| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest quoting | |
| 2 | L2₹34.4 L+₹68,523 (2.03%)Rejected-AOC | L2 | Rejected-AOC Rejected being higher quoting | |
| 3 | L3₹34.8 L+₹1.1 L (3.19%)Rejected-AOC 1542 URBAN ESTATE II HISAR 125 005 HARYANA | HISAR | HARYANA | 125005 | L3 | Rejected-AOC Rejected being higher quoting |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
20 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
Garrison Engineer Hisar Military Station Hisar 125006
CA No GE(H)-36/2022-23 SPL REPAIR TO BLDG NO P 1455 DINING HALL ALL SQN OF CERTAIN UNIT IN THE AOR OF AGE B/R II UNDER GE HISAR AT HISAR MIL STN
2022_MES_546928_1
CA No GE(H)-36/2022-23
Open Tender
Civil Works
Item Rate
210 days
Hisar Mil Stn
As per Tender documents
6 documents required · 6 mandatory
₹500
GE Hisar
₹76,000
Yes
12 Oct 2022
23 Aug 2022
22 Sept 2022
23 Aug 2022
20 Sept 2022
7 Sept 2022
Amount
Demolition of Reincorced cement concrete in any position,Roofs ,beams, chajjas, staircase, landing, roof fascia etc & disposal of rubbish off the premises.
Dismantling of brick tiles or terracing tiles single layer on roofs complete all as specified.
Demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
Taking down chowkat or frame with shutters area not exc 1.5 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) including cutting holes for hold fasts & making good complete all as specified.
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/loose soil all as specified.
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil all as specified.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified.
M&L for PCC 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in filling up chowkat hollows, hold fast, bed block and similar works as directed, complete, all as specified.
M&L for brick work using old size fly ash bricks as specified in clasue 6 of Particular specification, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.
S & F factory made 35mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
S&F factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
S&F 200mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified.
S&F mild steel helical door spring 300mm ordinary rat tail rod pattern spring including roller and roller plate complete all as specified.
S&F 100mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door as directed.
S&F in repairs 20mm bore mild steel powder coated curtain rod with 02 Nos decorative ball type brackets (for each opening) and 02 Nos decorative side stoppers (for each opening) fixed on wall with wooden gutties & screws complete all as specified & as directed.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100mm (SIngle rebated) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125mm (Double rebated) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including box type hinges with steel handle etc complete with glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including making good disturbed surfaces of walls, complete. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Glass pane/wire gauze shall be measured and paid separately.
S&F factory made Steel windows, ISI marked, (Box Type) with side hung shutters including box type hinges with steel handle etc complete without glazing bars dovetailed or welded including one shop coat of Zinc chrome primer including making good disturbed surfaces of walls, complete. Notes:- (i) The rate quoted by the contractor are deemed to be included for one shop coat of red oxide zinc chrome primer on steel windows. Nothing shall extra paid on this account. (ii) Glass pane/wire gauze shall be measured and paid separately.
S&F in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) including shutters with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc, Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws including powder coated 'D' type handle of suitable size, tower bolt of suitable size, suitable size hinges heavy grade complete all as specified & as directed. Note :- Mortice lock, Door closer & Glass panes/wire cloth shall be measured & paid seperately under relevant item of BoQ.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks, cooler stand and similar work including welding conforming to Grade E-165 (Fe 290), complete, all as specified & directed.
M&L for preparation of RCC roof surfaces with wire brush, drying and cleaning to remove all foreign materials and washing with water to remove loose particles, filling the cracks with crack filler and providing 50mm average thick PCC 1:2:4 type B-0 (using 20mm graded stone aggregate) {thickness of PCC 70mm at centre and 30mm at outer edge of roof surface} with maintain the proper roof slope complete all as specified and directed.
M&L for providing 25mm thick polymer modified plaster in ratio 1:10 (1 part of polymer and 10 parts of cement with solid contents not less than 30% over slab and applying priming coat of epoxy primer with resin and hardner with water dilution as per manufacturer instructions, applying 1st coat of solvent based polyurathene liquid membrane not less than 500 micron thick UV stable having SRI value greater than equal to 105 with consumption of 0.61 kg/sqm and applying 2nd coat solvent based polyurathene liquid mambrane not less than 500 micron thick UV stable, having SRI value greater than liquid to 105 with consumption of 0.61 Kg/Sqm over dried 1st coat complete all as specified and directed. Make :- Asian Paints / Pidilite / STP / Sikka Note :- The work of WPT shall be got executed through authorised approved applicator.
Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or equivalent make in Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of SikaTop Armatec®-108 of Sika or equivalent make in Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
M&L for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed.
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed .
M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or equivalent make in Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed .
M&L for providing, fixing shear connector of 16mm dia TOR steel upto 160mm length with Sika anchorfix @-2+Tropical or equivalent make in Fosroc / Thermax as approved by GE, epoxy resin to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer's instructions complete all as specified and directed.
Providing and fixing water tight centering & shuttering and Scaffolding including bolting, strutting, propping etc. including removal of form work from column, beam , slab etc. complete as per site requirement and directed.
Supply and applying a ready to use non shrink, cementitious free flow micro-concrete (<100mm) using Product : SikaRep Microcrete-4 + adequate coarse aggregate, Yield : approx. 17 ltr/bag (30kg) (depending on the size and quantity of coarse aggregate added), Product : Sika Microcrete-4 or equivalent make in Fosroc / Thermax as approved by GE, Product requirements : compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99 complete all as specified and directed.
M&L for providing and application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E-WP of Sika or equivalent make in Fosroc / Thermax as approved by GE, as concrete curing membrance over the applied polymer mortar as temporary curing membrance as per the technical specifications and manufacturer's instructions complete all as specified and directed.
Providing and erecting hydraulic and manual steel props upto full height braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and as directed. Note :- Hydraulic and manual steel props will be required, erected and maintain the interval distance of steel props c/c at site on the basis of site requirement all as directed by Engineer-in-charge.
M&L for grinding, rubbing and mirror finish polishing to existing kota stone/mosaic floors/vertical surafces etc complete by mechanically by using different grits all as specified and directed.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick laid over & including screed bed or bedding layer of 15mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified. Note : - Kota stone shall be of size 550mm x 550mm (minimum) when brought at site.
M&L for machine cut Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar, laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L for 18-20mm thick granite (of any type) work table rubbed and polished) in cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc laid over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified & as directed.
M&L for non skid ceramic jointless tiles (coloured) 1st quality, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic designer & pattern (dark & light shade) jointfree tiles (coloured) premium quality, 450mm x 300mm x 7mm thick, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
Raking out joints/pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc all as specified.
M&L flush pointing to brick walls in cement mortar 1:4 all as specified.
M & L for rendering 10mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for rough cast finish plaster by applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of chalk whiting primer all as specified & as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint over a coat of white wash all as specified & as directed.
M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of chalk whiting primer all as specified & as directed.
M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and applying two coats of cement base paint of approved shade/tint all as specified & as directed.
M&L for preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
S&F 2mm thick Polycarbonate sheet (transparent sheet) in square not exc 0.5 sqm in each pane fixed with oil putty and silicon gel with screws complete all as specified and as directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified.
M&L for preparation of new steel surfaces (already applied with coat of primer) of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint of approved tint on existing primer complete all as specified.
Dismantling old unserviceable PVC water tank capacity 1000 ltr and not exc 2000 ltrs & removal from site etc complete all as specified and directed.
Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S&F Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and as directed.
S&F in repairs Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of 20mm bore.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store.
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store.
M&L for galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
M&L for galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall all as specified and directed.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs 15mm bore angle cock, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F in repairs PVC connection 300 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F in repairs CP grating 100 mm dia (minimum weight 25 gram) complete all as specified and directed.
S&F in repairs 100mm bore cast iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears fixed with cement joints, laid in trenches or in floors or fixed on wall complete all as specified.
S&F 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete with oval access door all as specified & as directed.
S&F 100mm bore CI Bends (any radius) with duck's foot or heel rest all as specified & as directed.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
M&L for point wiring for one light / fan point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'
All as per item No. 80.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 80.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per srl item No. 80.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi strand on independent board including provn of 2.50 Sqmm unsheathed, multi stranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed.
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F LED bulb of capacity 15 W, ISI marked, all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F LED tube light fitting 1x20W/22W, regal batten for LED including ultra bright glass LED Tubelight with very high efficacy, single / double side connection all as specified and directed. Make : Havells Regal batten Cat Part No REGALBATTENT8UPTO1X22WSSBSWH & LED tube rod Cat Part No PHOTONULTRAE2.01213T8SSTL20WLED865SPC of Havells or Surya Cat Part No SLE BT 20 MS for batten & LED tube rod Cat Part No SLE TL-DS 18 PC Reform of Surya or Cat No LTTB4F20WLEDEW BATTEN for batten & LED tube rod Cat No Cat No LT4F20WLEDT8/WDI of C&S or equivalent of makes as mentioned in Appx 'C' list of makes.
S&F in replacement asesthetically designed LED street light fitting 35 Watt system wattage for energy saving having IP 66 degree of protection with minimum system efficiency as >85%, made of pressure die cast aluminum hosing powder coated in graphite grey and heat resistant toughened glass with excellent thermal management LED shold have lens optics and vandal proof prismatic poly carbonate covers for ensuring efficient optics and uniform distribution of light fitting should have operating voltage range of 120-270 Volts, THD<10%, P.F. >0.95, fitting should have in built surge protector of 5 KV and CRI>70 with CCT 5700 K and including 0.5 sqmm flexible copper multistranded conductor cable fixed on wall / pole including security light bracket made to shape out of GI pipe 40mm dia light grade 1.5m length and fixed with MS clamps of size 40x5mm - 2 Nos, nuts, bolts and washers fixed on wall all as specified and directed. Make : Cat Part No ENDURACITYLITEPLATPLUSSL35WLED757SASYBOPC of Endura Citylite Platinum Plus of Havells or TRP-400-35-57-SL-LM-NSR of Crompton or equivalent make as mentioned in Appx 'C' list of makes here-in-after.
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. Make :- Indo Asian Cat Part No 810321 or equivalent of makes mentioned in list of makes here-in-after .
S & F MCB SP, 6 to 32 Amps 240 Volts , 'B' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F MCB SPN, 40 Amps 240 Volts , 'B' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S & F 4 Pole MCB TPN, 63 Amps 240 Volts , 'B' curve, 16 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F in replacement sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs conforming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Indo Asian Cat Part No 810336 or equivalent of makes mentioned in list of makes here-in-after .
Supply and fixing one star rated energy saving ceiling fan 1200mm sweep as per alest IS-374-2019 having service value > 4 to < 4.5 m3/min/w and 50 watt with double ball bearing and three blades with all accessories, down rod, two nos canopy, white in colour including 2 core 0.5 sqmm copper flexible cable for connection from ceiling rose to fan complete all as specified and directed.
Supply & fixing and testing metal body exhaust fan of 380mm sweep heavy duty, double ball bearing, 900 RPM, suitable for SP 230 / 250 volt, 50 Hz AC supply complete with louver shutter including fixing / grouting of frame in wall & cutting opening complete with covers & connecting with & including 3 Nos 1.5 sqmm single core, PVC insulated but unsheathed FRLS 1100 volts grade cable with multi-stranded copper conductor from ceiling rose to fan complete. Make : Model No Turbojet SP of Havells or Cat Part No Supreme DLX HD of Bajaj or Cat No Transair of Crompton equivalent of make as mentioned in Appx 'C' list of makes here-in-after.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
Supply , laying , jointing, testing and commissioning of cable of size 35 sqmm 3.5 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors as per IS 7098 (Part-I), laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe including taking out existing u/s cable complete all as specified. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness afterlaying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
M & L for earthing complete with galvanized iron earth plate electrode of size 60cmx60cmx6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized earth lead wire 4mm dia by means of GI bolts/nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top, 20mm GI medium grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
moti construction company
m/s krishna engineers1
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .