Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC GOTKHINDI SANGLI | ₹1.5 Cr | L1 | Accepted-AOC Accept |
| 2 | L2₹1.6 Cr+₹7.4 L (4.94%)Rejected-Finance SANGLI | MAHARASHTRA | 415409 | ₹1.6 Cr+₹7.4 L (4.94%) | L2 | Rejected-Finance Not responsive bidder |
| 3 | NA₹1.1 CrRejected-Finance H NO 357 A P SUNDI TAL CHANDGAD DIST KOLHAPUR MAHARASHTRA INDIA PIN 416507 | KOLHAPUR | MAHARASHTRA | 416507 | ₹1.1 Cr | NA | Rejected-Finance Not responsive bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Not qualified |
Tender Value
₹1.5 Cr
Closing Date
12 Apr 2024, 2:00 pmClosed
Mr. Tukaram Kamble
Son Pandhar Sundi Agro Producer Company Pvt. Ltd. At-Sundi, Tal-Chandgad Dist-Kolhapur
Construction of Processing Unit of Son Pandhar Sundi Agro Producer Company Pvt. Ltd. At Sundi, Tal Chandgad Dist Kolhapur
2024_DOAWB_1032676_1
SMART/KOP/SNP/WORKS/03/2024
Open Tender
Civil Works
Item Rate
183 days
Gat No 683 at Sundi
As Metioned in Bid Document
4 documents required · 4 mandatory
₹1,000
Exempted
Online at SMART DIU Kolhapur
5 Dec 2024
16 Mar 2024
15 Apr 2024
16 Mar 2024
12 Apr 2024
16 Mar 2024
16 Mar 2024 - 22 Mar 2024
22 Mar 2024
Amount
Civil Portion
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting including all leads and lift etc.complete.
Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Manual
Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro including all leads and lift etc.complete.
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lift etc.complete.
Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lift etc.complete.
Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap metal for reinforced cement concrete plinth beams as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lift etc.complete.
Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied including all leads and lift etc.complete.
Filling in plinth and floors with contractors material / brought from outside and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, including all leads and lift etc.complete.
Filling in plinth and floors with isite material and approved by Engineer In-Charge, in 15 centimetre to 20 centimetre layers including watering and compaction, including all leads and lift etc.complete.
Providing dry trap/ granite/ quartzite/ gneiss rubble stone soiling 15 centimetre to 20 centimetre thick including hand packing and compacting, including all leads and lift etc.complete.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, including all leads and lift etc.complete.
Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in superstructure of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, including all leads and lift etc.complete.
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, including all leads and lift etc.complete.
Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 to rout cast tratment or brick surfaces, in all positions including scaffolding and curing, including all leads and lift etc.complete.
Providing and laying ceramic tiles of having sizes 1414.90 One 975171.72 Square 30 centimetre X 30 centimetre and confirming to Square Metre corrosponding Indian standared for dado and Metre skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including jointfilling with white/colour cement slurry, cleanding, curing,ncluding all leads and lift etc.complete.
Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of three tracks with rectangular pipe having overall dimentsions 95 milimetre X 38 milimetre X 0.90 milimetre at weight 0.637 kilogram per running metre and window frame bottom track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 1.070 kilogram per running metre. Top and side track section 92 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jali with all required screws and nuts including all leads and lift etc.complete.
Providing and fixing 30 milimetre thick both side prelaminated solid panel polyvinyl chloride door shutter consisting of frame made out of mild steel tube of 19 gauge thickness and size 19 milimetre X 19 milimetre for styles and 15 milimetre X 15 milimetre for top and bottom rails, mild steel frame shall have a coat of metel primer of approved make and manufacture. Mild steel frame shall be covered with heat mouled polyvinyl chloride "C" channel made from 5 milimetre (+/0.25) thick prelaminated sheet of density 600 kilogram per cubic metre, of size 30 milimetre thickness 70 milimetre width out of which 50 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree angle on either side forming stiles; and 5 milimetre thick, 95 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 milimetre wide polyvinyl chloride sheet out of which 75 milimetre shall be flat and 20 milimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 milimetre (+/0.25) thick polyvinyl chloride strip of 20 milimetre width is to be stuck on the bottom side of the "C" channel prelaminated paneling of 5 milimetre (+/0.25) thick polyvinyl chloride sheet to be fitted inside the mild steel frame welded / sealed to the styles and rails with 5 milimetre (+/0.25) X 30 milimetre polyvinyl chloride sheet beading on either side and joined together with solvent cement adhesive, excetra 10 milimetre thickness (5 milimetre (+/0.25) X 2 numbers) 20 milimetre wide cross polyvinyl chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 numbers mild steel powder coated butt hinges of size 100 milimetre X 25 milimetre X 2 milimetre using 32 milimetre long steel screws drilled suitable to pass through both the walls of the mild steel tube. Other hardwares should be fixed with 19 milimetre X 6 milimetre size steel screws including fixture fasting. Complete as per direction of Engineer in-charge. (For Ground Floor)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 milimetre with lock plate of 3.15 milimetre thickness reinforced with 35 milimetre X 35 milimetre X 5 milimetre angle section fitted with sliding bolts and handles for both sides, deep mild steel channel section of depth and thickness not less than 65 milimetre and 3.15 milimetre respectively with hold fast arrangements, mild steel bracket plate 300 milimetre X 300 milimetre X 3.15 milimetre minimum size and shape with square bar, suspension shaft of minimum 32 milimetre diametre, hood cover of mild steel sheet not less than 0.9 milimetre thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer, including all leads and lift etc.complete.
Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, including all leads and lift etc.complete.
Providing and fixing self supporting steel roofing 3701.35 One 3338617.7 Square system (Proflex) for a Godown or alike made up of Square Metre structural grade steel sheet of 912 milimetre width Metre (tolerance +/- 2 milimetre), moulded at site using mechanical press dies to the desired curve and shape to form 605 milimetre wide interlocking panels. The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 32.50 metre having arch rise as 6.50 metre, arch length 37.70 metre. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 1.60 milimetre (tolerace + / - 0.02 milimetre) with alloy coating
Providing and applying two coats of exterior weather shield paint of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, including all leads and lift etc.complete.
Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete workfor chajja cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) including all leads and lift etc.complete.
Electrical Work Portion
Providing & erecting 4 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
Supplying and erecting terminal spreaders suitable for 4 pole, upto 100A MCCB (Set of 8)
Supplying and erecting SS enclosure of 1.6mm thick with detachable gland plate suitable for upto 100A MCCB.
Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire, D.P. Structure shall be erected in c.c. foundation complete
Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40 degree centigrate by thermometer in oil and 45 degree centigrate by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) , with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways/36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on provided iron/GI frame (vertical busbar type) as per specification no. SW-MCBDB
Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Supplying, erecting & marking TP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB Each
Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity (min. 125kg) complete, and recording the results specification no. EA-MF
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification no. WG-PW/CW
Point wiring for independent plug, concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wires, modular type switch and socket, earthing and required accessories as per specification No WG PW/SW
Point wiring for ceiling fan in minimum 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG- PW/SW
Wiring for plug on board with switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification no. WG PW/CW
Supplying and erecting LED square / circular Max. 18 W down lighter / Panel Light having pressure die- cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B0 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.
Supplying and erecting LED square / circular Max. 7W down lighter / Panel Light having pressure die- cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED.
Supplying and erecting integrated LED street light fitting 18 - 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG ODF/SL.
Supplying and erecting integrated LED Highbay Fitting 70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50, including driver complete with 2 Year warranty as per specification No FG-ODF/LED.
Supplying, installing, testing and commissioning of 25 kWp ON-GRID Solar pV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 75 Nos.) and Solar ON-GRID Inverter of similar capacity (THDwith interconnecting wires / cables up to solar ON GRID inverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liasoning charges, remote monitoring system with maintaining card / chip for 5 years including net charges for RMS System, complete upto net meter installation and export to the grid with 5 year ON-SITE warranty and 5 Years fully comprehensive maintenancecontract as per Specification no. ESD-RT-ONG.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 7.47 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 75 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG
Royalty charges for various building construction bonafied materials which are used for government bonafied works and for which Royalty charges are to be paid by the contractor. including all leads and lift etc.complete.
a)MURUM
b)Quarry Spaul
c)Soling Stone
LABOURATERY TESTING
For Metal
1) Crushing value /compressive strength,water absorption,Specific gravity
2)sieve analysis For metal
For Artificial Sand
3)Finess Modulus ,Silt and clay content
For RCC M-20 concrete
4)Concrete mix design
5)Compressive strength of cement concrete Cube
For Steel
6) Tensile Strength,Percentage Elongation, yield stress,Wt per metre Bend/Rebend Test Proof stress (upto 16 mm Dia of bar)
7) Tensile Strength,Percentage Elongation, yield stress,Wt per metre Bend/Rebend Test Proof stress (Above 16 mm Dia of bar)
For Brick
8) water absorption, compressive strength, Efflorescence Test
For Cement
9)Standard concistancy
10) Liquid limit , plastic limit
11)Compressive strength of cement morter Cube
For Tiles
12)water absorption
For alluminium
13)Thickness test
For Rubble
14)Crushing value
Management Strategies and Implementation Plan (MSIP) to manage the Environmental, Social, Health and Safety (ESHS) risks and ESHS Code of Conduct
Shri Sujay Mohan Patil
M/s Shiv Construction
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .