Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.7 LAccepted-AOC OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹35.1 L+₹4.1 L (13.4%)Rejected-Finance 93 BAPUJI NAGAR ITC ROAD SAHARANPUR 247001 UP | SAHARANPUR | UTTAR PRADESH | 247001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹43.9 L+₹13.0 L (41.9%)Rejected-Finance HOUSE NO 165 A VILLAGE POST MORTA DISTT GHAZIABAD U P PIN 201003 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201003 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹44.5 L+₹13.6 L (43.8%)Rejected-Finance PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L4 | Rejected-Finance Being 4th lowest |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
18 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
PERIODICAL SERVICES TO MD ACCN AND OTM ACCN IN DOMETIC AND TECH AREA AT AF STN SARSAWA
2021_MES_471136_2
8121/SAR-45/E8 PERIODICAL SERVICES TO MD ACCN
Open Tender
Civil Works
Item Rate
183 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹80,000
Yes
27 Oct 2021
30 Sept 2021
20 Oct 2021
30 Sept 2021
18 Oct 2021
4 Oct 2021
30 Sept 2021 - 4 Oct 2021
60 days
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed by Engr-in-Charge.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15mm thick in CM 1:4 on stone/brick mersonry as concrete wall surfaces or other than fair faces of brick work & surfaces finished even and smooth without using extra cement with water proof compound ( water proof compound paid seperatly) all as specified & directed by Engr-in-Charge.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying one coats of Oil bound distemper over a coat of 1mm thick wall care putty of approved tint complete all as specified & directed by Engr-in-Charge.
M&L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of newly plastered surface of walls & applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engineer-in-Charge
Material and labour for preparation of newly plastered/unplastered surfaces of ceilings & applying three coats of white wash complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered/unplastered surfaces of ceilings & applying two coats of oil bound distemper (OBD) complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old decorated surfaces of walls and applying one coat of oil emulsion distemper (OBD) of approved shade/tint all as specified & as directed.
M&L for preparation of old decorated surfaces of walls and applying two coat of oil emulsion distemper (OBD) of approved shade/tint all as specified & as directed.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint of approved shade/tint complete all as specified & as directed.
M&L for preparation of old decorated surfaces of walls, plastered including cornices, pilasters etc and applying one coats of white wash complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old decorated surfaces of walls, plastered including cornices, pilasters etc and applying two coats of white wash complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old decorated plastered/unplastered surfaces of ceilings & applying one coats of white wash complete all as specified and directed by Engineer-in-Charge
M & L for complete removal of existing treatment on walls/ceilings and preparation of surfaces of walls/ceilings and applying 1mm thick birla/shalimar care putty complete all as specified and directed by Engr-in -Charge.
M & L for plaster/unplastered new/old surfaces on walls/ceilings and preparation of surfaces of walls/ceilings and applying 1mm thick birla/shalimar care putty complete all as directed by Engineer-in-Charge
M&L for preparation of old decorated plastered/unplastered surfaces of ceilings & applying one coats of oil bound distemper (OBD) complete all as specified and directed by Engineer-in-Charge
M&L preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge
M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified and directed by Engineer-in-Charge
M&L for preparation of old /newly BRICK, STONE, CONCRETE, ASBESTOS CEMENT SHEET OR PLASTER Surfaces of any description over 10cm girth or width, not otherwise described and applying one coat of apex weatherproof exterior emulsion paint complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer-in-Charge
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces complete all as specified.
M&L for 3mm thick froasted glass and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces complete all as specified and directed by Engineer-in-Charge
Demolition/Removal of existing RCC water tank including cover (Capacity not exc. 1000 Ltr) placed on roof of the Bldgs/Quarters including removal of their staging/platform complete all as directed by Engineer-in-Charge Note : (i) Tank/staging shall be taken down after demolition in small pieces. (ii) Demolition shall be carried out carefully without damaging roof treatment. (iii) Roof treatment came out/damaged during demolition shall be made good with same specification without any extra cost. (iv) Small trees/Plantation near the tank shall be uprooted and roof treatment shall be made good.
M & L for brick work placed on roof of the Bldgs/Quarters for water tank plarform with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge
M&L for rendering 15mm thick in CM 1:4 on stone wall surfaces fair faces of brick work & surfaces finished even and smooth without using extra cement mixed with water proof compound ( water proof compound paid seperatly) complete all as specified and directed.
Supply only integral liquid water proofing compound (ISI marked). Make : Pidilite (Dr. Fixit Pidiproof LW) or equivalent of Fosroc / Sika / STP complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed and directed by Engineer-in-Charge
Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I complete all as specified and as directed and directed by Engineer-in-Charge
Supply and fixing Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 15/20mm dia (minimum weight 142/210 gms) complete all as specified and as directed and directed by Engineer-in-Charge
S&F in repair for 18/19mm thick High Density High Moisture Resistant board (HDHMR) Prelaminated both sides as in Controller's Desk ,palmed boxes,showcase,shutters of Cup Boards etc including 6mm designing teak wood beading on edges complete all as specified and as directed by Engr-in-Charge.
S&F 75mm extruded brass handles, fabricated type polished complete all as specified & directed by Engr-in-Charge.
S & F Width of flaps (when open) 30mm Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified & directed by Engr-in-Charge.
S&F FAST DM01SS Stainless Steel Furniture Door Catcher Magnet Size No. 2 for for Wadrobe, Cupboard and Almirah Door. (SS MAT) with Mounting Screw complete all as specified complete all as specified and as directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed by Engr-in-Charge.
M&L for 25 thick cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in levelling coarse for tiles.complete all as specified and as directed by Engineer-in-Charge.
M&L for 100 mm thick PCC 1:4:8 type D -2 using 40 mm graded stone aggregate as in sub base complete all as specified& directed by Engr-in-Charge.
M&L for Providing and laying prepolished cement concrete Chequered tiles 30cmx30cmx25mm thick, with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape heavy duty , set,jointed and pointed in neat cement slurry in floors over screed bed 15mm thick 1:6 cement mortar complete all as specified& directed by Engr-in-Charge.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed by Engr-in-Charge.
Material and labour coloured non skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed by Engr-in-Charge.
Dismentling floor , hearth or wall tiling incl cement mortar bedding (but ot backing) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
M&L for vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4 complete all as specified and as directed by Engr-in-Charge.
M&L Glazed ceramic coloured tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of the tiles and over 10 mm thick rendring in cm 1:4 complete all as specified& directed by Engr-in-Charge.Make- Somany/Johnson/Orient
M&L for 18/19mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed CM 1:6 complete all as specified& directed by Engr-in-Charge.
S&F in repairs powder coated stainless steel drapery rod of 25 mm inner dia (in lengths as directed) of approved colour with & including decorative bowel at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C all as specified & as directed by Engr-in-Charge.
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame exc 1.5 sq. m but n exc 4 sq m each.complete all as specified and as directed by Engineer-in-Charge.
Taking down Chowkatts or frames with shutters ( without taking off shutters from the frame) n exc 1.5 sq.each.complete all as specified and as directed by Engineer-in-Charge.
S&F anodized aluminium frame with power coating (minimum thickness 50 micron) and other sections for doors, windows, ventilators, partitions, with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed by Engr-in-Charge.
S&F anodized aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m,with power coating (minimum thickness 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos), suitable handle (1 No.) complete all as specified & as directed.
Supply only 5mm thick Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge
Supply only 5mm thick froasted glass in squares n exc 0.5 sq. m each pane all as specified and directed by Engr-in-Charge
S&F anodized aluminium grill with power coating (minimum thickness 50 micron) of approved pattern and fixed to the existing window/ventilator frame with CP brass/stainless steel scrwed @ 200mm center to center, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement & directed by Engr-in-Charge.
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified& directed by Engr-in-Charge.
S&F Factory made steel windows, box type,any size[ (XW2)M/F] double shutter, one openable shutter with galzing bars and other openable shutter without glazing bars, fabricated with members of standard sizes as shown on drawings including frames complete all as shown specified on drg no- (Drg No. CE(AF) WAC Palam Delhi Drg No -CEAF/STD-184-2012 . (Note :- The quoted rates shall be deemed of lugs and FI required for fixing wire cloth, Grills, wire cloth, sheet glass,iron mongry and guard bars as shown on drg and applying Two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge
S&F Factory made steel ventilators, box type,any size[ (XW2)M/F] double shutter, one openable shutter with galzing bars and other openable shutter without glazing bars, fabricated with members of standard sizes as shown on drawings including frames complete all as shown specified on drg no- (Drg No. CE(AF) WAC Palam Delhi Drg No -CEAF/STD-184-2012 . (Note :- The quoted rates shall be deemed of lugs and FI required for fixing wire cloth, Grills, wire cloth, sheet glass figured type,iron mongry and guard bars as shown on drg and applying Two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., or cutting out defective masonry for underpinning including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to store and rubbish off the premises complete all as specified and as directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any thickness complete all as specified and directed complete all as specified and as directed by Engineer-in-Charge
M&L for false ceiling made out of E-board classic of size 595 x 595 x 4 mm thick, (as approved by GE) fixed with existing frame work fixing the board to frame complete all as per manufacurers instructions complete all as specified and as directed by Engineer-in-Charge.
Dismantling of false ceiling grid any type including cover fillets complete all as specified and as directed by Engineer-in-Charge.
M&L for GI frame consisting of main Tee of size 38.50 x 24.00 mm and cross Tee of size 28.50 x 24.00 mm thick made out of PGI sheet 0.30 mm thick doubled at web and single at flange, flange covered with powder coated sheet 0.25 mm thick and angle 24.00 x 24.00 x0.4 mm thick powder coated suspended with GI wire 3 mm dia and up to 2 Mtrs long complete including plugging fixing of angle to brick walls with steel rawl plugs @ 450 mm c/c complete all as specified and as directed by Engineer-in-Charge.
G.H. INFRASTRUCTURE PRIVATE LIMITED
NAVEEN KUMAR TYAGI
RADHA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .