacement of bushing insulator (male and female with gasket ) complete set as per sample for 500 KVA transformer | 8 | Nos | 1,260 ₹10,080 | 1,296 ₹10,368 | 1,200 ₹9,600 Lowest |
| 1.04 | Removing the existing oil stains by point removers and cleaning with scrapers, preparing the old transformers surfaces including subsequent coat of synthetic enamel paint of approved colour with one coat of red oxide zinchrome primer of the surface of the transformer of capacity 200 KVA by spray gun all as specified and directed at site. | 2 | Nos | 5,250 ₹10,500 | 5,400 ₹10,800 | 5,000 ₹10,000 Lowest |
| 1.05 | Removing the existing oil stains by point removers and cleaning with scrapers, preparing the old transformers surfaces including subsequent coat of synthetic enamel paint of approved colour with one coat of red oxide zinchrome primer of the surface of the transformer of capacity 500 KVA by spray gun all as specified and directed at site. | 4 | Nos | 7,875 ₹31,500 | 8,100 ₹32,400 | 7,500 ₹30,000 Lowest |
| 1.06 | Taking down old UNSV gasket by removing not bolt system from main body of the transformer including replacment of entire gasket complete of cpacity upto 500 KVA all as all as psecified and directed at site. | 4 | Job | 4,725 ₹18,900 | 4,860 ₹19,440 | 4,500 ₹18,000 Lowest |
| 1.07 | Supply and fix LT OH lines on existing Steel /PCC poles with Continuous GI earth wire incl earthing of poles cross arms, insulators etc size 3 of 6/1 x 2.59 mm (Weasel),1 of 6/1 x 2.11mm (Squirrel) (Sect HQ Camp area) | 350 | Mtr | 138.6 ₹48,510 | 142 ₹49,700 | 132 ₹46,200 Lowest |
| 1.08 | Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 1.5 Ton capacity Split type AC. | 10 | Job | 3,811.5 ₹38,115 | 3,920 ₹39,200 | 3,630 ₹36,300 Lowest |
| 1.09 | Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 2 Ton capacity Split type AC. | 10 | Job | 4,137 ₹41,370 | 4,255 ₹42,550 | 3,940 ₹39,400 Lowest |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
1 Sept 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SOIWorks
Kashiram Basti
6 Sect/Engr/MW/2025-26/177
2025_ARMHA_873639_1
6 Sect/Engr/MW/2025-26/177
Open Tender
Electrical Works
Item Rate
270 days
Kashirambasti
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
DGAR
₹1 L
24 Sept 2025
18 Aug 2025
2 Sept 2025
18 Aug 2025
1 Sept 2025
18 Aug 2025
18 Aug 2025 - 18 Aug 2025
Amount
TRANSFORMER REPAIR AND LT LINE WORK
Taking out the sample of transformer oil from each transformer at various locations for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc after the dehydration including de-hydration (Filtration) of transformer oil through mobile filtration plant to be used to respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed for transformer . The item inclusive of Transportation of mobile filtration upto work site and testing will be carried out after dehydration and exclusive of oil topping. Oil topping of required quantity will be paid spearately on measurements as per schedule this work.
Replacement of bushing insulator (male and female with gasket ) complete set as per sample for 200/250 KVA transformer
Replacement of bushing insulator (male and female with gasket ) complete set as per sample for 500 KVA transformer
Removing the existing oil stains by point removers and cleaning with scrapers, preparing the old transformers surfaces including subsequent coat of synthetic enamel paint of approved colour with one coat of red oxide zinchrome primer of the surface of the transformer of capacity 200 KVA by spray gun all as specified and directed at site.
Removing the existing oil stains by point removers and cleaning with scrapers, preparing the old transformers surfaces including subsequent coat of synthetic enamel paint of approved colour with one coat of red oxide zinchrome primer of the surface of the transformer of capacity 500 KVA by spray gun all as specified and directed at site.
Taking down old UNSV gasket by removing not bolt system from main body of the transformer including replacment of entire gasket complete of cpacity upto 500 KVA all as all as psecified and directed at site.
Supply and fix LT OH lines on existing Steel /PCC poles with Continuous GI earth wire incl earthing of poles cross arms, insulators etc size 3 of 6/1 x 2.59 mm (Weasel),1 of 6/1 x 2.11mm (Squirrel) (Sect HQ Camp area)
Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 1.5 Ton capacity Split type AC.
Dismantling, Taking down carefully from the installed position and re installing in its original position and testing on completion of proper servicing complete all as directed by the Engineer – in – Charge of 2 Ton capacity Split type AC.
M & L for Gas refilling and charging of R-22 refrigerant to the 1.50 Ton capacity Split type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R- 32 refrigerant to the 1.5 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R-32 refrigerant to the 1.5 Ton capacity Window Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
M & L for Gas refilling and charging of R- 32 refrigerant to the 2 ton capacity Split Type AC, including testing of leak the complete system as specified and as per direction of Engineer - in - Charge.
Servicing only Split type air conditioners of 1.5/2.00 Ton capacity by cleaning of out door/indoor units,Removal of dust, dirtand debris from filters,coils and fins, Checking and cleaning of drainage pipes.,Checking of thermostat functionalityand checking of refrigrant pressure levels etc complete.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 2 Ton capacity Split type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 2 Ton capacity Split type AC (Inverter type) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable main PCB/display PCB and Supply and fixing New main PCB/display PCB suitable for existing model for 1.5 Ton capacity Window Type AC (Display PCB) AC complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5 Ton capacity Split type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 2 Ton capacity Split type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Disconnect and repair of main PCB/display PCB and re fixing of repaired main PCB/display PCB suitable for 1.5 Ton capacity Window Type AC (Display PCB) complete all as specified and as per direction of Engineer – in – Charge
Installation only Air conidtioner unit of 1.5/2 Ton cacpaicty includes mou nting of indoor unit,installation of out door unit, refrigerant piping and insulation, drain line work and commissioning and testing of entire unit complete.The cost inclusive of 4 mtr copper pipe of 1/2,3/4 " size complete.
Taking out the burnt fan motor from the 1.50 Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking out the burnt fan motor from the 2 Ton capacity Split type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking out the burnt fan motor from the 1.50 Ton capacity Window Type AC and supply and fixing new fan motor suitable for existing model complete all as specified and as per direction of Engineer – in – Charge
Taking down unserviceable blower motor (for Indoor unit) of 1.50 Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable blower motor (for Indoor unit) of 2 Ton capacity Split type AC and supply and fixing new blower motor suitable for existing model of indoor unit of split type AC, including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable swing motor of 1.5 ton/2 ton capacities split type AC and supply and fixing new swing motor suitable for existing model of indoor unit of split type AC including necessary connections and testing on completion complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (50/55 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge.
Taking down unserviceable capacitor from Split type/Window type AC and supply and fixing New Capacitor (60 MFD) , including testing on completion etc complete all as specified and as per direction of Engineer – in – Charge.
Disconnect and remove unserviceable 1.50 Ton capacity Split type AC compressor and Supply and fixing of new rotary/reciprocating compressor including brazing the suction/discharge lines suitable for existing model following capacity ACs and testing on all as specified and as per direction of Engineer – in – Charge
Supply and fixing on Wall MS factory made pre painted bracket for Out door Unit fixed with Nut bolt/ Screw.
Supply and fixing of copper gas pipe ½” nominal bore
Supply and fixing of copper liquid pipe ¼ ” nominal bore
Providing and fixing of PVC fliexble pipe with connected accessories of 15 mm dia /as per site requirement for external
Supply and fix Aflex-Eco Nitrile rubber pipes for insulation of AC copper pipe for insulation ( dia 6/9/13/19/25 mm) with approved thickness all as per site requirement
Servicing/overhauling monoblock pump set of capacity 3HP, 3 Phase, 2880 RPM including carrying out maintenance check along with following repairs: (a) Dismantling of monoblock motor pump set and display all the parts without Servicing/overhauling monoblock pump set of capacity 3HP, 3 phase , 2880 RPM including carrying out maintenance check along with following repairs: (a) Dismantling of monoblock motor pump set and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts. (b) Repair/ replacement of bearing and greasing. (c) Repairs play of impeller and greasing. (d) Assembling motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (e) Installation of motor by making connection as per existing and testing on load.
ditto but 5 HP capacity (Sect HQ)
ditto but 10 HP capacity (Sect HQ)
Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motor pump set of capacity 3 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ)
Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motor pump set of capacity 5 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ)
Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motor pump set of capacity 10 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ)
Rewinding, Heat Varnishing, Installation, Testing and Commissioning of Centrifugal monoblock motor pump set of capacity 20 HP, working on 3 Phase, 440 volts with bare copper winding of appropriate gauge and as per direction of engineer-in- charge. (Sect HQ)
Supply and fixing in replacement motor starter 415V, 50Hz ,phase suitable for motor capacity 5HP relay range 6-10 amps having essential motor protection against over loding single phasing phase sequence reversal abnormality in supply unbalanced current complete all as specified and direct MAKE:- L&T cat no MU-GDOL or equivalent in Simens havells.
M & L for opening the existing Iron Vessels of Iron Remover Plant 3000 LPH ( Size- 24'' dia x 60'' height ) including replacement of existing old Catalytic Oxidizing filter media of various sizes including Anthracite and treated filter sand , unserviceable strainers etc complete and deposited to place where directed by Engineer - in - Charge :- (a) Supply and fixing rubber gasket joint for all packing required places of IRP unit - 01 Job (b) External synthetic enamel pinting etc complete. (Sect HQ, Kashiram Basti)
M & L for opening the existing Iron Vessels of Iron Remover Plant 5000 GPH including replacement of existing old Catalytic Oxidizing filter media of various sizes including Anthracite and treated filter sand , unserviceable strainers etc complete and deposited to place where directed by Engineer - in - Charge :- (a) Supply and fixing rubber gasket joint for all packing required places of IRP unit - 01 Job (b) Supply and fixing diaphragm valves of size 80 mm dia -04 Nos (c) Supply and fixing water pressure gauge duly calibrated of existing size complete 01 Job all as specified and directed. (d) External synthetic enamel pinting etc complete. (d) Replacment of plastic push type strainers of approved qulaityand size whereever required. (e) Replacment of existing MNO2 lumps or antracite lumps for oxidising agents for existing oxidation chamber (f) Internal vessels painted with food grade paint.
Replacement of 4040 membranes for 500 LPH RO plant including cleaning and minor repair of CPVC pipe line etc complete.
Servicing of 1000 LPH RO plant including replacement of 20" Big Blue Cartridge.
Replacement of 8040 membranes for 1000 LPH RO plant including cleaning and minor repair of CPVC pipe line etc complete.
Supply and fill on replacment of carbo fill for 1000 LPH RO plant (for acivated carbon filter). Granular activated carbon(CAG) with Iodine member of 900mg/gall as per site requirement and as per direction of Engr-In-Charge.
Supply and fill on replacment of carbo fill for 500 LPH RO plant (for acivated carbon filter). Granular activated carbon(CAG) with Iodine member of 900mg/gall as per site requirement and as per direction of Engr-In-Charge.
Supply and filling antiscalent of approved quality.
Servicing of RO Plant including cleaning and maintenance of RO membrane, Roto meters, Filter catridges complete all as specified as per site requirement complete.
Supply and fixing of fan capacitor of 2.5 MFD capacity (Make: EPCOS/Havells/Concap)
Supply and fixing 2 core copper flexible wires of size 7/20 of approved quality (Sect HQ)
Supply and PVC Casing caping of 25 mm dia including replacment of existing PVC condutis of wiring complete
Supplying and fixing call bell/ buzzer/Ding Dong/ Required musical souds suitable for single phase, 230 V, complete as required.
Supplying and fixing 25 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure or motor starter , on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required for AC connections complete.
Servicing only 30/35 KVA DG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment.
Servicing only 62.5 KVA DG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment.
Servicing only 125 KVA DG set complete including replacement of Fuel filter element -01 Nos, Oil Filter element -01 Nos, Air filter element -01 Nos, Coolant- 05 Ltrs , Engine oil- 12 ltrs and Engine tapet servicesincluding Banjo washers etc complete as per site requierment.
Supply, Installation Testing and Commissioning of 30 HP centrifugal pumping set on existing foundation 3 phase, with Suction and delivery size 100mm x80mm with discharge capacity of 20 LPS on 60 Mtr Head with provding 30 HP capcity with necessary connection by using 16 Sqmm Copper conductor cable and testing all as per ground requirement/ as per direction of Engr-In- Charge. The cost inclusive of one year warrnaty maintenance excluding spares.
Supply and fixing automaitc change over switch 63 Amps, 240 Volts ac suitable to mount on existing circuit including necessary connection and teting all as specified and directed at site.
Material & Labour for overhauling of 35 KVA Genr set (Canopy Type) Model No.4575M, Engine Ser No.V4H10T2970, of Make- Mahindra by taking out all unserviceable spares parts, cleaning by brushing to remove dust including replancing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts. Cost of dismantling work and Site Inspection charges including the scope of work:-
(a) Head Gasket
(b) Chamber Gasket
(c) Tapet Gasket
(d) Valve Oil Seal
(e) Engine Oil
(f) Coolant
(g) Valve Intake
(h) Valve exhaust
(j) Valve seat and Intake & Exhaust
(k) Vlave Guide
(l) Piston
(m) Piston Pin
(n) Piston Ring
(o) Liner
(p) Liner O Ring
(r) CR Bearing
(t) Thermostat
(u) Dyanamo Belt
(w) Fan Belt
(x) Temparature Switch
(y) Hose pipe
(z) Oil filter
(aa) Air filter
(ab) Fuel filter
(af) Radiator servicing
(ag) Water pump assembly
(ac) Cylinder head seat fitting, cutting & valve guide setting
(ad) Nozzle pump repairing work
(ae) Head repairing work
(af) FIP Nozzle testing & servicing
Material & Labour for overhauling of 30 KVA Genr set Model No. HA 494 T, Engine. Ser No. 04.2121/0920036 Make- KOEL by taking out all unserviceable spares parts, cleaning by brushing to remove dust including replancing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts.
(a) Valve
(b) Valve Guard
(c) Valve Seal
(d) Valve Oil Seal
(d) Linear
(e) Piston
(f) Piston ring
(g) Engine Oil
(h) Lub Oil Filter
(j) Main Bearing
(k) C.R Bearing
(l) Thrus Washer
(m) Oil Seal
(n) Connecting Rod
(o) O' ring Kit
(p) Push rod O ring
(q) Oil Pump
(r) Head Assembly
(s) Head Gasket
(t) Connecting shaft assy
(u) Dynamo Ring
(v) FIP pump repairing & nozzle injector
(w) Self assembly
(x) Diesel filter
(y) Diesel pipe
(z) Set of joint
(aa) Annerbend
(ab) Oil cooler assembly
(ac) Oil cooler 'O' Ring
(ad) Nozzle Guttka
(ae) Head lathe machine charge
Material & Labour for overhauling of 35 KVA Genr set (Canopy Type) Model No.4575M, Engine Ser No.V4H10T3481, of Make- Mahindra ( Genr Room , MT Sect HQ) by taking out all unserviceable spares parts, cleaning by brushing to remove dust including replacing of diesel filters, lub oil filters, checking of all nuts, bolts tightening wherever necy, draining out old engine oil and coolant and filing new engine oil and coolants required at site. Adjustment and replacement of fan belt, tuning of engine, adjustment of speed, alternator voltage, frequecny etc , greasing, oiling and checking for smooth running of DG set including following spare parts. Cost of dismantling work and Site Inspection charges including the scope of work:-
(a) Head Gasket
(b) Chamber Gasket
(c) Tapet Gasket
(d) Valve Oil Seal
(e) Engine Oil
(f) Coolant
(g) Valve Intake
(h) Valve exhaust
(j) Valve seat and Intake & Exhaust
(k) Vlave Guide
(l) Piston
(m) Piston Pin
(n) Piston Ring
(o) Liner
(p) Liner O Ring
(r) CR Bearing
(t) Thermostat
(u) Dyanamo Belt
(w) Fan Belt
(x) Temparature Switch
(y) Hose pipe
(z) Oil filter
(aa) Air filter
(ab) Fuel filter
(af) Radiator servicing
(ag) Water pump assembly
(ac) Cylinder head seat fitting, cutting & valve guide setting
(ad) Nozzle pump repairing work
(ae) Head repairing work
(af) FIP Nozzle testing & servicing
M/L for dismantling of Alternator and taking into wksp for rewinding of the same by suitable gauge of copper conductor and varnishing etc including testing in various loads all as specified including refitting of alternator and as per site. One year warrnaty will be provided for rewinded alternator to Department on completion of work.The cost inclusive of rotor repair works and alignment setting complete. Dismatled UNSV copper material will be the property of contractor
Supply and fixing AVR Card complete for Model No.4575M, Engine Ser No.V4H10T3481, of Make- Mahindra and testing complete.
Supply, Insallation of 01 HP monoblock centrifugal feeder pump (Slow speed) including all connected items ie. Starter, wiring connection and dismantling of old pumping set all as per sitre requirement complete for pump house filtration system.
Supply, Installation and testing and commissioning of Electronic dosing system suitable for 3000 LPH IRP including 100 ltr dosing tank and connected works as per site requirement for Alum and chemical dosing complete.
Supply only Sodium bi carbonate
Supply only liquid chlorine ( 50 ltr container)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge of 40 mm dia
Making connection of G.I/CPVC . distribution branch with G.I./CPVC main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete of 40 mm dia.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (cost of repairworks of wall and painting works in patches including making good to the surfaces to match on the existing surfaces.
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way piano type switch,phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loopearthing as required.
Wiring for circuit/ sub main wiring along earth wire with the 2x6 sq mm+1x6 sq mm earth wire of FRPVC insulated copper conductor, single core cable in PVC conduit as required.
Wiring for circuit/ sub main wiring along earth wire with the 2x2.5 sq mm+1x2.5 sq mm earth wire of FRPVC insulated copper conductor, single core cable in PVC conduit as required.
Supplying and fixing following modules switch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required. (a) 5/6 amps socket out let
Supplying and fixing following modules switch/ socket on the existing modules plate & switch box including connections but excluding modules plate etc as required of 15/16 amp switch
Supply and fixing of 5 pin15/ 16 amp socket outlet
Supply and fixing of Telephone socket outlet/TV Antenna
Supplying and fixing two modulestepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc.as required.1 or 2 Module (75mmX75mm)
Supply and fixing of 3 Module (100mmX75mm)
Supply and fixing of 6 Module (200mm X75mm)
Supply and fixing of 8 Module (125mm X125mm)
Supply and fixing of 12 Module (200mm X 150mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required 1 or 2 Module
Supply and fixing of 3 Module
Supply and fixing of 6 Module
Supply and fixing of 8 Module
Supply and fixing of 12 Module
Supply and fixing of calling bell(Ding-dong), single phase, 230 Volt AC of approved quality as per site requirement.
Supply and fixing of single phase motor switch for AC (25Amps) of approved brand as per site requirment (Make: Legrand/Havells) ( including necessary civil works for fixing semi concealed)
Supply and fixing of mirror light 12 Watt, three colour provision/ as of approved by user (Make : Philips/ Havells)
Supply and fix wall bracket fitting of apporved quality with bulb and accessories complete as approved by user
Supply & fix exhaust fans (Slim Air PVC) AC single phase 230/ 240 V of size 300 mm sweep with louver,
Supply and fix Ceiling surface type Grid light of 200 mm dia with 18 watts,3000k of approved quality (Make : Philips)
Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc of 6 way SPN with2x double pole MCB 63 Amps and 2x40 Amps including providing blanking palte for 2 way complete
Supply, Installation, testing and commissioning of LED batten of 18 watts,3000K and connections with1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required (Make: Havells/Bajaj)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required of size 35 Sqmm to 95 Sqmm Size.The specification of laying cable is confirming to IS -1255.1983 and as per direction of Engr-In Charge. (Genr line from Genr Room to JCO Club and Main line from Main Pole to JCO line). Providng cable connection to end point by using suitable size of cable lugs all as specified and directed at site. (Sect HQ)
Supply, Installation, testing and commisioning of LT Cubical feeder pillar box made of 2 mm thick CRCA Sheet, horizontal and vertica busbar rated 400 Amps copper 25x10 for phase and 200 A25x5 mm for neutral , RAL - 7032 (70 micron) Partially type tested as per IEC 60439, outdoor IP-53 of size 1200 mm (H) (incl 300 mm base x 400 mm width 300 mm (D) with front cable ally and cable entry bottom/top including PCC for cement concrete all as specified and directed by E-I-C.(Sect HQ)
M/s Ashok Kumar Upadhya (BID ID -3272621)
GAUTAM ENTERPRISES (BID ID -3273435)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .