| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.0 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to lowest tenderer | |
| 2 | L-2₹7.6 L+₹1.5 L (24.4%)Rejected-Finance | L-2 | Rejected-Finance Not being L1 | |
| 3 | L-3₹8.4 L+₹2.3 L (38.3%)Rejected-Finance | L-3 | Rejected-Finance Not being L1 | |
| 4 | L-4₹8.5 L+₹2.4 L (39.9%)Rejected-Finance | L-4 | Rejected-Finance Not being L1 | |
| 5 | L-5₹8.6 L+₹2.5 L (41.8%)Rejected-Finance | L-5 | Rejected-Finance Not being L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
29 Oct 2022, 6:00 pmClosed
AGE (I) Niwaru
AGE (I) Niwaru
AGE(I)N 25 OF 2022-23 REPAIR TO PLASTER TILES GI AND SANITARY FITTINGS IN ORS MD ACCNS AT NIWARU MIL STATION JAIPUR UNDER AGE (I) NIWARU
2022_MES_555416_1
AGE (I)/N-25 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Niwaru
CLASS E
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹20,000
Yes
10 Nov 2022
30 Sept 2022
1 Nov 2022
30 Sept 2022
29 Oct 2022
14 Oct 2022
Amount
Demolition floor, hearth or wall tiling including cement mortar bedding,(but not backing) and rubbish off the premises , complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15mm thick in CM 1:4 with water proofing compund on fair faces of brick on concrete slab & sides of sunken portion, finished even and smooth w/o using extra cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound (ISI marked), complete all as specified and directed by Engineer-in-Charge.
M & L for priming surfaces and applying normal treatment (for moderate conditiion) using glass fibre bore bituman felt grade 2, complete all as specified and directed by Engineer-in-Charge.
M & L for applying evently a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces, complete all as specified and directed by Engineer-in-Charge.
M & L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application , complete all as specified and directed by Engineer-in-Charge. Note : The roof treatment shall be executed through approved manufacturer only.
M & L for PCC 1:5:10 type E2 (using 40mm graded stone aggregate) as in, foundation filing and mass concrete. bed blocks, coping, lintels upto 1.5m span and similar work complete , complete all as specified and directed by Engineer-in-Charge.
M&L Non skid light coloured ceramic tiles 7 to 8mm thick (Square/Rectangular) area of each tiles exc. 0.06 sqm but not exc. 0.11 sqm, in floors etc,confirming to IS: 15622 : 2006 grade B II (a) matt superior finish flooring, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15 mm thick in CM 1:6 as bedding layer for floor finishes complete all as specified and as directed.
All as per item No 09 above, but on vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl backing coat of in CM 1:4 10mm thick complete all as specified and as directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed by Engineer-in-Charge.
M&L rendering 10 mm thick in CM(1:6) on brick walls or concrete surface, surface finished even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying two coats of Acrylic washable distemper of approved shade/tint over a coat of primer on walls , complete all as specified and directed by Engineer-in-Charge.
M&L for 3mm thick wall care putty on wall , complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces and applying two coats of Acrylic washable distemper of approved shade/tint over a coat of primer on walls , complete all as specified and directed by Engineer-in-Charge.
M&L rendering 5 mm thick in CM(1:3) on ceiling, surface finished even and smooth without using extra cement , complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces and applying three coats of white wash on alkali-resistant priming paint on ceiling , complete all as specified and directed by Engineer-in-Charge.
Dismantling for 500 ltr water storage tank, complete all as specified and directed by Engineer-in-Charge.
S&F 500 ltr Rotational moulded three layer polye?thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel water tubing and connections of following descriptions, complete all as specified and directed by Engineer-in-Charge. :-
(a) 15 mm bore
(b) 20 mm bore
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of following descriptions, complete all as specified and directed by Engineer-in-Charge. :-
(a) 15 mm bore
(b) 20 mm bore
All as per the description of item No.21 here in before but re-fixing old steel tubing of following descriptions , complete all as specified and directed by Engineer-in-Charge.:- (a) 20 mm bore
S&F in repair vitreous china wash down water closet pan (padestal)white including connection to drain (or outgoing pipe),flushing pipe,anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device , complete all as specified and directed by Engineer-in-Charge.
S&F in repair Flushing cistern with inlet ball valve float and handle incl bracket 10 Lit capacity with flush pipe of polythene of low or high density or PVC 32 mm dia fixed etc., complete all as specified and directed by Engineer-in-Charge.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm fancy type Bib taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm Two way taps, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm angle valve, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F in repair 32 mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed
S&F in repair 15mm dia Brass CP Pillar tap mixer for mixing hot & cold water screwed down for iron pipe and fixed for WHB , complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stop valves suitable for pipe 15mm bore cast copper alloy fancy type, chromium plated with long shank and cup (concealed type), screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous China wash hand basin flat back , white coloured, size 550x400mm including CP waste coupling, Bracket but excluding taps, waste chain & plug , complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm Chrome Plated wall mixer 3-in-1 with provision for overhead shower with 115 mm long bend pipe with chrom finish , complete all as specified and directed by Engineer-in-Charge.
S&F in repair Brass chromium plated shower rose 125mm size, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube andABS wall hook including making connections and fixed in position , complete all as specified and directed by Engineer-in-Charge.
S&F in repair Chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 15 mm size with PTMT nuts 600 mm long, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) gully trap 100/150 mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
S&F in repair UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, Type 'B', ISI marked of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F in repair UPVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, Type 'B', ISI marked of 75 mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F in repair UPVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls, Type 'B', ISI marked of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
S & F in repair 110 mm PVC (SWR) bends any radius with access door, complete all as specified and directed by Engineer-in-Charge.
S&F in repair 110 mm dia PVC (SWR) branch piece, single (single Y) equal or unequal with access door, complete all as specified and directed by Engineer-in-Charge.
S & F in repair 110 mm PVC (SWR), junction single, (Single T) equal or unequal with acess door, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC (SWR) reducers (110x75 mm), complete all as specified and directed by Engineer-in-Charge.
Dismantling loose concrete cover of RCC columns,beams,slabs,Chajjas and the like as IN PATCH WORK OF AREA nexc 2.5 sqm nature at different qtrs as directed ,roughening and cleaning concrete surfaces with steel wire brushes,washed with water and allowed to dry,including dusting of steel reinforcement,providing fabric mild steel wire mesh 75 mm x 75 mm of 2 mm dia as reinforcement to concrete surfaces,applying adhesive/admixyure over steel mesh and providing 25 mm thick (average thickness) guniting mix using 1 part of ordinary portland cement 53 grade and 2 parts of banas sand mixed with adhesive/admixture at the rate as per manufactures instruction or 2% by wt of cement all as directed with apressure of 2 to 2.5 kgs per sqm by guniting machine including necessary padding,steel scaffolding and shuttering for working platform/formwork , complete all as specified and directed by Engineer-in-Charge.
S&F for 32 mm Mild steel galvanized steel tubing medium grade as spout to sunken floor with all fittings fixed in repair, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces and applying three coats of white wash on ceiling , complete all as specified and directed by Engineer-in-Charge.
M/S JALANDRA CONSTRUCTIONS
J.J.ENGINEERING
RAMJI LAL & SONS
C.P.Computers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .