Providing and Fixing of Contractor Block Overload Relay Single Phase Preventor Timer at various Pumping Installation in Sector 1 Panchkula.
2026_HBC_500750_1
2025D16D9629 C8DE 4956 8181 47DBEB225436269HSV
Open Tender
Civil Works
30 days
Panchkula
Please refer Tender documents.
2 documents required · 2 mandatory
₹250
Yes
₹3,380
Yes
25 Feb 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
12 Feb 2026
4 Feb 2026
4 Feb 2026 - 12 Feb 2026
23.22.1.5:- Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA
20.114.9:- Supplying erection, testing of fully automatic electric control panel board for T/Wells in Pump Chamber consisting of MS sheet of thickness 14 gauge duly painted box type floor mounted made of angle Frame containing 1 no. fully automatic air brake starter suitable for Motor of the following capacity, Min switch of suitable range with HRC fuse, 1 no. volt meter (0 to 500 volts), 1 No. Amp. Meter of 0 to 100 amp. 3 sets of indicating lamp capacitor of suitable capacity and 1 no. single phase preventers with the timer switch including wiring in panel board and suitable electric energy meter wiring in Electric Control Panel Board complete in all respect as per specification given in Schedule No. II, Including MCB, suitable, Capacitor, Wooden Box etc as per site requirement complete in all respect. 9. 50 HP Motor [Through Rate]
NS Item:- Providing and Fixing of Kit Kat 500 ampere ASCO make
NS Item:- Providing & Fixing of Overload Relay MN12 CT Operated 60-100 Amp. L&T make satisfaction of Engineer-in-Charge & attesting on load.
App. Item:- Providing and Fixing of Contractor Block MNX 80 LandT Make as Per Satisfaction of Engineer-in-Charge and attesting on load
NS Item:- Providing & Fixing of Copper wire multistand 35 sq mm
NS Item:- Providing and Fixing of Single phase preventor LandT/Minilac make as per satisfaction of Engineer-in- charge and attesting on load to the entire satisfaction of EIC.
NS Item:- PF of Electrical CT Meter Box size 43” length 16” width and 8” depth (heavy duty) shockproof and rustproof cable entry from bottom and or side 100% waterproof pole mounting arrangement tamper proof mtc. free fire retardant class FV-0 as per IS:11731 Part- II or V-0 as per UL-94 High heat distoration (200C as per IS:10192) with angle fasner nut bolt and site fitting complete in all respect to the entire satisfaction of EIC.
NS Item:- PF of Current Transformer (CT) 100/5 energy meter ratio 100/5 frequent 50 Hz burden 5 VA 0.5 accuracy make Concard / Vishal / Jai Durga / Secure including testing fees etc. complete in all respect to the entire satisfaction of EIC.
NS Item:- Providing and Fixing of SPPR type SDz5 Timer 415 volt make LandT complete in all respect to the entire satisfaction of EIC and attesting on load.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
BOQ_579360.xls
BOQ • 0.25 MB
AD0146228.pdf
Additional Documents • 3.26 MB
OT0146228.pdf
Other Document • 0.09 MB
Download all tender documents and submit your bid