| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC | ₹48.0 L Quoted ₹48.6 L | L1 | Accepted-AOC LOWEST |
| 2 | L2₹55.1 L+₹6.5 L (13.4%)Rejected-Finance | ₹55.1 L+₹6.5 L (13.4%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹56.0 L+₹7.3 L (15.1%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹56.0 L+₹7.3 L (15.1%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | Rejected-Technical | - | - | Rejected-Technical NOT QUALIFIED |
| 5 | Rejected-Technical 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | - | - | Rejected-Technical NOT QUALIFIED |
Tender Value
₹57.5 L
EMD Value
₹1.1 L
Closing Date
26 Jun 2020, 6:00 pmClosed
CWE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
Special Repair to Roof False Ceiling Partition Wall Joinery Tiling and Electrical Work In Building No. T-12 Under GE (South) Bangalore
2020_MES_346244_1
85979 / E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE South Bangalore
₹1.1 L
Yes
CWE Army BANGALORE
27 Jul 2020
22 May 2020
29 Jun 2020
22 May 2020
26 Jun 2020
12 Jun 2020
22 May 2020 - 29 May 2020
29 May 2020
Amount
Dismantling wall and ceilling boarding, (fiber, pulp, insulation, etc.) or insulation board / slab / blankets, any thickness, in snap grid complete all as directed.
False ceiling with GI snap frame work of size 600 x 600 mm in true horizontal level suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanized @ 170 gsm / Sqm and bottom exposed width prefinished with baked polyester paint) consisting of main `T’ runners of size 38 x 24 x 0.3 mm with suitably spaced joints to get required length spaced at 1200 mm C/C and cross T of size 24 x 25 x 0.3 mm, 1200 mm long spaced between main T at 600 mm C/C to form a grid of 1200 x 600 mm and secondary cross `T’ of length 600 mm and size 24 x 25 x 0.3 mm to be interlocked at middle of the 1200 x 600 mm panel to form grids of 600 x 600 mm and wall angle of size 21 x 21 x 0.3 mm
and laying flase ceiling tiles of 4 mm thick fibre, cement building board, non asbestos (minimum weight 4.8 kg / m2) fixed or laid / inserted to GI frame work with screws / clips for false ceiling work including, wherever required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main T runners shall be suspended from ceiling using GI slotted cleats of size 25 x 35 x 1.6 mm fixed to ceiling with 6 mm dia and 50 mm long metal dash fastener, 4 mm GI rods with galvanized steel leveling clips spaced at 1200 mm C/C along main `T’ section (False ceiling system shall be capable to bear distributed load of minimum 15 Kg / Sqm) complete all as directed
Dismanteling of Asbestos cement (corrugated semicorrugated etc) sheets in roof covering complete all as directed
Prepainted galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self taping screws or 'L' type or 'J' type or cranked hook bolt, complete all as directed.
Prepainted galvalume Aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall fixed with self taping screws or 'L' type or 'J' type or cranked hook bolt, complete all as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises, complete all as directed.
Non Skid coloured ceramic tiles 7 to 8 mm thick (Joint free) (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including 15 mm thick screed bed in cement mortar (1:6) complete all as directed.
Glazed coloured cermaic tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick as in vertical surfaces of walls, set and jointed in neat cement slurry and pointed in coloured cement to match, over and including 10 mm thick rendering in cement mortar 1:4 complete all as directed.
Grinding and polishing for existing kota stone floor complete all as directed.
Demolition of brick / block work built in cement mortar complete all as directed.
Demolition of cement concrete (unreinforced ) in floors and pavings n. exc. 150 mm thickness below or above ground level complete all as directed.
Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only) complete all as directed.
Precast cement block masonry with solid blocks grade C-5, 10 Cm in width and setting in cement mortar 1:4 complete all as directed.
Screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 for laying floor finishing complete all as directed.
Machine cut cudappah stone slab 20 - 25 mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) n. exc 1.5 sqm each complete all as directed.
Forming Jambs, etc. to openings (to foregoing items), including cutting, toothing and properly bonding in old work also facing jointing and pointing to match existing work in cement mortar 1:4 complete all as directed.
Aluminium frame, powder coated for windows, ventilators, sliding windows etc, with one or more rebates including joinning cleat for fixing etc powder coating of any colour (powder coating not less than 50 micron), and thickness of section not less than 1.5 mm thick confirming to IS 737-1986 complete all as directed.
Aluminium window and ventilator shutters powder coated, any colour (powder coating not less than 50 micron), fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, aluminium snap beading, screws, roller, locking arrangements etc confirming to IS 737-1986 complete all as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with tinned tacks or galvanized wire staples fixing ‘in repair’ complete all as directed.
5 mm thick tinted sheet glass and glazing with aluminium beading & rubber gasket in square in each panes complete all as directed.
Aluminium grill, powder coated (of powder coating not less than 50 micron), of 50 mm aperture and 7 mm thick complete fixing to anodised aluminium frame work with packing materials etc. complete all as directed.
Second class hard wood in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints scantlings complete all as directed.
Plain Scantling, fillets exc. 13 Sqcm and n.exc 25 sqcm. square, rectangular in section, clean sawn, secured with nails or brads complete all as directed.
Prelaminated particle board, 19 / 20 mm thick, interior grade (Grade-II, type-III, PLB-23) having ISI Marked (IS: 12823 : 2015) prelaminated both sides with decorative type fixed with screws complete all as directed.
Taking down Chowkhats or frames exc. 1.5 but n. exc 4 Sq. m each with shutters (without taking off shutters from the frames) complete all as directed.
Cutting holes in brick walls built in cement mortar exc half brick wall but n exc one brick wall for incerting hold fast and securing bolts etc and making good dismenteled portion in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required complete all as directed.
Pressed steel frames for door of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate with filling of hollow of frame with PCC 1:2:4 tybe B-1 (20 mm stone agg) confirming to IS 4351-1976 complete all as directed.
Plain framed panelled shutter 30 mm thick of 2 nd class hardwood (any number of panels), with panel of timber flat on both sides (feathered edge) or of veneered particle board medium density, commercial face veneers include for one shop coat of priming confirming to IS 1003 (part-1) 2003 complete all as directed.
35 mm thick of 2 nd class hardwood glazed and skeleton shutterts open rebated and prepared to receive glass, gauge etc divided into sqaure with plain chamfered or rounded mitred and retreated sash bars any numbers edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members as specified in SSR Part - I. confirming to IS 1003 (part-1) 2003 complete all as directed.
Second class hardwood plain fillets, square rectangular or triangular in section clean sawn, screwed with nails or beads and bullnosed, splayed chamfered or rounded on one edges or face n exc 25 Sqcm complete all as directed.
Bands, straps, hold fast or similar small articles confirming to Fe 290 Gde -E-165 complete all as directed.
Stainless steel barrel tower bolt, 200 mm long complete all as directed.
150 mm size stainless steel pressed handles, oval type, complete all directed.
250 mm long Stainless steel, sliding door bolts, plate type with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as directed.
Butt hinges medium weight rolled stainless steel and fixed of size 100 mm complete all as directed.
Solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet, reinforced with MS square tube and fixing in position with hold fast, complete all as directed.
Factory Made Solid PVC Moulded Door Shutter With Particle Board Core, 28 to 30 mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick Moulded PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, fixing in frame at site complete all as directed.
Aluminium anodised alloy barrel tower bolt 200 mm size complete all as directed.
Extruded aluminium alloy handles, fabricated type anodised 150 mm size complete all as directed.
Butt hinges medium weight cold rolled mild steel and fixed of size 100 mm complete all as directed.
Drapery rod of high stregth aluminium, powder coated (minimum 40 micron) of outer dia 28 mm and ineer dia 24.5 mm with 2 Nos of brackets (projected type / wall to wall) finials complete all as directed. Make:- Sleek line type -II of MAC or Soffio-II of vista levolar or equivalent
Demolition of cement concrete (unreinforced) in floors and pavings n. exc. 150 mm thick below or above ground level complete all as directed.
PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in 75 mm thick plinth protection / path / paving finished even and smooth without using extra cement including forming groove 10 mm wide, 30 mm deep, filled with mastic filler complete all as directed.
Taking down cement plaster of any description on brick or stone walls, etc. including racking out joints, hacking for key, scrubbing down with water as in kitchen plateform etc, complete all as directed.
Rendering 15 mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as directed.
Preparing new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over 1 mm (minimum) thick wall putty on plastered surfaces preparatory to distmpering, complete all as directed.
Rendering 15 mm thick on brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as directed.
Preparing new plastered surfaces of any description and applying two coats of cement base paint over a coat of alkali resistant priming paint etc complete all as directed.
Complete removal of existing treatment over the plastered wall surface and preparation of old plastered surfaces of wall over 1 mm thick wall care putty and applying two coats of distemper oil emulsion white or tinted complete all as directed.
Complete removal of existing treatment on walls and applying two coats of cement base paint over priming plastered and other surfaces with alkali resistant priming paint complete all as directed.
Preparation of old painted steel or iron surfaces of any description over 100 mm width or girth and applying one coat of synthetic enemal paint of approved tint complete all as directed.
Preparation of old wooden surfaces of any description not otherwise described over 100 mm width or girth and applying one coats of synthetic enamel paint complete all as directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring,etc., and making good, cutting exc. 100 mm but not exc. 200 mm girth complete all as directed.
Granite (any type) 20 mm thick work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite but except stone complete all as directed.
Taking up or down steel tubing and connections, 15 mm bore including cleaning for refixing or removal to store complete all as directed.
Taking up or down steel tubing and connections, 20 mm bore including cleaning for refixing or removal to store complete all as directed.
Taking up or down steel tubing and connections, 25 mm bore including cleaning for refixing or removal to store complete all as directed.
15 mm bore, steel water tubing, medium grade, galvanised with all fittings fixed to wall or laid in trenches, complete all as directed.
20 mm bore, steel water tubing, medium grade, galvanised with all fittings fixed to wall or laid in trenches, complete all as directed.
25 mm bore, steel water tubing, medium grade, galvanised with all fittings fixed to wall or laid in trenches, complete all as directed.
Gun matel gate valve 20mm bore, with iron wheel head for iron pipe, fixed in repair complete all as directed.
Dismantling water tanks of capacity 1000 to 2000 liter and removing to store complete all as directed.
Rotational moulded HDPE water storge tank of capacityy 5000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position including connection nipple confirming to IS 12701-1996 complete all as directed.
Ball valve, 20 mm bore, brass body, high pressure, with polythene float and fly nut, screwed for iron pipe or brass ferrule, fixed in repair complete all as directed.
Bib taps, 15 mm bore, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, fixed in repair complete all as directed. Make:- Ruby series of cera or equivalent of Kohlar / Jaguar
Wall Mixer chromium plated fancy type including three joints to steel pipe or union for 15 mm bore pipe, fixed in repair, complete all as directed. Make:- Ruby series of cera or equivalent of Kohlar / Jaguar
Pillar taps, 15 mm bore, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and flynuts, screwed for iron pipes, fixed in repair complete all as directed. Make:- Ruby series of cera or equivalent of Kohlar / Jaguar
Angle valve, 15 mm bore, fancy type, chromium plated, screwed at both end for iron pipe or for unions, high pressure having crutch handle, fixed in repair complete all as directed. Make:- Ruby series of cera or equivalent of Kohlar / Jaguar
Towel rail chromium plated, fixed in repair with chromium plated brass screws and plastic cleats (included) complete all as directed. Make:- Cat part No. BA-20 of Prayag or equivalent of Hindware / Jaguar
Shower rose 100 mm dia, brass chromium plated, with swivel type joint including fixing in repair to steel pipes or union complete all as directed.
Polythene pipe connection pieces 450 mm long 6 Kg/Sqcm pressure rating with two sets of mild steel chromium plated adopted at each end, suitable for fixing to 15 mm bore GI tube, fixed in repair complete all as directed.
Viterous china squating pan Orissa pattern WC of size 580 x 440 mm white with integral foot rest with 'P' or 'S' trap fixed in repair with cast iron and stoneware fitting including provn of lime concrete / cement concrete bedding complete all as directed.
Vitreous China wash down, water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as directed.
Plastic cover for the EWC seat, white or black, closet pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as directed.
PVC Flushing cistern, dual type, low level of 10 liter capacity white with inlet ball valve float and handle including bracket. PVC connections 15 mm size with PTMT nut of length 450 mm etc. complete all as directed. Make:- Cat part No. 502 of Prayag or equivalent of cera / Parryware / Hindware
Flush pipe, 32 mm dia, polyethylene for low level flushing cistern, complete all as directed.
Health faucet with 1.5 M flexible Chromium plated tube and hook fixed to angle valve fixed in repair etc. complete all as directed. Make:- Cera / Pryag / Jaguar / Hindware / Kohlar
Angle Cock 2 way, double handle with flange, fancy type, cast copper alloy chromium plated, 15 mm bore screwed down, screwed for iron pipe or for brass ferrule fixed in repair complete all as directed.
Viterious china wash basin white oval shape (under counter basin) of size 560 x 410 x 180 mm, fixed in repair, exclusive of waste pipe complete all as directed.
Toilet paper holder box type brass CP anodised fixed in repair to wall, with chromium plated brass screws, complete all as directed.
Soap dish fancy type cast copper alloy type chromium plated, fixed ‘in repair’ complete all as directed.
PVC waste pipe with coupling, heavy duty, 32 mm dia for wash hand basin etc. fixed in repair complete all as directed.
110 mm bore PVC (SWR) waste and vent pipes in any length with rubber ring joints fixed in repair to wall etc. complete all as directed.
PVC (SWR) waste pipe and vent, 75 mm dia in any length with rubber ring joints with laid in floor etc. complete all as directed.
PVC (SWR) bend, 110 mm dia, complete all as directed.
PVC (SWR) Tee junction single (single Tee) equal or unequal 110 mm dia with acces door complete all as directed.
PVC (SWR) reducer 110 mm dia, complete all as directed.
PVC (SWR) vent cowl 110 mm dia complete all as directed.
75 mm bore PVC Floor trap with grating including jointing to waster pipe and embedded in concrete complete all as directed.
Demolition of cement concrete (unreinforced) in floors and pavings n. exc. 150 mm thickness below or above ground level complete all as directed.
75 mm thick, plain cement concrete 1:4:8, type D-2, by using 40 mm stone aggregate as in sub base etc. complete all as directed.
20 mm thick, screed bed or bedding, layer in cement mortar 1:4 for laying floor finishing etc. complete all as directed.
20 to 25 mm thick coloured glossy finished factory made PCC designer tiles / pavers, set, jointed and pointed in neat cement slurry as in path / floor etc. complete all as directed. Note : The size , colour & combination of tiles as approved by GE).
Demolition of RCC roof, floor (other than ground foor), beams, staircase, landing, chjjas, coer slabs and similar suspended work
Formwork to sides and soffits of beams or lintel beams etc. rough finished complete all as directed.
RCC (1:1.5:3) by using 20 mm graded stone aggregate as in beam, lintle band and lintles over 1.5M complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed.
Excavation in trenches N exc 1.5 M wide and N exc 1.5 M depth for foundation or cable trench etc. and getting out in hard / dense soil complete all as directed.
PCC 1:5:10 type E2 (using 40 mm stone aggregates) as in foundation, filing and mass concrete complete all as directed.
Precast cement concrete block masonry with solid blocks grade C-5, exc 10 Cm in width and setting in cement mortar 1:6 complete all as directed.
RCC (1:1.5:3) using 20 mm graded stone aggregate as in roof beam etc. complete all as directed.
Formwork to edges of concrete flat, treads RCC / PCC band etc. exceeding 100 mm but not exc. 200 mm wide complete all as directed.
Form work to sides of roof beam haunching giders, bressumers lintels cantilevers etc. complete all as directed.
RCC (1:1.5:3) using 20 mm graded stone aggregate as in slabs, suported on walls, complete all directed.
Formwork to soffits of suspended slab such as roof slab, floor slab etc. complete all as directed.
TMT bars, 10 dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as directed.
All as per item No. 109 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binder complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as directed.
Demolition of drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar complete all as directed.
PCC 1:4:8 type D-2 using 40 mm stone aggregate as in Foundation filling and mass concrete complete all as directed.
Concrete bed to drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 complete all as directed.
110 mm bore PVC (SWR) waste pipes in any length with rubber ring joints laid in trenches/floor/wall complete all as directed.
Cutting into existing manhole for connecting into new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ section), in cement concrete 1:2:4, type B-1, smooth finished and reforming benching as required for 150 mm bore SGSW pipe, complete all as directed.
Rendering 15 mm thick in cement mortar 1:3 on brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as directed.
Precast RCC 1:2:4 type B-1 using 20 mm stone aggregate, as in manhole cover etc. set in cement mortar 1:4 including necessary form work, complete all as directed.
PCC (1:2:4) type B1, using 20 mm stone aggregate as in coping on manholes including necessary form complete all as directed.
PCC (1:2:4) type B1 by using 20 mm stone aggregate as in surface channels and drain etc. complete all as directed.
Extra for forming fair finished drain or channel 300 mm inner girth in cement concrete using extra cement including forms moulds, mitered / stopped ends etc. complete all as directed.
Supply only integral water proofing compound complete all as directed.
Rendering 15 mm thick on fair faces of brickwork or concrete surfaces in cement mortar 1:6 and finished even and smooth with out using extra cement complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers, not exceeding 250 mm thick, each layer, in soft / loose soil, complete all as directed.
Removing excavated material not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the staring point complete all as directed.
Peg set stainless steel premium 6 hook cloth hanger complete all as directed. Make:- Cat Part No BEA-30 of Prayag or equivalent of Jaquar / Hindware
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc. complete all as directed.
Taking down unserviciable main switch DB, teak wood boards etc. removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc. complete all as directed.
Wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and including non metalic rigid PVC conduit concealed, for modular type steel sheet pressed terminal box (recessed) with modular frame and to cover including accessories, on wall, for housing the switches, switch sockets outlets, fan regulators etc. including provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for one light or fan point controlled by one way switch complete all as directed. Note:- MS sunken boxes, cover plates with frame switches, sockets shall be measured and paid seperately in an appropriate item of BOQ and laying / fixing of sunken box and cover with frame is included in quoted rate.
All as per Item No. 129 above but One 3 pin socket outlet, 5 amps, on independent board.
All as per Item No. 129 above but One 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 129 but wire size 2.5 sqmm for 6 pin 15 Amps switch socket combination outlet on independent board.
Switch Modular type 6 A one way complete all as directed.
One way modular switch 16 A one Module complete all as directed.
Socket outlet 2 in 1, 3 pin, 6 Amps Modular type complete all as directed.
Socket outlet, 2 in 1, 3 pin, 6 / 16 Amps modular type complete all as directed.
Modular fan regulator, step type, electronic, 2 module complete all as directed.
Ceiling rose surface bakelite 65 x 50 mm 3 terminals complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 2 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 3 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 4 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 5 module complete all as directed.
Supply only modular metal flush box with white cover plate with frame of 6 module complete all as directed.
MCB single pole 6 to 40 Amps 240 volts 10 KA rupturing capacity (curve-c) providing in DB complete all as directed.
All as per item No. 144 but SPN
MCB TPN 32 to 63 Amps, 415 Volts (C curve) providing in DB complete all as directed.
Sheet metal enclosure (ISI marked) distribution board SPN, 415 volts, 8 way horizontal type, double door with 200 Amps rated copper bus bar for housing MCBs, fixed flush in wall surface, and tested complete all as directed.
All as per item No. 147 but TPN, 6 way
Sngle pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB complete all as directed.
Sheet metal enclosure TPN DB-VTPN DB's with provision for FP MCB / Isolater / RCCB / RCBO as Incomer and SP / TP MCB's as outgoing with double door 4 way complete all as directed. Make:- Cat part No. Legrand Cat Part No. 507730 or equivalent of Havels / HPL / L&T
Sub main wiring concealed type with 3 runs of 6 sqmm, single core, PVC insulated and unsheathed cable conforming to IS-694, FRLS, 1100 volts with copper conductor multi stranded drawn in non metallic PVC conduit FR grade with all accessories such as Tees, Elbows, junction box, reducers etc as requied all as directed. Note:- Three run of 6 Sqmm cable, one run of of PVC non metalic conduit with all necessary accessories will be measured as one length.
Energy efficient ceiling fan with regulator, 1400 mm sweep, single phase 230 / 240 volts AC and connecting up with flexible three core copper conductor of size 23 / 0.0076 from ceiling rose or connector to ceiling fan, fixed with down rod 300 mm long, rust free powder coated finish and testing on completion, complete including hanging fan to the wooden / steel stresses / angular supports / fan hook etc. and depositing the old fan to AGE E&M Store. complete all as directed. Make:- Kassels 50 product code 250764 of Bajaj or Equivalent of Crompton / Havells
Exhaust fan, metal body, single phase 230 volts AC of 300 mm sweep, 1400 RPM with louvers and connecting up with provision of porciline connector and flexible three core copper conductor of 0.5 sqmm size from terminal point complete all as directed. Make:- Bajaj Cat Part No. 70003 or equivalent of Crompton / Havells
All as per Item No. 153 but 450 mm sweep Make:- Bajaj product code No. 70064 or equivalent of Crompton / Havells
BEE 5 star rated vertical type electric storage type water heater, 2 KW, 230 Volts of 25 Ltr capacity complete all as directed Make:- Venus, Cat No. GHWAMESWH025 or equivalent in Havells / Racold / V Guard / CG
Energy efficient LED batten 20 watt 4 feet IP 20 protection suitable for indoor applications with integrated electronic driver of operating voltage 140 to 270 Volts and extruded Aluminium housing, polycarbonate cover complete with necessary electric connection through suitable size flexible copper conductor cable including taking down old surface/ ceiling mounted FTL fittings complete all as directed. Make-Philips Cat No-BNO2IC LED2OS PSU CDL GR or its equivalent in Havells / CG / Wipro.
LED bateen type, 5 watt, 1 feet long, suitable for indoor application with integrated electronic driver of operating voltage 110 to 265 Volts, lumar output not less than 900 lumen including connecting up and taking down existing unserviceable surface / ceiling mounted 14 / 18 / 20 watt FTL fitting complete all as dirceted. Make:- Bajaj Cat Part No BCLSB 05 NW or equivalent of philips / Wipro /CG / Havels.
Energy efficient LED down lighter 34 watt recess mounted slim type IP 20 protection with integrated electronic driver of operating voltage 220 to 240 Volts, 50 / 60 Hz and polyester power coated housing and high efficiency diffuser cover including connecting up complete and taking down existing unserviceable recess mounted FTL fitting complete all as specified and as directed. Make:- Philips Cat No - RC240B LED34S-6500 OD WH or its equivalent in Wipro / CG / Havells.
Energy efficient LED street light fitting 20 W complete with all fixing arrengements and electric connection, with IP 66 protection suitable for operating voltage 140 to 270 V AC 50 Hz, alongwith active power factor correction electronic gear and LM6 high pressure die cast aluminium housing, polycarbonate cover, fied in repair complete all as directed. Make:- Philips Cat No. BRPO22LED 20 CW MR S1 PSU GR or eqivelent make of CG, Havells, Wipro, C&S etc.
Bracket made out of GI pipe 40 mm dia light grade, 1.5 M long bend to shape for fixing as building security light including necessary clamps, bolt, nut etc. complete all as directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connecting with steel GI earth wire 4mm dia by means of bolt nut check nuts and washers including PCC pit with 1:2:4 type B-1 using 20mm graded stone aggregate and frame cover of angle iron 25x25x6mm, MS sheet 3mm thick and handle of 6mm dia MS bar made to shape, GI medium grade 20mm bore pipe for watering common salt chorcoal funnel wiremesh earth work in any type of soil returning filling in and removal of soft/loose soil to a distance n.exc 5 mtr including earth test point and making connections testing on completion all as per electric plate No 3 of SSR Part-I, complete all as directed.
Laying, jointing, testing and comissioning, cable XLPE insulated, armoured and PVC sheathed LT 1100 volts grade and aluminum conductor confirming to IS 7098 laid in trenches / through pipe / floor / fixed wall etc. for size of cables 25 Sqmm 3.5 core complete all as directed.
River sand to required width at bottom and top for cable cushioning (not less 18 cm thick in layer after punning) complete all as directed
Common burnt clay old size bricks of sub class B laid at right angle on the cable in trenches for cable protection complete all as directed.
laying of GI pipe 50 mm dia, light grade, as in cable protection under road / floor / fixed to wall / panel etc. complete all as directed.
Less Schedule "A" Credit (For Detail description, and rate of particular item, Please refer Schedule "A" Credit Page as attached in Tender Doccuments)
SRI LAKSHMI CONSTRUCTIONS
K. VENKATESH NAIDU
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .