Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAdmitted-Finance HOUSE NO 152 NEAR D A V KAPILDEV PUBLIC SCHOOL DELATOLI KADRU DORANDA P O HARMU P S ARGORA KADRU RANCHI RANCHI JHARKHAND 834002 | RANCHI | JHARKHAND | 834002 | ₹26.9 L | L1 | Admitted-Finance |
| 2 | L2₹28.2 L+₹1.3 L (5.00%)Admitted-Finance | ₹28.2 L+₹1.3 L (5.00%) | L2 | Admitted-Finance |
| 3 | L3₹29.6 L+₹2.7 L (9.99%)Admitted-Finance | ₹29.6 L+₹2.7 L (9.99%) | L3 | Admitted-Finance |
| 4 | L4₹31.2 L+₹4.3 L (16.0%)Admitted-Finance | ₹31.2 L+₹4.3 L (16.0%) | L4 | Admitted-Finance |
| 5 | L5₹34.6 L+₹7.7 L (28.7%)Admitted-Finance | ₹34.6 L+₹7.7 L (28.7%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S ELECTRO EQUIPMENTS TRADING CORPORATION L4 | SADHAN ELECTRICAL ENTERPRISE L2 | CALCUTTA POWER CONSTRUCTION CO. L3 | SWARNENDU SARKAR L6 | SATABDI ENGINEERING COMPANY L5 | waystone engicon private limited L1 | RIK ENTERPRISE L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering with tile/brick and refilling the trench etc. as required ( As per IS 1255:1983 ). | ||||||||||
| 1.10 | Upto 35 sq mm. | 2,315 | Mtr | 400 ₹9,26,000 | 200 ₹4,63,000 | 380 ₹8,79,700 | 410 ₹9,49,150 | 432 ₹10,00,080 | 145 ₹3,35,675 Lowest | 215 ₹4,97,725 |
| 1.20 | Above 35 sq. mm and upto 95 sq. mm | 90 | Mtr | 450 ₹40,500 | 200 ₹18,000 | 382 ₹34,380 | 490 ₹44,100 | 469 ₹42,210 | 160 ₹14,400 Lowest | 246 ₹22,140 |
| 2.00Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. | ||||||||||
| 2.10 | Upto 35 Sq mm. | 60 | Mtr | 300 ₹18,000 | 200 ₹12,000 | 50 ₹3,000 Lowest | 160 ₹9,600 | 536 ₹32,160 | 100 ₹6,000 | 233 ₹13,980 |
| 3.00Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | ||||||||||
| 3.10 | Upto 35 sq. mm (clamped with 1mm thick saddle) | 203 | Mtr | 50 ₹10,150 | 100 ₹20,300 | 40 ₹8,120 Lowest | 56 ₹11,368 | 69 ₹14,007 | 50 ₹10,150 | 101 ₹20,503 |
| 3.20 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 7 | Mtr | 60 ₹420 | 100 ₹700 | 50 ₹350 Lowest | 139 ₹973 | 131 ₹917 | 50 ₹350 Lowest | 118 ₹826 |
| 4.00Supply & making end termination with brass compression gland and aluminium lugs and other materials for following sizes of 1.1 KV PVC insulated aluminium conductor armoured cables to the equipment complete as required. | ||||||||||
| 4.10 | 4 X 25 sq. mm (28mm) | 76 | Each | 300 ₹22,800 | 300 ₹22,800 | 350 ₹26,600 | 406.57 ₹30,899.32 | 434 ₹32,984 | 170 ₹12,920 Lowest | 390 ₹29,640 |
Tender Value
₹37.5 L
EMD Value
₹74,935
Closing Date
14 Aug 2026, 2:30 pmClosed
DIRECTOR, CSIR-CMERI
CSIR-CMERI, M. G Avenue, Durgapur 713209, West Bengal
Provision of Flood Lighting along the Boundary Wall at the Old Colony CSIR -CMERI, Durgapur
2026_CSIR_286491_1
10/1914/26-27/EC/Capital/ESD
Open Tender
Electrical Works
Item Rate
60 days
CSIR-CMERI COLONY, DURGAPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹74,935
4 Sept 2026
5 Aug 2026
17 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering with tile/brick and refilling the trench etc. as required ( As per IS 1255:1983 ). | |||||
| 1.1 | Upto 35 sq mm. | 2,315 | Mtr | - | - |
| 1.2 | Above 35 sq. mm and upto 95 sq. mm | 90 | Mtr | - | - |
| 2Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. | |||||
| 2.1 | Upto 35 Sq mm. | 60 | Mtr | - | - |
| 3Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. | |||||
| 3.1 | Upto 35 sq. mm (clamped with 1mm thick saddle) | 203 | Mtr | - | - |
| 3.2 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | 7 | Mtr | - | - |
| 4Supply & making end termination with brass compression gland and aluminium lugs and other materials for following sizes of 1.1 KV PVC insulated aluminium conductor armoured cables to the equipment complete as required. | |||||
| 4.1 | 4 X 25 sq. mm (28mm) | 76 | Each | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.99 MB
GCCFloodlight.pdf
Tender Documents • 15.86 MB
TenderAcceptenceUndertaking.pdf
Other Document • 0.80 MB
BOQ_334326.xls
BOQ • 0.36 MB
ScopeandMakefloodlightboundarywall.pdf
Additional Documents • 1.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .