Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.9 CrAccepted-AOC UNIT NO 514 515 AND 516 5TH FLOOR SUNCITY SUCCESS TOWER GOLF COURSE EXTENSION ROAD GURGAON 122005 | GURGAON | GURGAON | HARYANA | 122005 | ₹1.9 Cr | 1 | Accepted-AOC 1st lowest bidder |
| 2 | 2₹2.6 Cr+₹66.6 L (35.0%)Rejected-AOC | ₹2.6 Cr+₹66.6 L (35.0%) | 2 | Rejected-AOC 2nd lowest bidder |
Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
25 Jul 2022, 3:00 pmClosed
Executive Engineer
PHED-3, Hisar
Request for Proposal for Appointment of Consultant for Providing Consultancy services for DPR preparation and Bid Process Management for Providing Sewerage and Storm Water Drainage and Associated Works for International Airport Hisar
2022_HRY_230551_1
SE memo no. 12201 dated 15.07.2022
Open Tender
Civil Works
Works
120 days
Hisar
as per DNIT
3 documents required · 3 mandatory
₹15,000
₹4.4 L
Yes
12 Dec 2022
15 Jul 2022
25 Jul 2022
15 Jul 2022
25 Jul 2022
15 Jul 2022
Amount
Conducting topographical land survey in the specified area of 7200 acre using Total Station & DGPS covering details of all physical features like Rivers, Nallahs, Lakes, Ponds, wells, pits, Forest, Trees, Roads, culverts, transmission lines, telegraph/telephone and electric poles, underground or any other services, cross drainage works including cross sectional details of nallah etc. including establishing high flood level with source of information, identification of any monument, historical structure, wild life sanctuary in the vicinity, storm water disposal point with levels, cross-section details of nallah, recording spot levels, including providing in tabulation girth wise no. of trees etc as specified, plotting, NSL at 7 Mtr sapcing and developing topographical contour maps with 7 m spacing, showing true north including establishing survey reference stations/TBM with respect to GTS, key plan etc. including all equipment's, instruments, personnel's, clearing of bushes as per requirement for intervisibility to carry out survey work etc., Constructing 300mm x 300mm x 1000mm size boundary pillars / Survey reference stations in plain cement concrete of M-20 grade with 20mm and down size graded stone aggregate with 500mm below ground level and 500mm above ground, including earthwork in excavation, backfilling and spreading surplus earth, shuttering, tamping, ramming, vibrating, curing and finishing the top and sides rough or smooth, complete work in all respects as per specifications and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Carrying out soil investigation / stratification / laboratory testing work including preparation of report, providing all manpower, tools, tackles, materials, equipment’s and other support, facilities (including mobilization and demobilization as required) necessary for the work, boring minimum 150 mm nominal diameter borehole from Existing Ground Level (EGL) to 20 m depth or upto rocky strata including Coring in Rock of Nx size with double tube core barrel with diamond bits for Conducting the Standard Penetration Tests, Conducting Atterberg's limit (Liquid Limit & Plastic Limit), Conducting Natural water content on soil & rock samples, Conducting Bulk and dry density tests on soil & rock samples, Conducting Specific gravity and void ratio tests on soil & rock samples, Grain size analysis on soil samples using sieve analysis & Hydrometer, Conducting triaxial Unconsolidated Undrained (UU) test on soil samples, Conducting Unconfined Compression Tests on soil samples as specified, Conducting Direct Shear Test on soil samples as specified, Conducting Consolidation tests on soil samples as specified, Conducting Attreberg's limit, Conducting Standard Proctor Density test on soil samples, Conducting Modified Proctor Density test on soil samples, Laboratory CBR Tests on soil samples, Conducting Laboratory Unsocked CBR Tests on soil samples as specified, Conducting Laboratory Socked CBR Tests on soil samples as specified, Conducting Unconfined Compression Test on Rock samples, Conducting Point Load test on Rock samples, as per standard procedures and relevant IS codes Conducting in boreholes as in accordance with requirements of specifications and as per instruction of the Engineer-in-charge. (1 borehole per 100-acre area so for 7200-acre area total 72 Nos. Of borehole)
Design and drawing of Storm Water Collection system at 3 identified collection points of storm water drainage of 5595 acres area of Airfield including Civil, Electrical & Mechanical components all complete in all aspects including structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of open / box type storm water drain network in 5595 Acre area of Airfield from 3 identified collection points of storm water drainage upto the disposal point as required with cross- section drawing/ L-section including Route survey of Strom drain & its alignment and submission of design drawings showing L- Section, cross section at every 25 meters and additional cross sections where ever required, structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of storm Sewer network in 5595 Acre area of Airfield from 3 identified collection points of storm water drainage upto the disposal point as required with cross- section drawing/ L-section including Route survey of Sewer line & its alignment and submission of design drawings showing L- Section, cross section at every 20 meters and additional cross sections where ever required, structural design duly vetted from IIT/NIIT complete work in all respects as per specifications and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of Storm Water Collection system for 87 Cuse discharge of IMC at 01 No. identified collection points of storm water drainage of 1605 acres area of IMC including Civil, Electrical & Mechanical components all complete in all respects including structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of Storm Water conveyance system for 87 cuse discharge of IMC from storm water collection point of IMC upto final disposal point as required with cross- section drawing/ L-section including Route survey of Strom drain & its alignment and submission of design drawings showing L- Section, cross section at every 25 meters and additional cross sections where ever required, structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of treated water effluent( generated from STP) collection system of 1605 acre area of IMC including Civil, Electrical & Mechanical components all complete in all aspects including structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of treated water effluent( generated from STP) collection system of 5595 acre area of Airfield including Civil, Electrical & Mechanical components all complete in all aspects including structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Design and drawing of conveyance system of treated water effluent generated from STP in 1605 acre area of IMC and 5595 acre area of Airfield from collection system of 1605 acre IMC area and collection system of 5595 acre Airfield area upto final disposal point as required with cross- section drawing/ L-section including Route survey of Strom drain & its alignment and submission of design drawings showing L- Section, cross section at every 25 meters and additional cross sections where ever required, structural design duly vetted from IIT/NIIT complete work in all respects as per specifications & IS codes and directions of Engineer-in-Charge including submitting hard copies of drawings/map and supply of electronic files in appropriate scale to the satisfaction of Engineer in Charge / AAI Personnel.
Preparation of Bid Documents & Bid Process Management for Engagement of Contractor for performing the tasks
KY Consultants pvt ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .