Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹74.2 L+₹14.6 L (24.5%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹72.6 L+₹13.0 L (21.8%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Other than being lowest | |
| 4 | Rejected-Technical 12 NO 12 IRATTAI PILLAYAR KOVIL STREET NEAR REAL VALUE FLAT VELACHERY 733 CHENNAI TAMIL NADU 600042 | CHENNAI | TAMIL NADU | 600042 | - | Rejected-Technical Two class below | |
| 5 | Rejected-Technical | - | Rejected-Technical Not having category d (v) |
Tender Value
₹64 L
EMD Value
₹1.2 L
Closing Date
11 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
MANNING AND OPERATION OF CWSS AND CERTAIN ALLIED WORKS AT NAVAL DOCKYARD UNDER GE (NW) KUNJALI
2021_MES_482881_1
8433/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) KUNJALI
Refer NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹1.2 L
Yes
20 Jan 2022
20 Oct 2021
13 Dec 2021
20 Oct 2021
11 Dec 2021
29 Nov 2021
20 Oct 2021 - 10 Nov 2021
60 days
Amount
Manning and operation including attending brakedowns of HT/LT network at CWSS sub stations 6.6 KV/433 volts with 6.6 KV incoming from INSS sub station and consisting of various sub stations and frequency convertor such , cruiser wharf sub station transformers, HT/LT braker, LT capacitor bank, battery chargers, LT panels, APFC panels, COPE points, distribution panels, including internal lighting/ventilention of the sub stations and manning duty round the clock in three shifts by skilled operator having minimum 3 years experince in electrical, mechanical and external electrification. carryout of maning duties by deploying the under mentioned manpower in three shifts incl Sunday/Holidays:- (i) Skilled Electrician - 02 Nos per shift for 03 shifts = 6 person per day Shift timings above are as under:- (a) First shift: 0600 hr to 1400 hr (b) Second shift: 1400 hr to 2200 hr (c) Third shift: 2200 hr to 0600 hr (ii) Skilled Electrician - 03 Nos in general shift= 3 persons per day Shift timings (a) General shift: 0900 hr to 1700 hr TOTAL NO OF PERSONS = 9 PERSONS Per day Note :- Skilled Elecrician must have diploma of three years from any Govt approved polytechnic college or an ITI qualified with five years experience in the trade
Manning and operation including attending brakedowns of HT/LT network at CWSS sub stations 6.6 KV/433 volts with 6.6 KV incoming from INSS sub station and consisting of various sub stations and frequency convertor such , cruiser wharf sub station transformers, HT/LT braker, LT capacitor bank, battery chargers, LT panels, APFC panels, COPE points, distribution panels, including internal lighting/ventilention of the sub stations and manning duty round the clock in three shifts by Mate Electrician having minimum 2 years experince in electrical, mechanical and external electrification. carryout of maning duties by deploying the under mentioned manpower in three shifts incl Sunday/Holidays:- Mate electrician - 01 Nos per shift for 03 shifts = 3 Notes :- (i) Mate electrician must have passed matriculation with minimum two years experience in the trade. TOTAL NO OF PERSONS : 3 PERSONS Per day Shift timings of above are as under:- (a) First shift: 0600 hr to 1400 hr (b) Second shift: 1400 hr to 2200 hr (c) Third shift: 2200 hr to 0600 hr
Note for item 1 & 2 (a) Surprise check will be carried out by department representative and if any employes is not available at his working place, he will be treated as absent. (b) Contractor has to submit the list of employees including reserve alongwith police verification, Aadhar card, Aadhar card linked Bank Account No and relevant documents as mentioned in PS to the Engineer-in-Charge alongwith performance security before issue work order. (c) The payment shall be made to employees on or before 10th of every calender month. Payment to employees shall be done by crossed cheque / RTGS / NEFT / IMPS through Aadhar card linked Bank Account only and it shall not be less than minumum fair wages as per Act in vogue (d) Contractor has to submit proof of payment of EPF subscription made by his alongwith RAR failing which RAR will not be progressed for payment (e) Contractor has to employ the number of labours per day as intimated by the Engineer-in-Charge for which he has to make alternative arrangement. (f) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (g) Contractor shall quote the rates considering their monthly leaves, releiver etc as per labour laws and nothing extra shall be paid on account of the above. In case of absence of staff/tradesman from duty, payment of that day will not be paid. In addition to that a penalty of Rs 1500/- per day per person will be recovered from contractors dues. Also in case of long absence (more than one week) of staff/tradesman, the penalty shall be recovered including Sundays & Holidays if any. The contractor shall have no claim on this account.
(h) Contractor has to supply three sets of Tools and Plants (as applicable) to the labours employed by him and should be placed with the safe custody of department. Rates quoted shall be deemed to be included the above provision. (j) In case any variation in manpower as indicated in Column No 4 of BOQ due to any reasons / or any manpower held in Department or any policy change contractor should have no claim on that account. (xiii) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost Item No 1 & 2 i.e Rs 48,58,364.00 , the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2) . (xiv). The deposited amount shall be the difference between estimated cost i.e Rs 48,58,364.00 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be. (xv) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working (m) Quotes rates should include Stationary,Uniform,Shoes,log book.etc
Material and labour for Flex board for Main receiving station and all 11/6.6kV distribution substations alongwith their fixing arrangement all as specified and directed.
Material and labour of the PVC board of appropriate size and thickness duly pasted with computerised letter mentioning " NO SMOKING" , " DANGER 11000 volts with skull and cross painted, " NO ADMISSION EXCEPT ON DUTY, " SM/MES NO." for the transformer/HT breakers/DG sets including accessories etc for the substations including accessories for properly fixing the same on wall/fencing/pole all as specified and directed.
Material and labour Chequered plate Fe 410-W (gde-E-250) quality A as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide and all as specified and directed.
Material and labour trench/duct cover,light weight,anti corrosive,with FRP pultruded section to meet specific load application of cable pit covering all as specified and directed.. Make: SYNTEX/LEGRAND/ERCON
Material and labour for fixing standard shock treatment chart in English & Hindi duly framed and covered with glass complete all as specified and directed.
Supply and fix of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( average ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set omplete all as specified and directed. Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Supply and fix cable jointing STRAIGHT THROUGH SCOTCHCAST JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (SCOTCHCAST)and accessories suitable for 3.5/4 core XLPE armoured, alluminum conductor cable of size 185 TO 240 sq mm and all as directed by Engineer-In-Charge.Make: Raychem/ 3M or as approved by GE
Supply and fix cable jointing STRAIGHT THROUGH SCOTCHCAST JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (SCOTCHCAST)and accessories suitable for 3.5/4 core XLPE armoured, alluminum conductor cable of size 240 TO 300 sq mm and all as specified directed by Engineer-In-Charge.Make: Raychem/ 3M or or as approved by GE
Supply and fix cable jointing STRAIGHT THROUGH SCOTCHCAST JOINT for 1.1KV grade cable for straight through joint complete with Jointing material (SCOTCHCAST)and accessories suitable for 3.5/4 core XLPE armoured, alluminum conductor cable of size 240 TO 300 sq mm and all as directed by Engineer-In-Charge.Make: Raychem/ 3M or as approved by GE
Supply and fix insulation rubber mat upto 3.3kV , having thickness not less than 2.00mm at various installation including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.Make: 3M/ Electromat or as approved by GE
Supply and fix insulation rubber mat more than 3.3kV upto 11 kV , having thickness not less than 2.50mm at various installation including pasting of rubber mats with adhesive resin all as specified and directed by Engineer-in-Charge.Make: 3M/ Electromat or as approved by GE
Shree Ayyappa Engineering
shakti engineering and electrical works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .