Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAccepted-AOC 261 3 BESIDE ROYAL HOSPITAL KAMLA NEHRU NAGAR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.8 L+₹36,485.97 (5.70%)Rejected-Finance | L2 | Rejected-Finance DUE TO L2 | |
| 3 | L3₹8.0 L+₹1.6 L (24.4%)Rejected-Finance | L3 | Rejected-Finance DUE TO L3 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
4 Sept 2024, 6:00 pmClosed
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
REPAIR/MAINT OF GI/DI PIPE LINE WITH ALLIED WORKS AT TECH AREA-I, TECH AREA-II, TECH AREA-III, MH, OFFRS MESS AND VARIOUS LOCATION IN AEC TRG COLLEGE AND CENTRE PACHMARHI
2024_MES_662070_1
AGE(I)/PACH/of 2024-25(8655/E8)
Open Tender
Civil Works - Water Works
Item Rate
180 days
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
E CLASS CATEGORY a(ii)
7 documents required · 7 mandatory
₹500
AGE(I) PACHMARHI
₹16,000
1 Oct 2024
25 Jun 2024
6 Sept 2024
25 Jun 2024
4 Sept 2024
9 Jul 2024
Amount
Taking up or down 80mm bore steel tubing and connections, including cleaning for re?fixing or removal to store complete all specified and directed.
All as per Sl No 1 but 50mm bore complete all specified and directed.
All as per Sl No 1 but 40mm bore complete all specified and directed.
All as per Sl No 1 but 25mm bore complete all specified and directed.
All as per Sl No 1 but 20mm bore complete all specified and directed.
Supply, fixing / laying, jointing and testing of 80mm bore GI pipes, medium grade, ISI marked with all fittings fixed on wall/ roof or laid in trenches/ floors complete all as specified and as directed.
All as per Sl No 6 but 50mm bore complete all specified and directed.
All as per Sl No 6 but 40mm bore complete all specified and directed.
All as per Sl No 6 but 25mm bore complete all specified and directed.
All as per Sl No 6 but 20mm bore complete all specified and directed.
S&F in repair 150mm bore sluice valve ISI Marked , Class PN-1.6, both ends flanged with CI body, stainless steel spindle, chucknut and iron wheel etc including provision of new nuts, bolts, washers and gasket including testing and taking down the old one complete all as specified and directed.
All as per Sl No 11 but 100mm bore complete all specified and directed.
All as per Sl No 11 but 80mm bore complete all specified and directed.
S&F in repair 50mm bore Gun metal globe or gate valve with iron wheel head, ISI marked screwed both ends for iron pipes and fixed including taking down the old one complete all as specified and directed.
All as per Sl No 14 but 40mm bore complete all specified and directed.
All as per Sl No 14 but 25mm bore complete all specified and directed.
All as per Sl No 14 but 20mm bore complete all specified and directed.
Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth for foundation etc or for shafts , wells, cesspits, manholes, laying of pipe and exc 10 sqm on plan and n exc 1.5 m in depth getting out in Soft / loose soil complete all as specified.
Returning filling in, including spreading, levelling watering & well ramming in layers not exc 25cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance not exc 50 mtr & depositing where directed at a level not exc 1.5 mtr above the starting point in soils complete all as specified & diected.
M&L for construction of new valve pit/ chamber of single brick masonry using old size bricks in CM (1:4) of size 1200mmx 1200mmx 900mm (internal dimensions) including PCC 1:3:6 type C2 using 40mm graded stone aggregate in foundation & floor (min 150mm thick), internal, external & floor plaster, PCC coping, 5mm thick MS sheet cover with 50x50x6mm MS angle iron frame with locking arrangement including painting two coats of synthetic enamel paint over a coat of red oxide primer and necessary excavation & earth work in any type of soil and removal complete all as specified after demolition of existing old unserviceable valve pit chamber complete all as directed.
Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,100 mm (4”) dia with all fittings and jointing material incl connection of existing water line in main line including tyton joint including taking down the old one complete all as specified and directed by Engineer-in-charge
S & F cast iron/ DI fittings suitable for spigot and socketed pipes up to 150mm bore confirming to IS-1538 for pipes such as bends (any type radius and angle) tappers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branches. "Y" junction, double branch, cross (all sockets or socket and spigot) collers, cap and plug etc complete all as specified and as directed.
S & F GI Pipes galvanized, “Light grade ” 50 mm dia , laid in trench for protection of UG cable/Earthing strip complete including taking out the old one .
Supply, laying, jointing, testing and commissioning LT underground cables, 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured, with multistranded aluminium conductors, laid in trenches/ducts/fixed on poles etc of sizes 35 Sqmm, 3.5 core cable including all electrical connections using suitable size of gland and lungs including taking out the old one complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection cover and pipe shall be measured and paid for separately under respective items of this schedule.
Material and labour for narmada river sand, unwashed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed.
Supply and laying of sub class B bricks old size laid flat adjacent to each other perpendicular to the direction of U/G cable all as specified and directed.
Material and labour for GI earthing strip of size 25X4 mm including nesassary brazing and connecting existing earthing system including taking out the old one complete all as specified and directed by Engineer-In-Charge.
M & L Cast iron foot valve of size 80 mm suitable for fixing in 80 mm GI pipe suction line in UG sump including taking out the old one complete all as specified and directed.
M & L Cast iron foot valve of size 150 mm suitable for fixing in 150 mm GI pipe suction line in UG sump including taking out the old one complete all as specified and directed.
S&F submersible cable, PVC insulated, multistranded copper conductor, 1100 volts grade, 3 core flate of size 6 sqmm. Make : Havelles, RR Kabel, polycab
S&F in repair Automatic star delta starter in sheet metal enclosure, suitable for submersible / centrifugal pump set with relay, contactor, auxilary contactor suitable or capacity above 15 HP and upto 30 HP to run on 440 volts, 50 Hz, AC supply complete all as specified and directed.
M&l for bore well cleaning/washing of tube well by using compressor upto 200 mm bore and upto 1120 mtr depth removing/refixing the submersible pump set of suitable capacity, column pipe, power cable with help of tripod and chain pulley block and remove the dirts sludge, mud, clay, sand, scales from top to bottom level with the help of compressor for smooth functioning of the submersible pump without any trouble to sucking the potable water from the borewell comperatably complete all specified and directed.
Supply only Calcium Hypochlorite 65-70%, purichlar complete all as specified and directed.
MODI CORPORATION (BID ID -3060220)
TANUJ CONST. CO. (BID ID -3076379)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .