| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC | ₹30.7 L Quoted ₹31.3 L | L1 | Accepted-AOC L1 Accepted |
| 2 | L2₹34.5 L+₹3.2 L (10.3%)Rejected-AOC | ₹34.5 L+₹3.2 L (10.3%) | L2 | Rejected-AOC Other than L1 |
| 3 | L3₹34.8 L+₹3.5 L (11.4%)Rejected-AOC 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | ₹34.8 L+₹3.5 L (11.4%) | L3 | Rejected-AOC Other than L1 |
| 4 | L4₹38.9 L+₹7.7 L (24.6%)Rejected-AOC | ₹38.9 L+₹7.7 L (24.6%) | L4 | Rejected-AOC Other than L1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
4 Aug 2023, 6:00 pmClosed
Garrison Engineer
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
PERIODICAL SERVICES INCLUDING REPAIR TO PLASTERING, JOINERY, PLUMBING, SANITARY FITTING, ROOFING, FLOORING ETC AT SOUTHERN GARRISON AT SUNDERBANI UNDER GE (NORTH) AKHNOOR
2023_MES_607215_1
CANO- GE(N)/AKH-39/2023-2024
Open Tender
Support/Maintenance Service
Item Rate
180 days
Sunderbani
Class D category a(i)
9 documents required · 9 mandatory
₹500
GE (N) Akhnoor
₹86,000
Yes
19 Oct 2023
30 Jun 2023
11 Aug 2023
30 Jun 2023
4 Aug 2023
21 Jul 2023
Amount
Dismantling plain or corrugated steel sheeting, any guage, thickness as in roof covering etc as specified.
Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as directed.
M&L Pre-painted galvalume aluminium zinc coating GI based plain steel piece adjustable unserrated ridge , hips,or in Eaves board and fixed with L hook or cranked bolts complete all as specified and directed.
M&L for dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets GI framework and fixing in same position in repairs all as specified and directed.
Dismantling wall and ceiling boards ( fibre ,pulp, insulation,etc,) or insulation boards/slabs/blankets any thickness,including ceiling framework all as specified and directed.
GI frame work with size of grid 605 x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 centre to centre with support of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and including 4mm thick Non asbestos fibre cement designer type building board fixed or laid/inserted to GI/Aluminium framework with screws complete all as specified and directed.
M&L for Non asbestos fibre cement building boards 4mm thick fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in repairs all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches , pillars etc.
M&L Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 all as specified and directed.
M&L for walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 complete all as specified and directed.
M&L for walling of random rubble uncoursed, well bonded, bedded and solidly hearted built in CM 1:4 but except stones all as specified and directed.
Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc.
M&L for rendering 15mm thick cement plaster with cement mortar(1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement all as specified and directed.
M&L for rendering 10 mm thick cement plaster with cement mortar(1:6)on other than fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement all as specified and directed.
M & L Preparatrion of new treated surfaces and apply two coat of oil bound distemper to walls over one coat of chalk whiting complete all as speicfied and directed.
M & L Preparatrion of old plastered surfaces of walls and applying two coats of oil bound distemper all as speicfied and directed.
M & L Preparatrion of new plastered and unplastered surfaces of walls and applying two coat of cement based paint over priming plastered and other surfaces with alkali resistant priming paint all as speicfied and directed.
M & L Preparatrion of old plastered surfaces of walls and applying two coats of cement based paint all as speicfied and directed.
M& L for Complete removal of existing treatment and preparation of old surfaces and applying two coats of oil bound distemper over priming plastered on ceiling all as specified and directed.
M&L for preparation of old steel (as in roof sheets, steel window, door, railings, gratings etc) and iron surfaces over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint all as specified and directed.
M&L for preparation of old steel and iron surfaces of any description, over 10 Cm in width or girth, not otherwise described and painting with one coats of synthetic enamel paint as camouflage pattern on roof sheets all as specified and directed.
M&L for preparation of new untreated wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and painting with one coat of synthetic enamel paint all as specified and directed.
S&F rolled mild steel section as in main and cross beams, hip and jack,rafters, purlins, where connected to common, rafters and running rails and guiders for sliding doors: fixed with angle cleats or other connecting plates conforming to grade Fe410-W (Gde E-250) quality 'A'all as specified and directed.
S&F gusset plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk foring holes, without any attachement all as specified and directed.
S&F mild steel joist channel angle or tee sections fixed independently without connected plates etc of grade fe-410-0 or fe-310-0 all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demoltion complete all as specified and directed.
S & F mild steel bars 10mm dia TMT Bars and over cut to length bent to shape required including cranking, bending sprially for hopping for columns, hooking ends and binding with and includig mild steel wire not less than 0.9mm dia or securing with clips complete fixed in repairs all as specified and directed.
M&L Reinforced cement concrete (nominal mix) type B-1, 1:2:4 (20 mm graded crushed stone aggregatge) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and directed.
M & L Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Vertical , Horizontal or sloping)sides including sup- ports, overhangs, for fair finished surface of concrete etc. complete all as specified and directed.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) ,removing serviceable tiles to store and rubbish off the premises all as specified and directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub floor under tiles, all as specified and directed.
M&L for Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
-Ditto- all as per item no. 35 here-in-before but ceremic coloured tiles as in skirting as directed.
M&L Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. Set and jointed in neat cement slurry and pointed in coloured cement to match including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
M&L Ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm as in skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the surface complete all as specified and directed.
M&L Ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 sqm as in skirting, set and jointed neat cement to match the surface complete all as specified and directed.
M&L Glazed ceramic tile 450 x 350 x 06-7mm thick (coloured) on vertical surfaces such as dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) exc 1.50 m and n.exc 4.00 Sqm each complete all as specified and directed.
Taking down chowkhat or frames of door/ window with shutters (Without taking off shutter from the frame) nexc 1.50 sqm complete all as specified and directed.
M & L Pressed steel frames of sizes 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar and filling hollow of frame ,all as specified and directed.
Pressed steel frames of sizes 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates complete including one shop coat of red oxide primer, providing mild steel 6 mm dia threshold bar and filling hollow of frame,all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as a gap insert for top rail and bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S frame welded / sealed to the stiles and nails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at side as per specification and drawings.
Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing.
M&L For PCC 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate) as in filling of pressed steel frame.and including 50 mm parapet coping all as specified and directed by Engineer-in- Charge.
M&L For PCC 1:3:6 type C-1 (Using 20mm graded crushed stone aggregate) for hold fast blocks, including necessary form work for rough finished surfaces etc complete all as specified and as directed.
S & F 35 mm thick Flush shutters, solid core with particle board exterior grade as per IS-2202 of 199 (Part-I). Flush door shutter shall be internally lipped as per clause 8.52.2 of SSR-2009 Part-I complete all as specified and directed.
S&F Glazed and skelton shutters 30 mm thick second class hard wood, opened rebated and prepared to receive wire mesh etc, edge of framing plain, chamfered or rounded, fitted with cut and mitred beads for sucuring witre mesh etc. Size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.24(a).
S&F Mild steel springs for doors, 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 100 mm butt hinges, medium weight cold rolled mild steel all as specified and directed.
S&F Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt 150 mm, extruded section all as specified and directed.
S& F Hasp and stapple safety type of aluminium anodised 100 mm long as in cupboard locker all as specified and directed.
S&F 75 mm butt hinges, medium weight cold rolled mild steel all as specified and directed.
S& F aluminium anodised sliding door bolts round nuckle with hasp and stapple extruded section or cast aluminium alloy 300 mm long complete all as specified and directed.
S & F Steel window/ventilator (Box type) factory made with double shutter (wire gauged shutter and glass/glazed shutter, wire cloth and glass paned shall be measured and paid separately of size 79mm x 39 mm, 16 guage rectangular tubular frame with side hung. fixed in repairs complete all as specified and as per drawing No CEUZ/TD/1269/2008 Sheet 1/1 to 1/3.
-Ditto- All as per item No 58 above but W/O glazing bar.
S&F Galvanised steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed all as specified and directed.
S&F Floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,nodised,with hard drawn steel spring,fixed in bottom body of door complete all as specified and directed.
M&L 19mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as cupboard shelve and shutter all as specified and directed.
M&L 12mm thick Pre-laminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame in repairs as in kitchen cupboard and bottom shelf of cooking platform complete all as specified and directed.
Demolition of concrete in ground floor and paving n.exc 15cm thickness (below or above ground level complete all as specified and directed.
Providing cement concrete type C-1, 1:3:6 ( using 20mm graded stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair on top without using extra cement with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and directed.
Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) three layered hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified and directed.
Taking up or down steel water tubing and connections of bore 20mm complete all as directed.
Taking up or down steel water tubing and connections of bore15 mm complete all as directed.
Fixing only 15mm bore steel tubing any grade to walls and ceilings .
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of bore 20 mm all as specified and directed.
Mild steel galvanized steel tubing medium grade with all fittings and fixed complete to walls and ceiling or laid in floors complete of bore15 mm all as specified and directed.
Fixing only 20 mm bore steel tubing any grade to walls and ceilings .
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth Stone concrete block or slab walls all as directed.
S&F Stop valves cast copper alloy serwed down high pressure ,with crutch or butterfly handle screwed both ends for iron pipe for 15mm dia of pipe fixed in repairs all as specified and directed.
S&F Stop valves cast copper alloy serwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe for 20mm dia of pipe fixed in repairs all as specified and directed.
S&F ball valve high pressure PTMT with epoxy coated aluminium rod & high density plastic ball 20mm dia bore all as specified and directed.
PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections fixed in repairs complete all as specified and directed.
Vitreous china squatting pan "Orissa Pattern" size 580 x 440 mm in white colour with integral foot rest incl lime mortor, 'S' trap fixed in repairs complete all as specified and directed. Cat Part No-20042 (ORISSA PAN (ECO)) of Hindware or equivalent cat part of make specified in list make as approved by GE.
S&F PVC connection 15 mm size with PTMT nuts 450 mm long.
Taking down eaves gutters and rain water pipe , soil and waste pipe (any size or pattern ), includding all fittings, heads , shoes bends , swan-necks etc all as specified and directed.
S & F 110mm bore PVC SWR Type-B pipes single socket in any length with rubber joints fixed in floors etc all as specified and directed.
S & F PVC (SWR) pipes 110mm dia single socketed in any length fixed to walls with PVC/MS holder and clamps complete all as specified and directed.
-Ditto- All as per Srl No 82 here-in-before, but 75mm bore.
S & F in repair PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs,washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm as approved by Engr-in-Charge complete all as specified and directed.
S & F in repair CP angle valve/concealed stop cock (weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2)of cast copper alloy (ISI Marked) chromium plated fancy type screwed down high pressure with capstain head screwed both ends for iron pipe 15mm bore complete all as specified and directed.
S & F in repair 15 mm CP Bib taps (Long body and weight not less than 0.40Kg as mentioned in SSR part- 1 clause no. 18.14.2) , fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair CP Brass wall mixer for mixing hot cold water supply screwed down incl connecting legs & wall flanges for iron pipe 15mm dia bore fancy type complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement all as specified and directed.
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required complete all as specified and directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ractangular) area of each tiles exceeding 0.06 Sqm but n.exceeding 0.11sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement incl 15mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes.to match the surface complete all as specified and directed.
Taking down shutters of any dscription exc 1 sqm but n.exc 2 sqm each all as specified and directed.
Refixing shutters in the same opening of any description exc 1 sqm and nexc 2 Sqm each all as specified and directed.
S&F Aluminium door air tight of anodised frame made of size 100mmx45mm of section thickness 1.50mm thick with one or rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two Nos of panels on each shutter) with 5.5mm thick tinted glass shutter rail made of 80mmx45mm of sheet thickness 1.50mm thick (Top, bottom, middle and side rail) single/double leaf side hinge type including necessary jointing /aluminium fillets/glazing bars with rubber gasket with aluminium fillets such as bottom door hydraulic door closer-01 No, aluminium tower bolt 150mm long 01No , aluminium anodised bow handles 300m 02 Nos fancy type on each shutter mortice locks 6 lever Make-harrison, one on each door, bottom and floor stoppers, all fitting shall be of ISI marked except cleats) sizes of each door shall be as per site requirement all as directed and specified.
S&F Aluminium window air tight with glazing bar, with aluminium grills (oranmental type) window shutter style shall be 40mmx19mm, sheet thickness 1.5mm sliding channel 3mm thick of width as required and as directed by Engr-in-Charge of anodised frame made of size 75mmx40mm of section thickness 1.50mm thick, with or without rebate with toughned glass 5mm thick, including rubber beading and gasket and aluminium glazing clips, locking arrangement, aluminium anodised bow handles 75mm 01 No complete all as specified. Note :- All fitting shall be of ISI marked except cleats) sizes of each shutter shall be as per site requirement all as directed and specified.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified.
S&F 3mm thick figured glass, pin head type and glazing with oil putty or wooden beads in squares in exc 0.5 sq.m in each pane all as specified and directed.
S&F mild steel cold rolled parliament hinges 100 mm long with screws complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc all as spd & directed.
M&L for brushing cleaned surface with neat cement slurry with 3.0Kg of cement per sqm all as spd and directed.
M &L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in roof padding in slop, finished surface even and smooth without using extra cement, complete all as specified and directed.
Water proofing treatment to RCC roof slab including parapet as under :- (a) Ist Course : Apply a coat of bituminous primer conforming to IS-3384@ 0.40 Kg /Sqm on prepared surface of plaster and after drying of primer, apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm on plastered surfaces. (b) 2nd Course : APP (Atactic Polypropylene) modified polymeric membrane, 5 layered, 3 mm thick weight not less than 3.0 Kg/Sqm with 160 Grams/Sqm non woven polyester made at centre core reinforced laid with 75 mm side overlap and 150 mm end overlap, membrane has to be laid with LPG torch and overlap sealed and finished neat, all joints and changes in direction should be covered with cement mortar 1:3 mixed with SBR latex @200ml/bag of cement and curved before laying of membarance. (c) 3rd Course : Apply a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.2 Kg/sqm over membrance and dusted with dry sand @ 0.50 to 1 Kg/sqm. The water proofing treatment shall be got carried out from the authorised personal of the Company all as specified and directed.
S&FPVC wall lining/panelling consisting of 5mm thick plain colour pvc sheet inclusive of solvent cement and fixing at site on pvc frame including 5mm thick pvc sheet filet of width 35mm to make pvc frame all as per manufacturers instruction and drawings all as directed.
S&F Steel rolling shutters of 01 mm thick laths, with ball bearing gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple erected in position as indicated fixed as in repair, complete all as specified and directed.
S&F Safety lever locks mild steel with 4 levers for rolling shutters fixed , complete all as specified and directed.
S&F Ball bearing for rolling shutters, fixed in repairs, complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as directed.
Supply only Integral waterproofing compound.
M&L Rendering 10mm thick on brick or concrete surface as in chajja/facia in cement mortar 1:3 finished even and smooth without using extra cement all as specified and directed.
M&L for preparation of old painted surfaces by applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance,dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and directed.
-Ditto- All as per item no. 111 here-in-before but including priming coat of exterior primer applied @ 0.90 ltr/10 Sqm over on new surfaces all as specified and directed.
Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work not exceeding 200mm thick surface horizontal or sloping, fair finished surface of concrete, all as specified and directed.
M&L for preparation and brooming down of old decorated plastered or unplastered surfaces of walls including cornice etc and applying one coat of white wash on walls complete all as specified and directed.
-Ditto- all as per item 114 here-in-before but on ceiling.
M&L for washing, rubbing down and stopping of old distempered surfaces and applying two coat of distemper oil emulsion to walls complete all as specified and directed.
-Ditto- all as per item 116 here-in-before but two coats on walls over one coat of wall care putty.
M&L for preparation of old painted wall surfaces and applying one coat of cement base paint to walls complete all as specified and directed.
TMT Bars , 6 to 8mm dia over cut to length , bent to shape reqd including cranking bending and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth (roof sheets) not otherwise described and applying two coats of synthetic enamel paint in camouflage pattern complete all as speciified and directed.
M&L for preparation new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as speciified and directed.
KANWAL KUMAR GUPTA
NATIONAL TRADING COMPANY
M/s Mool Raj Romesh Chander
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .