Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC | L1 | Accepted-AOC BeingLQ | |
| 2 | L2₹11.7 L+₹59,225 (5.32%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹12.7 L
EMD Value
₹25,340
Closing Date
20 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
PROVISION OF THREE PHASE SUPPLY TO STANDBY TWCC AND ADDITION/ALTERATION OF SQUASH COURT AT 8FBSU
2023_MES_580539_1
GE (AF) AWA-40/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) AWANTIPUR
₹25,340
Yes
29 Apr 2023
13 Feb 2023
23 Mar 2023
13 Feb 2023
20 Mar 2023
28 Feb 2023
Amount
S&F in repair Maple wooden Flooring Surface Board:- Made of Kiln Seasoned (moisture containt of approximately 14% at the time tiome of dispatch), Treated Maple Wood finished with 24mm thick, 57 to 83 mm wide and in random length in tongue and groove shape. The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti termite and water resistant lacquer.Maple wood is the hardest of hard woods and is the recommended wood for squash court. All major tournaments are played on Maple Wood Floor only the Under Frame:- Made of commercial quality pine wood runners of 70 mm x 45 mm, treated with anti-termite solution and fixed on the bottom side with 10 mm thick air cushioned pads, stappled through the two wings at 300 mm x 300 mm. Installation:- IPS subfloor treated with a vapour barier to be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cushion pads to be placed on the vapour barier in perfect level at 350 mm in 1 direction. The surface board to be screwed to the runner through the tongue only and will lock the screwed tongue by the groove of adjoining board. Ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area / walls. Finishing:- After laying the flooring, the floor boards will be levelled to a uniform surface and applied a thin coat of water based police on the the facecomplete in all respect to the entire satisfaction of Engineer-in-Charge. Note:- Demolition of old wooden flooring is including in the item.
Taking down Cement Plaster, any description on Brick Walls or on Concrete Surfaces including raking out Joints, hacking for Key, scrubbing down with Water, etc, and removing same from the Site(s), complete all as specified and as directed.
Supply and Application of Hard Plaster System meeting specifications for Squash Court laid down by "World Squash Federation" (WSF). The system consists of a 10 mm base coat with silica sand and top coat (WSF approved hard plaster) of 2-3 mm, which makes it a total thickness of 12 - 13 mm. Due to extremely hard nature of plaster a slight uneven color distribution may be seen once the plaster has dried, this doesn't affect the trength or integrity of the plaster and must not be considered as a defect.
M&L for rendering 15 mm thick on fair faces of concrete/brick interior surfaces in cement mortar 1:6 as per manufacturer's instruction, finished fair and even without using extra cement complete all as specified and directed.
S&F interior emulson paint on plastered surface of wall complete all as specified and directed by Engr-in-Charge. MAKE : BERGER/ASIAN/NEROLAC/JEHNSON AND NICOLSON.
M&L for WSF approved standard game line marking complete all as specified and directed by Engr-IN-Charge.
M&L preparation of newly plastered wall surface and applying white wall putty approx 3 mm thick in two layer as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed. MAKE: BIRLA/ASIAN/JK CEMENT.
Dismantling wall and ceiling boards (fibre pulp, insulation, etc) or insulation board/slabs/blankets/wooden flooring any thickness including grid work/aluminium frame work, cover fillets complete all as specified.
S&F 12 mm thick Veneered decorative plywood, grade 1(with BWR resin) with decorative face veneers on both faces for ceiling ; fixed with screws to timber or metal frame work complete all as specified and directed. MAKE: GREENPLY/NATIONAL/KITPLY/CENTURY/MYSORE CHIP BOARD.
M&L for preparing of old painted steel surfaces over 10cm width or girth and making good surface and smooth by rubbing with sand papers etc and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L for complete removal of existing treatement by scraping, washing, rubbing down or stopping distempered or painted surfaces etc of walls plastered or un-plastered & removing all vegetation growth, cleaning to the entire satifactory of Engr-in-Charge & applying of Birla/JK white wall putty approx 3 mm thick in two layer as per manufacturer's instruction on existing prepared surface and make the surface smooth by rubbing with sand papers and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
Taking down copper/aluminium point wiring(light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.
Taking down DB 12 Way 415 Volt/240 Volt including MCB/MCCBs.
Taking down light fittings of any type complete all as directed .
Taking down old aluminium sub main wiring of any size.
M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cable as earth continuity cable including plastic gang box pressed steel terminal boxes made out of MS sheet duly painted with one coat of red oxide primer with 3 mm thick laminated sheed cover for mounting of switches, socket, fan regulators complete all as specified for the following:- (a) One light/fan point controlled by one switch 6 Amps one way.
(b) One 3/5 pin socket outlet, 5/6 Amp on the same board controlled by one nos, one way switch.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent controlled by one nos, one way switch.
S&F in replacement of piano type socket outlet flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified. MAKE: HAVELLS/PLAZA/POLYCAB/INDOASIAN.
S&F in replacement of piano type switch socket combination flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.MAKE: HAVELLS/PLAZA/POLYCAB/INDOASIAN.
S&F Piano type switch , Flush type single pole, one way 6 amps. MAKE: HAVELLS/PLAZA/POLYCAB/INDOASIAN.
S/F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete. MAKE: HAVELLS/PLAZA/POLYCAB/INDOASIAN.
Supply and fix exhaust fan made of sturdy, engineering plastic complete with louvers shutter, voltage 230V, 50 hz, RPM 1200, copper winding of sweep 300mm. MAKE: BAJAJ/USHA/HAVELLS/CG.
Supply and fixing Highbay luminaire with pressure die-cast housing, toughened glass of capacity 100 Watts and 130 lm/W efficacy. 4 kV in-built and 10 kV external surge protection. IP66 ingrass protection with additional safety chain complete as directed. Make- Bajaj (cat part no - BIHNK 100W WH NB TG SD)/ Philips/Crompton/Havells
Supply and fixing round shape 12 watt 220 volt AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete as directed. MAKE : Havells/Bajaj/Phillips/Crompton
S & F surface mounted 1x20watts LED tube light fitting 220volts AC decorative box type with driver holder incliuding LED tube light connecting up with 3core flexible copper conductor cable of suitable size from ceiling rose complete. Make: Havells/Bajaj/Phillips/Crompton
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 watts 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete as directed. Make: Havells/Bajaj/Phillips/Crompton
S & F in replacement Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor in and incl rigid PVC conduit comcealed in wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuity all as directed. Make: Plaza/Havells/Polycab/KEI
S & F Single pole and neutral sheet steel powder coated vertical type Double door Distribution board for MCCB/MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply SP&N DB system 12 ways. Make: Legrand/L&T/Havells/ABB
S & F MCB , 240 V, SPN 40 Amps With rupturing capacity 10 KA Make: Legrand/L&T/Havells/ABB
S& F MCB SP , 6-32 amps, Rupturing Capacity 10 KA , 240 volts , Make: Legrand /L&T/Havells/ABB
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.0 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia through GI pipe "light Grade" as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
Supply, laying and testing of LT cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core. Make: Polycab/Havells/Gloster/Universal
S&F wiring for submain with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FR type, 1100 volts grade 2 x 4 sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 4 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. Make: Plaza/Havells/Polycab/KEI
Supply and install Hi wall split type Air Conditioner inverter type units indoor/outdoor unit complete with heating and cooling function with cordless remote control unit and with in built air ioniser and Plasma filter for better air quality with 4 star rating of capacity 2.0TR split unit air conditioner electric driven single phase copper condensor complete all as specified and directed. Make-Hitachi/Carrier/Bluestar/Voltas.
Supply and fix only 5.0 KVA Voltage stabilizer for automatic operation, single phase for Air conditioner nqaturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy +/- 5 % tolerance and speed of correction 8 volts per second complete all as specified. Make: V-Guard/Premium/Volina/Sinetrac/powerware.
Supply and fixing only 40 KVA Voltage stabilizer for automatic operation, three phase supply naturally air cooled indoor type & designed for input variation between 300V to 480 V with output voltage stabilized at 415 V with accuracy +/- 5 % tolerance and speed of correction 8 volts per second complete all as specified. Make: Powerware/Sinetrac/volina/voltamp.
S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20Amps, 240 V complete all as specified. Make: Havells/Legrand/L&T/Schneider
S&F of factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 Volts with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete with & including one No. MCCB 100 Amps 3 pole 25 kA fixed type for incoming and 3 no 20 Amp SPN as outgoing complete all as specified. Make of DB: Legrand cat pt No. 607913 or equivalent in Schneider/Havells and Make of MCCB: Legrand cat pt No. 420045 or equivalent in Schneider/Havells/L&T.
M&L earthing complete with galvanised steel earth plate electrode 60cmx 60cm x6mm thick burried directly in ground ( earth pit not less than 2.25 mtr below normal ground level ) connected to and including galvanised iron strip 25x4mm by means of bolts nuts check nuts and washers of galvanised iron or steel including PCC pit in PCC 1:2:4 type B-1 RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm grade crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron 40x40x5mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh light grade protection pipe 40mm bore upto main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion all as directed. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.
M&L for Test point terminal block for earthing made of gun metal or phosphorus bronze size 75x75x25mm driled and srewed including 3 nos 8mm dia 25mm long hex head srew.
M & L for earth continuty conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm Galvinised strip complete all as specified and directed by.
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n exc 1.5 mtr in depth and getting out all as required for laying of cable , foundation of poles or stays etc.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
Removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Dry sand cushioning to underground cables provided with a layer of sand 8cm deep before laying th cable and 15cm deep after laying and stretching the cable.
Supply and fixing brick covering with width equal to length of brick as mechanical protection to cable using sub class 'B' bricks laid flat size 230x115x75mm complete all as specified and directed.
Note :- An amount of Rs. 1,283.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/s Gh Qadir and Sons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .