| 1 | L1₹4.8 LAccepted-AOC 140 DEORISINGHPURA RANIPUR JHANSI JHANSI UTTAR PRADESH 284205 | JHANSI | UTTAR PRADESH | 284205 | L1 | Accepted-AOC VALID | |
| 2 | L2₹6.4 L+₹1.1 L (20.1%)Rejected-Finance WARD NO 13 NEW SURATGARH | SURATGARH | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹6.7 L+₹1.4 L (25.9%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹6.9 L+₹1.6 L (29.1%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
13 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SURATGARH
GE (AF) SURATGARH
REPAIR MAINT OF HANGAR LIGHTS GO-NO-GO LIGHTS AND CONNECTED EM WORKS AT AF STN SURATGARH
2021_MES_451653_1
8891/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹20,000
Yes
28 Oct 2021
15 Jun 2021
15 Jul 2021
15 Jun 2021
13 Jul 2021
29 Jun 2021
60 days
Amount
BOQ ( REPAIR/MAINT OF HANGAR LIGHTS, GO-NO-GO LIGHTS AND CONNECTED E/M WORKS AT AF STN SURATGARH)
Taking down existing old unserviceable underground LT cable upto size 50 Sqmm, 4/3.5 /2 core keeping aside for reuse/removal from trenches/ wall/pole , complete all as specified and directed by Engineer-in-Charge. NOTE : Excavation and earth work shall be measured and paid separately.
XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 50 Sqmm 3.5 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles ,complete all as specified and directed by Engineer-in-Charge.
XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 35 Sqmm 3.5 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles ,complete all as specified and directed by Engineer-in-Charge.
XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 25 Sqmm 4 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles ,complete all as specified and directed by Engineer-in-Charge.
XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 16 Sqmm 4 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles ,complete all as specified and directed by Engineer-in-Charge.
XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured, electric power cables (Heavy duty) with stranded aluminium conductor, 1100 volts grade (earthed) cross sectional area 10 Sqmm 2 core, laid in trenches, through pipe in road crossing, ducts, fixed along poles ,complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5m wide and and not exc. 1.5m depth wide in soft/loose soil for laying electric cables/pipes etc including getting out excavated earth and trimming the sides and bottoms of trenches , complete all as specificed and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point , complete all as specified and directed by Engineer-in-Charge.
Sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth (punned down to 10 cm depth after laying and stretching of cable), complete all as specificed and directed by Engineer-in-Charge. Note: Punned thickness (over all 18 cm) shall be measured & paid.
Brick of common burnt clay, sub class 'B' old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cables abutting each other , complete all as specified and directed by Engineer-in-Charge.
Galvanised iron steel tubes, ISI marked light grade of size 80 mm bore for cable protection along the poles under road under drains, laid in trenches/fixed on walls/poles with suitable clamps bolts nuts etc including taking down of old unserviceble pipe , complete all as specified and directed by Engineer-in-Charge.
Open construction heavy duty copper ballast for HPSV/MH 400 W light fittings including taking down of old unserviceble ballast , complete all as specified and directed by Engineer-in-Charge. Make : CG/Wipro/Havells/Philips
MH lamp 400 watts (DE) ,fixed as in replacment of old unservicable material , complete all as specified and directed by Engineer-in-Charge. Make : CG/Wipro/Havells/Philips
Open construction heavy duty copper ballast for HPSV/MH 150 W light fittings including taking down of old unserviceble ballast , complete all as specified and directed by Engineer-in-Charge. Make : CG/Wipro/Havells/Philips
MH lamp 150 watts (DE) ,fixed as in replacment of old unservicable material , complete all as specified and directed by Engineer-in-Charge. Make : CG/Wipro/Havells/Philips
Ignitor for 250W/150W/400W HPMV/HPSV/MH light fittings ,fixed as in replacment of old unservicable material , complete all as specified and directed by Engineer-in-Charge. Make : CG/Wipro/Havells/Philips
Gong bell (Buzzer type) electric 230 volt AC, 50 Hz for GO NO-GO lights, fixed as in replacment , complete all as specified and directed by Engineer-in-Charge. Make-Anchor/Havells/Bajaj
LED Highbay 150 Watt suitable for Hangers / industrial application heat sink made of copper & equipped with fluid dynamic pressure technology ,lumen efficacy > 120 lm/w , CRI > 85% ,THD < 15% UL certified , driver equipped with double power embedded system, & automatic Power Shutdown and returning circuit embedded with Power supply, which turns off power against Fire, High Temperature, Over-voltage and Over-current. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, including taking down old unserviceable light fitting , complete all as specified and directed by Engineer-in-Charge. Make: Havelsl Cat No SAUCERPLUSHBP150WLED8579DTOLGTG or equivalent makes as specified in Appendix 'B' List of Makes.
LED Highbay 120 Watt suitable for Hangers / industrial application heat sink made of copper & equipped with fluid dynamic pressure technology ,lumen efficacy > 120 lm/w , CRI > 85% ,THD < 15% UL certified , driver equipped with double power embedded system, & automatic Power Shutdown and returning circuit embedded with Power supply, which turns off power against Fire, High Temperature, Over-voltage and Over-current. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report, including taking down old unserviceable light fitting , complete all as specified and directed by Engineer-in-Charge. Make: Havelsl Cat No SAUCERGENXPROHBT100WLED757P60DBOLTG or equivalent makes as specified in Appendix 'B' List of Makes.
LED flood light 150 watt with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 16500 Lumens) color rendering (CRI) of > 75 and co-related color temperature (CCT) of 5700K (+ 500K), The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance. The driver used must be a constant current driver with efficiency of > 85%. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report , including taking down old unserviceable light fitting , complete all as specified and directed by Engineer-in-Charge. Make : Havells Cat No JETAIRISFLS150WLED757PSYMLTG or equivalent makes as specified in Appendix 'B' List of Makes.
Driver for 80 Watts LED street light luminaries , complete all as specified and directed by Engineer-in-Charge. Make : Surya, Bajaj, CG, Philips.
Surge protection device Kit for 80 Watts LED street light luminaries , complete all as specified and directed by Engineer-in-Charge. Make : Bajaj, CG, Philips.
Dismantling unserviceable motor from electrically operated gate of hangers, rewinding and refixing the motor, replacement of unserviceable SWR and Fan Belt, oiling and greasing of all pullies and wheel of the gate, repair of starter and making gates fully operational , complete all as specified and directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead of galvanised iron strip of size 32x6mm fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc , including taking down existing unserviceable galvanised iron strip, complete all as specified and directed by Engineer-in-Charge.
Epoxy base insulators of suitable size 40mm height for fixing GI earth strip on wall/ceiling/floor/poles etc. including taking down existing unserviceable insulators, complete all as specified and directed by Engineer-in-Charge.
Earth continuity conductor or main earthing lead of 25 x 3 mm aluminium strip fixed to wall on insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc , including taking down existing unserviceable aluminium strip, complete all as specified and directed by Engineer-in-Charge.
Air termination, single pointed aluminium rod 12 mm dia and 300 mm long bolted to aluminium strip 25x3 mm , including fixing brackets, clamps made out of steel sections, nuts,bolts and securing of complete system on roof of the building, including taking down existing unserviceable aluminium air termination rod, complete all as specified and directed by Engineer-in-Charge.
Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 32 x 6 mm size by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
PVC insulated & PVC sheathed weather proof multistranded aluminium conducttor cable 2 core of nominal area of conductor 2.5 Sqmm 1100 Volts grade drawn through in GI conduit, pole with MS clamps from Junction box to street light fittting, complete all as specified and directed by Engineer-in-Charge.
Thermoplastic cable junction boxes IP 55/IP 65 with metric knockout for cable entry with terminal of size 333 x 233 x 120 mm on pole with MS clamps, nut bolts, washers and glands suitable for 16 sq mm 04 core cable, complete all as specified and directed by Engineer-in-Charge. Make- Sintax Cat No. gsjb 3020 or equivalant in Neptune.
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 16(R) of tender documents.
AGGARSAIN BUILDERS
SHARMA CONSTRUCATION COMPANY
DASHMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .