| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L1 | Accepted-AOC Contract was awarded to lowest bidder | |
| 2 | L2₹40.0 L+₹5.1 L (14.7%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹41.6 L+₹6.8 L (19.5%)Rejected-Finance 792 2 A CIVIL LINES NEAR BABULAL MILL GWALIOR ROAD JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹41.6 L+₹6.8 L (19.6%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹42.0 L+₹7.2 L (20.6%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L5 | Rejected-Finance Not become lowest bidder |
| Sl No | Description | Qty | Unit | VIJAY BUILDERS L6 | M/S Kumar Contractors L4 | V K Engineers and Associates L3 | M/S S K AGARWAL L2 | ADARSH ENTERPRISES L5 | FTH TRADERS L1 | M/sDaljeet singh keer L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in soft loose soil, complete all as specified and directed | 20 | Sqm | 110 ₹2,200 | 110 ₹2,200 | 100 ₹2,000 | 50 ₹1,000 | 100 ₹2,000 | 35 ₹700 Lowest | 80 ₹1,600 |
| 2.00 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15cm thick (below or above ground level) built in cement mortar, complete all as specified and directed. | 63.75 | Cum | 300 ₹19,125 | 330 ₹21,037.5 | 350 ₹22,312.5 | 370 ₹23,587.5 | 350 ₹22,312.5 | 150 ₹9,562.5 Lowest | 450 ₹28,687.5 |
| 3.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for | 19.5 | Qtl | 300 ₹5,850 | 265 ₹5,167.5 | 250 ₹4,875 Lowest | 400 ₹7,800 | 280 ₹5,460 | 350 ₹6,825 | 290 ₹5,655 |
| 4.00 | Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame). Complete all as specified & directed. | 14 | Each | 100 ₹1,400 | 110 ₹1,540 | 110 ₹1,540 | 120 ₹1,680 | 120 ₹1,680 | 75 ₹1,050 Lowest | 100 ₹1,400 |
| 5.00 | Demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed. | 60 | Cum | 280 ₹16,800 | 300 ₹18,000 | 300 ₹18,000 | 350 ₹21,000 | 380 ₹22,800 | 150 ₹9,000 Lowest | 300 ₹18,000 |
| 6.00 | M&L for brick work with old size fly ash bricks, straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and directed. | 68.06 | Cum | 5,800 ₹3,94,748 | 5,500 ₹3,74,330 | 4,850 ₹3,30,091 | 4,400 ₹2,99,464 Lowest | 4,650 ₹3,16,479 | 4,800 ₹3,26,688 | 5,500 ₹3,74,330 |
| 7.00 | M&L for 10 mm rendering thick in CM (1:6) on fair faces of brick work/concrete surfaces finished even & smooth (without using extra cement), complete all as specified and directed. | 260 | Sqm | 150 ₹39,000 | 140 ₹36,400 Lowest | 180 ₹46,800 | 140 ₹36,400 Lowest | 165 ₹42,900 | 165 ₹42,900 | 169 ₹43,940 |
| 8.00 | M&L for Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers(first coat 10 mm & second coat of 5 mm ) mixed with WPC as per menufacturers intructions, finished even and smooth without using extra cement complete all as specified and as directed. ( Note: Water proofing compound shall be measured & paid separately) | 292 | Sqm | 160 ₹46,720 Lowest | 170 ₹49,640 | 175 ₹51,100 | 170 ₹49,640 | 180 ₹52,560 | 200 ₹58,400 | 165 ₹48,180 |
| 9.00 | M&L for liquid Integral waterproofing compound | 62.24 | Kg | 100 ₹6,223.91 | 120 ₹7,468.69 | 130 ₹8,091.08 | 120 ₹7,468.69 | 120 ₹7,468.69 | 95 ₹5,912.71 Lowest | 110 ₹6,846.3 |
| 10.00 | Preparing newly plastered wall surfaces of wall and applying three coats of whitewash complete all as specified and direted | 32 | Sqm | 25 ₹800 | 22 ₹704 | 25 ₹800 | 22 ₹704 | 24 ₹768 | 20 ₹640 | 14 ₹448 Lowest |
Tender Value
₹46.7 L
EMD Value
₹93,480
Closing Date
13 Mar 2026, 6:00 pmClosed
Maj Rajesh Rathore
Garrison Engineer Jhansi
SPL REPAIR TO BLDG NO P-133 AT STOCKING WING OF ARMD DIV ORD UNIT AND PROVISION OF CHAIN LINK FENCING FROM KV NO 1 SCHOOL BOUNDARY WALL TO OFFR MESS NEW KLP AND OTHER MINOR WORK UNDER AGE B/R-I UNDER GE JHANSI
2026_MES_753459_1
GE/JHA/TOK/83 OF 2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
GE Jhansi
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹93,480
Yes
15 May 2026
20 Feb 2026
16 Mar 2026
20 Feb 2026
13 Mar 2026
6 Mar 2026
20 Feb 2026 - 5 Mar 2026
Surface excavation not exc 30 cm deep and averaging 15cm deep and getting out in soft loose soil, complete all as specified and directed
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15cm thick (below or above ground level) built in cement mortar, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
Taking down Chowkats or frames Not exceeding 1.5 Sq. M each (Without taking off shutters from the frame). Complete all as specified & directed.
Demolition of brick work built in cement mortar or lime mortar including all quoins arches, pillars etc complete all as specified and directed.
M&L for brick work with old size fly ash bricks, straight or curved on plan exc. 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for 10 mm rendering thick in CM (1:6) on fair faces of brick work/concrete surfaces finished even & smooth (without using extra cement), complete all as specified and directed.
M&L for Rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two layers(first coat 10 mm & second coat of 5 mm ) mixed with WPC as per menufacturers intructions, finished even and smooth without using extra cement complete all as specified and as directed. ( Note: Water proofing compound shall be measured & paid separately)
M&L for liquid Integral waterproofing compound
Preparing newly plastered wall surfaces of wall and applying three coats of whitewash complete all as specified and direted
M&L for preparation of new plastered of wall surface and applying two coats of oil bound distemper, over a coat of chalk whitening primer over and incl a layer 3mm thick of wall care putty to get even and smooth level finish on new plastered surface of internal wall, complete all as specified and as directed.
M&L for preparation of surfaces of walls and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint (weather proof) of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. complete all as specified and directed. Note : The contractor shall produce batch certificate & delivery challans directly from paint manufacturer to establish the authenticity of the material. The batch testing certificate shall be brought at the site along with paint manufacturer's drums with seal intact.
M&L for complete removal of existing treatment and preparation of surfaces of walls by scrapping/sand paper rubbing and finally washing with watering and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint (weather proof) of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces. complete all as specified and directed. Note : The contractor shall produce batch certificate & delivery challans directly from paint manufacturer to establish the authenticity of the material. The batch testing certificate shall be brought at the site along with paint manufacturer's drums with seal intact.
M&L for complete removal of existing treatment by brushing, washing, rubbing down, scraping from old treated surfaces of wall and applying two coat of oil bound distemper over a coat of chalk whitening primer, over a layer of (JK/Birla) 3.0 mm thick wall care putty to get smooth and level finish, complete all as specified and directed.
Dismantling asbestos cement (corrugated or semicorrugate etc) sheet in roof covering, complete all as specified and directed.
S&F of pre-painted 0.50mm thick Gavalume Aluminium Zinc coating GI based corrugated / semi corrugated / trapezoidal steel sheet of any colour having tensile strength 550 MPa and AZ 150 grade as in roof covering/cladding to walls, fixed with self tapping screws, complete all as specified and directed.
S&F pre-painted Galvalume Aluminium Zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength 550 MPa and AZ 150 grade as in ridge of roof covering, fixed with self tapping screws, complete all as specified and directed.
M&L for structural steel Fe-410-W(Gde-E-250) quality A for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed.
Excavation in post holes (for similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubbed mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil. Complete all as specified and directed.
M&L cement concrete 1:4:8 type D2 (40mm graded stone aggregate) in foundation filling and mass concrete.Complete all as specified and directed.
S&F framed work such as grills, gratings etc with ends of bars shoulders and/or riveted, orfoeged into spikes, framed guards bars barred iron doors, ladders framed balusters walk ways railling framework and similer work confirming to Fe-290 Gde E-165. Complete all as specified and directed.
S&F 1.25 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched incl round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with rivets or welded seams, incl bending or turning up, mitred angles etc, as specified & directed.
M&L for box type steel window with 80x40x1.25 mm MS tubular frame with side hung shutters ( double shutter for glass and gauze) without sash bars jointed together with and incl grill using 12 mm square bar @ 10 cm C/C incl box type hinges with steel handle and steel pag stay complete glazing bars doweled and welded complete all as specified as directed. Note:- (a) The 4.0 mm thick plain glass and wiremesh of 0.56 mm in nominal dia of wire and average width of aperture 1.18 mm are included in quoted rates. (b) Side hung Z-Section shutter shall be of size 20mm x 20mm x 25mm and 3 mm thick.
M&L for 75 mm thick cement concrete type D2 1:4:8 (using 40 mm graded stone agg) in sub base of flooring/ hard standing complete all as specified and directed.
M&L for 75 mm thick cement concrete type C2 1:3:6 (using 40 mm graded stone agg) in sub base of flooring/ hard standing complete all as specified and directed.
M&L for hard core of gauge not exceeding 63mm, broken stone or boulders, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
Dismantling stone slabs and tiles of any description or thickness laid , bedded and pointed in any mortar as in floors, aprons etc. complete all as specified and directed.
M&L for factory made machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with coloured pigment made of PVC moulded (or rubber mould) with vibrating system, with and including 50mm thick sand cushioning, including in CM (1:3) in edges of pavers, complete all as specified and directed. (Note : The cost of sand cushion and plastering to edges is included in quoted rate.)
Demolition of RCC Not exc 15cm thickness Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work
M&L for RCC Type B1 1:2:4 (using 20 mm stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span.
S&F mild steel TMT bars 10 mm dia & over, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
S&F mild steel TMT bars 5 mm dia & over upto 10 mm as in stirrups, cut to length bent to shape required, including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified & directed by Engineer-in-Charge.
M&L for Formwork to sides & soffits of lintel beams, bands, cantilivers, shelves etc complete all as specified & directed by Engineer-in-Charge.
M & L for two coat of synthetic enamel paint over one coat of red oxide, zinc chromiume on steel surface including preparation of new or previously untreated steel surface width or girth exc 10cm all as specified and directed.
M&L for preparation of old steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed
M&L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in foundation filling, mass concrete and similar works and for MS Pipe fixing.
M & L for angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as directed by Engr-in-Charge.
Supply and fixing 10mm dia mild steel round bars(straight or cambered) bearing bars or similar items such as bars for tightening of chain link fencing complete all as specified and directed.
M&L, preparation of new iron surfaces of any discription n exc 10 cm widthand girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed.
Supply and Fixing chain link fencing of MS GI wire mesh of size 100x 100 mm of 4 mm dia of GI wire including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire.
S&F mild steel screw bolts ( machine made) with hexagonal heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut not exc 5cm and dia of shank 11 to 15mm complete all as specified and directed.
Taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, regulators, sockets, bell push and call bell wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:-
One light point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item No 43 here-in-before but with 4 sq mm FRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2 runs X 2.5 Sqmm (Ph & N) + 1 run X 2.5 Sqmm (earth wire).
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
Notes for item No. 45.00 to 45.03: (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
S&F of Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F of Socket 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F of Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F of ceiling rose three terminals bakelite body 240 volts complete all as specified and directed.
S&F of integrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
Supply and fixing of exhaust fan, steel body AC single phase, 230 V of size 450 mm sweep heavy duty with blades, frames and louvers complete all as specified and directed.
S&F in repairs of LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
Supply and fix of LED flood lights fittings 210 W made up of pressure die cast aluminium housing with toughened glass and high power LED's and secondary leneses with IP-66 protection system efficiency > 110 LPW, 10 KV SPD as per crompton/Bajaj/Havells including fixture arrangement i.e FI clamp 30x5 mm with with nuts, bolts washers including trade work as required for fixing of lights on walls / columns/PEB structure complete all as directed.
S&F of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately.
Supply and fix MCB distribution board, SPN, 8 way 230 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed by Engineer-in-Charge. Note: MCBs shall be measured and paid separately.
S&F of MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed.
S&F of MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Supply and fix in replacement of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz including taking down existing unserviceable MCB of any description complete all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- (a) The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. (b) Earthing result should be less than 3 Ohm required.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 25 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium strip 25 x 3.15mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point all as specified.
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm Long complete all as specifeid and directed by Engr-in-charge.
M&L for lightening conductor assembly made out of GI pipe light grade of size 40 mm bore along with welded flange, fixed on the roof with drilling/making hole and provide rubber washer 6mm thick of suitable size and connect to air termination & connector for earth strip duly fixed with necessary nuts bolts & washers in PCC 1:3:6 type C1, of size 20cm x 20 cm x20 cm complete all as directed by Engr-in-charge. Note :- GI pipe 40mm (1 RM for each), PCC & air temination shall be measured & paid separately under relevant items
Supply and fix galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe complete all as specified and directed.
M&L GI pipe 40mm dia Medium grade for GI Strip Protection and fixed for air termination point complete.
M&L for earthing complete with galvanized steel earth electrode 60 cm x 60 cm x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with the top edge not less than 1.5 mtr below ground level connected to galvanized iron or steel earth lead, GI strip 32x6 mm dia by means of bolts, nuts, chock nuts and washers and other end connected to earthing test point in 40mm GI medium grade pipe for prtection including funnel, watering pipe of 20 mm bore (Light Grade) GI pipe wire mesh, charcoal or coke and common salt in alternate layers all around the earth electrode compacted thickness 15 cm, earthing pit in PCC (1:3:6) type C1, 50 mm thick pre cast RCC cover slab (1:2:4) type B1 set in CM (1:4), reinforced with 8 mm dia TMT bars @ 15 cm c/c and suitable handle of 10 mm dia MS round bars including earth work in excavation in soft/loose soil, desposal of soil not exc. 50 mtr complete and testing on completion all as shown in electrical plate No-5 of MES schedule, part-I complete all as specified and directed. (NOTE :- Rate quoted by the tenderer shall be deemed to include for the following provisions:- (i) Item includes the cost of 7.5 m GI pipe for protection of GI strip (ii) Item includes the cost of 7.5 m of GI strip (iii) PCC pit shall be provided at least 500 mm away from pit and not on the earth pit itself and the extra cost of additional length of watering pipe bends, elbow etc shall be deemed included in the unit rate.
Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point completed all as specified.
Supply & Fixing of epoxy insulator of required size with two nos hole each on both end for fixing properly with fastner, nuts & bolts on wall & roof of buildings for separated earthing stirp from building complete all as specified and directed by Engineer-in-Charge.
S&F turbo air ventilator (wind driven) with material of construction top plates and bottom ring stainless steel, cross strips stainless steel, pipe assembly coverting shaft of stainless steel, fins and riverts stainless and throat dia 24" and number of fins 42 fins and all as specified and directed.
S&F joist, channel, angle or tee sections Fe-410-W (Gde-E-250), Quality-B), fixed independently without connecting plates, etc. (cut to ordinary i.e. within 20mm of the length indicated completed all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_843925.xls
BOQ • 0.58 MB
Tenderdocumentstoken83.pdf
Tender Documents • 1.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .