Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹1.1 Cr+₹2.3 L (2.16%)Rejected-Finance | ₹1.1 Cr+₹2.3 L (2.16%) | L2 | Rejected-Finance ok |
| 3 | L3₹1.2 Cr+₹9.5 L (9.00%)Rejected-Finance | ₹1.2 Cr+₹9.5 L (9.00%) | L3 | Rejected-Finance ok |
| 4 | L4₹1.2 Cr+₹11.5 L (10.9%)Rejected-Finance DLG 13 14 PUSHPA COMPLEX HISAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | ₹1.2 Cr+₹11.5 L (10.9%) | L4 | Rejected-Finance ok |
| 5 | L5₹1.3 Cr+₹20.5 L (19.4%)Rejected-Finance 858 SECTOR 23 127021 2021R109 | BHIWANI | HARYANA | 127021 | ₹1.3 Cr+₹20.5 L (19.4%) | L5 | Rejected-Finance ok |
Tender Value
₹1.6 Cr
EMD Value
₹3.1 L
Closing Date
29 Mar 2022, 12:00 pmClosed
Ramesh Kumar XEN HWS Div. Hisar
Ramesh Kumar XEN HWS Div. Hisar
Constructing Pump House of 5 cusecs at village Dhad in the fields at lowest point alongwith laying of HDPE pipe line from RD O to RD 5650 along the road leading from Village Dhad to Badhawar, Out falling at RD 99000/L of Barwala Branch (For Abadi and
2022_HRY_213944_4
HWS-29.03.2022
Open Tender
Civil Works
Item-rate/Agreement basic
365 days
Hisar
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,000
Yes
₹3.1 L
Yes
19 Apr 2022
23 Mar 2022
29 Mar 2022
23 Mar 2022
29 Mar 2022
23 Mar 2022
Amount
Providing and laying in position ready mixed plain cement concrete M-15, with cement content as per approved design mix andmanufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuousagitated mixer, manufactured as per mix design of specifiedgrade for plain cement concrete work, including pumping ofR.M.C. from transit mixer to site of laying and curing, excludingthe cost of centering, shuttering and finishing, including cost ofcuring, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workabilitywithout impairing strength and durability as per direction of theEngineer-in-charge.(Note:- Less cement used as per design mix is recoverable. However no extra payment shall be made if excess cement is used as per design mix for sleepers). M-15 grade plain cement concrete (cement content considered @ 240kg/cum) as per HSR item No. 6.22.2.2 @ Rs.4224/- per cum
Brick work in 1:4 (1 cement 4 course sand) mortar with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth complete as per HSR. 7.21.1) @ (4135)/cum - Brick Bats
Steel reinforcement of thermo mechanically threaded bars of graded Fee-500D for RCC work , where not included in the complete rate of RCC i/c straightening, cutting bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wires etc.complete in all respect above plinth level as per HSR 6.33.6 @68/kg or 6800 per Qtl
Earth work in excavation by mechanical means (Hydraulic Cum excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 mt as directed by Engineer-in- charge. (HSR 4.12.1) @ 87 per cum
Centering and shuttering i/c strutting, proping and removal of form work for roof, landing etc, complete as per HSR 6.30.3 @ 233/ sqm
Providing and laying in position ready mixed M-25 grade cum concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level up to floor IV level as per HSR item No. 6.25.1 @ Rs 4999/- per cum
Centering and shuttering i/c strutting, proping and removal of form work for foundation, footing and bases of colomns etc, complete as per HSR 6.29.1 @ 174/ sqm
Centering and shuttering i/c strutting, proping and removal of form work for walls (any thickness) i/c attached pillars etc, complete as per HSR 6.30.2 @ 316/sqm
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel angle sections of size 35x35x5 mm, joint mitred and welded by angle iron 35x35x5 mm or 35x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener i/c fixing of necessary butt, hinges andscrew and applying prming cat of approved steel primer all complete as per direction of engineer incharge.as er HSR 13.2 @ 84 per Kg
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and comers, all necessary fittings complete, including applying a priming coat of approved steel crimer. Using M.S. angels 40x40x6 mm for diagonal braces as per HSR 13.6.1 @ 3066 per sqm
12 mm thick cement paster in1:4 on brick walls compete mtr as per HSR- 11.5.3 @94/Sqm
Providing and laying brick tiles over mumty roofs, grouted with cement mortar 1 :3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1 :3 HSR (19.14.1) With common burnt clay non-modular brick tiles of class sqmdesignation 1 O @ 419 per sqm
E/Work cavation trenches of required width of pipes, cable etc.i/c excavation or sockets and dressing of sides, ramming of bottoms depth up to 1.50 mtrs , i/c getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm depths, i/c consolidaing earth deposited layers by ramming watering etc.and deposing of surplus excavated soil as directed, with a lead of 50 mtrs for pipe/cable etc.with 300 mm dia but not exceeding 600 mm dia (HSR 4.16.1.3) @ 96/mtr
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade and PN- 4 as per IS 4984-2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications.Rate includes cost of all specials like bends, tees required during laying of pipe line along required alignment. 400 mm outside dia .NS item
Providing & fixing 300 mm i/d cast iron double flanged swing check type reflux (non return) valves PN-1.6 marked with IS:5312 including nuts & bolts marked with IS:1363, rubber sheet marked with IS:638 etc., carriage loading, unloading, stacking, handling, re-handling etc. Complete in all respect to the satisfaction of Engineer-in-charge (HSR 20.11.6) @ 19417 each
Providing and fixing 300 mm dia C.I. sluice valves class-I (with cap) c omplete with bolts, nuts,rubber insertions etc. (HSR 22.162.6) @25683 each
Supply and installation of 50mm i/d hydraulic pressure relief valve of polemeride with accessories for pressure regulation of irrigation system as per B IS standard. (HSR 26.73.10) @ 16041 each
Providing and fixing 50 mm dia C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (HSR 22.185.1) @ 4941 each
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in Grating, frames Guard bars, ladder , railing, brackets, gates complete( as per HSR 13.29.1) @ Rs.93 per Kg
Supplying, erection, testing and commissioning of Submersible motor pumping set non clog for sewerage having head 24.00 mt as per the indicated requirements of discharge in 8500 LPM and power capacity in 75 BHP Make: KSB, CRI, Kirtosker, Crompton Greeve, Lubi, Aqua, Kishore, Mather & Platt, Beacon Wier, Flow more & WPIL) (Quotation attached @ 922621+12%C.profit+12% GST
Supplying of fully automeic electric control panel board for tube-wells or in pump chambers consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle frame containing one No.fuly autometic air brake starter suitable for motor of the following capacity. (min.switches of suitable range with HRC fuse, One No.volt meter (0 t 500 volt), One No. amp.meter (0 to 100 amp), 3 sets of indicative lamps, capacitor of suitsble capacity and i No single phase prevents with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric control panel board complete in all respect as per specifications given in schedule II, i/c MCB suitable capacitor, wooden box etc complete in all respectas per Quatation attached @90945+18%GST
Dismentling of brick masonary and sorting out the serviceable material and disposal of unservice/waste material upto a distance of 100mtr as per direction of Engineer-incharge. As per HSR item No. 8.5(b) Old HSR
Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge.complete as per HSR 20.62.3 for 300 mm dia @531 per mtr
Removing hume/RCC pipes 600 mm dia NP2. HSR item No. 8.35 (b) Old HSR
Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge.complete as per HSR 20.62.8 for 600 mm dia @1102 per mtr
Supply & fixing 300 mm dia MS Pipe with 7.35 mm thickness (HSR EL 265) Basic rates @ Rs.4532 per mtr
Credit for old Brick work
RAJ KUMAR MALIK CONTRACTOR
Rajiv Tihal Contractor Baliyali
The Tibba Dana Sher Co op L and C Society Ltd
M/S SHREE BALAJI BUILDERS
BHIM SAIN CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .