Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.5 LAccepted-AOC | 1 | Accepted-AOC first lowest | |
| 2 | 2₹12.6 L+₹11,020.48 (0.88%)Rejected-Finance A 04 ADGNJ CHANDAN NAGAR OPP IOCL PETROL PUMP RAMPUR ROAD BAREILLY U P 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | 2 | Rejected-Finance 2 lowest | |
| 3 | 3₹12.9 L+₹42,074.49 (3.38%)Rejected-Finance 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | 3 | Rejected-Finance 3 lowest | |
| 4 | 4₹15.0 L+₹2.5 L (20.1%)Rejected-Finance 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | 4 | Rejected-Finance 4 lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not qualified |
Tender Value
₹21.9 L
EMD Value
₹33,000
Closing Date
29 Sept 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer, Electy. Works Circle
3-Civil Lines, Bareilly
INCREASING CAPACITY OF 33/11KV S/S CHAUHANAPUR (SHAHJAHANPUR) FROM 1X5 MVA TO 2x5 MVA AND ITS ASSOCIATED 11 KV LINK LINE.
2020_MVVNL_511586_1
03/EWC(B)/2020-21
Open Tender
Electrical Works
Fixed-rate
90 days
Shahjahanpur
As per tender document
3 documents required · 3 mandatory
₹3,540
A/c No. 019205006347, IFSC Code ICIC0000192
₹33,000
13 Jul 2021
15 Sept 2020
30 Sept 2020
15 Sept 2020
29 Sept 2020
15 Sept 2020
180 days
Amount
(A) INCREASING CAPACITY
Loading, unloading and safe carriage of the following materials from any Electy. Store Center of Electricity store division of Bareilly zone.
M.S. Channel 125x65mm @ 13.1 kg./mtr.
MS Channel 100x50mm @ 9.5 kg./mtr.
M.S.Angle 75x75x8mm @ 8.9 kg./mtr.
MS Angles 50x50x6mm @ 4.5 Kg/Mtr.
33 KV Post insulator
33 KV Lightening Arrestor
33 KV 400 A Bus Isolator
33 KV VCB 800A 750 MVA
33 KV I/C control pannel for single T/F
5 MVA 33/11KV Transformer
33 KV O/D CT CTR 200/100/1
11 KV VCB I/C CTR 600/300/5A 250 MVA 630 A
11 KV VCB O/G CTR 200/100/5A 350 MVA
11 KV Cable 3x300 Sq. mm XLPE for Transformer
11 KV Cables 3x185 Sq. mm XLPE for feeder
11 KV Cable jointing Kit heat shrinkable type for 185 Sq. mm indoor type.
11 KV Cable jointing Kit heat shrinkable type for 185 Sq. mm outdoor type.
11 KV Cable jointing Kit heat shrinkable type for 300 Sq. mm indoor type.
11 KV Cable jointing Kit heat shrinkable type for 300 Sq. mm outdoor type.
ACSR Dog conductor
Earthing of Indoor & Outdoor equipments of the Sub-Station after proper clamping and welding of joints including painting inside soil as per RESSPO Approved drawings as per details given below.
Providing of well type pipe earthing upto 40 Mtr. Depth below G/L or upto water level including welding etc. By Boring process at T/F Neutral, L.A and structures including cost of Gl Pipe of size 40mm dia 10 Mtr Long of lSI mark Required for proper completion of works.
Welding & laying of GS strip 50x6mm size with all newly erected structures and all equipments in switchyard and control room with M.S. Bar including cutting binding and proper fixing etc complete. The welding and laying of GS Strip to LA. with full length of structures and also the M.S. bridge near L.A. structures.
Preparation of Power T/F plinth in size 4.5x3.5Mtr. 36 inches above ground level and fixing of rail pieces 2 Nos. as per RESSPO/ Approved Drawing suitable upto 10 MVA load with complete material (all material will be provided by firm).
Fabracation, erection and grouting of the following structures as per RESSPO/ Approved Drawing and its, plinth 30cm above ground leval as directed by the Engineer Incharge (All steel sections will be provided by Deptt).
Bus Isolator Structure
Lightening Arrestor Structure
33 KV VCB Structure
33 KV CT Structure
Fuse Set Structure
Post insulator Structure
Installation of followig equipments on their respective structures including mechanical & electrical fixing after proper adjustment on their structure.
33 KV Bus side isolator (will be provided by Deptt.)
Lightening Arrestor (will be provided by Department).
33 KV VCB complete (will be provided by Deptt.)
33 KV CT (will be provided by Deptt.) (03 Nos)
33 KV Fuse Set (will be provided by firm)
33 KV Post insulator (will be provided by Deptt.)
24 V DC battery set with charger (capable to charge battery on boost & float mode of capacity 200 A.H. with cabinet, ISI mark) will be provided by firm.
Complete laying and termination of copper control cables from 5 MVA power T/F, 33 KV VCB, 33 KV CT in the out door switch yard to the Transformer relay control panel inside the control room including cost of all materials and labour required for proper completion of works as per RESSPO drawings, including cost of testing of transformer, VCB, CT, relay pannel & proper replay settings as per requirement etc.
Laying of dog conductor alongwith cost of all required calmps and connectors etc. as per RESSPO Approved drawing of L.A., C.T., V.C.B., Bus Isolator etc.
Making of M.S. Angle Ladder type frame of Angle (65x65x6mm) & M.S. Strip (50x6mm) near power transformer for power cable with concreting of the same in the ground and proper clamping (50x6mm) of the same with transformer cable.
Making of M.S. Angle frame of (65x65x6mm) in the shape of "L" to connect T/F Neutral by copper flexible strip with proper clamping including cost of copper strip. Earthing of Power T/F Neutral shall be done separately including welding with M.S. bar Electrode bridge 1 No. after making in triangular shape and proper connection with well type earthing etc.
Laying of 11KV cable of different size from power T/F to control room I/C and control room to D/P outside Sub-Station over a pad of river sand. Cable shall be laid 500mm below the ground in the yard by covering three sides with Ist Class brick and Ganga sand.
Erection of incoming and outgoing panels (with testing & setting of relays) in substation control room including grouting of Anchor bolts of panel and making of pocket for power cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Erection & testing of 1 No. T/F Control penel in substation control room including grouting of anchor bolts of panel and making of pocket for control cable to insert in panel from trench and complete filling of control room's tranches by river sand.
Termination of 11 KV Different size XLPE cable by filling 11 KV heat shrinkable type cable boxes including proper connection with LV side of transformer, switch gear panels and double poles by providing suitable connectors.All the 11 Kv cable boxes of different sizes shall be provided the Department.
Shifting and dragging of 33/11 KV 5 MVA transformer from road side to its plinth alongwith its erection including fixing of all assessories and top-up of transformer oil.
Painting of the fabicated structures with one coat of red oxide primer and two coats of synthetic enamel alumm. Paint/green paint of ISI Mark alongwith earthing strip above ground level.
Providing of Rubber matting sheet 8/10mm of good quality as per standard specification.
(B) 11 KV LINK LINE
Carriage of following line material for 11KV line from Store Centre to the site of work including measuring, weighing, loading, unloading at both ends and proper stacking at safe site
STP 11Mtr. long
PCC Pole 8.5 Mtr. long
11 KV Cross Arm Channel V type
11 KV Pin insulator with pin
11 KV Disc insulator T&C type 45 KN. with its fitting
ACSR Raccon conductor
G.I. wire 6SWG/10 SWG
Stay set complete
Earthing complete
Gaurding Angle 1.6mtr. Long
M.S angle lron 65x65x6mm
MS Channel 125x65x1300mm Tee off
M.S.Channel 100X50X22400mm @ 10Kg/Mt. for Top channel
Erection of the following supports after making of pits & filling of pits by concrete of ratio 1:4:8 (cement brick balast & sand). Fitting of all accessories as cross arm, top channel, bracing angle, pin insulator, disc insulator & clamps etc. Plinthing of support above 300mm ground level by concrete of ratio 1:4:8 (cement brick balast & sand) will be done at the time of erection of pole. Painting of ST Pole structure as per RESSPO norms (all type of paints, red oxide primer, nut, bolts & grouting material etc. will be provided by contractor).
Single support of S.T pole 11 mtr long.
Single support of PCC pole 8.5 mtr long.
Double pole structure on PCC Pole 8.5mtr long complete with bracing.
Double pole structure on S.T. Pole 11mtr long complete with bracing.
Erection of stay set including its grouting by concrete of ratio 1:4:8 before back fitting of the pits including binding, climbing, clamping, tightening and nozzeling of stay wire in all respect as per RESSPO norms. All clamps, nuts, bolts, cement. brick, ballast, sand etc would be provided by the contractor.
Laying and sagging of 3 phase ACSR Raccon conductor from double pole at 33KV substation for 11 KV feeder line including jumpering, hoisting, fixing of all type of insulators, binding, jointing and its clamping etc. in all respect.
Earthing of each S.T Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Earthing of each PCC Poles of the line is to be done by inserting the MS earth rod (1800x20mm) into soil by hammering and properly fastning with GI wire to each support & its accessories by nut & bolt. Earthing rod must be 0.15Mtr.above from the plinth of the support. All type nut & bolt would be given by the contractor.
Guarding of HT/LT/Telephone Line/ Road/River Crossing etc. by providing G.S Earth wire 7/16 SWG/GI wire No. 8/10 and making net with difference of 1.00 Mtr. Completely including fixing of channel/angle etc. with proper locking at each support. All type nut &bolts, would be given by the contractor.
Supply & fixing of danger board, number plate & GI barbed wire as anti climbing device on each support of 11 KV line (all material will be provided by the contractor).
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of site incharge.
BHARAT ELECTRICAL TRADERS
M/s Shubham Traders
Bharat Trading Corporation
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .