Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹16.5 L+₹1.1 L (7.07%)Rejected-Finance H NO B III 95 MOHALLA GHARTHOLI MISSION ROAD PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹17.2 L+₹1.8 L (11.6%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹20.6 L+₹5.2 L (33.6%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹21.1 L+₹5.7 L (36.9%)Rejected-Finance 451 NEAR RADHA KRISHAN MANDIR VPO MAMUN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
20 Jul 2021, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT
REPAIR AND MAINT OF IMPROVEMENT OF UNSERVICEABLE LT PANEL AND REPLACEMENT OF OLD RUSTED PANELS CONTROL SYSTEM, OVERHEAD CONDUCTOR AND CABLE NETWORKING AT BANA ENCLAVE (LTK AREA) UNDER GE (SOUTH) MAMUN
2021_MES_453508_1
GE(S)/M-08/2021-22
Open Tender
Civil Works
Item Rate
270 days
GE SOUTH MAMUN
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹36,000
Yes
4 Sept 2021
22 Jun 2021
22 Jul 2021
22 Jun 2021
20 Jul 2021
7 Jul 2021
Amount
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 4 core including taking out existing cable from trenches or fixed to wall/pole or passing through ducts or pipe of any size, any core , complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Description all as per Srl item No- 6.00 here-in-before but cable of size 35 Sqmm x 3.5 core complete all as specifed and directed
Description all as per Srl item No- 6.00 here-in-before but cable of size 95 Sqmm x 3.5 core complete all as specifed and directed
Description all as per Srl item No- 6.00 here-in-before but cable of size 120 Sqmm x 3.5 core complete all as specifed and directed
Description all as per Srl item No- 6.00 here-in-before but cable of size 185 Sqmm x 3.5 core complete all as specifed and directed
Description all as per Srl item No- 6.00 here-in-before but cable of size 240 Sqmm x 3.5 core complete all as specifed and directed
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, in door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 95 sqmm to 185 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size upto 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 150 sqmm to 185 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 185 sqmm to 400 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
M&L for replacement of 80 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with and including 02 Nos. MS clamp of size 25x4 mm, nuts, bolts and washers complete all as specified and directed.
M&L for replacement of 100 mm bore galvanised steel tubing, light grade, with all fittings, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with and including 02 Nos. MS clamp of size 25x4 mm, nuts, bolts and washers complete all as specified and directed.
S&F "as in repair" MCCB 4 pole, adjustable 415 volts AC of capacity 160 Amps, with rupturing capacity 36 KA, including providing thimble for out going cables complete all as specified and directed.
Description all as per Srl item No- 20.00 here-in-before but of capacity 200 Amps complete all as specifed and directed
Description all as per Srl item No- 20.00 here-in-before but of capacity 250 Amps complete all as specifed and directed
Description all as per Srl item No- 20.00 here-in-before but of capacity 350 Amps complete all as specifed and directed
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , location of LT panel nearby Bldg No 245 Bana Enclave suitable for and including taking down existing LT panel complete and including the following :-
(i) MCCB 4 pole 415 volts with thermal magnetic release rupturing cap 36 KA, 300 amps - 1 No. as incomer.
(ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 36 KA, 160 amps - 8 No. as outgoing.
(iii) LED Indicator lamp set RYB -01 Set of 3 pcs.
(v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio.
(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, commissioning and testing of totally enclosed outdoor type LT Panel in replacement weldless cubical Kiosk in modular bolted construction type dust and vermin proof floor mounted type (IP-65 degree of protection ) made out of 3 mm thick CRCA sheet of recommended size.All sheet metal parts separately chemically treated with 7 tank treatment process. The panel having both side opening door with locking arrangement.all doors fixed with aluminium hinges with suitable size nut bolts and shall have flexible fixing of each switchgear and controlgrae compartment with cable alley tray of size not less than 30 cm. duly painted with two coats of synthetic enamel paint powder coated, bus bar 1000 amps rating made of aluminium strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50 HZ AC supply ,hibling , cable entry boxes , cable gland and LT panel shall be mounted on iron angle frame made out of 50 X 50X 6 mm frame with 4 no. legs size nit less than 45 cms fixed with nut bolts of suitable size (bottom portion of the panel) , grouted by using foundation 1:2:4 type C1 with 20 mm graded stone aggregates totally tested as per IEC 61439-I , location of LT panel nearby Bldg No 251 Bana Enclave suitable for and including taking down existing LT panel complete and including the following :-
(i) MCCB 4 pole 415 volts with thermal magnetic release rupturing cap 36 KA, 350 amps - 1 No. as incomer.
(ii) MCCB 4 pole 415 volts with thermal based release rupturing cap 36 KA, 160 amps - 6 No. as outgoing.
(iii) LED Indicator lamp set RYB -01 Set of 3 pcs.
(v) Multifunction digital panel meter suitable to display amps, volts, frequency etc - 01 No including CTs of appropriate ratio.
(vii) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, installation, connecting electrically and testing of street light panel box complete with and including Astronomical timer ,contactor rating 65 Amp, MCB 63 A TPN complete. Panel box shall be made out of CRCA sheet 1.6 mm thick, powder coated, having provision for Astronomical Timer, Contactor, Toggle switch, SP MCBs and MCCBs etc. having self closing door lock complete with fixing clamps or mounting arrangement all as required at site, specified or directed including taking out existing U/S street light switch any type and size complete all as specified and directed.
Trimming up of Bushes/ Tree branches upto 5 mtr all along security light poles both side of the road from Bana to Khetrapal, removing cut branches from site as directed, Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches upto 5 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines complete all as specified and directed.
Material and labour for detection of any type of fault in HT underground Line of any size and core. (laid in soil at plane area or forest area) with the help of HT Meggar. Seggregation of faulty span by meggering and making span serviceable by repair of cable or replacement of cable complete all as specified and directed. Note : 1. Detection of one fault in faulty span will be measured as Each Job. 2. Excavation and earth work and taking out/retrieving of cable shall be measured and paid for seperately. 3. Material for repair and replacement shall be measured and paid for separately.
M&L as in repair/replacement of mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint including dismantling cross-arms of M.S. channel or angle sections etc, from pole complete all as specified and directed.
Restretching aluminium conductor or GI wire on existing over head lines (running on 11 Mtrs pole) without removing including unbinding from insulator and rebinding to insulator using aluninium binding wire, connections of incoming and out going cables, binding with spacers where required, complete all as specified and directed. (Note ;- For measurement length of set of 3 conductors incl GI wire / Cradle or guarding wire shall be taken as one sapn).
M&L for ACSR conductor (Weasel conductor 6 x 2.59 + 1 x 2.59 Al + Steel), of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, including dismantling and taking down carefully existing old ACSR conductor/GI wire of any size from HT/LT overhead line complete all as specified and directed. Note:- 3% for sag shall be added.
S&F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade including taking down old one complete all as specified and directed.
S&F Shackle insulators porcelain, vitreous, white,brown or green insulator including one set of galvanised mild steel section of straps 31 x3 mm, dia of bolt 12mm alongwith iron washers and one galvanised iron nut, 75mm height, 95mm dia for 1100 volts grade including taking down old one complete all as specified and directed.
M&L for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 including taking down existing stay assembly complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed.
M&L for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 90 x140 mm, clearance of hole 25.5 mm, including taking down old one complete all as specified and directed.
M & L for Scraping of old paint from the steel tubular pole 9 mtr height with out removing accessories and preparation of surfaces for repainting. Repainting the pole with one coat of 30 cm alternative green and white strips of each upto 1.5 mtr height using synthetic enamel paint. Repainting the remaining pole and iron parts i.e. U clamps, channels etc above 1.5 mtr height by applying Two coat of aluminium paint, including writing letters or figures (Block, Roman, Italic or Indian) S/L Pole No. and Location code not exceeding 30 cm high, stop, commas, short lines, dashes, hypens, brackets etc. complete all as specified and directed.
M&L for painting of PCC pole 11 Mtr height without removing accessories with two coats of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying two coats of alumn paint all as required at site, complete all as specified and directed by Engineer-in-Charge.
M&L for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
M/S HIMANSHU BUILDERS
M/S SHAKTI ELECTRIC WORKS
KULBHUSHAN AGGARWAL
RD Engineers
dinesh enterprises
Vijay Kumar Contractor and Engineers
Bidder Name
KULBHUSHAN AGGARWAL
Vijay Kumar Contractor and Engineers
RD Engineers
M/S Vijay Punj Constructions
M/S SHAKTI ELECTRIC WORKS
dinesh enterprises
M/S HIMANSHU BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .