| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹1.5 L
Closing Date
19 Feb 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_116647_1
Fresh e-NIT No.EDJ/166 of 2020-21 Dated 13-02-2021
Open Tender
Electrical Works
Item Rate
15 days
New Delhi
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
23 Feb 2021
13 Feb 2021
20 Feb 2021
14 Feb 2021
19 Feb 2021
14 Feb 2021
Amount
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate,, suitable GI box and earthing the point with 1.5 sqmm FR PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for twin control lightpoints with 1.5sq mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit 2 way modular switch, modulatr plate suitable GI box and earthing the point with 1.5sq mm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for Submain wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor single core cable in surface/ recessed PVC conduit as required.
2X2.5 sq. mm + 1X2.5 sq. mm Earth wire.
2 x 4 sq.mm. + 1 x 4 sq.mm. Earth wire
Supply and fixing of stepped type electronic fan regulator(Double module) on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches in recess etc as required
1 or 2 Module (75 mm x 75 mm)
Supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required
Telephone Socket outlet
Supply and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required :
Supplying and drawing following pair, 0.5.mm dia FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 & 5/6 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required.
Supplying and fixing 5 amps. to 32 amps. rating, 240/415 volts `C' series, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB/panel complete with connections, testing and commissioning etc. as required.
Single pole
Single pole and neutral 20-25 amps
Single pole and neutral 40 amps
Supply Supply Installation, testing and commissioning of following sizes of fresh air fan suitable for single phase 230 volts, 50 Hz AC supply complete with motor, capacitor, louvers / shutters etc. complete as required. Crompton/Havells/ORIENT
8" brisk air .
Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way , Double door
Supplying and fixing suitable size GI Box with modular plate and cover in front on recessed including providing and fixing of SPN 25/32 amps modular DP (for Air Conditioners), connections etc as required.
Light Fixtures Supply Installation, testing and commissioning of recessed / surface / wall mounted LED Panel light luminaires with all accessories complete as required including cutting and making space in existing false ceiling for fixing the light fixture
LED Tuberod Fitting basic for cove lighting PHILIPS/Wipro/Havells as Approved.
Supply Installation, testing and commissioning of 240V, 1 phase 5 star Ceiling Fans complete with suitable length down rod as required.
1200mm sweep .
Supplying and fixing of following sizes (oscillating type) wall mounting fan with necessary connection (Orient PSPO, Havells, CG.
300 mm sweep wall mountaing fan
AIR CONDITIONERS Supply of 1.5 ton 5 star Split Airconditioners Full Copper Make: CARRIER, HITACHI, Blue Star, Diakin.
Installation of Split ACs
Supply of Following Accessories for Split Airconditioners
Stand for O/D
Copper Piping
Electric Wiring
Drain Piping
MVD ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .