Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-Finance | ₹19.4 L | L1 | Accepted-Finance OK |
| 2 | L2₹34.8 L+₹15.4 L (79.3%)Accepted-Finance | ₹34.8 L+₹15.4 L (79.3%) | L2 | Accepted-Finance OK |
| 3 | Rejected-Technical | - | - | Rejected-Technical DUE TO NOT FULL FILL TECHNICAL ELIGIBILITY CRITERA |
| 4 | Rejected-Technical | - | - | Rejected-Technical DUE TO NOT FULL FILL TECHNICAL ELIGIBLITY CRITERIA |
| Sl No | Description | Qty | Unit | APURV ENTERPRISES L2 | Kluger DART LLP L1 |
|---|---|---|---|---|---|
| 1.01 | Ultrasonic sensor: Digital display through ultrasonic sensor. This ultrasonic sensor should be suitable for clear water tank, with the capability to observe the water depth in meter/feet as per the requirement upto 15 meter depth. This system should operate on 220v/440v AC. Ultrasonic Sensor's input power supply should be 24 VAC±10%, Type: 2/4 Wire, Dead Band 450mm for up to 18 meter, Beam Angle (a): 12°/14°/5°, Applied Material: PP/PVDF/ABS/PC housing, Ingress Protection against short circuit, Process Temperature: -10° C TO 60° C.Ambient Temperature: -10° C TO 55° C. Operating Pressure: Atmospheric, Accuracy: ±(0.2% Of measured distance +0.05% of range), Resolution (depend on distance): Imm to 10mm, Output: Analog: 4-20mA, Top mounted.LCD Display, controller having 2 relay 4 outputs, contact rating 230V AC, 7 amp., configurable as control outputs on separate set Points, with pre-defined logic with 7 segments LED, Supported by 4 key tack-tile keyboards, Input will be 4-20 mA linear with resolution. Supply 230V AC 50Hz & output 24 VDC 120 mA. Supply of Enclosure and frame of SS to hang the sensor, all the accessories fitted should be in powder coated paint CRC sheet cabinet, Supply of 3 core shielded copper wire 1.5 sq. mm (as per site requirement).Charges for installation, testing and commissioning which will also include the dismantling of the old material (if any) & all PVC Pipe and Fitting, laying cables with proper conduiting along with thimbling etc, all the civil work required and other work required as per the site engineer.Calibration of the sensor at the site as per the requirement. installation, Testing and commissioning of the entire system., For 0.2 MG UGR- depth 3 mtrs., 5 MG UGR- depth 5 Mtrs., 1 MG UGR-depth 5 Mtrs and 2.4 MG UGR- depth - 5 Mtrs. Fixing, testing and commissioning, as per direction of Engineer-in-Charge. Make: Siemens / Vega / Skope / Any approved make of DJB. | 5 | Nos | 29,50,000 ₹34,81,000 | 16,45,000 ₹19,41,100 Lowest |
Tender Value
Refer Docs
EMD Value
₹68,500
Closing Date
17 Aug 2026, 2:15 pmClosed
EE
CHANDRAWAL WATER WORKS
SITC of Water level Indicator for 5 Nos. UGRs emanating from Okhla Water Works.Re-invite. Make- Any approved make of DJB.
2026_DJB_296859_5
NIT NO. 06 (2026-27)/WW-III
Open Tender
Miscellaneous Works
Works
120 days
CHANDRAWAL WATER WORKS
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DJBEMD A/c No-50448339804 Direct Link Through Su
₹68,500
28 Aug 2026
11 Aug 2026
17 Aug 2026
11 Aug 2026
17 Aug 2026
11 Aug 2026
11 Aug 2026 - 17 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Ultrasonic sensor: Digital display through ultrasonic sensor. This ultrasonic sensor should be suitable for clear water tank, with the capability to observe the water depth in meter/feet as per the requirement upto 15 meter depth. This system should operate on 220v/440v AC. Ultrasonic Sensor's input power supply should be 24 VAC±10%, Type: 2/4 Wire, Dead Band 450mm for up to 18 meter, Beam Angle (a): 12°/14°/5°, Applied Material: PP/PVDF/ABS/PC housing, Ingress Protection against short circuit, Process Temperature: -10° C TO 60° C.Ambient Temperature: -10° C TO 55° C. Operating Pressure: Atmospheric, Accuracy: ±(0.2% Of measured distance +0.05% of range), Resolution (depend on distance): Imm to 10mm, Output: Analog: 4-20mA, Top mounted.LCD Display, controller having 2 relay 4 outputs, contact rating 230V AC, 7 amp., configurable as control outputs on separate set Points, with pre-defined logic with 7 segments LED, Supported by 4 key tack-tile keyboards, Input will be 4-20 mA linear with resolution. Supply 230V AC 50Hz & output 24 VDC 120 mA. Supply of Enclosure and frame of SS to hang the sensor, all the accessories fitted should be in powder coated paint CRC sheet cabinet, Supply of 3 core shielded copper wire 1.5 sq. mm (as per site requirement).Charges for installation, testing and commissioning which will also include the dismantling of the old material (if any) & all PVC Pipe and Fitting, laying cables with proper conduiting along with thimbling etc, all the civil work required and other work required as per the site engineer.Calibration of the sensor at the site as per the requirement. installation, Testing and commissioning of the entire system., For 0.2 MG UGR- depth 3 mtrs., 5 MG UGR- depth 5 Mtrs., 1 MG UGR-depth 5 Mtrs and 2.4 MG UGR- depth - 5 Mtrs. Fixing, testing and commissioning, as per direction of Engineer-in-Charge. Make: Siemens / Vega / Skope / Any approved make of DJB. | 5 | Nos | 80 | ₹400 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
NIT06.pdf
Tender Documents • 0.79 MB
BOQ_395304.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .