| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹3.3 Cr+₹15.3 L (4.87%)Rejected-Finance | ₹3.3 Cr+₹15.3 L (4.87%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.7 Cr+₹50.9 L (16.2%)Rejected-Finance | ₹3.7 Cr+₹50.9 L (16.2%) | L3 | Rejected-Finance L3 |
| 4 | L4₹7.9 Cr+₹4.7 Cr (151.2%)Rejected-Finance | ₹7.9 Cr+₹4.7 Cr (151.2%) | L4 | Rejected-Finance L4 |
Tender Value
₹3.8 Cr
EMD Value
₹4.5 L
Closing Date
12 Aug 2023, 6:00 pmClosed
HQ Cheif Engineer Jalandhar Zone Jalandhar Cantt
HQ Cheif Engineer Jalandhar Zone Jalandhar Cantt
ADDN/ALTN OF SEWAGE NETWORK SYSTEM AT AMRITSAR CANTT
2023_MES_595422_1
81050/E8
Open Tender
Civil Works
Lump-sum
365 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer Amritsar Cantt
₹4.5 L
Yes
29 Aug 2023
6 Jun 2023
21 Aug 2023
6 Jun 2023
12 Aug 2023
29 Jul 2023
Amount
Note : Please refer Schedule 'A' Notes given on serial page No. 20, 21, 22(R), 23 of tender documents.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 24.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 25(R).
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 27(R).
Lump sum price worked out by the contractor for ROAD, PATH & HARDSTANDING WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 28(R).
Lump sum price worked out by the contractor for SECURITY WALL, FENCING AND GATE WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 30(R).
Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 31(R).
EXTERNAL ELECTRIFICATION WORKS
Supply, laying in trenches DWC pipe 75mm dia ISI marked suitable for LT cable proptection all as specified and directed by Engineer-in-Charge.
Material and labour for road cutting by excavation with width of 0.5 mtr and redressing of surfaces after the completion of the work complete all as specified and directed.
Supply install testing and commissioing of chlorine Dosing system with Non-metallic solution tank of 100 ltrs capacity with motor driven agitator to maintain uniform suspension through out the tank, electrically operated, chlorine dosing tank of 100 ltrs capacity of PE/FRP MOC with PE/FRP lid & level gauge along with single phase electric motor and agitator, 120 watts, 960 RPM, 230 Volts, 50 Hz, and having speed controller to reduce speed upto 800 RPM, with shaft & blade in plastic, mounted on tank. Lid must have port hole for pouring calcium hypochlorite and water when necessary. Lid must have provision for mounting dosing pump on the lid/wall including high pressure single head gear motored adjustable Dosing Pump set, uneffected on dry running having no loss of prime, independent of back pressure and able to handle both chemical solutions as well as suspension, 230 volts, 50 Hz, AC, 44 RPM, 1/30 fraction HP having output 2US GPD to 40 US GPD complete with accessories i.e. lead tubing, connecting nuts, injection check valve, clay weight and ferrules including complete installation all as specified and directed by Engr-in-Charge.
Supply, Install, testing and commissioning LT Distribution Panel (CPRI approved) cubicle type IP-54, indoor type factory fabricated pre-wired made out of 2mm thick with CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at botom of MS chanel MC 100 fixed to the top of platform duly grouted with PCC with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :-
Incomer of LT Panel :- (i) Aluminium TPN bus bar strip of rating 600 Amps fixed on epoxy insulator -04 No. (ii) MCCB 4 pole 400A,36 A alongwith spreader terminal with adjustable thermal magnetic setting-02 (Nos DG+main supply). (iii) Change over on load open execution -400 Amps,415 V, 50 Hz, 4 pole-01 No (iv) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (v) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set Outgoing of LT Panel:- (i) MCCB 200 Amps , 4 P,36 KA 415V,50 Hz with thermal magnteic setting-03 Nos (ii) MCCB 63 Amps 4 pole,16 KA, 415V,50 Hz with thermal magnteic setting -01 Nos (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos. (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set( for each outgoing) Notes : (i) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE. (ii) SLD diagram for LT panel will be approved from GE before placing the order and final diagram will be fixed on front and rear door
Supply, Install, testing and commissioning LT Distribution Panel (CPRI approved) cubicle type IP-65, Outdoor type conforming to IS-5039 of 1983, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class 'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :-
Incomer of LT Panel :- (i) Aluminium TPN bus bar strip of rating 300 Amps fixed on epoxy insulator -04 No. (ii) MCCB 4 pole 200A, 36 A alongwith spreader terminal with adjustable thermal magnetic setting-01 (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set Outgoing of LT Panel:- (i) MCCB 63 Amps 4 pole,36 KA, 415V,50 Hz with thermal magnteic setting -04 Nos (ii) MCCB 10 to 40 Amps 4 pole,16 KA, 415V,50 Hz with thermal magnteic setting -11 Nos (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 No (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set (v) DOL starter suitable for 3 Phase motor 5 HP capacity-04 Nos (vi) Star delta starter suitable for 3 Phase motor 10 HP capacity-05 Nos (vii) Star delta starter suitable for 3 Phase motor 7.5 HP capacity-02 Nos (viii) Star delta starter suitable for 3 Phase motor 20 HP capacity-02 Nos (ix) Star delta starter suitable for 3 Phase motor 40 HP capacity-02 Nos (x) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (xi) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set( for each outgoing) Notes : (i) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE. (ii) SLD diagram for LT panel will be approved from GE before placing the order and final diagram will be fixed on front and rear door
Supply, Install, testing and commissioning LT Distribution Panel (CPRI approved) cubicle type IP-65, Outdoor type conforming to IS-5039 of 1983, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class 'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :-
Incomer of LT Panel :- (i) Aluminium TPN bus bar strip of rating 300 Amps fixed on epoxy insulator -04 No. (ii) MCCB 4 pole 200A, 36 A alongwith spreader terminal with adjustable thermal magnetic setting-01 (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set Outgoing of LT Panel:- (i) MCCB 63 Amps 4 pole,36 KA, 415V,50 Hz with thermal magnteic setting -02 Nos (ii) MCCB 10 to 40 Amps 4 pole,16 KA, 415V,50 Hz with thermal magnteic setting -08 Nos (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set (for each outgoing) (v) DOL starter suitable for 3 Phase motor 5 HP capacity-04 Nos (vi) Star delta starter suitable for 3 Phase motor 10 HP capacity-04 Nos (vii) Star delta starter suitable for 3 Phase motor 40 HP capacity-02 Nos Notes : (i) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE. (ii) SLD diagram for LT panel will be approved from GE before placing the order and final diagram will be fixed on front and rear door
Supply, Install, testing and commissioning LT Distribution Panel (CPRI approved) cubicle type IP-65, Outdoor type conforming to-5039 of 1983, factory fabricated pre-wired made out of 3.15mm thick CRCA MS sheet outer & 2mm thick CRCA sheet inner of suitable size to accommodate all accessories / fittings compartmentalized in construction to accommodate the incoming MCCB and TPN bus bars and outgoing feeders . The TPN bus bars shall be insulated with colour coated heat shringable sleeve and shall be mounted on DMC support . The incoming as well as outgoing MCCBs shall have extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC support having provision for termination of incoming and outgoing cables. All extension links/ interconnections hsall colour coated sleeves. The cubical shall have frame work at bottom of MS channel MC 100 fixed to the top of platform. The platform for LT panel shall be pedestal type of suitable width and 600mm height above ground level and minimum 400mm below ground level constructed with brick (sub class 'B') work duly plastered in CM 1:3 and PCC coping (1:2:4) not less than 50cm thick over bricks padestal with adequate opening for entry of cable complete as per manufacturers recommendation & directed by Engineer-in-Charge . A detacheable gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size compression glands, the panel shall be painting with powder coated finish with RAL 7032 SIEMENS GRAY Structure after seven tank phosphating treatment , front & back opening type, and fixing 2 Nos danger notice plate to LT Panel with voltage and danger indicated in Hindi and English with double door shutter and shall have lourvers and airvent gasket for natural flow of air Neoprene adhesive type gasket shall be used to make panel vermin proof and comprising of following :-
Incomer of LT Panel :- (i) Aluminium TPN bus bar strip of rating 200 Amps fixed on epoxy insulator -04 No. (ii) MCCB 4pole 63A, 25 A alongwith spreader terminal with adjustable thermal magnetic setting-01 (iii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (iv) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set Outgoing of LT Panel:- (i) MCCB 10 to 40 Amps 4 pole,16 KA, 415V,50 Hz with thermal magnteic setting -03 Nos (ii) Multifunction digital meter to measure voltage, current,KWH,PF,Amp with CT's set with suitable size.-01 Nos (iii) Indicating Lamp LED type 240 Volts AC set of three colour (RYB)-01 set (for each outgoing) (iv) Star delta starter suitable for 3 Phase motor 10 HP capacity-01 Nos (v) Star delta starter suitable for 3 Phase motor 20 HP capacity-02 Nos Notes for Srl item No. 3.04 to 3.07 : (i) LT panel board shall be type tested from CPRI for 4000 Amps with breaking capacity not less than 65 KA and IP 56 as per IS-61439 Part I & II (copy of valid CPRI type test report to be enclosed while obtaining approval of GE. (ii) SLD Diagram for LT Panel will be got aproved from GE before placing the order and final diagram will be fixed on the front and rear door. (iii) Rate for above factors shall be deemed to be including in rate quoted. Notes : (i) A copy of valid CPRI type test report to be enclosed while obtaining approval of GE. (ii) SLD diagram for LT panel will be approved from GE before placing the order and final diagram will be fixed on front and rear door
Supply, installation, testing and commissioning of Ultra sonic non-contact sensor for level monitoring & level based operation of pump for sewage sump with suitable powers supply and necessary cabling arrangement complete as per given specification :- Principal : Ultra sonic sound waves water level sensing. Range : 0-6 mtrs. Output : 4-20 mA Accuracy : +-0.25 % of full scale or better. Enclosure : IP-65 weather proof. Make : SBEB/Electronet/PuneTechtrol/waree/Seimens/Forbes Marshal.
Supply, installation, testing and commissioning of Ultra sonic non-contact sensor for level monitoring & level based operation of pump for sewage sump with suitable powers supply and necessary cabling arrangement complete as per given specification :- Principal : Ultra sonic sound waves water level sensing. Range : 0-10 mtrs. Output : 4-20 mA. Accuracy : +-0.25 % of full scale or better. Enclosure : IP-65 weather proof. Make : SBEB/Electronet/PuneTechtrol/waree/Seimens/Forbes Marshal.
Supply, installation, testing and commissioing of Online effluent monitoring system for online measurement of pH, TSS, BOD, COD including display terminal along with required signal cables, power cables, PVC piping, means for local data acquisition, display of data on continuous basis including necessary fixing arrangement cutting/drilling holes to existing MS/DI/CI pipes any size for fixing of analyser and making good the disturbed surfaces copmlete all as directed by Engg-in-Charge and comprising of following:- Method: COD,BOD,TSS & pH , UV-light absorption method, pH: Electrochemical method. Calibration:- zero calibration: an auto zero is performed at every cleaning cycle. Span: Factory calibrated. Operation cycle : Continuous or batch type. Variation Type : Cabinet Type & Multiparameter. Memory : 5000 records ( up to 16 measurement channels) with date and Time. Display type : Colour TFT LCD, size: 5.7'', resolution : 320X240 pixels LED backlit Resistive touch screen. Enclosure protection : Comply to IP65. MOC : SS 316 Power supply : 110- 230V AC,50Hz, 30 VA. Ambient temperature : 0 to 80 Deg. C Make: Optimus or equivelent make of Micro Set/Potence Control Pvt Ltd.
SEWAGE DISPOSAL WORKS
Supplying laying in trenches, jointing and testing DWCPE pipes (SN 8) 200mm OD/ 175mm ID ISI marked including jointing material complete all as specified and directed. (Excavation and earthwork shall be measued and paid seperately under relavent item of Sch 'A' Part-II)
Supplying and fixing RCC M-25 precast manhole cover slab size 600mm x 600mm x 75mm thick (using 12.5mm graded crushed stone aggregate) conforming to IS 12592 as in cover slabs supported on walls, manhole slabs, roofs, canopies deck slab, shelves & similar works complete all as specified and directed
Cleaning of blockage of sewer line manually by rodding from manholes and taking out solid/ semi solid sludge from manholes, removing and depositing in excavated pit to a distance exc 50m but not exc 250m including cleaning of sewer line by flushing of water and spreading of bleaching power over sludge deposited in the pit.
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
A.V BUILDERS
RYSA INFRATECH PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .