Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹11.1 CrAccepted-AOC 143 INDUSTRIAL AREA PHASE II PANCHKULA HARYANA 134112 | PANCHKULA | HARYANA | 134112 | ₹11.1 Cr Quoted ₹11.9 Cr | L-1 | Accepted-AOC ok |
| 2 | L-2₹12.2 CrRejected-Finance 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | ₹12.2 Cr | L-2 | Rejected-Finance Agreement made with L-1 |
| 3 | L-3₹12.6 CrRejected-Finance A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | ₹12.6 Cr | L-3 | Rejected-Finance Agreement made with L-1 |
| 4 | L-4₹12.6 CrRejected-Finance 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹12.6 Cr | L-4 | Rejected-Finance Agreement made with L-1 |
Tender Value
Refer Docs
EMD Value
₹22.5 L
Closing Date
7 Aug 2023, 2:00 pmClosed
Executive Engineer, W.S. Mech. Division, Rewari
Executive Engineer, W.S. Mech. Division, Rewari
Supply, Erection and Commissioning of 02 No. 20Cs. AFVT Pumps (P-1and2), MCC LTD Panel, Motors, Starter and cable of various sizes etc. at Pump House JC-4, JC-5, JC-6, JC-7, PD-1 and Recharge Channel Km 4.964
2023_HRY_297111_6
1961/6-A dated 13.07.2023
Open Tender
Pumps/Motors
240 days
Executive Engineer, W.S. Mech. Division
Please refer Tender documents.
2 documents required · 2 mandatory
₹20,000
Yes
₹22.5 L
Yes
Executive Engineer, W.S. Mech. Division, Rewari
7 Nov 2023
15 Jul 2023
7 Aug 2023
15 Jul 2023
7 Aug 2023
15 Jul 2023
20 Jul 2023
Amount
Supply, erection and commissioning of 20Cs. Axial flow VT Pump of 970 RPM having static lift 24ft with Siphon bend & siphon breaker valve with epoxy coating, incl. welding, etc. complete in all respect as per site requirement and compatible with existing delivery pipe as per approved specification of the deptt. at Pump House JC-4.
Providing and fixing of foundation for 20cs VT Pump by making required size/length at site from ISMB of size (HXB) 300x140mm, approx 3700mm length, 02nos. (make:- TATA/Jindal/SAIL/Vizag). One end for this ISMB section shall be grouted into the wall by making arrangement of PCC block of suitable size as per the weight of the pump, while other end should be welded/bolted to the existing ISMB section with the help of L-bracket and nut, bolts & washers, including material and labour for applying primer and two coat of epoxy paint on the complete foundation and labour charges for taking out old rusted foundation (P-1,P-2) at JC-4.
Supply, erection and commissioning of Solid shaft induction Motor 250HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 6 pole, 760 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for existing 50Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (04nos. at Pump House JC-4, 05nos. at P.H. JC-5, 02 nos. at P.H. JC-6 & 03 nos. at P.H. JC-7).
Supply, erection and commissioning of Solid shaft induction Motor 225HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 6 pole, 980 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for existing 60Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) at Pump House Recharge Chanel Km 4.964.
Supply, erection and commissioning of Solid shaft induction Motor 100HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 6 pole, 970 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for existing 20Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) at Pump House JC-7.
Supply, erection and commissioning of Solid shaft induction Motor 60HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 6 pole, 970 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for existing 20Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) at Pump House PD-1.
Supply, erection and commissioning of Hollow shaft induction Motor 50HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 4 pole, 1440 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for 10Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (01 no. at P.H. JC-6 Jalalpur Disty & 01 no. at P.H. JC-7).
Supply, erection and commissioning of Hollow shaft induction Motor 40HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 4 pole, 1440 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for 10Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) at P.H. JC-5 (Bolni Disty).
Supply, erection and commissioning of Solid shaft induction Motor 40HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 4 pole, 1440 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for 10Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (03 nos. for P.H. JC-4 Raliawas Disty, 01 no. for P.H. JC-4 Jatuwas Disty, 02 nos. for P.H. JC-5 Akhbarpur Disty, 02 nos. for P.H. JC-5 Bolni Disty, 03 nos. for P.H. JC-6 Jalalpur Disty and 02 nos. for P.H. JC-7 Bidawas Disty).
Supply, erection and commissioning of Hollow shaft induction Motor 30HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 4 pole, 1440 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for 7.5Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (01 no. for P.H. JC-4 Raliawas Disty, 01 no. for P.H. JC-5 Akhbarpur Disty, 01 no. for P.H. JC-6 Mangleshwar Disty).
Supply, erection and commissioning of Hollow shaft induction Motor 20HP squirrel cage LT 3 phase 415V for continuous duty, vertical flange mounted, 4 pole, 1440 rpm, TEFC Motor of IE 2 as per IS 12615. The color shade shall be RAL 7031, suitable for 5Cs pump complete in all respect & as per approved specification of deptt. (as per Annexure-B) (01 no. for P.H. JC-5 Akhbarpur Disty, 01 no for P.H. JC-5 Bolni Disty, 01 no. for P.H. JC-6 Jalalpur Disty, 01 no. for P.H. JC-6 Mangleshwar Disty, 02 nos for P.H. JC-7 Bidawas Disty & 01 no. for P.H. PD-1).
Supply, erection and commissioning of Motor Control Center/LT Panel 1600A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB of 1600Amp with 04 Nos outgoings each of having MCCB of 630Amp and 02 nos outgoings each of having MCCB of 400Amp alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars and 4 nos. Fully Automatic ATS starters of 250HP having contactor rating as 700A/400A/265A, complete in all respect like relays, indicators, timers etc. with other allied accessories as per design of Motor Control Centre with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-4.
Supply, erection and commissioning of LT Panel 1600A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB of 1600Amp having 6 nos. outgoings (4nos. each of having MCCB of 630 Amp & 2nos. each of having MCCB of 400Amp) alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-4.
Supply, erection and commissioning of Motor Control Center/LT Panel as per IP-54 with incomer MCCB of 630Amp 4 pole with 5 nos. outgoings each of having MCCB of 150Amp & alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars and with 3 nos. Fully Automatic ATS starters of 50HP having contactor rating as 150/95/65amp & 2 nos. Fully Automatic ATS starters of 40HP having contactor rating as 110/80/50A, complete in all respect like relays, indicators, timers etc. with other allied accessories as per design of Motor Control Centre with a stand of MS Channel/angle having 1 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-4 (Raliawas Disty).
Supply, erection and commissioning of Motor Control Center/LT Panel 1600A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB of 1600Amp with 04 Nos outgoings each of having MCCB of 630Amp and 02 nos outgoings each of having MCCB of 400Amp alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars and 4 nos. Fully Automatic ATS starters of 250HP having contactor rating as 700A/400A/265A and 2 nos. Fully Automatic ATS starters of 100HP having contactor rating as 265/150A/110A complete in all respect like relays, indicators, timers etc. with other allied accessories as per design of Motor Control Centre with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-5.
Supply, erection and commissioning of LT Panel 1600A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB of 1600Amp having 5 nos. outgoings (3nos. each of having MCCB of 630 Amp & 2nos. each of having MCCB of 400Amp) alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-5.
Supply, erection and commissioning of Motor Control Center/LT Panel 400A as per IP-54 with incomer MCCB of 400Amp 4 pole with 4 nos. outgoings each of having MCCB of 150Amp & alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars and with 3 nos. Fully Automatic ATS starters of 50HP having contactor rating as 150/95/65amp & 1 no. Fully Automatic ATS starter of 30HP having contactor rating as 80/50/30A complete in all respect like relays, indicators, timers etc. with other allied accessories as per design of Motor Control Centre with a stand of MS Channel/angle having 1 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-5 (Bolni Disty) .
Supply, erection and commissioning of LT Panel 1000A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB 1000amp 4 pole with 3 nos. outgoings (each of having MCCB of 630Amp) along with D Plug Socket in front side of panel for lighting Load, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-6.
Supply, erection and commissioning of LT Panel 1000A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB 1000amp 4 pole with 4 nos. outgoings (having 2Nos MCCB of 630Amp & 2No MCCB of 400Amp) along with D Plug Socket in front side of panel for lighting Load, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-6.
Supply, erection and commissioning of Motor Control Center/LT Panel 400A as per IP-54 with incomer MCCB of 400amp 4 pole with 5 nos. outgoings each of having MCCB of 100Amp & alongwith D plug socket in front side of panel for lighting loads, indicators, meters, push buttons, bus bars and with 1 no. Fully Automatic ATS starter of 60HP having contactor rating as 150/110/75amp ,3 nos. Fully Automatic ATS starters of 50HP having contactor rating as 150/95/65amp & 1 no. Fully Automatic ATS starter of 30HP having contactor rating as 80/60/32A complete in all respect like relays, indicators, timers etc. with other allied accessories as per design of Motor Control Centre with a stand of MS Channel/angle having 1 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at P.H. JC-6 (Jalalpur Disty).
Supply, erection and commissioning of LT Panel 1000A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB 1000amp 4 pole with 3 nos. outgoings (having MCCB of 630Amp each) along with D Plug Socket in front side of panel for lighting Load, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at Pump House JC-7.
Supply, erection and commissioning of LT Panel 1000A as per IP-54 (should be having enough space for connection of 02 incomer cables from transformer and 01 cable for capacitor bank) with incomer ACB 1000amp 4 pole with 4 nos. outgoings (having 2Nos. MCCB of 630Amp & 2nos. MCCB of 250Amp) along with D Plug Socket in front side of panel for lighting Load, indicators, meters, push buttons, bus bars complete in all respect with other allied accessories with a stand of MS Channel/angle having 2 feet height from floor level & as per approved specification of deptt. (as per Annexure-C) at Pump House JC-7.
Supply, erection and commissioning of Fully Automatic ATS Starter 250HP with a MCCB of 630amp, 415 V, 50 Hz with air breaker power contactors of 700A/400A/265A with meter, relays, indicators complete in all respect, with degree of protection IP 54 including connection and small item like thimble, Nut Bolts Lugs etc. with a stand of MS Angle (50x50x6mm) of 1 feet height from floor level and with allied accessories as per approved make and specification of deptt. (as per Annexure-C). (03 nos. for JC-3, 01 no. for JC-5, 02 nos. at JC-6 & 03 nos. at JC-7).
Supply, erection and commissioning of Fully Automatic ATS Starter 50HP with a MCCB of 100amp, 415 V, 50 Hz with air breaker power contactors of 150A/95A/65A with meter, relays, indicators complete in all respect, with degree of protection IP 54 including connection and small item like thimble, Nut Bolts Lugs etc. with a stand of MS Angle (50x50x6mm) of 1 feet height from floor level and with allied accessories as per approved make and specification of deptt. (as per Annexure-C). (02 nos at P.H. JC-5 Akhbarpur Disty & 01 no. at P.H. JC-7 Bidawas Disty).
Supply and laying of 630 mm2 LT cable single core Aluminum Conductor, XLPE insulated, Armored cable (from Transformer to Motor Control Centre) with thimbles at both ends at P.H. JC-4 and JC-5 (750mtr for JC-4 & 700mtr for JC-5).
Supply and laying of 400 mm2 LT cable 3.5 core Aluminum Conductor, XLPE insulated, Armored cable from LT Panel to Starter Panel with thimbles and with dismantling of old cables from duct at P.H. JC-4, JC-5, JC-6 & JC-7 (700mtr for JC-4, 650mtr for JC-5, 200 mtr for JC-6, 140 mtr for JC-7).
Supply and laying of 1000 mm2 LT cable single core Aluminum Conductor, XLPE insulated, Armored cable (from Transformer to Motor Control Centre) with thimbles at both ends at Pump House JC-7.
Supply and laying of 240 mm2 LT cable 3.5 core Aluminum Conductor, XLPE insulated, Armored cable from main MCC 2000A to MCC 630A with thimbles and with dismantling of old cables from duct at P.H. JC-4 Raliawas Disty and P.H. JC-5 Bolni Disty (130mtr for Raliawas & 120mtr for Bolni Disty).
Supply and laying of 95 mm2 LT cable 3 core Aluminum Conductor, XLPE insulated, Armored cable from MCC 630A to motors with thimbles and with dismantling of old cables from duct at P.H. JC-4 Raliawas Disty and P.H. JC-5 Bolni Disty (40mtr for Raliawas & 40mtr for Bolni Disty).
Fabrication and fixing of cable tray on wall by using Main Angle (size 50x50x5mm) with cross Flat size (50x5mm) and inclined support Angle (size 50x50x6mm) after 10 ft. Length, as per site requirement at P.H. JC-4 & JC-5.
Providing and fixing of Chemical earthing by digging diameter 200mm bore, complete with GI electrode with GI strip of suitable length of 400ft. with proper specification and proper wiring with all allied accessories and coke & salt etc along with name plate complete as per site requirement at P.H. JC-4, JC-5, JC-6, JC-7, PD-1 and Recharge Channel Km 4.964. (02 nos. for MCC/LTDB panels and motors in the each Pump House JC-4, JC-5 & JC-6; 01 nos. for LTDB panels and motors in the each Pump House JC-7, PD-1 & 01 no. for MCC and motors in the Pump House Recharge Channel Km 4.964).
Providing and fixing of Lightening Arrester with lightening striking counter within protection radius of 100 mtr alongwith its earthing as per site requirement at each Pump House JC-4, JC-5, JC-6, JC-7, PD-1 and Recharge Channel Km 4.964.
The above rates are inclusive of all kind of taxes including GST and other expences like F.O.R. destination and inclusive of all incidental charges, enroute & at destination. Nothing extra shall be paid separately. Terms & Conditions as mentioned in Bid document in Price Schedule.
ace marketing pvt ltd
MOHINI ELECTRICALS LTD.
M/s KRP Engineering Pvt. Ltd.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid