| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC C 736 GAUR GREEN AVENUE ABHHEYKHAND II INDIRAPURAM GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | UTTAR PRADESH | 201009 | L1 | Accepted-AOC AWARDED | |
| 2 | Rejected-Technical 305 306 SUNEJA TOWER II DISTRICT CENTRE JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | - | Rejected-Technical L5 | |
| 3 | Rejected-Technical 301 302 SUNEJA TOWER I DISTRICT CENTRE JANAK PURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | - | Rejected-Technical L4 | |
| 4 | Rejected-Technical NITI APARTMENTS NEW ERA TALKIES JUNCTION UNDERAI ROAD OFF SV ROAD MALAD W MUMBAI MAHARASHTRA 400064 | MUMBAI | MUMBAI | MAHARASHTRA | 400064 | - | Rejected-Technical L3 | |
| 5 | Rejected-Technical D 36 FIRST FLOOR RANJEET VIHAR NILTOHI EXTN WEST DELHI DELHI 110041 | WEST DELHI | DELHI | 110041 | - | Rejected-Technical L2 |
Tender Value
Refer Docs
Closing Date
25 Feb 2021, 3:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM/Electrical
C4 DISTRICT CENTRE SAKET NEWDELHI-17
E.S For Lot-1 and Lot 2.
2021_IRCON_70735_1
IRCON/ELECT 5037-5038 NCRTC ES1 LT/13
Limited
Electrical Works
Works
45 days
New Delhi And U.P
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
IRCON INTERNATIONAL LTD
Exempted
26 Mar 2021
19 Feb 2021
26 Feb 2021
19 Feb 2021
25 Feb 2021
20 Feb 2021
19 Feb 2021 - 20 Feb 2021
90 days
Amount
SUPPLY
Supply of Maintenance Free Earth Pits
Supply of Maintenance free earthing system having copper bonded steel rod of 25 MM diameter and 3/4 meter length shall be UL listed and certified. The rod shall be suitable to withstand short ckt currrent of 40 KA at 1 Seconds CPRI Tested. The copper bonded rod shall meet the requirements of IEC 62561-2 and UL 467.
Supply of earth enhancement material having resistivity <0.12 ohm-m shall be used in the surrounding of the earthing rods to have better resistance value. A 50 kg compound per Pit shall be installed in a bore dia. of 150 MM and 10 feet depth.
Supply of Earth Mats using copper bonded steel rod with exothermic welded joints
Supply of Maintenance free earthing system having copper bonded steel rod of 25 MM diameter and 3 /4 meter length. The rod shall be suitable to withstand short ckt currrent of 40 KA at 1 Seconds . The copper bonded rod shall meet the requirements of IEC 62561-2 and UL 467.
Supply of Earthing riser 50x6 MM made up of copper coated steel material. The riser shall be exothermically welded.
Supply of Exothermic Joints:
Straight Joints : 2 way between 50x6 mm Copper bonded steel strip to 50x6 mm Copper bonded steel strip
Straight Joints : 2 way between 25 mm dia. rod to 25 mm dia rod.
L Joint : 2 way between 25 mm dia. rod to 25 mm dia rod
TEE Joint : 2 way between 25 mm dia. rod to 25 mm dia rod
Cross Joint: 2 way between 25 mm dia. rod to 25 mm dia rod
Tee Joint : Earthing risers joints with 25 mm dia. earth rod with 50x6 MM copper bonded steel rod.
Main Earth Terminal 750mm Long 75X6 mm Copper Bonded Steel
ERECTION
Maintenance Free Earth Pits
SITC of Maintenance free earthing system having copper bonded steel rod of 25 MM diameter and 3/4 meter length shall be UL listed and certified. The rod shall be suitable to withstand short ckt currrent of 40 KA at 1 Seconds CPRI Tested. The copper bonded rod shall meet the requirements of IEC 62561-2 and UL 467.
ITC of earth enhancement material having resistivity <0.12 ohm-m shall be used in the surrounding of the earthing rods to have better resistance value. A 50 kg compound per Pit shall be installed in a bore dia. of 150 MM and 10 feet depth.
Earth Mats using copper bonded steel rod with exothermic welded joints
ITC of Maintenance free earthing system having copper bonded steel rod of 25 MM diameter and 3 /4 meter length. The rod shall be suitable to withstand short ckt currrent of 40 KA at 1 Seconds . The copper bonded rod shall meet the requirements of IEC 62561-2 and UL 467.
ITC of Earthing riser 50x6 MM made up of copper coated steel material. The riser shall be exothermically welded.
ITC of Exothermic Joints:
Straight Joints : 2 way between 50x6 mm Copper bonded steel strip to 50x6 mm Copper bonded steel strip
Straight Joints : 2 way between 25 mm dia. rod to 25 mm dia rod.
L Joint : 2 way between 25 mm dia. rod to 25 mm dia rod
TEE Joint : 2 way between 25 mm dia. rod to 25 mm dia rod
Cross Joint: 2 way between 25 mm dia. rod to 25 mm dia rod
Tee Joint : Earthing risers joints with 25 mm dia. earth rod with 50x6 MM copper bonded steel rod.
ITC of Main Earth Terminal 750mm Long 75X6 mm Copper Bonded Steel
Mettanox Infrateck Private Limited
Manav Energy Pvt Ltd
K. V. Prateek Enterprises
Jebla Construction
stage.html
html • 0.04 MB
techsummary_76022.pdf
PDF • 0.07 MB
finsummary_76022.pdf
PDF • 0.07 MB
JMV_EARTHING_LOA.pdf
PDF • 1.56 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .