Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | ₹6.5 L Quoted ₹7.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.2 L+₹20,540 (2.92%)Rejected-Finance 138A STANLEY PARK OTTUPATTARAI POST COONOOR 643 105 THE NILGIRIS TAMIL NADU | THE NILGIRIS | TAMIL NADU | 643105 | ₹7.2 L+₹20,540 (2.92%) | L2 | Rejected-Finance quoted amount is higher than 1st lowest |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
5 Oct 2024, 6:00 pmClosed
AGE I AF Coimbatore
AGE I AF COIMBATORE AFAC COMPLEX KAMARAJAR ROAD RED FIELD POST COIMBATORE PIN -641018
REPAIR/ MAINTENANCE OF LIGHTENING PROTECTION SYSTEM AND REPAIR/ MAINTENANCE TO CEILING FANS/EXHAUST FANS/ WALL FAN / AIR CIRCULATOR FAN ETC
2024_MES_670699_1
8978_E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Coimbatore
Class-E category-b (i)(see NIT for detail)
8 documents required · 8 mandatory
₹500
AGE I AF Coimbatore
₹17,000
Yes
5 Dec 2024
3 Sept 2024
8 Oct 2024
4 Sept 2024
5 Oct 2024
17 Sept 2024
4 Sept 2024 - 13 Sept 2024
Amount
Dismentling, Removing the existing disturbed/displaced Copper/Aluminium/GI strips of any sizes from the roof/wall of building, and keeping in a safe custody for taking credit or for re-using serviceable strips in the work complete all as specified and directed.
Fixing only serviceable Copper/Aluminium/GI strips of any size as retrieved from taking down item by straightening, removing the links along the length and refixing the same with and including new porcelain insulators/saddles/screws complete all as specified and directed by Engineer-in-charge.
Supply and fix in repairs Aluminium strip of size 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground level all as specified and directed by Engineer-in-charge. Care should be taken by using all safety devices to ensure safety while working.
Supply and fix in repairs copper strip of size 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and directed by Engineer-in-charge.
Supply and fix in repairs Galvanished iron strip 32x6 mm with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and directed by Enginee-in-Charge
Supply and fix in repairs Air Termination, single pointed Aluminium rod 12mm dia and 300mm long including taking down old unserviceable air termination rod, all as directed by Engineer-in-Charge.
Supply and fix in repairs Test Point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexognal head screw.
M&L for demolition of existing earth chamber including removing the demolised material to the distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 mtr above the starting point and construction of new earth chamber only in same location as per Electrical plate No.3 as shown in SSR Part I 2009 (Section-19) on Page No. 497 inclding excavation on any type of soil, returning filling, removal of surplus material to a distance of 50 metere with specification PCC 1:3:6 type C1 using 20mm graded stone aggregate for bed and chamber, RCC 1:2:4 type B1 using 20mm graded stone aggregate for earth Pit cover 50mm thick with 8mm dia TMT bars at 140mm C/C bothways (instead of CI cover) with lifting handle and fixing of funnel complete with colour code all as specified and directed by Engineer-in-Charge.
M&L for Magnesium sulphate mixing in water, and pouring in existing earth pits in camp area to hold moisture in earth pits complete all as directed. Note: (i) Total quantity brought by contractor shall be diposited in MES store. (ii) The locations of earthing pits and quntity of pottasium nitrate to be poured shall be directed by Engineer-in-charge/JE (E&M)
M&L Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead GI strip 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts, washers of galvanised iron, thimbles and other end of earth lead strip connected to main switch board/ testing point and protected by galvanised iron pipe medium grade 32mm bore and watering pipe 20mm bore medium grade GI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009. (i) The unit rate includes earth lead strip, and protection pipe upto 7.5 metre.
Taking down ceiling fan and exhaust fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing, replacing the, rubber bush ,lock pin and re-assembling/hanging the same back at site complete all as directed by Engr-in-charge. Note:- i)Spares such as bearing/bushes shall be measured and paid seperately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearing of size suitable for 1200/1400 mm sweep ceiling fan. Make: SKF/NBC/TATA
M&L for Removing old burnt out copper winding wire and rewinding the same by using same gauge of copper wire duly applying varnish complete all as directed for 1200/1400 sweep ceiling fan.
Removing the exhaust fan from position of any size type and make, after disconnecting the electrical connections, servicing, cleaning, greasing, and re-assembling/fixing the same in position back at site complete all as directed by Engr-in-charge. Note:- i) Spares such as bearing/bushes shall be measured and paid seperately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearing of sizes suitable for exhaust fan of size 225 mm sweep to 450 mm sweep. Make: SKF, NBC,TATA.
Removing the exhaust fan from position and taking down the old burnt copper winding wire and rewinding the same by using same gauge of copper winding wire duly applying varnish complete all as directed of size 225/305 mm.
All as per item No 16 but of size 380 mm.
All as per item No 16 but of size 400/450 mm.
Removing the wall mounted fan/air circulator/ pedestal fan of any size, type and make after disconnecting the electrical connections, servicing, cleaning, greasing reassembling/ hanging the same in position back at site complete all as directed by Engineer-in-charge. Note:- i) Spares such as bearing/bushes shall be measured and paid seperately under relevant item. ii) Any other minimum spare which is not included in BOQ (schedule) but needs replacement shell be born by tenderer without any extra cost.
M & L for replacing the old unserviceable ball bearings with new ball bearings of sizes suitable for wall mounted fan/ air circulator/ pedestal fan of any size. Make: SKF, NBC,TATA.
Taking down old burnt out copper winding wire of wall mounted fan/air circulator/ pedestal fan of size 300/350 mm and rewinding the same by using same gauge of copper wire duly applying varnish complete all as directed by Engineer-in-Charge.
All as per item No 21 but of size 400/450 mm.
S&F Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
S & F 100 watt, 230V, 50Hz electronic stepped type regulator (switch type size) suitable for ceiling fan including taking down the unserviceable one.
All as per item No 23 above but of socket type size.
M&L for replacing unserviceable capacitors from Ceiling fan/Exhaust fan/wall mounting fan/air circulator of any sizes complete of capacity 2.5 MFD. EPCOS, Havells, Keltron, Crompton.
M&L for replacing unserviceable capacitors from Ceiling fan/Exhaust fan/wall mounting fan/air circulator of any sizes complete of capacity 3.15 MFD. EPCOS, Havells, Keltron, Crompton.
All as per item No. 25 above but of capacity 4 MFD. Make: EPCOS, Havells, Keltron, Crompton.
M & L for replacement of unserviceable burnt flexible cable copper conductor twisted 3 core 23/0.0075 mm size and connecting to ceiling fan all as directed.
M&L for exhaust fan blade heavy duty metallic material factory painted complete suitable for 300/380 mm exhaust fan complete all as specified and directed.
M&L for exhaust fan blade heavy duty metallic material factory painted complete suitable for 400/450 mm exhaust fan complete all as specified and directed.
Supply and fix PVC connection 15 mm size with PTMT nuts of length 600 mm suitable for cold and hot water complete all as specified and as directed.
JOE ENTERPRISES (BID ID -3122143)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .