Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹48.7 L
EMD Value
₹97,380
Closing Date
31 Mar 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Projects Div. JMC
Town Hall, JMC
Construction of Entry Gate way on road leading to Hari Market, Jammu
2023_HAUDD_208155_4
e-NIT No 94(P) of 2022-23 of Projects Div. JMC
Open Tender
Civil Works
Item Rate
180 days
Jammu
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer, Projects Div. JMC
₹97,380
Yes
5 Apr 2023
15 Mar 2023
1 Apr 2023
15 Mar 2023
31 Mar 2023
15 Mar 2023
Amount
Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material upto a lead of 1 kilometer, as per direction of Engineer-in-charge.
Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix)
Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works above plinth level upto floor V level.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, abutments, posts and struts.
Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platforms.
Centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls Under 20 cm wide
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and de-centering at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). Suspended floors, roofs, landings, beams and balconies (plan area to be measured)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge for Granite Work.
Providing and fixing machine cut, mirror / egg shell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. All complete as per Architectural drawings, and as directed by the Engineer- in-Charge. a. 18 mm thick Italian Marble stone slab, Perlato, Rosso Verona, Fire Red or Dark Emperadore etc.
Extra for providing Jali Work on exisiting wall lining in cuttings or specific areas as per the directions and design approved by the Engineer-in-Charge Complete with carriage and fitting charges complete. Jali work is to be done to existing Marble/Stone work in floral/geometric patterns as directed by the EIC, through laser/CNC cutting to the satisfaction of EIC. The cut surfaces are to be moulded and sanded to get rid of the sharp edges. No wastsges shall be paid extra to the contractor on this item. The measurement shall be done of the Visible Jali Area as whole
15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 4 ( 1 cement : 4 coarse sand)
Extra for plastering done on moulding cornices or architraves including neat finish to line and level : In one coat
Extra for plastering Groined ceiling
Extra for Carving on Plaster including fastening to the surface by providing skin reinforcement as required and painitng the same as directed by the Engineer-In-Charge. The cost is inclusive of applying neccessary tools for carving various floral/geometric/pattern shapes as approved in the design. Also included in the cost is framing and clamping any neccessary art objects like decorative stone, stencils etc to the carved surface. the entire surface is to be painted in exterior grade oil paints or equivalent as per details already approved in two or more layers to provide matching shades. the oil paint sueface is to be laquered for even shine. The work is to be executed by trained artisan in the field.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.The payment of this item shall be made as per actual work executed at site and should be supported with geo tagged photographs
Providing and fixing logos as per approved design and concept. The logos shall be made with 4-6 mm thick exterior grade acrylic backing screwed to the surface with self tapping screws.The backing shall be cut in any shape as approved by the Engineer-in-Charge and also have provision for receiving wiring and recess for LED lighting. The main logo shall be affixed on top with the help of firm and stich locks. The design whatever approved shall be printed on top of the front cover in colors as approved by the Engineer-in-Charge. The entire assembly shall be of minimum size 600 x 600 mm and be properly connected to a 2x2.5 + 1x1.5 Sqmm circuit. No extra shall be paid on account of Scaffolding or any other platform structure.
Supply, Installation, Testing and Commissioning of outdoor type flood light of 150 Watt or more of color and make as approved by the Engineer-in-charge with necessary connections and tuning. The lights are to be enclosed in MS enclosures fixed to PCC base (PCC base to be paid separately) by means of suitable fasteners (Nuts & Bolts) as approved by the Engineer-in-charge. The cost also includes necessary connections to an automated panel (To be paid separately) all items included (Complete Job) as approved by the Engineer-in-Charge.
Supply, Installation, Testing and Commissioning of Main Switch Cum-Padestal- cum- Distribution board. Time light distribution board 65 amp 3 pole / 230 Volts with digital time switch having suitable size of 2 no. 63 amp TPN MCB, 2 no. 65 amp contactor Astronomical Type, 1 HRC fuse, 1 No. Rotray Switch, 1 No. 16 amp fuse base, 1 No. Timer switch and 1 Indicator having IP 52/56 Degree protection all items should be of same make / manufacturer including padestal, including making connection and petty material required to complete the job in all respect upto the entire satisfaction of Engineer-in Charge of the work. (Reputed Make).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 10 sq mm Aluminium
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. Mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 2 X 10 sq. mm (19mm) .
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing, fixing and installing of 18W LED Strip Light Upto 5 Meter roll, from system 2700K colour temperature, maximum system wattage of 18W , useful life of 50000 Hrs (Complete LM 80 test report for LED should be submitted) , isolated type, multistage Constant Current Constant Voltage topology driver suitable to operate in input voltage range of 150V to 270V ( nominal rated voltage – 240V) with minimum 2KV surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less that 10% should be integral to the luminaire complete with all accessories required with lamps.Philips/ Wipro/ Tisva. The rate quoted is for inclusive of wiring of 2x1.5 sqmm, modular switch, modular plate, modular box etc all complete fittings for switching on and off of the fixture. Each fixtures to be controlled by 1 no. 5 amp. Switch
Providing and fixing Backlit Sign Board as per approved design and concept. The Signboard shall be made with 4-6 mm thick exterior grade acrylic backing screwed to the surface with self tapping screws.The backing shall be provided with height adjustable steel suspenders with height adjustment by screw rotation as approved by the Engineer-in-Charge and also have provision for receiving wiring and recess for LED lighting. The Writing whatever approved shall be printed on top of the front cover in colors as approved by the Engineer-in-Charge with exterior grade ACP Letters embossed to a minimum thickness of 20mm. The entire assembly shall be of minimum size 7000 x 600 mm and be properly connected to a 2x2.5 + 1x1 Sqmm circuit. No extra shall be paid on account of Scaffolding or any other platform structure.
Providing detailed Actual Architectural Drawings and Structural Design/Drawings duly vetted by a Competent Authority including Soil bearing tests Standard Penetration Tests sa per IS Specifications. The cost includes performing all tests, design costs, vetting costs. The design Shall be vetted from DIQC Jammu, IIT Jammu, NIT Srinagar or equivalent institute. Designs shall done in accordance to the concept approved by JMC.
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Carriage of material by Mech.Transport from source to site of work a) Sand for 08 kms
b) Bajree for 08 Kms
c) Bricks for 15 Kms
RAHUL GUPTA
SURINDER PAL SINGH
AKHIL GUPTA
RAKESH KUMAR GUPTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .